PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9499
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1221 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 405.88
3 Btm mounting frame to top height 627±3 627.78
4 Btm to inletpipe c.d 535±2 535.22
5 Btm to O/P c.d 108±2 108.42
6 Shroud Width 155±2 155.36
7 SF Hole Ø3.5±0.1 3.52
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 1
PDI_2_2_2

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9500
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1222 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 405.34
3 Btm mounting frame to top height 627±3 627.26
4 Btm to inletpipe c.d 535±2 535.40
5 Btm to O/P c.d 108±2 108.48
6 Shroud Width 155±2 156.26
7 SF Hole Ø3.5±0.1 3.54
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 2
PDI_2_2_2_2

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9501
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1223 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 405.82
3 Btm mounting frame to top height 627±3 627.42
4 Btm to inletpipe c.d 535±2 535.66
5 Btm to O/P c.d 108±2 108.72
6 Shroud Width 155±2 156.62
7 SF Hole Ø3.5±0.1 3.52
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 3
PDI_2_2_3

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9502
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1224 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 405.92
3 Btm mounting frame to top height 627±3 627.42
4 Btm to inletpipe c.d 535±2 535.54
5 Btm to O/P c.d 108±2 108.22
6 Shroud Width 155±2 156.52
7 SF Hole Ø3.5±0.1 3.54
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Rahul Kharwa
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 4
PDI_2_2_2_2_2 (2)

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9503
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1225 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 405.70
3 Btm mounting frame to top height 627±3 628.62
4 Btm to inletpipe c.d 535±2 535.76
5 Btm to O/P c.d 108±2 108.42
6 Shroud Width 155±2 156.22
7 SF Hole Ø3.5±0.1 3.54
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 5
PDI_2_2_2_3

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9504
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1226 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 405.18
3 Btm mounting frame to top height 627±3 627.52
4 Btm to inletpipe c.d 535±2 535.36
5 Btm to O/P c.d 108±2 108.18
6 Shroud Width 155±2 156.62
7 SF Hole Ø3.5±0.1 3.52
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 6
PDI_2_2_2_2_2

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9505
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1227 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 406.74
3 Btm mounting frame to top height 627±3 628.42
4 Btm to inletpipe c.d 535±2 535.42
5 Btm to O/P c.d 108±2 108.18
6 Shroud Width 155±2 156.28
7 SF Hole Ø3.5±0.1 3.52
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 7
PDI_2_2_4

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9506
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1228 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 405.84
3 Btm mounting frame to top height 627±3 628.64
4 Btm to inletpipe c.d 535±2 535.24
5 Btm to O/P c.d 108±2 108.16
6 Shroud Width 155±2 156.32
7 SF Hole Ø3.5±0.1 2.56
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 8
PDI_2_2_2_4

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9507
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1229 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 405.22
3 Btm mounting frame to top height 627±3 628.24
4 Btm to inletpipe c.d 535±2 535.36
5 Btm to O/P c.d 108±2 108.52
6 Shroud Width 155±2 156.74
7 SF Hole Ø3.5±0.1 3.54
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 9
PDI_2_2_2_2_3

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9508
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1230 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 405.32
3 Btm mounting frame to top height 627±3 628.42
4 Btm to inletpipe c.d 535±2 535.58
5 Btm to O/P c.d 108±2 108.60
6 Shroud Width 155±2 156.74
7 SF Hole Ø3.5±0.1 3.52
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 10
PDI_2_2_3_2

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9509
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1231 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 405.18
3 Btm mounting frame to top height 627±3 628.68
4 Btm to inletpipe c.d 535±2 535.42
5 Btm to O/P c.d 108±2 408.22
6 Shroud Width 155±2 156.28
7 SF Hole Ø3.5±0.1 3.54
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 11
PDI_2_2_2_3_2

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9510
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1232 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 406.52
3 Btm mounting frame to top height 627±3 628.68
4 Btm to inletpipe c.d 535±2 535.14
5 Btm to O/P c.d 108±2 108.34
6 Shroud Width 155±2 156.14
7 SF Hole Ø3.5±0.1 3.54
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 12
PDI_2_2_2_2_2_2

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9511
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1233 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 406.52
3 Btm mounting frame to top height 627±3 628.42
4 Btm to inletpipe c.d 535±2 535.34
5 Btm to O/P c.d 108±2 108.56
6 Shroud Width 155±2 156.24
7 SF Hole Ø3.5±0.1 3.58
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 13
PDI_2_2_2_2_2_2_2

