w TH DOC. NO.: GEN-TEL-SPC-0013 REV.: B PAGE 1 OF 20 BASIC DESIGN SPECIFICATION FOR TELECOMMUNICATION CABLE A ISSUED FOR APPROVAL 2016.8.15 wr we Lec we REV. DESCRIPTION DATE PREP'D cHK’D REVD APP’D BASIC DESIGN DOC. NO.: GEN-TEL-SPC-0013 REV. B PAGE 2 OF 20 Revision History Revision A was completed on Jul 15", 2016. Revision B is updated based on PCH comments on Apr 18", 2019. Detail modification shall be as per revision marker in the documents. Major changes as following: ‘Chapter Revised to ‘Add note:” This specification is updated under the Project of GES cover for Halfaya Oilfield Projects(Y 2019-2021), Project ID is 3725, and Contract No: HFY-CON/F&C0925-0949" ‘Add demand “fre resistant where route pass through a high heat area” ‘Add Item “Low Smoke Zero Halogen” 42 Modified “Cat6 4 pairs" UTP to “CATE 4-pairs UTP” Modified to °2. outside signal cable (Armoured Anti-flaming, signal cable 2X 2.5 (ZR-KYJVP32 300/500V 2'2.5) "to "2, outside signal cable (Armoured Antisflaming, fire resistant signal cable 2X2.5 (ZR- KYJVP32 300/500V 2"2.5) * 44 44 BASIC DESIGN DOC. NO.: GEN-TEL-SPC-0013 REV. B PAGE 3 OF 20 CONTENT 1.0 GENERAL .. 1.1 Purpose. 1.2. Definitions and Abbreviations 1.3. Vendor Qualification .. 1.4 VENDOR’s Responsibility 41.5 COMPANY Access .. 1.6 — Language and Units... 2.0 SITE CONDITIONS. 3.0 APPLICABLE REGULATIONS, CODES, STANDARDS AND SPECIFICATIONS.....: 3.1 General 3.2 International Standards and Codes... eo © e e@Noaanaaaa 3.3 Contflicting Requirements, Deviation and Substitution 3.4 Order of Precedence for Documents. 4.0 TECHNICAL REQUIREMENT 4.1 General Requirements... 42 — Specification for LAN and IP Telephone System Cable 4.3 Specification for CCTV System Power Cabl 4.4 — Specification for PAIGA System Cabl 45 Specification for Fire Alarm System (FAS) Cable. 48 — Specification for Access Control System (ACS) Cable 4.7 Specification for other Cabl 5.0 CABLE MARKING. 6.0 | CABLE CONSTRUCTION.. BASIC DESIGN DOC. NO.: GEN-TEL-SPC-0013 REV. B PAGE 4 OF 20 7.0 INSPECTION AND TESTING... 8.0 | GUARANTEE AND WARRANTY. 9.0 QUALITY ASSURANCE... 10.0 DOCUMENT REQUIREMENT.. 11.0 DELIVERY, STORAGE AND HANDLING.... = _ os «< = I BASIC DESIGN DOC. NO.: GEN-TEL-SPC-0013 REV. B PAGE 5 OF 20 1.0 GENERAL 11 Purpose This specification applies to Hafaya oilfield telecommunication Cable, including LAN, CCTV , PAJGA Fire Alarm System and access control system cable 1.2 Definitions and Abbreviations 1.2.1 Definitions WORD MEANING COMPANY. PetroChina International Iraq FZE Iraq Branch ‘The organization selected and entrusted by COMPANY to perform the CONTRACTOR Engineering, Procurement, Construction, Start-up, pre-Commissioning and Commissioning of the Project. ‘The party who is in charge of awarding agreement on behalf of PURCHASER COMPANY / CONTRACTOR for the supply of goods and services in connection with the work. VENDOR! SUPPLIER’ | The Party to the contract andlor purchase order which has undertaken the obligation to supply the goods andlor services which are ordered SUBCONTRACTOR | or Sined herein, Shall Indicates a mandatory requirement ‘Should Indicates a strong recommendation to comply with the requirements of, this document 1.2.2 Abbreviations ‘ACRONYM MEANING uv. Ultraviolet PVC Polyvinyl Chloride LAN Local Area Network 1 Intemet Protocol AWS ‘American Welding Society IEC International Electrotechnical Commission UTP Unshielded Twisted Paired Foc’ Fiber Optical Cable HDPE High Density Polyethylene cctv Closed Circuit Television XLPE (Cross Linked Polyethylene ZRPVC Flame Retardant- Polyvinyl Chloride PAIGA Public Address and General Alarm System Dc Direct Current BASIC DESIGN DOC. NO.: GEN-TEL-SPC-0013 REV. B PAGE 6 OF 20 13 & 14 15 Vendor Qualification » Vendor shall have at least 5 years’ experience of similar engineering applications where the telecom cable has been in use. > Vendor shall provide user list