Professional Documents
Culture Documents
far2157_installation_manual_e_2-2011
far2157_installation_manual_e_2-2011
FAR-2157/2157-BB/2157-D
Installation manual
1.1 Antenna Unit ........................................ 1-1 4.2 Memory Card Interface Unit ............... 4-10
1.2 Monitor Unit.......................................... 1-7 4.3 DVI-RGB Conversion Kit .................... 4-13
1.3 Control Unit ........................................ 1-10 4.4 BNC Connector Converter ................. 4-16
www.furuno.co.jp
All brand and product names are trademarks, registered trademarks or service marks of their respective holders.
The paper used in this manual
is elemental chlorine free.
9-52 Ashihara-cho,
Nishinomiya, 662-8580, JAPAN
Telephone : +81-(0)798-65-2111
Fax : +81-(0)798-65-4200
WARNING
Radio Frequency Radiation Hazard
The radar antenna emits electromagnetic radio frequency (RF) energy which can
be harmful, particularly to your eyes. Never look directly into the antenna aperture
from a close distance while the radar is in operation or expose yourself to the
transmitting antenna at a close distance.
Distances at which RF radiation levels of 100 W/m2 and 10 W/m2 exist are given in
the table below.
Note: If the antenna unit is installed at a close distance in front of the wheel house,
it may be necessary to halt transmission within a certain sector of antenna
revolution. This can be done from the SCANNER menu.
Distance to Distance to
Radiator
100 W/m2 10 W/m2
type
point point
XN4A 1.20 m 13.60 m
XN5A 1.10 m 12.30 m
i
WARNING CAUTION
Do not open the equipment unless A proper license is necessary to install
totally familiar with electrical circuits a radar.
and service manual.
See your dealer for details.
Only qualified personnel should work
inside the equipment. Observe the following compass safe
distances to prevent interference to a
Wear a hard hat and safety belt when magnetic compass:
mounting the antenna unit.
Standard Steering
Serious injury or death can result if compass compass
someone falls from the radar antenna mast. Antenna Unit
4.30 m 2.80 m
(60 kw)
Construct a suitable service platform Monitor Unit
from which to install the antenna unit. (MU-201CR) 1.55 m 1.00 m
Processor Unit
Serious injury or death can result if (RPU-013) 1.35 m 0.85 m
someone falls from the radar antenna Control Unit
mast. (RCU-014) 0.30 m 0.30 m
Control Unit
Do not install units other than the (RCU-015) 0.95 m 0.60 m
antenna unit in a place subject to rain Control Unit
or water splash. (RCU-016) 0.65 m 0.45 m
Power Supply
0.30 m 0.30 m
Fire, electrical shock or injury can result if Unit (PSU-006)
water leaks into those units. Memory Card
Interface Unit 0.90 m 0.60 m
Turn off the power at the switchboard (CU-200)
before beginning the installation. Switching Hub
1.00 m 0.60 m
(HUB-100)
Fire, electrical shock or injury can result if Monitor Unit
1.65 m 1.05 m
the power is on during the installation. (MU-190)
ii
SYSTEM CONFIGURATION
ANTENNA UNIT
XN4A-RSB-106
XN4A-RSB-107
XN5A-RSB-106
XN5A-RSB-107
RECTIFIER
100/110/115/220/230 VAC
RU-3423
1f, 50/60 Hz
200 VAC, 3f, 50 Hz
220 VAC, 3f, 60 Hz
MONITOR UNIT
MU-201CR
*
(For FAR-2157)
TRANSFORMER
110 VAC, 3f, 60 Hz
RU-5693 MU-190
(For FAR-2157-D)
220 VAC, 3f, 50 Hz TRANSFORMER
RU-6522
CONTROL UNIT
RCU-014
TRANSFORMER (Standard)
440 VAC, 3f, 50 Hz RU-5466-1 OR 100-230 VAC
RCU-015
(For HV power) (Trackball) 1f, 50/60 Hz
100-115V/220-230 VAC
1f, 50/60 Hz
440 VAC, 1f, TRANSFORMER CONTROL UNIT
50/60 Hz RU-1803 RCU-016
PROCESSOR
Navigator IEC-61162 Serial data UNIT Radar Remote
(I/O) RPU-013 Display
Speed Log IEC-61162 Serial data
(Input) SWITCHING HUB
Gyrocompass GYRO CONVERTER HUB-100
GC-10
AD-100 Alarm
AIS VDR
Track Controller
External
MEMORY CARD Monitor
INTERFACE UNIT
CU-200-FAR
TRANSFORMER
RU-1803
100-115 VAC/
: Standard supply 220-230 VAC 440 VAC
: Optional supply
1f, 50/60 Hz 1f, 50/60 Hz
: Local supply
Equipment category
* FAR-2157-BB is not equipped with a Unit Category
monitor unit. Procure one locally.
