Sta Rite Pool Heater Ignition Lockout [9
Easy Fixes]
May 16, 2022 by David
Recent Posts

Sta Rite pool heater ignition lockout happens when your heater has tried to fire Truma Water Heater Not
up 3 times and consecutively failed. Getting Hot [How To Fix]

When your heater is in a lockout, you can’t operate it without fixing the problem Truma Water Heater Reset

and resetting it. So, you have to identify the cause of ignition failure and fix it Button [How To Reset]

before resetting the system. Navien Tankless Water Heater

Standby Mode [Explained]

The possible causes of ignition failure are- failed ignitor, bad ignition Richmond Tankless Water
control module, defective flame sensor, blower not working, blocked Heater Code 29 [Reasons +
pool filter, low pump pressure, damaged gas valve, clogged burner Solutions]
orifice, and tripped safety switches.
Richmond Tankless Water

Heater Code 13 [Reasons +


Keep reading our Sta-Rite pool heater troubleshooting guide to get your heater Solutions]
out of the ignition lockout ASAP.

Table Of Contents

Sta Rite Pool Heater Ignition Lockout [9 Easy Fixes]

1. Failed Ignitor
···
2. Bad Ignition Control Module
3. Defective Flame Sensor

4. Blower Not Working


Earning Discloser
5. Blocked Pool Filter

6. Low Pump Pressure


7. Heaterfixlab.com is a

Damage participant in Google Adsense

d Gas and Ezoic Ad Network. We


Valve receive monetary benefits in

return for showing ADs on this

··· website at no cost to you.

···
···

8. Clogged Burner Orifice

9. Tripped Safety Switches

FAQs:

Why is my heat pump fan not turning?

Does a pool heater have a pilot light?

What does a thermistor do in a pool heater?

···

How much does it cost to install a solar pool heater?

Why is my pool heater not heating?

Conclusion

Sta Rite Pool Heater Ignition Lockout [9 Easy


Fixes]
When your heater is in ignition lockout, the diagnostic LED flashes 3 times to
indicate that the system is in ignition lockout.

So, if that is happening, you can be sure your heater has one of the following

issues that we will take a look at in detail. We will also share the simplest
solution with you.

1. Failed Ignitor 

The ignitor creates a spark to directly light up the burner. Therefore, with a failed

ignitor, your heater’s burner won’t light. Your heater LED indicating 3 flashes

ignition lockout can be happening because of a failed igniter.

···

Solution:

You need to access your heater ignitor and look for any signs of physical damage.
If the ignitor is twisted, chipped, cracked, or damaged, it should be replaced.

Use pliers to remove the plug on the wires to detach them from their sockets
within the pool heater if there was no evident damage to the ignitor. You need a

multimeter to test the ignitor for continuity.

First, make sure the multimeter is tuned to the lowest resistance test. The probes

should then be connected to the igniter plug’s tips.

The ignitor is faulty and has to be changed if the multimeter shows a reading of

infinity or zero.

2. Bad Ignition Control Module


The Ignition Module employs a microprocessor to continuously and safely

monitor, evaluate, and control the gas flame holder’s appropriate performance.

The heater can run only after the ignition control module allows it to. So, a

malfunctioning ignition control module can be why your Sta Rite pool heater
won’t ignite.

···

Solution:

You need to replace the ignition control module, ICM, to solve this issue. The

Sta-Rite ignition control module replacement process is given below.

To access the ICM, your heater’s left side panel needs to be removed. Take

a picture of the wire connections to the ICM to remember where each wire
goes. Disconnect the wires connecting the ICM to the Max-E-Therm

heater.
Detach the old ICM and take the new one and insert it in the heater’s

junction box chamber. Connect the wires to the new ICM referencing the
picture you took. Put everything back together when done.

3. Defective Flame Sensor

The flame sensor is utilized as a gas leak detector. The ignition control uses the
flame sensor, which is an electrode, to identify the “rectification” of current

passing through the flame.

The gas valve opens to light the burners only after detection. The Sta-Rite pool

heater will not ignite if the flame sensor begins to malfunction.

Solution:
To see if the flame sensor is sending a signal to the gas valve, connect a

multimeter capable of measuring microamps (A) in series between the wires


feeding into the gas valve and sensor terminal. The electric supply must be

switched on while doing this test.

···

Connect the lead from the flame sensor to any one of the meter’s probes. Attach
the sensor terminal to the meter probe on the other side.

Adjust the thermostat higher and check the reading once the burners have
ignited. The reading should be in the range of 5 to 10 A. If it reads less than that,

the sensor is bad and needs to be replaced.

4. Blower Not Working

A malfunctioning blower can be why your heater is failing to ignite. Without the

blower operating, the heater won’t get enough airflow.

···

This increases the chances of the pool heater overheating. That’s why the
heater won’t ignite.
Solution:

Verify that the fan is running. If not, the blower motor could be broken. The

issue could possibly be with the wiring, or the blower could be receiving
insufficient voltage.

You must determine which of these issues is causing the blower to malfunction.

Look at the Sta-Rite pool heater wiring diagram below to verify the connections.

···

Sta-Rite pool heater wiring diagram

5. Blocked Pool Filter

A pool filter can easily get clogged with debris and dirt which limits the water

flow of the pool heater. Your heater needs a minimum water flow rate to operate.

So, this can be why it won’t ignite.

Solution:
You need to check your pool filter to see if the elements are dirty. Backwash the
pool filter if they appear dirty. Clean out the pool skimmer basket.

