NEC Dhaka Lab test report: Updated 20th FEB 2014

TEST RESULT OF PASOLINK EQUIPMENTS

CUSTOMER NAME : GP
UNIT CODE/UNIT NAME : MDP-400MB-1B/ iPasolink 200
SERIAL NUMBER : 8927
DATE OF MANUFACTURE : Oct-2010
DATE OF RECEIPT : 27-02-2014

TEST RESULT/STATUS

Remarks
1. Physical Check Result: Confirmed : Attachment

Remarks
2. Electrical Test Result: Good : Attachments

3. Comments

We have received this IDU as faulty. However, we have tested the IDU & based on above two tests
result, Modem-1 and Modem-2 is good.

email: s-bhattacharjee@nec-bangladesh.com Cell: +8801713435933

Test Performed By : MD. Feroz Shah Date: 09-03-2014

Approved By : Sushil Bhattacharjee Date: 09-03-2014

NEC Corporation, Dhaka Branch Office, Doreen Tower (L-6), 6A North Avenue C/A , Gulshan-2, Dhaka-1212,Bangladesh. Telephone:
+880 28832903/8832904; Fax: +880 2 8832905
NEC Dhaka Lab test report: Updated 20th FEB 2014

Physical damaged check report Equipment Name: IDU


Serial No: 8927
Check
Checked by: Feroz Shah
No. Description result
Date: 09-03-2014 Remarks
Yes No
1 Rust of outside frame
Take a photo for frame rust and attached to
the fault report for Japan
1) over all frame(IDU/ODU) √ Photo:
2) connector (including pin, connector cover,

and connector bolts) Photo:
3) Any screws √ Photo:
4) other (

) Photo:
2 Mechanical damage on outside frame
Take a photo for mechanical damage and

attached to the fault report for Japan
1) outside frame √ Photo:
2) all connectors ( BNC, D-sub etc) √ Photo:
3) on/off switches √ Photo:
3) any LEDs √ Photo:
4) other (

) Photo:
3 Open the IDU shelf and check the following
items. Take a photo in case of rust and attach
the fault report for Japan
1) internal circuit board rust √ Photo: attachment
(check-point: )

2) any screws rust √ Photo:


3) other rust (

) Photo:
4
removed the serial number for IDU/ODU √
NEC Dhaka Lab test report: Updated 20th FEB 2014

Fig: No Physical Damage

Fig: No Physical Damage in Main board


NEC Dhaka Lab test report: Updated 20th FEB 2014
Electrical test sheet Equipment Name: IDU
Serial No: 8927
Checked by: Feroz Shah
Date: 09-03-2014
No. Description Check result Remarks
Yes No
1. Lab IDU testing:
1.1 Check point for Power supply fault
1) check power supply fuse is good or not √
2) check the LED of power supply is good √
3) Any loose connection of DC power connectors or not √
4) check the output voltage of the DC power supply (as nominal √
value), is it OK
1.2 Modem and control fault Modem-1 good
1) Check all LEDs are working in front of IDU unit √
2) Make a HOP with respective IDU & ODU. Can make HOP or not √ Fig-attachment
3) Check is there any alarm as like DEM/MOD/MDP-CPU/PMC-ALM √ Fig-attachment
CONT LINK etc. or not
4) Check E1 loop using PDH tester (for 5mins) if E1 ports problem √ Using E1
mentioned in R-R form, found E1 port faulty or not Terminator
5) Check STM-1 loop test using SDH tester if STM-1 problem NA
mentioned in R-R form, found STM-1 port faulty or not (Note-1)
6) Check license key if any problem regarding license key is √
mentioned in R-R form. License key problem or not
7) Check Firm ware version of the CTRL and confirmed whether √ Fig-attachment
latest or not
2 Lab ODU testing: NA
1) check ODU can communicate with IDU or not ( LCT/Pnmtj NA
screen captured picture will be required)
2) Check alarms in ODU like Tx power/Rx level/Tx APC/Rx APC/IF NA
input. Is there any alarm or not
3) Check ODU Tx-power using power meter (verify whether any NA
problem in Tx maximum and minimum output power or not)(Note-
1)
4) Check ODU Tx-power using LCT (verify whether any problem in NA
Tx maximum and minimum output power or not)
5) Check Rx level for different attenuation (using programmable NA
attenuator) values as well as different frequencies whether any
problem like Rx Level higher/lower than nominal values. (Note-1)
6) Check Rx level by LCT/PNMT as well as voltmeter. Problem in NA
RSL or not
7) Check RF filter is working properly for assigned Pass Band or NA
not, using Spectrum analyzer. This check is done if any
complaints like ODU creating interference to other system (Note-1)
Note-1: Depends on availability of relevant test equipment. Revision #:003

Test Summary:
We received this IDU as faulty. However, we have tested as mentioned above and found Modem-1 and Modem-2 is
good.
NEC Dhaka Lab test report: Updated 20th FEB 2014

Fig-1: Inventory

Modem-1 can
communicate with
ODU

Fig-2: Modem-1 Radio Configuration


NEC Dhaka Lab test report: Updated 20th FEB 2014

No alarm

Fig-3: Current Status using Modem-1

MODEM-1 Shows
good RSL

Fig-4: RSL using Modem-1


NEC Dhaka Lab test report: Updated 20th FEB 2014

MODEM-2 shows
good RSL

Fig-4: RSL using Modem-2