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9512
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1234 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 406.22
3 Btm mounting frame to top height 627±3 628.36
4 Btm to inletpipe c.d 535±2 535.38
5 Btm to O/P c.d 108±2 108.52
6 Shroud Width 155±2 156.56
7 SF Hole Ø3.5±0.1 3.52
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 14
PDI_2_2_2_2_2_2_2_2

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9513
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1235 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 406.62
3 Btm mounting frame to top height 627±3 628.26
4 Btm to inletpipe c.d 535±2 535.34
5 Btm to O/P c.d 108±2 108.34
6 Shroud Width 155±2 156.74
7 SF Hole Ø3.5±0.1 3.52
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 15
PDI_2_2_2_2_2_2_2_2_2

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9514
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1236 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 406.56
3 Btm mounting frame to top height 627±3 628.24
4 Btm to inletpipe c.d 535±2 535.38
5 Btm to O/P c.d 108±2 108.16
6 Shroud Width 155±2 156.88
7 SF Hole Ø3.5±0.1 3.54
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 16
PDI_2_2_2_2_2_2_2_2_2_2

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9515
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1237 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 406.68
3 Btm mounting frame to top height 627±3 628.62
4 Btm to inletpipe c.d 535±2 535.76
5 Btm to O/P c.d 108±2 108.16
6 Shroud Width 155±2 156.60
7 SF Hole Ø3.5±0.1 3.54
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 17
PDI_2_2_2_2_2_2_2_2_2_2_2

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9516
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1238 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 406.48
3 Btm mounting frame to top height 627±3 628.14
4 Btm to inletpipe c.d 535±2 535.34
5 Btm to O/P c.d 108±2 108.72
6 Shroud Width 155±2 156.54
7 SF Hole Ø3.5±0.1 3.56
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 18
PDI_2_2_2_2_2_2_2_2_2_2_2_2

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9517
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1239 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 406.96
3 Btm mounting frame to top height 627±3 628.52
4 Btm to inletpipe c.d 535±2 535.58
5 Btm to O/P c.d 108±2 108.70
6 Shroud Width 155±2 156.26
7 SF Hole Ø3.5±0.1 3.52
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 19
PDI_2_2_2_2_2_2_2_2_2_2_2_2_2

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9518
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 12
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1240 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 406.16
3 Btm mounting frame to top height 627±3 628.46
4 Btm to inletpipe c.d 535±2 535.74
5 Btm to O/P c.d 108±2 108.82
6 Shroud Width 155±2 156.88
7 SF Hole Ø3.5±0.1 3.58
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 20
PDI_2_2_2_2_2_2_2_2_2_2_2_2_2_2

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9534
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1241 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 406.48
3 Btm mounting frame to top height 627±3 628.36
4 Btm to inletpipe c.d 535±2 535.68
5 Btm to O/P c.d 108±2 108.62
6 Shroud Width 155±2 156.84
7 SF Hole Ø3.5±0.1 3.56
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 21
Recovered_Sheet1

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9535
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1242 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 406.84
3 Btm mounting frame to top height 627±3 628.82
4 Btm to inletpipe c.d 535±2 535.16
5 Btm to O/P c.d 108±2 108.68
6 Shroud Width 155±2 156.34
7 SF Hole Ø3.5±0.1 3.54
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 22
Recovered_Sheet2

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9536
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1243 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 406.94
3 Btm mounting frame to top height 627±3 628.64
4 Btm to inletpipe c.d 535±2 535.60
5 Btm to O/P c.d 108±2 108.46
6 Shroud Width 155±2 156.74
7 SF Hole Ø3.5±0.1 3.58
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 23
Recovered_Sheet3

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9537
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1244 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 406.22
3 Btm mounting frame to top height 627±3 628.68
4 Btm to inletpipe c.d 535±2 535.74
5 Btm to O/P c.d 108±2 108.34
6 Shroud Width 155±2 156.16
7 SF Hole Ø3.5±0.1 3.52
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 24
Recovered_Sheet4

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9538
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1245 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 406.86
3 Btm mounting frame to top height 627±3 628.24
4 Btm to inletpipe c.d 535±2 535.64
5 Btm to O/P c.d 108±2 108.22
6 Shroud Width 155±2 156.90
7 SF Hole Ø3.5±0.1 3.52
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 25
Recovered_Sheet5

