Professional Documents
Culture Documents
TRANSFORMER
TRANSFORMER
TRANSFORMER
'
".: ,,'"".
21st CENTURY SHIPBUILDING CO" LTD.
SHIP No,
CSN-253/254/255/256/257/258
.~
. ,
CLASS
"
ABS
TITLE
.' ,
TRANSFORMER
,
IMO-94,39319
;
, 1)·'
\ .....
..... I) ..
I' .
. ':
R FINALI
. 1
~.~<_._-
, ' ,
Ir'.,,'"'
,I
I
. I'
.
)
I" V
L..
.4. . -
TOTAL ( 11 ) SHEET W'ITH A COVER
APPROVED C J H J YOO
;'0'" .r"
o ,
CHECKED BY
,
, "
DESIGNED BY H, /lHN
",
••
,
... JO'.
. ",.
,"
, '
'
M£-.Llt DWG. No.
SHE -CSN253TR
.' ,
00
583-12,JANGLIM-DDNG,SAHA-GU,KDREA
SHE CO. , LTD. TEL. (081) 281-8923-5
FAX. (081) 281·8926
,
'.
'
031
GENERAL SPECIFlCAnON
1. GENERAL
This specification is for the dry-type marine transformer, designed and manufactured
to comply with yard requirements, classification and maker's standard sepciflcation In
order to endure worst sea condition during long voyage and vibration shock, salinity and
ambient temperature changes etc.
2. CONSTRUCTION
a) TRANSFORMER ENCLOSURE
Transformer enclosure conslructed of mild sleel will be so designed as 10 allow Ihe
complele Iransformer in Ihe enclosure' 10 be lifted by crane and transported by ship
or vehicle wlthoul overslrainlng any Jolnls.
Transformer enclosure will be provided 10 sufficiently cool down the heal generaled by
transformer losses
b) TERMINAL BOARD AND OTHER FITTINGS
Terminal board is connecled to primary and secondary voltage, and also olher necessary
parts such as lifting eyes on the enclosure are furnished, if needed.
3. ROUTINE TESTS
The following tests will be carried oul al maker's works with the presence of yard
Inspector and owner's aulhorized agent, and Ihe records of such testing will be submitted
to the yard
a) Structure check
b) Reslslance measurements of Ihe windlngs
c) Insulation resistance measurements
d) Ratio lesl{1/100), polarity & phase tesl
e) No load loss and currenl measuremenls
f) Load loss and impedance voltage measurements
g) Applied voltage lesl (lmlnute) 445/225V
p-e : 2.5kV
s-e : 2.5kV
rated frequency
h) induced vollage test : 120 x (sec)
lest frequency
I) Temperature rise test: (only one fransformer in each group)
The tesl will be carried out by IEC, Ihe Inspector before
buyer's/owner's Inspection In order 10 save Ihe inspection time.
And Ihe resull to be reviewed only by buyers/owner's inspector.
MODEL IMA-575
• • c
"''"
I
• BBO
+
I
I 4 rt: --t:,
•• •
c , c ,
e , e- r- ,
LP
e
31-
L --"
~
t- c --"
c
c
'" c
~
e , e , c
e , e , c
--"
--"
c
•
I
~
l+f 20
~1\I\
30
I 700("'3>
EARTH LINER
4-1116 'ITT.HOLES
400<D3>
500
BOO
..NOTE..
TOLERANCE, '-.13, D3 I ±I%
OTHER I ±5%
R S T
0) (0 0
3 2 1 3 2 1 3 2 1
Primary
llltJlllllllllr llltJlllllllllr Illtl JIIIIIIIII r
L
IIIIIIIIIIII JIIIIIIIIIII ffilllllllllL
Secondary
L
0 0 (0
U V W
Terminal Board
2 2 2
I . . .
u V w
I
Model Copacity Volt Current Cable gland
Primary 445 V 97.31 A 45AxlE
IMA-575 75 kVA Secondary .Q? A<A
225 V 45A x 2 E
Top Voltage
I Conneclion I R.S.T-3 I R.SJ-2 I R.S.T-l I
I Volt I 450V I R445V I 440V I
CERTIFICATE
CLASS I I
TN-02-4A
TRANSFORMER
Type/Encl. IDRY!IP- 23 I Capacity I 75 kVAI
Pri. Volt. I 445 V I Sec. Volt. I 225 Vi
Pri. Amp.1 97.31 A I Sec. Amp.1 192.45 AI
Frequency I 60 Hzl Phase I 3 PHI
Conn. I D-D I % Imp. I %1
~
Insu. Clos~ F I Amb. Temp~ 45 'cl ~
Rule Closs I
ASS I Weight I 370 kgl
Ser. No. I SM.153-1,2 I Date I 2008. I
R S T
_a~~d~
TAP
CONN.