Antenna Exposed to weather
Other units Protected from weather
iii
EQUIPMENT LISTS
Standard supply
Name Type Code No. Qty Remarks
Antenna Unit XN4A-RSB-106 – 200/220 VAC, 2570 mm
XN4A-RSB-107 – 24 VDC, 2570 mm
1
XN5A-RSB-106 – 200/220 VAC, 3210 mm
XN5A-RSB-107 – 24 VDC, 3210 mm
Power Supply Unit PSU-006 – 1
Monitor Unit MU-201CR – 1 For FAR-2157
MU-190 – For FAR-2157-D
Processor Unit RPU-013 – 1
Control Unit RCU-014 – Standard type
1
RCU-015 – Trackball type
Installation CP03-31301 008-572-970 1 For antenna unit
Materials* CP03-25700 000-080-435 15 m signal cable (RW-9600)
CP03-25710 000-080-436 30 m signal cable (RW-9600)
1
CP03-25730 000-082-191 40 m signal cable (RW-9600)
CP03-25720 000-080-437 50 m signal cable (RW-9600)
CP03-25800 000-080-434 1 Cable assy. for monitor unit
CP03-25602 008-535-940 1 For processor unit
CP03-31401 008-572-750 1 For power supply unit
CP03-25604 008-539-850 1 For control unit
Accessories* FP03-09810 008-536-010 1 For monitor unit
FP03-09850 008-535-610 For standard-type control unit
1
FP03-09860 008-535-690 For trackball-type control unit
Spare Parts* SP03-14404 008-535-910 For processor unit, 100 VAC
1
SP03-14405 008-535-920 For processor unit, 220 VAC
SP03-09203 008-424-380 1 For 24 VDC antenna unit
SP03-14401 008-535-990 1 For FAR-2157's monitor unit
SP03-15501 008-572-730 For power supply unit, 100 VAC
1
SP03-15501 008-572-740 For power supply unit, 220 VAC
Optional equipment
Name Type Code No. Remarks
Gyro Converter GC-10-2 000-080-440 See Chapter 4.
Rectifier Unit RU-3423 – 100/110/115/220/230 VAC to 24 DC,
for power supply unit
(Continued on the next page.)
iv
Name Type Code No. Remarks
Stepdown RU-1803 – 440 to 100 VAC, for processor unit
Transformer RU-5693 – 110 to 220 VAC, 3φ, for antenna unit
Unit
RU-6522 – 220 to 200 VAC, 3φ, for antenna unit
RU-5466-1 – 440 to 200 VAC, 3φ, for antenna unit
Memory Card CU-200-FAR 000-081-568 w/CP03-27430, see Chapter 4.
Interface Unit
External Alarm OP03-21 000-030-097
Buzzer
Control Unit RCU-016 000-080-299 Remote type, w/FP03-09860
RAM Card O0RAM08MC-005 004-376-740 8MB
DVI-RGB OP03-180-1 008-545-590 For installation in the field.
Converter Kit OP03-180-2 008-536-070 For installation in field. See Ch. 4.
Cable Assy. XH10P-W-6P L=20M 000-149-748 Processor unitQControl unit, 20 m
XH10P-W-6P L=30M 000-149-749 Processor unitQControl unit, 30 m
XH10P-W-5P-A L=10M 000-149-050 Between control units, 10 m
XH10P-W-5P-A L=20M 000-149-051 Between control units, 20 m
XH10P-W-5P-A L=30M 000-149-052 Between control units, 30 m
DVI-D/D S-LINK 10M 000-150-200 Processor unitQControl unit, 10 m
S03-9-5(8-8P) 008-206-640 External radar, 5 m, 8-8P
S03-9-10(8-8P) 008-206-650 External radar, 10 m, 8-8P
S03-9-15(8-8P) 008-209-160 External radar, 15 m, 8-8P
Installation CP03-28900 000-082-658 FR-FTPC-CY 10 m, modular
Materials connector MPS588-C, 2 pcs.
