CUSTOMER NAME : GP
UNIT CODE/UNIT NAME : MDP-400MB-1B/ iPasolink 200
SERIAL NUMBER : 8927
DATE OF MANUFACTURE : Oct-2010
DATE OF RECEIPT : 27-02-2014
TEST RESULT/STATUS
Remarks
1. Physical Check Result: Confirmed : Attachment
Remarks
2. Electrical Test Result: Faulty : Attachments
3. Comments
We have received this IDU as faulty. However, we have tested the IDU & based on above two tests
result, the MODEM-1 is faulty, but MODEM-2 is good. This IDU is creating HIGH BER for the
FAR End and AIS received in the BER tester.
Test Summary:
We received this IDU as faulty. However, we have tested as mentioned above and found Modem-1 showing RDI
Warning even though the RSL is good and MODEM-1 Tx/Rx is creating HIGH BER at Far End IDU and Modem-2 is
working properly.
Faulty IDU ----------------- Far-end IDU
RDI HIGH BER
E1 AIS LOF
LTI
E1 AIS
Found RDI
alarm and AIS
for MODEM-1
Found LOF,
LTI, and
TDM/AMR
Range
Mismatch at
Far End IDU
when using
MODEM-1.
We found
clock is
Holdover
for
MODEM-
1.
Found
HIGH BER
at FAR End
MODEM-2
is showing
good RSL.
No alarm
found for
MODEM-
2