It is very important that you clean the pool filter every 2-3 months. Most pool

heater issues are caused by a clogged pool heater.

···

6. Low Pump Pressure

Low pump pressure can cause ignition failure. If your pump pressure reading is

lower than required, the following things may be wrong.

Pump and Skimmer Baskets are Clogged up

Reduced water level


···

Skimmer lines clogged


Pool Pump Impeller Clogged or Damaged

there is a leak in the water pump inlet lines

···

The pressure gauge is broken.


Multiports or 3-way valves are leaky

Solution:

Make sure that the skimmer basket is empty and the lines aren’t clogged. Check

the pool pump impeller for damage and replace it if necessary. Clean the

impeller up if dirty.

···

Verify that the water level is appropriate and the lines going into the pump are
not cracked or damaged in any way.
Bleed out the pump in case there are air leaks. Replace the pressure gauge that is

broken. Replace the multiports or 3-way valves if the issue is still not fixed.

7. Damaged Gas Valve

The gas valve controls the amount of gas that enters the manifold. It only

permits flow when the temperature control system demands heat and all safety

precautions have been taken. As a result, if your gas valve fails, your heater will

not turn on.

Solution:

Look for the two wires connected to the solenoid terminals on the top or side of

the gas valve. Disconnect the connections from the gas valve’s terminals.

Each wire is connected to a terminal via a push-on clip that can be withdrawn.
Note where the wires link to the valve so you may rejoin them later.

Set the test control on the multimeter to “mV.” Connect the multimeter’s tester

probes to every one of the gas valve’s terminals.

···

From 145 to195 millivolts is a common reading. The gas valve is defective if the

reported reading is not within this range. It will have to be replaced.

8. Clogged Burner Orifice

The burner opening could be obstructed by dust or calcium deposits. It may

make it difficult for the burners to light correctly and cause pool heater ignition

failure.

Solution:
You’ll need to repair the burner tube to get the pool heater working properly

again. To replace the tube on your own, follow these steps:

Shut down your pool heater and switch on a nearby tap for around five

minutes. Remove the lowest access panel from the water heater.

By unscrewing and removing the old tube’s base from the gas valve. The

burner tube should be replaced.


Reconnect the base of the replacement burner tube to the gas valve with

an adjustable wrench for a snug fit.

By turning on the water heater, you can see if it’s working properly. If the
problem persists, hire a mechanic to examine it thoroughly.

9. Tripped Safety Switches

The safety switches keep your unit safe from harm. When these switches identify

a fault with the pool heater, they trip and shut off the power.

Pressure switches, high-limit switches, automated gas shutoffs, and airflow

switches all have the potential to trigger for a number of reasons.

The air pressure switch and other safety switches must be closed for the ignition

module to work.

Solution:

You’ll almost likely get an error code if either of these safety switches trips. It’s

likely that the service heater light on the Sta-Rite will turn on.

The error codes indicate which safety switches are active. To reset the switch, you

must first figure out why it tripped. Your heater should be able to turn on after

you’ve reset the safety switch.

FAQs:

Why is my heat pump fan not turning?

If the compressor is operating but the fan is not, either the fan motor or the

capacitor has burned out. But first, make sure there’s no debris! If your blower is

too dirty it can affect its operation.


Does a pool heater have a pilot light?

A modern pool heater is likely not to have a pilot light. Instead, they have

electrical igniters that produce sparks to light up the burner.

What does a thermistor do in a pool heater?

The thermistor reads the temperature and determines whether the pool water

needs more heating or not to reach the set temperature. The thermistor 

determines whether the thermostat will call for heat or not.

How much does it cost to install a solar pool


heater?

The cost of purchasing and installing a solar pool heating system is typically
between $2,500 and $4,000. Depending on local fuel costs and solar resource

availability, this can pay for itself in 1 to 7 years.

Why is my pool heater not heating?

Insufficient gas pressure, low airflow, or a malfunctioning blower can contribute

to your heater not heating. Check that the gas is switched on and that the

propane tank is filled. Read our article on pool heaters not heating for more

details.

Conclusion

Now that you know what causes Sta-Rite Pool Heater Ignition Lockout,
hopefully, you will get your heater running in no time. In case you are having any

additional issues with your Sta-Rite pool heater, leave us a comment.

 Pool Heater
 Sta Rite Pool Heater Won’t Turn On [11 Easy Fixes]
 Raypak Pool Heater Won’t Ignite [9 Easy Fixes]

About David

David is a man who loves doing research and finding out the best solution to
any type of heating appliance issues like heaters and fireplaces. Whenever he
finds the perfect solutions to any issues of heating appliances after doing in-

depth research, he loves to share them with his readers. In fact, his aim is to

help his readers to fix the issues with their heating appliances easily.More

about us .

...

Leave a Comment

Name *

Email *

Website

Save my name, email, and website in this browser for the next time I

comment.

Post Comment

Sponsored Content Recommended by

The New Hyundai


Palisade SUV Will
Leave You Speechles…
Popular Searches

How Much Does It


Cost To Replace The
Roof In 2023? See Th…
Urologist: 87% of Men with E.D. Don't Know Roofing Services - Sponsored Li…
About This Easy Solution (Try Tonight!)
urologytip.pro

About Us II Contact Us II Privacy Policy


Facebook II Pinterest II Twitter

Latest news on Heaters and


Fireplace Fixes

your name

your email address

Subscribe Now!

COPYRIGHT © 2023. All Right Reserved by HeaterFixLab.

You might also like