(Armored LAN- CP03-28910 000-082-659 FR-FTPC-CY 20 m, modular
Cable Kit) connector MPS588-C, 2 pcs.
CP03-28920 000-082-660 FR-FTPC-CY 30 m, modular
connector MPS588-C, 2 pcs.
Bracket Assy. FP03-09820 008-535-560 Hanger assy. for monitor unit
Handgrip Assy. FP03-09840 008-535-570 For monitor unit
Dust Cover 03-163-1201 100-307-260 For monitor unit
Clamp Assy. OP03-182 008-535-620 For RCU-014
Flush Mount Kit FP03-09870 008-535-630 For control unit
OP03-198 001-008-050
Connection OP03-183 008-535-640 RCU-014QMU-201CR
Stand OP03-185 008-535-660 RCU-014
Hanger Kit FP03-10201 008-539-530 Desktop inst. kit for CU-200-FAR
BNC DSUB-BNC-1 000-148-528 For connecting VDR
Connector
Converter
Switching Hub HUB-100 – See Operator's Manual for HUB-100,
issued separately.
Hood FP03-11500 001-020-090 For MU-201CR display unit
Slim Hood FP03-11510 001-034-390 For MU-201CR display unit
v
This page is intentionally left blank.
vi
1. MOUNTING
NOTICE
Do not apply paint, anti-corrosive sealant
or contact spray to coating or plastic
parts of the equipment.
Siting
• No funnel, mast or derrick should be within the vertical beamwidth of the antenna unit in the bow
direction, especially zero degrees ±5°, to prevent blind sectors and false echoes on the radar
picture.
• Deposits and fumes from a funnel or other exhaust vent can adversely affect the aerial perfor-
mance and hot gases may deform the radiator. The antenna unit must not be mounted where
the temperature is more than 70°C.
• Locate a direction finder antenna clear of the antenna unit to prevent interference to the direc-
tion finder. A separation of more than two meters is recommended.
• Choose a location where reflections from the radar reflector will not be received by the radar
antenna.
• The "standard" antenna unit orientation has the cable glands directed toward the bow.
• Leave sufficient space around the unit for maintenance and servicing. See the antenna unit out-
line drawing for recommended maintenance space.
Mounting
• Use rope and crane to hoist the antenna unit to the mounting location. Lifting fixtures are pro-
vided on the antenna chassis to which to fasten rope.
• Mount the unit parallel to the waterline.
• A hole is required in the mounting platform for the antenna cable.
• An appropriate platform should be constructed at the mounting location to facilitate installation
and maintenance work.
• Connect ground wire between antenna terminal on antenna chassis and ground point.
• If the mounting platform is made of steel paint it to prevent electrolytic corrosion. DO NOT paint
the antenna radiator.
1-1
Assembling the antenna unit
The antenna unit should be assembled before mounting it. Follow the procedure below to
assemble the antenna unit. The numbers in parentheses refer to the parts numbers shown in the
illustration on the next page.
1. Grease the O-ring(1) and set it to the O-ring groove in the flange on the rotation coupler on the
antenna base. Fasten the feeder waveguide to the antenna base with hex bolts B(2). Coat the
surface of the waveguide flange with silicon rubber, referring to the illustration below for instruc-
tions.
2. Loosely fasten the antenna radiator to the antenna base with hex bolts(3) and(6), flat
washers(5) and (7), spring washers(4) and (8) and hex nut(9).
3. Grease the O-ring(1) for the antenna radiator and set it to the O-ring groove on the feeder
waveguide flange on the antenna radiator. Fasten the feeder waveguide to the antenna radiator
with hex head bolts(2).
4. Fasten the waveguide clamp(13) to the waveguide clamp insulator(14) with hex head bolt(10),
flat washer(12) and spring washer(11).