Volt
450 V R.SJ-3
Secanda~riiiiiiillliJfiiiiiilllii¥iiiiiiliiiiJ
R445 V R.SJ-2
440 V R.SJ-l
u v w
I. E. C
F,)) PUSAN KOREA T.051)264-S222 "
,no
,n
•• NOTE ..
MATERIAL: SUS 304
MOOEL IMA-330
SIDE VIEW
FRONT VIEW
8
r - 3
n n /RI /RI
<-----.;>
<-----.;>
~~
<-----.;>
<-----.;> :i .- •
<-----.;> "---'>
-
0
0
I I " "'" I I
<-----.;>
<-----.;>
"
<-----.;>
<-----.;>
"---'>
"---'>
<-----.;>
<-----.;>
iJ I
900(D3) / 1\ EARTH
320(D3)
1050 7 UN ER
370
1110 / 430
14-016 FITTING HOLES
nNOTEn
TOLERANCE I 1,/3, D3 I ±l%
OTHER I ±5%
CONNECTION DIAGRAM
R
S
T
~~JJ ~~IIIU
Ul 123, VI 2 V3
Primary
1",J,l ttllr UIIII/ Ulllr
mm mm !fTTT1l ,mm ,mnn. lffiTTl
Secondary ,1 ,2 u3 , u3 ,3
ul ,1 ul u2 u2
U
V
W
IT - 1 IT - 2 TF - 3
Usually Connection
t:, - t:,
Top Volf0ge(Primory)
I
I Connection
Volt
2- 3
(50 V I 2- (
R«5 V I 1- (
((0 V I
j Usually Connection
Primary Secondarv
Unes Connect Unes Connect
R VI - U2 U ,1 - u2
t:, t:, S V2 - U3 V v2 - u3
T V3 - Ul W ,3 - ul
I ¥";
APPROVED SCALE TITLE
REVISION USUALLY CONNECTION DIAGRAM FOR
&, DESIGNED DATE TRANSFORMER (30kVA, lPH X 3EA)
.6>
£
A OOSHE CO. , LTD.
DWG No.
CSN253TR I No. I
I SHEET 6
CONNECTION DIAGRAM
Emergency Conneellon R
V V .
=et
~ ~~~-::I
Pnmo~
~~~
ikJ U tJmJ
-1JQOO
Usually Conneellon 6. - 6.
R
S
T--.-----+-+----++-----r-
Ul I 23, VI U2 123 , V2 U3 123 , V3
Primo~
1,IIIUUIIIII lllllLI UIIII lllllU f,!lIllr
Primo~ Secondary
Condition Unes Connect Unes Conneel
R U2 - U u2 -
Tf - 1 Trouble S V2 - U3 V v2 - u3
T - V3 W - v3
R U3 - U u3 -
Tf - 2 Trouble S V3 - Ul V v3 - ul
T - VI W - vI
R Ul - U ul -
Tf - 3 Trouble S VI - U2 V vI - u2
T - V2 W - v2
TAP
Volt
CONN.
450 V 2-3
tiiliJbiWtLJ
Prima!
~con~a~
R445 V 2-4
440 V 1-4 w If-I 1f-2 1f-3
un
.. NOTE ••
MATERIAL: SUS 304
I'
,,
IW~
1
• ~~ :§:lA} SHE
-¥-1t~At : -¥-,1fAl Ari>t-=f- ~'i:l% 538-12
538-12, JANGLIM-DONG, SAHA-GU, BUSAN, KOREA
TEL: 051-261-8924/25
FAX: 051-261-8926
l8-~ iPJ : ~\f l8-~Al :£AJ-~ -¥l-"Q}Cl 693-6
693-6 KWANDUK-RI, DOSAN-MYEN, TONGYEONG, KYEONGNAM, KOREA
TEL:055-644-6541
FAX: 055-644-5178
I.
•