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9539
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1246 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 406.52
3 Btm mounting frame to top height 627±3 628.34
4 Btm to inletpipe c.d 535±2 535.18
5 Btm to O/P c.d 108±2 108.90
6 Shroud Width 155±2 156.68
7 SF Hole Ø3.5±0.1 3.56
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 26
Recovered_Sheet6

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9540
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1247 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 406.16
3 Btm mounting frame to top height 627±3 628.34
4 Btm to inletpipe c.d 535±2 535.58
5 Btm to O/P c.d 108±2 108.16
6 Shroud Width 155±2 156.64
7 SF Hole Ø3.5±0.1 3.54
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 27
Recovered_Sheet7

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9541
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1248 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 406.84
3 Btm mounting frame to top height 627±3 628.66
4 Btm to inletpipe c.d 535±2 535.54
5 Btm to O/P c.d 108±2 108.42
6 Shroud Width 155±2 156.34
7 SF Hole Ø3.5±0.1 3.58
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 28
PDI_00

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9542
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1249 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 406.18
3 Btm mounting frame to top height 627±3 628.32
4 Btm to inletpipe c.d 535±2 535.54
5 Btm to O/P c.d 108±2 108.66
6 Shroud Width 155±2 156.16
7 SF Hole Ø3.5±0.1 3.52
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 29
PDI_00_2

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9543
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1250 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 406.20
3 Btm mounting frame to top height 627±3 628.66
4 Btm to inletpipe c.d 535±2 535.54
5 Btm to O/P c.d 108±2 108.28
6 Shroud Width 155±2 156.34
7 SF Hole Ø3.5±0.1 3.54
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 30
PDI_00_2_2

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9544
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1251 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 406.96
3 Btm mounting frame to top height 627±3 628.66
4 Btm to inletpipe c.d 535±2 535.14
5 Btm to O/P c.d 108±2 108.28
6 Shroud Width 155±2 156.62
7 SF Hole Ø3.5±0.1 3.56
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 31
PDI_00_2_2_2

PDI & WTC REPORT


F/BPIL/QA-RA/65
CUSTOMER NAME: TAFE, SUPPLIER :- BANCO PRODUCTS (I) LTD.
PART Radiator Assembly – TAFE MF 241 REPORT NO. CHALLAN NO. 9545
PT. NO. 1421P00403 PDI /09/2023 DATE : Rad Sr.No: QTY : 16
DRG./MOD.NO. : B1 715 000 000 – 1 , Mod- T1 15.09.2023 I23-1252 Nos
SR.NO. SPECIFICATION FOR MANUFACTURER'S OBSERVATION OBSERVATION
1 2 3 4 5
1 Core Type AB – 360 – 635
2 Core Height 405±3 406.44
3 Btm mounting frame to top height 627±3 628.74
4 Btm to inletpipe c.d 535±2 535.68
5 Btm to O/P c.d 108±2 108.36
6 Shroud Width 155±2 156.62
7 SF Hole Ø3.5±0.1 3.58
8 Btm to shroud c.d 251±2.5 Shroud Gauge Answering
9 Mounting slot c.d 295±2 CD Checking gauge Answering
10 Shroud I.D dia 407+5/-0 Shroud Gauge Answering
11 Over Flow hose connecting Hole No any Blockage O.K
12 Visual inspection free from damage O.K
13 Side frame powder coating 60 micron O.K

WORK TEST CERTIFICATE

RESULTS SPECIFIED ACTUAL


LEAKAGE TESTING :
1 2
PNEUMATIC PRESSURE APPLIED 1.5 Kg/Cm Found Ok
TEST TIME 60 Sec. 60 Sec
RADIATOR PRESSURE CAP. :
2 2
PRESSURE VALUE OPENING 0.9 ± 0.15 Kg/Cm 0.80 - 0.90
2
VACUUM VALUE OPENING < 0.05 Kg/Cm Found OK.
SUPP. REMARKS : GIN NO. : DATE :
REMARKS ACCEPTED / REJECTED/COND. ACCEPTED
Gourav/ Prince
DATE :
INSPECTOR INCHARGE DATE INSPECTOR INCHARGE / HOD
15.09.2023

Page 32