37+182-5

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

DETAILS OF CH.

-37+182

15968 15968

15968

15968
100
100

900

900
800
920
1200
450
625

4800

5000

13000

13000

12300
9850

3500

3500
500
800
1200
450

1220
1800 1800

900

900
100

100
5500 2800 5200 8000 1500 10000
13500 19500

10000 10000

(SCALE:- N.T.S)

15968

15968
SAFE BEARING CAPACITRY OF SOIL IN T/M2
DEPTH OF DEPTH OF
FOUNDATION 1.5 m 3.00 m 4.5 m 6.0 m FOUNDATION 1.5 m 3.00 m 4.5 m 6.0 m 15968 15968

37+182 BH-A1 20.1 26.7 61.8 77.5 37+182 BH-P2 25.2 43.1 57.8 70.7
37+182 BH-P1 21.8 27.9 58.8 72.0 38+182 BH-A2 18.4 25.4 35.5 46.2

SITE PLAN
NALA
PROP. BRIDGE
PROP. RAILWAY
TRACK CENTRE

NOTES :-

1. ALL DIMENSIONS ARE IN MM. & LEVELS ARE IN METRE UNLESS OTHERWISE SPECIFIED.
2. DO NOT SCALE THE DRAWING,FOLLOW WRITTEN DIMENSIONS ONLY.
3. GRADE OF CONCRETE :-
RETAINING WALLS - M35 (RCC) DESIGN MIXED.
4. LOADING STANDARD 25T AXLE LOAD.
5. SEISMIC ZONE - ZONE III
6. UNTENSIONED STEEL (Fe 500) IN RENFORCEMENT SHALL CONFIRM
ISI786:2008
7. MAXIMUM BASE PRESSURE AT FOUNDING LEVEL FOR
TYPE OF RW REGULAR LOAD CONDITION SEISMIC LOAD CONDITION
RETAINING WALL A IS 40 MT/ SqM, & 72 MT/ SqM,
RETAINING WALL B IS 35 MT/ SqM, & 65 MT/ SqM,
RETAINING WALL C IS 30 MT/ SqM, & 52 MT/ SqM,
RETAINING WALL D IS 25 MT/ SqM, & 40 MT/ SqM,
RETAINING WALL E IS 17 MT/ SqM, & 35 MT/ SqM,

8. CONCRETING OF FOOTING LEVEL SHALL MORE THAN FOUNDING PRESSURE AND


IT SHALL BE ENSURED AT SITE BEFORE EXECUTION OF WORK.
9. MN LAP LENGTH OF 50 DIA SHALL BE PROVIDED AT ALL JOINTS OR AS PER
DESIGN TO BE DONE CLAUSE NO.15.9.6 OF IRS CONCRETE BRIDGE CODE.
10. MN BOND LENGTH FOR REINFORCING BARS SHALL BE AS PER CLAUSE NO.
1.FOR WING\RETURN WALL. 15.9.6 OF IRS CONCRETE BRIDGE CODE .
11. LAPPING OF BARS SHOULD BE MINIMIZED & ALL STAGGERED WHEREVER
NECESSARY.
12. NOT MORE THAN 50% BARS SHALL BE LAPPED AT ONE SECTION.
13. DO NOT COUNT THE NO. OF BARS SHOWN IN DRG. FOLLOW WRITTEN DETAILS ONLY
FOR SPACING & NO. OF BARS.
14. TOLERANCE SHALL FOLLOWED AS PER IRS CONCRETE BRIDGE CODE.
15. ALL WORK SHALL BE DONE AS PER RELEVENT IRS & IS CODES .
16. CLEAR COVER TO REINFORCEMENT IS 50MM ABOVE GL & 75MM BELLOW GL.
WORK:- CONSTRUCTION OF PROPOSED RUB (SIZE- 2X18.3+1X30.5 M, 17.
18.
CONCRETE SHALL BE MECHANICALLY MIXED & VIBRATED.
BACK FILL MATERIAL SHALL CONFORM TO CL. 7.5 OF IRS SUBSTRUCTURE & FOUNDATION CODE,
COMPOSITE GIRDER) WITH LATEST CORRIGENDUM & ADDENDUM SLIPS.
19. 600 TH. FILTER MEDIA SHALL BE PROVIDED WITH HAND PACKED BOULDERS ON THE EARTH FACE OF
AT CH.-37+182 IN CONNECTION WITH BUDNI - INDORE RETAINING WALLS. VOIDS BETWEEN BOULDERS SHALL BE FILLED WITH SMALLER SIZED STONES TO
NEW BG RAIL LINE PROJECT 20.
PREVENT OUT FLOW OF BACK FILLED MATERIALS.
100DIA WEEP HOLES TO BE PROVIDED ON ALL EARTH RETAINING MEMBERS @ 1000MM C/C BOTH

TITLE:- WORKING DRAWING 21.


HORIZONTALLY , WHEREVER APPLICABLE.
FESIBILITY OF DRG SHALL BE CHECKED BY FIELD UNIT BEFORE EXECUTION OF WORK WITH RESPECT
TO APPROVED GAD OR SITE CONDITION .
22. L- SHAPED ANCHORAGE BARS OF 32DIA @ 1000MM C/C BOTH WAYS SHALL BE PROVIDED IN BASE SLAB
DRAWING NO. :- RVNL/BNI-INDB/GAD/CH. 37+182 SCALE :- NOT TO SCALE WITH MINIMUM ANCHORAGE OF 700MM IN PARENT ROCK.