NEC Dhaka Lab test report: Updated 05th March 2014

TEST RESULT OF PASOLINK EQUIPMENTS

CUSTOMER NAME : GP
UNIT CODE/UNIT NAME : MDP-400MB-1B/ iPasolink 200
SERIAL NUMBER : 8971
DATE OF MANUFACTURE : Oct-2010
DATE OF RECEIPT : 27-02-2014

TEST RESULT/STATUS

Remarks
1. Physical Check Result: Confirmed : Attachment

Remarks
2. Electrical Test Result: Faulty : Attachments

3. Comments

We have received this IDU as faulty. However, we have tested the IDU & based on above two tests
result, the MODEM-1 is faulty, but MODEM-2 is good. This IDU is creating HIGH BER for the
FAR End and AIS received in the BER tester.

email: s-bhattacharjee@nec-bangladesh.com Cell: +8801713435933

Test Performed By : Md. Feroz Shah Date: 09-03-2014

Approved By : Sushil Bhattacharjee Date: 09-03-2014


NEC Dhaka Lab test report: Updated 05th March 2014
NEC Corporation, Dhaka Branch office. Doreen Tower (Level-06), 6A North Avenue Commercial Area,Gulshan-2, Dhaka-
1212. Phone: +880-2-8832903-4, Fax: +880-2-883290

Equipment Name: IDU


Serial No: 8971
Physical damaged check report Checked by: Feroz Shah
Date: 09-03-2014
Check
No. Description result Remarks
Yes No
1 Rust of outside frame
Take a photo for frame rust and attached to
the fault report for Japan
1) over all frame(IDU/ODU) √ Photo:
2) connector (including pin, connector cover,

and connector bolts) Photo:
3) Any screws √ Photo:
4) other (

) Photo:
2 Mechanical damage on outside frame
Take a photo for mechanical damage and

attached to the fault report for Japan
1) outside frame √ Photo:
2) all connectors ( BNC, D-sub etc) √ Photo:
3) on/off switches √ Photo:
3) any LEDs √ Photo:
4) other (

) Photo:
3 Open the IDU shelf and check the following
items. Take a photo in case of rust and attach
the fault report for Japan
1) internal circuit board rust Photo: attachment
(check-point: )

2) any screws rust √ Photo:
3) other rust (

) Photo:
4
removed the serial number for IDU/ODU √
NEC Dhaka Lab test report: Updated 05th March 2014

Fig: No Physical Damage

Fig: No Physical Damage in Main board


NEC Dhaka Lab test report: Updated 05th March 2014
Equipment Name: IDU
Electrical test sheet
Serial No: 8971
Checked by: Feroz Shah
No. Description Check result Remarks
Date: 09-03-2014
Yes No
1. Lab IDU testing:
1.1 Check point for Power supply fault
1) Check power supply fuse is good or not √
2) Check the LED of power supply is good √
3) Any loose connection of DC power connectors or not √
4) check the output voltage of the DC power supply (as nominal √
value), is it OK
1.2 Modem and control fault (MODEM1 & MODEM-2) Modem-1 faulty;
MODEM-2 Good
1) Check all LEDs are working in front of IDU unit √
2) Make a HOP with respective IDU & ODU. Can make HOP or not √ Fig-attachment
3) Check is there any alarm as like DEM/MOD/MDP-CPU/PMC-ALM √ Fig-attachment
CONT LINK etc. or not
4) Check E1 loop using PDH tester (for 5mins) if E1 ports problem √ Using E1
mentioned in R-R form, found E1 port faulty or not Terminator
5) Check STM-1 loop test using SDH tester if STM-1 problem NA
mentioned in R-R form, found STM-1 port faulty or not (Note-1)
6) Check license key if any problem regarding license key is √
mentioned in R-R form. License key problem or not
7) Check Firm ware version of the CTRL and confirmed whether √ Fig-attachment
latest or not
2 Lab ODU testing: NA
1) check ODU can communicate with IDU or not ( LCT/Pnmtj NA
screen captured picture will be required)
2) Check alarms in ODU like Tx power/Rx level/Tx APC/Rx APC/IF NA
input. Is there any alarm or not
3) Check ODU Tx-power using power meter (verify whether any NA
problem in Tx maximum and minimum output power or not)(Note-
1)
4) Check ODU Tx-power using LCT (verify whether any problem in NA
Tx maximum and minimum output power or not)
5) Check Rx level for different attenuation (using programmable NA
attenuator) values as well as different frequencies whether any
problem like Rx Level higher/lower than nominal values. (Note-1)
6) Check Rx level by LCT/PNMT as well as voltmeter. Problem in NA
RSL or not
7) Check RF filter is working properly for assigned Pass Band or NA
not, using Spectrum analyzer. This check is done if any
complaints like ODU creating interference to other system (Note-1)
Note-1: Depends on availability of relevant test equipment. Revision #:003

Test Summary:
We received this IDU as faulty. However, we have tested as mentioned above and found Modem-1 showing RDI
Warning even though the RSL is good and MODEM-1 Tx/Rx is creating HIGH BER at Far End IDU and Modem-2 is
working properly.
Faulty IDU ----------------- Far-end IDU
RDI HIGH BER
EARLY WARNING
RF UAE
E1 AIS
NEC Dhaka Lab test report: Updated 05th March 2014
Testing IDU: MODEM-1; Alarm found: RDI

MODEM-2; No alarm

Found RDI
alarm and AIS
for MODEM-1

Fig-1: RDI and AIS found for MODEM-1

Fig-2: Radio Configuration for MODEM-1


NEC Dhaka Lab test report: Updated 05th March 2014

Even though RDI


alarm, MODEM-1
is Locked.

Fig-3: Testing IDU Clock status

Fig-4: PMON/RMON report for MODEM-1


NEC Dhaka Lab test report: Updated 05th March 2014

No BER found for


MODEM-1 and
RSL is good.

Fig-5: RSL for MODEM-1

Fig-6: Inventory of testing IDU


NEC Dhaka Lab test report: Updated 05th March 2014

Found High
BER, E1 AIS,
UAE and Early
Warning at Far
End IDU.

Fig-7: Far End IDU RSL when using MODEM-1

Even though
we found
high BER but
MODEM is
Locked.

Fig-8: Far End IDU Clock status when using MODEM-1


NEC Dhaka Lab test report: Updated 05th March 2014

Fig-9: PMON/RMON report for Far End IDU

Found HIGH
BER at FAR End

Fig-10: RSL of Far End IDU


NEC Dhaka Lab test report: Updated 05th March 2014

Fig-11: Radio Configuration of Far End IDU

MODEM-2 is
showing good
RSL.

Fig-12: Testing IDU RSL using Modem-2


NEC Dhaka Lab test report: Updated 05th March 2014

No alarm
found for
MODEM-
2

Fig-13: Far End IDU Current status when using MODEM-2