included user name, site location, running time, and brief project summary in the bid. Vendor shall provide the licence and certification to prove that the application of the provided telecom cable shall be appropriate and legal for the project. VENDOR's Responsibility VENDOR shall take full responsibilty for mechanical design, provision of materials, fabrication, inspection, testing, and quality of workmanship unless agreed otherwise with COMPANY. VENDOR shall also handle and expedite the drawings, and supervise and coordinate all tests as specified It ic VENDOR’ reeponeibility to bring promptly to the PURCHASER's attention any errors or discrepancies which are found to exist between this specification and the other specifications andfor data sheet. in this connection VENDOR shall take into consideration the prevailing industry practices for design and fabrication of similar service and construction VENDOR should supply all designing, testing and operating, maintenance related documents to COMPANY Review by COMPANY of VENDOR drawings or other documents, or release of equipment for shipment by PURCHASER’s authorized representative shall not relieve VENDOR of any of these responsibilites for compliance with this specification nor alter the conditions of the guarantee. COMPANY Access COMPANY andior authorised representatives shall have free access and the right to inspect and/or witness any of VENDOR'S activities, operations, reports and certificates in connection with the equipment purchased to this specification. COMPANY and/or his authorised representative may, at no extra cost to COMPANY, reject any work failing to ‘meet the purchase order requirements Language and Units The governing language shall be English language. All notices, correspondence, information, literature, data, manuals and other documents required under the Contract shall be in the English language. Technical units, quantities, etc. shall be expressed, used and abbreviated according to the SI system. Preferred units of measure are as for: BASIC DESIGN DOG. NO.: GEN-TEL-SPC-0013 REV. B PAGE 7 OF 20 Flow Rate mhr, MMSCFD (gas), BPD (condensate), BWPD (Water) Power, Duty 2 kW Area om Length meter (m), km, mm Pressure : Bar (g), Bar (a), KPa (g) Temperature 2c Volume 2m Weight i Kg 20 SITE CONNITIONS The following are the climatic conditions for all equipment and facilities, BASIC DESIGN DOC. NO.: GEN-TEL-SPC-0013 REV. B PAGE 8 OF 20 Altitude mas. | 056 Atmospheric Pressure kPa | 102 Max. Temp. c 35 Wet Bulb Temp c 22.2 (GPSA 11-3b) Dry Bulb Temp. c 42.2 (GPSA 11-26) Max. Metal temp. by sun shine | 80 Min. Temp. c 2 Max. Speed Wind ms (40 Prevailing Direction Wind | (winter) _ | NW-SE Prevailing Direction Wind | (summer) | NW-SE Max. Relative Humidity 80% Min, Relative Humidity 25% Rainfall mma | 174 4-hour Rainfall mm | 4t Under Ground Temp. c Sa Seismic Zone 28 Evaporation Rate mma | 3054.4 3.0 APPLICABLE REGULATIONS, CODES, STANDARDS AND SPECIFICATIONS 34 A General Telecommunication Cables shall meet or exceed requirements specified in the latest editions or the equivalent ones of the following standards and specifications. if any requirements are specified in more then one standard or specification at the same time, the most stringent shall be followed. In addition, Telecommunication Cables shall also comply with laws and regulations approved by local government. Before design and manufacture of Telecommunication Cables, if any contradiction between this Technical Specification and relevant technical specifications or correspondences, the PURCHASER shall be consulted and written confirmation from the PURCHASER shall be obtained before any further work starts. BASIC DESIGN DOC. NO.: GEN-TEL-SPC-0013 REV. B PAGE 9 OF 20 3.2 33 International Standards and Codes The following codes and standards, to the extent specified herein, form a part of this