5. Securely fasten the antenna radiator to the antenna base.
Silicon
O-ring rubber
Choke guide
O-ring
Silicon rubber
1-2
Antenna Radiator
Rotation Coupler
Antenna Base
Feeder Waveguide
1-3
How to hoist antenna unit
1. Referring to the illustration below, fasten rope A of approx. 85 cm in length and fasten rope B
of approx. 100 cm in length.
2. Place protective material (cardboard, foam, etc.) between rope and radiator at the asterisk-
marked locations shown below, to prevent damage to the radiator.
3. Hoist the antenna slightly and confirm that the load applied to the radiator is not excessive. (If
load is excessive, lower the antenna unit and adjust lengths of ropes.)
4. Hoist the antenna unit to the mounting location.
A B
1-4
Fastening antenna unit to the mounting platform
WARNING
Do not open the equipment unless
totally familiar with electrical circuits
and service manual.
Note: The antenna unit is made of cast aluminum, which is subject to electrolytic corrosion if the
mounting platform is steel or iron. To prevent electrolytic corrosion, use the supplied seal washers
and corrosion-proof rubber mat.
Fix the antenna unit to the mounting location, referring to the procedure below and the illustration
on the next page.
1. Referring to the antenna unit outline drawing, prepare a mounting platform at the mounting
location for the antenna unit.
2. Lay the corrosion-proof rubber mat (supplied) on the mounting platform, aligning the holes on
the rubber mat with the fixing holes on the mounting platform.
3. Lay the antenna unit on the rubber mat, orienting it so the cable gland is directed toward ship's
bow.
4. Use hex bolts (M12×60), nuts, flat washers and seal washers to fix the antenna unit to the
mounting platform.
5. Arrange the ground point at a location on the mounting platform that is within 300 mm from the
ground terminal on the antenna unit. Fasten the ground wire (RW-4747, 340 mm) there, using
the M6×25 hex bolt, nut and washers.
6. Connect the other end of the ground wire to the ground terminal on the antenna unit.
7. Coat the ground terminal, ground point on the mounting platform and fixing bolts on the
antenna unit with anticorrosive sealant (supplied).
1-5
Coat with Seal washer
anticorrosive sealant.
Corrosion-
proof rubber
mat
Hex bolt
Ground Spring washer
wire
Flat washer
Spring washer
Hex nut
Anticorrosive
sealant
Hex nut
Ground Spring washer
wire Flat washer
Hex bolt
1-6
1.2 Monitor Unit
The monitor unit is can flush mounted in a panel or mounted on a desktop (requires optional
accessories).
The FAR-2157-BB is not equipped with a monitor unit. Procure a suitable monitor unit locally. Rec-
ommended monitor: SXGA (1280×1024), aspect ratio 5:4.
Mounting considerations
When selecting a mounting location, keep in mind the following points:
• Select a location where the screen can be viewed conveniently while facing the bow.
• Locate the unit out of direct sunlight and away from heat sources because of heat that can build
up inside the cabinet.
• Locate the unit away from places subject to water splash and rain.
• Leave sufficient space on the sides and rear of the unit to facilitate maintenance, referring to the
outline drawing for maintenance space.
• The monitor unit will give interference to a magnetic compass if it is placed too close to the com-
pass. Observe the compass safe distances on page ii to prevent interference to the compass.
Mounting procedure
Flush mounting
Follow the procedure below to mount the monitor unit in a console.
1. Make a cutout in the mounting location referring to the outline drawing shown below.
2. Set the monitor unit to the hole and fix it with four self-tapping screws (6×30).
3. Attach panel hooks near the fixing holes (upper part). See next page. These are used to pull
out the monitor unit from the panel for servicing.
4. Attach four panel covers to the fixing holes.
506 1 4-FIXING HOLES
296 1
296 1
420
454
(79)
1-7
Panel hook
Panel cover
Fixing screw
Desktop mounting
Use the optional desktop mouting kit (Type: FP03-09820, Code No.: 008-535-560) to mount the
monitor unit on a desktop.
Contents of desktop mounting kit FP03-09820
1. Assemble two hangers and hanger stay with two hex bolts (M10×30), flat washers and spring
washers and cover each hex bolt with hole plug.
