Professional Documents
Culture Documents
Full download Electrical and Mechanical Fault Diagnosis in Wind Energy Conversion Systems Monia Ben Khader Bouzid file pdf all chapter on 2024
Full download Electrical and Mechanical Fault Diagnosis in Wind Energy Conversion Systems Monia Ben Khader Bouzid file pdf all chapter on 2024
https://ebookmass.com/product/mechatronics-electronic-control-
systems-in-mechanical-and-electrical-engineering-7th-edition-
william-bolton/
https://ebookmass.com/product/mechanical-and-electrical-systems-
in-architecture-engineering-and-construction-5th-edition-ebook-
pdf-version/
https://ebookmass.com/product/electrical-systems-2-from-
diagnosis-to-prognosis-hubert-razik/
https://ebookmass.com/product/thermal-mechanical-and-hybrid-
chemical-energy-storage-systems-klaus-brun-editor/
Electrical Systems 1 From Diagnosis to Prognosis Hubert
Razik
https://ebookmass.com/product/electrical-systems-1-from-
diagnosis-to-prognosis-hubert-razik/
https://ebookmass.com/product/nanostructured-functional-and-
flexible-materials-for-energy-conversion-and-storage-systems-1st-
edition-alagarsamy-pandikumar/
https://ebookmass.com/product/mechanical-and-electrical-
equipment-for-buildings-12th-edition-ebook-pdf/
https://ebookmass.com/product/innovative-energy-conversion-from-
biomass-waste-arif-darmawan/
https://ebookmass.com/product/data-driven-and-model-based-
methods-for-fault-detection-and-diagnosis-majdi-mansouri/
Electrical and Mechanical Fault Diagnosis in
Wind Energy Conversion Systems
Electrical and Mechanical
Fault Diagnosis in Wind
Energy Conversion Systems
Edited by
Apart from any fair dealing for the purposes of research or private study, or criticism or review, as
permitted under the Copyright, Designs and Patents Act 1988, this publication may only be reproduced,
stored or transmitted, in any form or by any means, with the prior permission in writing of the publishers,
or in the case of reprographic reproduction in accordance with the terms and licenses issued by the
CLA. Enquiries concerning reproduction outside these terms should be sent to the publishers at the
undermentioned address:
www.iste.co.uk www.wiley.com
Any opinions, findings, and conclusions or recommendations expressed in this material are those of the
author(s), contributor(s) or editor(s) and do not necessarily reflect the views of ISTE Group.
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Monia BEN KHADER BOUZID and Gérard CHAMPENOIS
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205
Introduction
Wind energy plays a vital role in meeting the Paris Agreement’s goal of
1.5°C global warming and to accelerate the energy transition. In fact, wind
energy is a renewable and sustainable source of energy, which does not
contribute to greenhouse gas emissions, making it an important tool in
combating climate change. As the cost continues to decrease significantly
and technology improves, wind energy is becoming more competitive with
other sources of energy an increasingly important part of the global energy
mix.
produced by the generator into a form that can be used by the grid or stored
in batteries and the control system responsible for regulating the speed and
direction of the rotor blades to optimize the efficiency of the wind turbine.
1.1. Introduction
As the generator and its associated converters are the main electrical
components in the energy conversion process of a wind turbine system
(Bahloul et al. 2023), this chapter is focused on the detection of the inter-turn
short-circuit fault (ITSCF) in the stator windings of the permanent magnet
synchronous generator (PMSG) and the open-circuit diode fault (OCDF) in
the three-phase diode rectifier connected to the PMSG. Each type of fault
can occur separately or two may occur simultaneously. In the case of a
simultaneous fault, it is very difficult to discriminate between the two faults.
To this end, this chapter proposes an efficient method based essentially on
the symmetrical components to detect, locate and discriminate between an
ITSCF and an OCDF in a small-scale, variable-speed wind energy
conversion system.
1.2. Description of the system under study and the used fault
detection method
On the other hand, the wind turbine generator is interfaced with the utility
grid via power electronic converters used to transfer and control the wind
power into the electric grid. Typically, wind turbine converters include diode
rectifier-based converter topology, two-level back-to-back converter
topology, three-level neutral-point-clamped back-to-back converter topology
and modular multilevel converter topology (Yang et al. 2016). It has been
reported in Liang et al. (2022) that the fault of power semiconductor devices
is one of the main causes responsible for converter faults. Typical faults of
power semiconductor devices can be divided into short-circuit (SC) faults
and open-circuit (OC) faults. The OC faults are the most common.