specification. When an edition date is not indicated for a code or standard, the latest edition in force at the time of VENDOR’s proposal submitted shall apply. IEC 60228 Conductors of insulated cables 1EC 60331 Fire resisting characteristics of electric cables IEC 60332-2 Tests on electric cables under fire conditions |EC 60502-1 Power cables with extruded insulation and their accessories IEC 60811 — Common test Methods for Insulating & Sheathing Materials of Electric Cables. IEC 61034 Test for measurement of smoke density @ BS 5308 Instrumentation cables © BS 5467 Electric cables. Thermosetting insulated, armoured cables for voltages of 600/100 V and 1900/3300 V @ EN 50307 Lead and lead alloy sheaths and sleeves of electric cables TIAEIA-568-A5 Transmission Performance Specifications for 4-Pair 100 Ohm Category 5e Cabling ISO/IEC 11801 Generic Cabling System for Customer Premises. EIATIA-568B Commercial Building Telecommunications Cabling Standard EIA 568B, TSB 67 Field Testing of Generic Cabling. IEC 61156-5 Multicore and symmetrical pair/quad cables for digital communications - Part 5 Conflicting Requirements, Deviation and Substitution In the event of a conflict between this specification and other specifications or correspondence, VENDOR shall consult with the COMPANY’s designated representative and a ruling, in writing, shall be obtained before any work is started. Where Provincial or National Codes conflict with this specification, the more rigid requirement shall govern Any deviation from this specification must be approved, in writing, by the COMPANY's designated representative. Alternatives may be offered for materials and fabrication, if technically or economically justified and provided that they meet the requirements of the applicable codes, standards and specifications. BASIC DESIGN DOC. NO.: GEN-TEL-SPC-0013 REV. B PAGE 10 OF 20 34 40 44 Order of Precedence for Documents All conflicts between the requirements of this specification, related contract documents, national / international documents, codes, engineering practices and the requisition shall be referred to COMPANY/PURCHASER for clarification. Should any conflict occur in the application of these specifications, the order of precedence shall be as follows: 1) PURCHASER order (including attachments) and variations thereon; 2) Data sheets and drawings; 3) This Technical Specification; 4) Project Specification in conjunction with native standard; 5) International codes and standards. TECHNICAL REQUIREMENT General Requirements Cables included in this specification shall be suitable for installation above or under ground in industrial plant areas with hazardous atmospheres. All external signal cables and control cables shall be manufactured with twist, extruded insulation, crosslinking, fire resisting technology. All cables shall be water, oil, UV resistant, abrasion resistant, gas vapour tight and ‘compatible with the environment and flame retardant specified as per IEC 60332. All cables shall comply with IEC recommendations. Cables used for external installation shall be armoured, Armour type shall be round steel wire. Lead sheathing shall be specified for underground cables, where considerable soil contamination by liquids aggressive to the cable insulant is anticipated, otherwise, protection approach by PVC or galvanized steel conduit shall be provided. The outer sheath of telecommunicaticn cables shall be immune to the effects of ultra Violet radiation. The inner sheath shall be extended to fill all spaces between cores to prevent the passage of gas or other noxious substance along the cable. Within building, cables installed between equipment and/or rooms shall be un-armoured. Flame retardant cables according to IEC 60332 shall be used for outside and inside telecommunication cables as a minimum requirement. Fire resistant cables according to IEC 