General Assembly :- B25 / X25 Hygienic Models, all dimensions +/- 2mm
8.6 Bar (125 psi) 3/8” BSP (F) Determined by Elastomers 21.5 Kg
Operating Temperatures
EPDM - Shows very good water and chemical resistance. Has poor resistance to oils and solvents, but is fair on 212oF -11oF 50o to 212oF
ketones and alcohols. 100oC -24oC 10o to 100oC
Virgin PTFE - Chemically inert, virtually impervious. Very few chemicals are known to react chemically with 356oF 32oF 50o to 212oF
PTFE : molten alkali metals, turbulent liquid or gaseous fluorine and a few fluoro-chemicals such as chlorine 180oC 0oC 10o to 100oC
trifluoride or oxygen difluoride which readily liberate free fluorine at elevated temperatures.
Gentle pumping action to avoid damage to food and Pressures to 8.6 bar.
beverage products.
MODEL
B25 : STANDARD
X25 : ATEX CAT. 2 LUBE FREE (STANDARD)
S : STAINLESS STEEL
WETTED COMPONENTS
Z : 316L STAINLESS STEEL
(POLISHED)
VALVE BALLS
NON - WETTED COMPONENTS
E : FOOD GRADE EPDM
F : NICKEL PLATED ALUMINIUM T : PTFE
S: 316L STAINLESS STEEL S : 316 STAINLESS STEEL
VALVE TYPE
DIAPHRAGMS
B : BALL
E : EPDM (FOOD GRADE)
O : ONE PIECE PTFE
SUCTION ORIENTATION
B : BOTTOM
IMPORTANT
This pump should be used in accordance with the requirements of the Safety, Health & Welfare at Work Act 2005.
IMPORTANT
Read these safety warnings and instructions in this manual completely, before installation and start-up of the pump. It
is the responsibility of the purchaser to retain this manual for reference. This manual must be kept with, and supplied
with the pump at all times. Failure to comply with the recommendations stated in this manual will damage the pump,
and void factory warranty. These instructions are available if required, in the language or languages of the country or
countries in which the equipment is used. Please refer to the manufacturer for details.
IMPORTANT!
This pump is pressurized internally with air pressure during operation. Always make certain that all bolting is in good condition and that
all of the correct bolting is reinstalled during assembly. End-user must ensure correct fitting of Inlet / Outlet connections. Crossed
threads or over tightening of connections will result in leaks. Quick action/release connections are not recommended. If their use is
unavoidable, the levers must be locked to avoid them being forced apart in a hazardous manner.
WARNING!
Before maintenance or repair, shut off the compressed air line, bleed the pressure, and disconnect the air line from the pump. The dis-
charge line may be pressurized and must be bled of its pressure. End-user must ensure correct regulation of air supply pressure, as any
increase in air pressure results in a similar increase in product pressure if stalled-out.
WARNING!
Before doing any maintenance on the pump, be certain all pressure is completely vented from the pump, suction, discharge, piping, and
all other openings and connections. Be certain the air supply is locked out or made non-operational, so that it cannot be started while
work is being done on the pump. Be certain that approved eye protection and protective clothing are worn at all times in the vicinity of
the pump. Failure to follow these recommendations may result in serious injury or death.
WARNING!
Airborne particles and loud noise hazards. Wear ear and eye protection.
WARNING!
Take action to prevent static sparking. Fire or explosion can result, especially when handling flammable liquids. The pump, piping,
valves, containers or other miscellaneous equipment must be grounded. Refer to exhaust safety instructions on page 9.
WARNING!
When used for toxic or aggressive fluids, the pump should always be flushed clean prior to disassembly. User must ensure chemical
compatibility, and any pressure / temperature limits are not exceeded. These instructions include all the information for relevant
diaphragm temperature limits. Pump temperature range can also be found on data-plate attached to the pump.
If pump is not used for more than 5 days, care must be taken when restarting. If in any doubt, remove pump from line and flush with a
suitable cleaner. Solidified deposits within the pump may cause damage to the diaphragms.
CAUTION!
Before pump operation, inspect all gasketed fasteners for looseness caused by gasket creep. Re-torque loose fasteners to prevent
leakage. Follow recommended torques stated in this manual. In cases of excess vibration, Blagdon recommend fitting a Pulsation
Dampener to remove effects of pulse actions from pump operation. Flexible connections can be used, but must be kept to a minimum
length necessary to avoid sharp flexing or straining movements.
