4. Procedures
It is similar to the Proctor test, at this moment we do only 3 specimens which hit 10,
30, and 65 blows respectively.
1) First of all, we weighed water 3 jars of 720g corresponding to the OMC 12% gained from
the Proctor test. And cement 240g with 6kg of soil.
4) Use the proctor damn mixture 10 blows per layer till 5 layers and weigh it we get
𝒎𝒔𝒂𝒎𝒑𝒍𝒆+𝒎𝒐𝒍𝒅 , and do the same by hitting 30 and 65 blows to 2 other samples.
5) Turn up to down the sample to have the bottom surface penetrated under the machine
6) Lastly, we take note of all the data by reading the watch linking to the machine.
1 2 3
Sample
(10 blows) (30 blows) (65 blows)
OMC (%) 12 12 12
𝒎𝒎𝒐𝒍𝒅 (𝒈) 6335 6337 6307
𝒎𝒔𝒂𝒎𝒑𝒍𝒆+𝒎𝒐𝒍𝒅 (𝒈) 9975 10447 10678
𝒎𝒔𝒂𝒎𝒑𝒍𝒆 (𝒈) 3640 4110 4371
𝑽𝒎𝒐𝒍𝒅 (𝒄𝒎𝟑 ) 3205.67 3215.65 3156.37
𝝆𝒅 (𝒈/𝒄𝒎𝟑 ) 1.14 1.28 1.38
𝒎𝒄𝒆𝒎𝒆𝒏𝒕 (𝒈) 240 240 240
𝒎𝒕𝒂𝒓𝒆 (𝒈) 8.63 9.49 9.45
𝒎𝒕𝒂𝒓𝒆+𝒃 (𝒈) 108.63 109.49 109.45
𝒎𝒅+𝒕𝒂𝒓𝒆 (𝒈) 96.04 97 97.36
𝒎𝒘𝒂𝒕𝒆𝒓 (𝒈) 720 720 720
I4-GCI(A)-7 Page: 43
Institute of Technology of Cambodia Road design II (TP)
𝐷2
𝑉𝑚𝑜𝑙𝑑 =𝜋 ×𝐻
4
1 2 3
Mold
(10 blows) (30 blows) (65 blows)
D (mm) 151.6 152.05 150.05
H (mm) 177.6 178.5 178.5
Volume (mm3) 3205.67 3215.65 3156.37
Force (kN)
Penetration
10 blows 30 blows 65 blows
0.0 0 0 0
0.5 0.9 1.1 0.9
1.0 1.2 2.0 1.5
1.5 1.5 2.8 2.3
2.0 1.7 3.5 3.3
2.5 1.9 4.2 4.5
3.0 2.0 4.8 5.6
3.5 2.1 5.3 6.7
4.0 2.4 5.9 7.8
4.5 2.5 6.4 9.0
5.0 2.6 6.8 9.9
5.5 2.7 7.3 10.7
6.0 2.9 7.7 11.4
6.5 2.9 8.4 12.2
7.0 3.1 8.5 12.8
7.5 3.1 8.9 13.5
8.0 3.2 9.3 14.3
8.5 3.3 9.7 14.8
9.0 3.4 10.1 15.2
9.5 3.7 10.4 16.3
10.0 3.7 11.0 16.5
I4-GCI(A)-7 Page: 44