60331 shall be fire resistant where route pass through a high heat area used for Fire Alarm system, PA/GA system. Cables shall be low fume emission for: © Sulphur © Nitrogen e Carbon Monoxide BASIC DESIGN DOC. NO.: GEN-TEL-SPC-0013 REV. B PAGE 11 OF 20 AB © bee Saas Zoratacwen 42 Allowances on delivered lengths shall be 0 to +5%. The wire or cable should have a temperature rating of 75°C as minimum, high temperature insulation should be used in areas of expected high temperature, such as furnace areas. The overall jacket material should be moisture resistant, abrasion resistant and compatible with the environment and flame retardant specified as per IEC 60332. ‘The preferred shielding is aluminized polyester film with an overall spiral wrap that has 25 present overlap. The shield should be electrically in contact with a copper drain wire that is along the pair of wires. The shield should be electrically insulated both inside and outside. ‘Twisted wire should have a minimum of 20 crossovers per meter. For wire pair identification, number coding or color coding shall be used. For all shielded cables, shield shall be insulated from the metal armour. Tor individual and overall shielded cables, each individual shield shall be insulated from others and from the averall shield For cables to be installed on trays, the over sheath shall be made of flame retardant PVC or an elastomeric compound and resistant to petroleum products, which satisfies the requirements of IEC 60332. The armour shall be galvanized round steel wire supplemented by a helix of galvanized steel tape to keep the armour wires tight. The thickness of the galvanized steel tape shall be 0.3 mm. An overall jacket shall be provided for the cable. Specification for LAN and IP Telephone System Cable LAN and IP Telephone system cable shall be CAT6 4-pairs UTP Cable. © Conductor material : plain annealed copper meet the norms 23AWG. © Conductor structure: class 1 © Diameter of conductor: 0.57mm, meet the norms 23AWG_ © Insulation material: HDPE . Color of insulation: White/Green, Green, White/Orange, Orange, White/Blue, Blue, White/Brown, Brown © Nominal thickness of insulation: 0.2mm © Outer sheath material: PVC © Color of outer sheath: grey © Nominal thickness of outer sheath: 0.5mm © Nominal overall diameter of cable: 6.53mm BASIC DESIGN DOC. NO.: GEN-TEL-SPC-0013 REV. B PAGE 12 OF 20 43 Minimum cable bending radius: 43mm Approximate cable weight: 20.0kg/km DC resistance of conductor at 20 °C: <7.50/100m Voltage test: 1.5Kv, 2sec, without breakdown Normal operating temperature: 70°C Specification for CCTV System Power Cable CCTV System Power Cable shall be Armoured Antilaming Cross-Linked Polyethylene Power cable 3X25 (ZR-YJV32 300/500V 3°2.5) Conductor material: plain annealed copper Conductor structure: class 2 Conductor cross section: 32.5 mm2 Diameter of conductor: 2.04mm Insulation material: XLPE Color of insulation: Red, Yellow, Blue Nominal thickness of insulation: 0.7mm Inner sheath material: ZR-PVC Nominal thickness of inner sheath: 1.2mm Inner Covering: PVC Extruded Armoring Type: Galvanized steel wire Nominal Thickness of Armor Material: 0.8mm Outer sheath material: ZR-PVC Color of outer sheath: Black Nominal thickness of outer sheath: 1.8mm Nominal overall diameter of cable: 17.5mm_ Minimum cable bending radius: 263mm Approximate cable weight: 467kg/km DC resistance of conductor at 20 ‘C: <7.410/km Voltage level: 300/500V Voltage test: 3.5kV, Smin, without breakdown Normal operating temperature: 90°C BASIC DESIGN DOC. NO.: GEN-TEL-SPC-0013 REV. B PAGE 13 OF 20 4.4 Specification for PAIGA System Cable aA 1.outside power cable and audio cable (Armoured Anti-flaming fire resistant Cross-Linked Polyethylene Power cable 3X2.5 (ZR-YJV32 300/500V 32.5) Conductor material : plain annealed copper Conductor structure: class 2 Conductor cross section: 32.5 mm2 Diameter