Pump will not start Air valve assembly malfunction/Seizure Check carrier for freedom of movement. -
Clean, oil & replace.
Obstructed fluid line. Clean line or increase line size.
Obstructed diaphragm chamber. Remove obstruction.
Diaphragm failure causing fluid & excessive air to be Replace diaphragm.
expelled through the exhaust.
Diaphragm seal failure. Replace shaft seals.
Air valve system malfunction. Check all seals in valve chest assembly.
Air connected to exhaust. Re-connect to air inlet.
Pump strokes but will not Excessive suction lift. Shorten suction line.
discharge Suction line leakage. Check and correct.
Valve ball not seating correctly or damaged. Check and remove obstruction / replace.
Suction line or strainer clogged. Clear.
Diaphragm failure. Replace diaphragm.
Intermittent stroke rate Over lubrication Shut-down pump. Remove air connection
into pump & introduce a small quantity of de-
greasing agent into air valve and replace
line. Run pump until clear.
Diaphragm shaft seal failure. Replace seals.
Air valve system malfunction. Check all seals in valve chest assembly.
Valve ball not seating / partially obstructed. Clear obstruction.
WARNING!
The Atex approved units are supplied with a natural earth ground
cable. This cable is 2 meters in length and permanently connected
through a nut and bolt at the inner cover casting. The other end is free
to connect to the nearest available suitable point to provide a natural
earth ground. This must be done to reduce the risk of electro-static
sparking.
WARNING!
In the event of diaphragm rupture, pumped material may enter the air end of the pump, and be discharged into the atmosphere. If pumping
a product which is hazardous or toxic, the air exhaust must be piped to an appropriate area for safe disposition.
Submerged Installation
Exhaust Safety :-
When a diaphragm fails during operation, pumped liquid can enter and contaminate the air side of the pump. If diaphragm failure is not
severe, i.e. a small split or hole, then the pump can continue to run, with air being forced into the product being pumped. If however the
failure is more serious, then the pump may stop, with fluid or fumes being expelled through the exhaust. Under these conditions it is
recommended that the exhaust is piped away to a safe area. In standard suction lift conditions this can simply be done by piping from the
exhaust connection to a safe area. Multiple installations can be piped to a common connection, then to a safe area. In flooded suction
conditions the exhaust must be taken to a point higher than the fluid level to prevent any siphoning away. In submerged conditions ensure
exhaust is piped away above fluid level.
In all conditions ensure exhaust outlet is not expelling across a non-conductive surface. The exhaust must not be placed less than 100mm
from any non-conductive surface, as this may generate a propagating brush discharge resulting in a possible ignition source.
10 1A259 BACKPLATE 2
ELASTOMER TABLE
11 1A009 BUMP STOP 2 REF DESCRIPTION FOOD GRADE PTFE STAINLESS QTY
No. EPDM STEEL
12 25-059 INNER COVER 2
4 VALVE SEAT - - 25-097 4
13 G242 O-RING 2
5 VALVE BALL 25-062 1A002 1A197 4
14 40-196 VALVE CHEST 1
8 DIAPHRAGM 25-063 25-241 - 2
15 25-060 DIAPHRAGM SHAFT 1
16 G367 O-RING 2
- These items are available in a recommended spares kit. Please refer to your local stockist / distributor for details.
17 G245 O-RING 2
- These items are available in a recommended spares kit - ASK2505-LF - Standard Air side Kit
18 G189 O-RING 2
19 40-194 DIAPHRAGM SHAFT BUSH 2 - These items are available as Sub-Assy. Spare :- SA10585
20 25-072 SHAFT SEAL (See table for Lube Free Seal Option) 6
21 D310 SOCKET CAP SCREW 4 CONNECTION OPTIONAL MANIFOLD PART NUMBERS QTY
TYPE 1” See distributors for details
22 C173 SPRING WASHER 4
SUCTION MANIFOLD DISCHARGE MANIFOLD
23 A040 BOLT 12
DIN 25-112 25-113 1
24 C044 WASHER 32
FERRULE 25-115 25-116 1
25 B469 NUT 16
IDF 25-067 25-068 1
26 A035 BOLT 4
27 G339 O-RING 8
30 40-204 GASKET 1
Page 10
36 40-192 VALVE CARRIER 1
HG-CF-1199 Rev. C - 03.03.14
Sectional General Assembly :- B25 Hygienic Pump.
Page 11