Figure 1.1. Small-scale, PMSG variable speed wind energy conversion system
To ensure the reliability and increase the safety of the system under
study, this work is aimed at finding an efficient method capable of detecting,
locating and discriminating between two electrical faults, which are an inter-
turn short-circuit fault (ITSCF) in the stator of the PMSG and an OCDF in
the three-phase diode bridge rectifier. This interest is justified by the fact that
the ITSCF is the most frequent fault in the machine (Qiao and Lu 2015), and
it is a critical and harmful one when detected in the PMSG. It shapes more
than one-third of the total faults in the PMSG (Sayed et al. 2021). However,
the OCDF in a diode rectifier, although it may not seriously stop the
operation of the wind turbine system, can result in overstressing the other
healthy diodes and cause the failure of other diodes (Huang et al. 2021).
The proposed fault detection and diagnosis method are based on the
monitoring of different relevant indicators of faults extracted basically from
the symmetrical components of voltages and currents. It consists first of
monitoring the magnitude of the PMSG NSV V2 to detect any fault in the
considered system. Afterward, the mean values of the line currents are used
to discriminate between an ITSCF and OCDF since a fault can occur in the
PMSG or the rectifier. Furthermore, in the case of an ITSCF or/and an
OCDF, the location of the PMSG faulty phase or/and the rectifier’s faulty
arm is ensured by the monitoring of the phase angle φV2 of the NSV and the
phase angle φI2 of the negative sequence current (NSC), respectively. The
potential features of these indicators to detect, discriminate and locate
the considered faults will be demonstrated in the next sections through an
Accurate Electrical Fault Detection 5
original deep and thorough analytical study of the NSV under the different
faults where novel NSV expressions will be developed and presented taking
into account the encroachment effect of the current and the placement of the
different turns in the slots of the PMSG stator. The behavior of the NSV and
the NSC as well as the exactness of the proposed novel expressions will be
validated for each fault. However, before investigating the analytical
behavior of the NSV under ITSCF and OCDF, let us give first, a brief
description of the symmetrical component principle.
1 a a2
F = 1 a 2 a [1.1]
1 1 1
V1 1 a a 2 Va
1 2
V2 = 3 1 a a . Vb [1.2]
V0 1 1 1 Vc
I1 1 a a 2 Ia
1 2
I2 = 3 1 a a . Ib [1.3]
I0 1 1 1 Ic
2π 4π
j j
where a = e 3
and a 2 = e 3
.
Another random document with
no related content on Scribd:
in cerebral meningeal hemorrhage,
415
syphilis,
1016
722
in chronic lead-poisoning,
691
in epilepsy,
502
201
710
in multiple neuritis,
1198
in neuritis,
1194
in spinal sclerosis,
900
989
in tubercular meningitis,
736
762
use of, in acute spinal meningitis,
752
753
756
829
643
in catalepsy,
338
in chorea,
455
in chronic hydrocephalus,
745
in hysteria,
278
in hystero-epilepsy,
313
in neuralgia,
1224
756
in tubercular meningitis,
735
Irritability in tubercular meningitis,
725
727
1235
220
221
J.
868
226
252
in tabes dorsalis,
830
837
of chronic lead-poisoning,
684
Jumpers, the, hysterical nature of,
227
Jumping chorea,
244
K.
Katatonia,
166
327
613
662
654
221
86
71
Kleptomania,
147
195
868
in chorea,
448
888
in disseminated sclerosis,
875
in epilepsy,
481
in hemiplegia,
962
in nervous diseases,
152
862
in spinal syphilis,
1025
in tabes dorsalis,
829
835
,
857
858
664
1092
265
266
L.
ABIO-GLOSSO-LARYNGEAL
ARALYSIS
,P
ROGRESSIVE
1169
Definition,
1169
Diagnosis,
1174
Etiology,
1173
History,
1169
Pathological anatomy,
1172
Symptoms,
1170
1170
1171
Deglutition, difficult,
1170
Facial expression,
1170
Heart, disorders of,
1170
1172
1171
1170-1172
Synonyms,
1169
Treatment,
1174
Diet,
1175
Electricity,
1175
1175
568
Laryngeal vertigo,
425
607
Lateral sclerosis,
861
689
EAD-POISIONING
,C
HRONIC
678
680-682
Diagnosis,
690
Etiology,
679
680
Exciting causes,
680
681
679
,
680
689
Prognosis,
684
687
689
Symptoms,
682-689
Albuminuria in,
689
Amaurosis in,
689
Bluish line upon gums, significance of,
682
Disturbances of nutrition,
682
in animals,
690
of lead colic,
683
of the arthralgia,
684
of the encephalopathy,
688
of the paralysis,
685
Synonyms,
678
Treatment,
690
Alum, use,
691
691
691
691