of conductor: 2.04mm Insulation material: XLPE Color of insulation: Red, Yellow, Blue Nominal thickness of insulation: 0.7mm Inner sheath material: ZR-PVC Nominal thickness of inner sheath: 1.2mm Inner Covering: PVG Extruded Armoring Type. Galvanized steel wire Nominal Thickness of Armor Material: 0.8mm Outer sheath material: ZR-PVC Color of outer sheath: Black Nominal thickness of outer sheath: 1.8mm Nominal overall diameter of cable: 17.5mm Minimum cable bending radius: 268mm Approximate cable weight: 467kgikm DC resistance of conductor at 20 °C: <7.410/km Voltage level: 300/500V Voltage test: 3.5kV, 5min, without breakdown Normal operating temperature: 90°C 2. outside signal cable (Armoured Anti-flaming fire resistant signal cable 2x2.5 (ZR-KYJVP32 300/500V 22.5) Conductor material: plain annealed copper Conductor structure: class 2 Conductor cross section: 22.6 mm2 Diameter of conductor: 2.04mm Insulation material: XLPE Color of insulation: Brown, Blue BASIC DESIGN DOC. NO.: GEN-TEL-SPC-0013 REV. B PAGE 14 OF 20 45 Nominal thickness of insulation: 0.7mm. Inner sheath material: ZR-PVC. Nominal thickness of inner sheath: 1.0mm Inner Covering: PVC Extruded Screen: copper wire intertexture Armoring Type: Galvanized steel wire Nominal Thickness of Armor Material: 0.8mm Outer sheath material: ZR-PVC Color of outer sheath: Black Nominal thickness of outer sheath: 1.5mm Nominal overall diameter of cable: 17.0mm Minimum cable bending radius: 204mm Approximate cable weight: 470kg/km DC resistance of conductor at 20 ‘C: <7.410/km Voltage level: 300/500V Voltage test: 3.0kV, 5min, without breakdown Normal operating temperature: 90°C Specification for Fire Alarm System (FAS) Cable inside signal cable: Anti-flaming fire resistant signal cable 2X 1.0 (ZR-RVVS 21.0) Conductor material: plain annealed copper Conductor structure: class 5 Conductor cross section: 21.0 mm2 Diameter of conductor: 1.3mm Insulation material: PVC. Color of insulation: Brown, Black Nominal thickness of insulation: 0.8mm Outer sheath material: ZR-PVC Color of outer sheath: Black Nominal thickness of outer sheath: 1.0mm Nominal overall diameter of cable: 8.2mm, Minimum cable bending radius: 65mm BASIC DESIGN DOC. NO.: GEN-TEL-SPC-0013 REV. B PAGE 15 OF 20 46 eeoecec rere eoererereceeceereeceeece Approximate cable weight: 82kg/km DC resistance of conductor at 20 0: <19.50/km Voltage level: 300/500V Voltage test: 2.0kV, 5min, without breakdown Normal operating temperature: 70°C 2. outside signal cable and power cable: Armoured Antislaming fire resistant signal cable 22.5 (ZR-KYJVP32 300/500V 2'2.5) Conductor material : plain annealed copper Conductor structure: class 2 Conductor cross section: 22.5 mm2 Diameter of conductor: 2.04mm Insulation material: XLPE Calor af insulation: Brown, Rie Nominal thickness of insulation: 0.7mm Inner sheath material: ZR-PVC. Nominal thickness of inner sheath: 1.0mm Inner Covering: PVC Extruded ‘Screen: copper wire intertexture Armoring Type: Galvanized steel wire Nominal Thickness of Armor Material: 0.8mm Outer sheath material: ZR-PVC Color of outer sheath: Black Nominal thickness of outer sheath: 1.5mm Nominal overall diameter of cable: 17.0mm Minimum cable bending radius: 204mm Approximate cable weight: 470kgikm DC resistance of conductor at 20 °C: <7.410/km Voltage level: 300/500V Voltage test: 3.0kV, 5min, without breakdown Normal operating temperature: 90°C Specification for Access Control System (ACS) Cable inside signal cable: signal cable 61.0 CYJV 300/500V 6x 1.0) BASIC DESIGN DOC. NO.: GEN-TEL-SPC-0013 REV. B PAGE 16 OF 20 47 Conductor material : plain annealed copper Conductor structure: class 2 Conductor cross section: 61.0 mm2 Diameter of conductor: 1.29mm Insulation material: XLPE Color of insulation: White with black number Nominal thickness of insulation: 0.6mm Outer sheath material: PVC Color of outer sheath: Black Nominal thickness of outer sheath: 1.2mm Nominal overall diameter of cable: 11.8mm Minimum cable bending radius: 142mm Approximate cable weight: 158kg/km DC resistance of conductor at 20 °C: <10.10/km_ Voltage level: 300/500V Voltage test: 3.0KV, 5min, without breakdown Normal operating temperature: 90°C Specification for other Cable 1. signal cable: Armoured Anti-flaming signal cable 4% 2.5 (ZR-YJV32 300/500V 4 x25) Conductor material: plain annealed copper Conductor structure: class 2 Conductor cross section: 42.6 mm2 Diameter of conductor: 2.04mm Insulation material: XLPE Color of insulation: Blue, Brown, Black. Grey Nominal thickness of insulation: 0.7mm Inner sheath material: ZR-PVC Nominal thickness of inner sheath: 1.0mm Inner Covering: PVC Extruded Armoring Type: Galvanized steel wire Nominal Thickness of Armor Material: 0.8mm BASIC DESIGN DOC. NO.: GEN-TEL-SPC-0013 REV. B PAGE 17 OF 20 Outer sheath material: ZR-PVC Color of outer sheath: Black Nominal thickness of outer sheath: 1.5mm Nominal overall diameter of cable: 18.4mm. Minimum cable bending radius: 221mm Approximate cable weight: 616kg/km DC resistance of conductor at 20 ‘C: <7.410/Km Voltage level: 300/500V Voltage test: 3.0kV, 5min, without breakdown Normal operating temperature: 90°C . power cable: power cable 3X2.5 (YJV 300/500V 3x2.5) Conductor material : plain annealed copper Conductor structure: class 2 Conductor cross section: 3x2.5 mm2 Diameter of conductor: 2.04mm Insulation material: XLPE_ Color of insulation: Red. Yellow. Blue Nominal thickness of insulation: 0.7mm. Outer sheath material: PVC Color of outer sheath: Black Nominal thickness of outer sheath: 1.8mm Nominal overall diameter of cable: 12.6mm. Minimum cable bending radius: 189mm Approximate cable weight: 191kgikm DC resistance of conductor at 20 ‘C: <7.410/Km Voltage level: 300/500V Voltage test: 3.5kV, 5min, without breakdown Normal operating temperature: 90°C . power cable: power cable 22.5 (YJV 300/500V 22.5) Conductor material: plain annealed copper Conductor structure: class 2 Conductor cross section: 22.6 mm2 BASIC DESIGN DOC. NO.: GEN-TEL-SPC-0013 REV. B PAGE 18 OF 20 Diameter of conductor: 2.04mm Insulation material: XLPE Color of insulation: Brown, Blue Nominal thickness of insulation: 0.7mm Outer sheath material: PVC Color of outer sheath: Black Nominal thickness of outer sheath: 1.2mm Nominal overall diameter of cable: 10.9mm Minimum cable bending radius: 131mm Approximate cable weight: 134kg/km DC resistance of conductor at 20 C: <7.410/km Voltage level: 300/500V Voltage test: 3.0kV, Smin, without breakdown Normal operating temperature: 90°C 5.0 CABLE MARKING The outer sheath of cable shall be legibly and permanently marked by indelible printing or embossing at regular intervals with marks to distinguish the following data as a minimum: Manufacturer's name and year of manufacture Voltage grade (specified voltage) Number of core and core sizes Cable type Quality of outer-sheath 6.0 CABLE CONSTRUCTION Tagging and identification shall be in accordance with Equipment and Document Numbering Procedure. Identifications printed onto individual core insulation shall be permanent and abrasion resistant ‘The final cable make-up shall be homogenous and circular in cross section. No splices are permitted in any cable conductors. Continuous conductors shall be used. 7.0 INSPECTION AND TESTING The cable shall be thoroughly ‘ested as a pre condition for acceptance. The Acceptance Tests shall be conducted in two stages as follows: BASIC DESIGN DOC. NO.: GEN-TEL-SPC-0013 REV. B PAGE 19 OF 20 © The Factory Acceptance Test (FAT); @ The Site Acceptance Test (SAT). The contractor shall submit for purchaser's review and approval, a complete plan for the factory and site acceptance testing. This plan must be complete with sufficient detail to indicate the exact nature of each test, time required, expected results and step-by-step procedure. The plan shall be submitted at least four weeks in advance to the FAT. The objective of the FAT is to verify that the cable as designed for delivery to site meets or exceeds the specified requirements. Inspection and testing of the cable shall meet the requirements as per the ‘Standards and Specifications listed in Section 2. 8.0 GUARANTEE AND WARRANTY ‘Any cables purchased under this specification shall be provided in accordance with the purchaser's order terms and conditions. The cable vendor shall disclose to the purchaser each proposed design. manufacturing procedure, material, component. or assembly which does not have at least 2 years satisfactory field-operating track record in a similar service. Fielc experience shall be at least as severe as the proposed conditions, Failure to make such disclosure prior to accepting a purchase order, specifically and in writing, shall both: Extend the vendor's warranty for a further two years Expand the vendor's warranty obligations to include payment of all direct costs to the Purchaser that may result from vendor use of such procedures, components, materials, or assemblies. Direct costs include (but are not limited to) the following: © Replacement parts © Field labour required for removal and re-installation © Factory labour to complete repairs © Shipping and freight ‘© Engineering Inspection and testing. 9.0 QUALITY ASSURANCE ‘The cables shall be in accordance with the listed codes and standards in Section 2. Vendor shall be regularly engaged in manufacture of Telecommunication Cables of similar type, size and electrical characteristics and those products have been in ‘satisfactory used in similar services for not less than 3 years. 10.0 DOCUMENT REQUIREMENT Each document submitted for review must be clear, legible, complete and properly identified. Failure to provide adequate documents may result in them being returned without review at Vendor's expense. In that event, Vendor will be considered not to have formerly submitted the documents. BASIC DESIGN DOC. NO.: GEN-TEL-SPC-0013 REV. B PAGE 20 OF 20 Drawings and data approval does not relieve Vendor of his responsibility to meet purchase order or contract conditions relating to specifications, material and delivery requirements, nor relieve Vendor of responsibility for compliance with laws, codes and regulations. The vendor shall submit with the tender the information below for each type of cable supplied: . Standard drum length. Maximum and minimum manufacturing drum length and weights of individual drums for each type of cable. . Number and size of conductors making up the cross-sectional area of each core. Sectional drawing of cable construction shall be provided during bidding. Insulation thickness. Inner sheath diameter with maximum tolerance. Over sheath diameter with maximum tolerance. ‘Armour thickness. ‘Armour diameter. Minimum installation temperature. Minimum bending radius at minimum installation temperature. Weight per kilometre. Current carrying capacity with specified ambient and installation conditions. Rated conductor temperature. Maximum conductor temperature. Resistance per kilometre. Reactance per kilometre. Short circuit withstand capacity. Voltage drop per A/km. List of drums per cable, Any information for glands For fire resistant cables: fire resistance behaviour (temperature/duration) eoereerereccee 11.0 DELIVERY, STORAGE AND HANDLING The Contractor shall handle all the cables carefully at all times to prevent damage, breaking and scoring. The Contrector shall not install damaged cables. All the cables shall be stored in sheltered areas and covered to prevent exposure. All the cables shall be stored in a clean, dry environment where it is protected from weather, dirt, fumes, water, construction debris, and physical damage.

You might also like