2. Fix the above assembly to the mounting location with four hex bolts (M12, dockyard supply).
3. Fasten the monitor unit to the mounting hanger assembly with four hex bolts (M6×25, supplied).
4. Cover each hex bolt with a panel cover (4 pcs.).
5. Cover fixing holes for hand grips with snap buttons (4 pcs).
1-8
Hanger (L)
Hanger stay
Hanger (R)
Panel cover
Snap button
Hex bolt Flat Washer M10
(M6x25) Spring Washer M10
Hex bolt
M10x30
Hole plug
Panel cover
Hand grip
Attaching hood
When it is too bright in the daytime, use the optional hood (Type: FP03-11500, Code No.: 001-
020-090) to shade the screen.
Contents of hood
1-9
1. Desktop mounting: Fasten the fixing plates to the fixing holes with the hex head bolts (sup-
plied).
Flush mounting: Fasten the display unit to the mounting location, and then attach the fixing
plates with four self-tapping screws.
Fixing plate
Fixing hole
2. Attach the hood to the display unit (the hood is outside of the fixing plates).
3. Fasten the hood to the fixing plates with four screws supplied (M4x10).
Mounting procedure
Fixing with KB (keyboard) fixing plate
The KB fixing plate sits the control unit at a comfortable angle, like the retractable legs on a PC
keyboard.
1. Fix the KB fixing plate to the bottom of the control unit.
2. Attach cushions (three for RCU-014, two for RCU-015/RCU-016) to the bottom of the control
unit as shown below.
3. Fix the unit to a desired location with self-tapping screws (local supply).
1-10
Fixing without KB fixing plate
1. Drill four mounting holes of 5 mm diameter, referring to the outline drawing at the back of this
manual.
2. Fix the control unit with four screws (M4) from the under side of the desktop. (M4 screws with
a sufficient length for the thickness of the desktop should be provided locally.)
#70
136±1
180
# Minimum recommended service space 4-M4 (Fixing holes)
308±1 (bottom)
398
24 32
F1
136±1
180
F2
F3
F4
1-11
Flush mounting
Use the optional flush mount kit FP03-09870 (Code No. 008-535-630) to flush mount the control
unit RCU-014, RCU-015 and/or RCU016 in a console.
Contents of flush mount kit for RCU-014/015/016
170±2 176±2
388 ±2 150±2
Flush mount cutout for RCU-014 Flush mount cutout for RCU-015 and RCU-016
2. Set the control unit to the cutout.
3. From the rear side, attach the mounting plate to the control unit with four screws.
4. Screw the wing screw to each mounting plate and then insert hex bolt to each wing screw.
5. Fasten each wing screw and then fasten the hex nuts as shown in the figure below.
#70
#70
(P)
53
53
(P)
86
92
171
Note: P <
=10
Flush mount mounting dimensions for control unit RCU-014 (left) and RCU-015/RCU-016
1-12
Connecting RCU-016 in series with RCU-014
1. Pass the cable from RCU-016.
2. Plug in connector
to J502.
3. Clamp the copper part of the cable with the cable clamp.
1-13
Changing the cable entrance on control unit RCU-015/RCU-016
To change the cable entrance from the side (default) to the bottom, modify the unit as shown
below.
Screw M3X8
(torque: 10.78 Nm)
Bottom of unit
Cable clamp
3. Pass cable thru this hole. 03-163-7804
Screw M4X8
(torque: 1.47 Nm)
4. In here, clamp copper part
of cable with cable clamp
removed at step 1. 1. Remove cable
clamp.
1-14
1.4 Processor Unit
Mounting considerations
When selecting a mounting location, keep in mind the following points:
• Locate the processor unit away from heat sources because of heat that can build up inside the
cabinet.
• Locate the unit away from places subject to water splash and rain.
• Leave sufficient space at the sides and rear of the unit to facilitate maintenance, referring to the
outline drawing.
• A magnetic compass will be affected if the processor unit is placed too close to it. Observe the
compass safe distances on page ii to prevent interference to a magnetic compass.
Mounting procedure
Fix the unit with four M6 bolts or self-tapping screws.
2-φ7 FIXING HOLES
#50
385
25
370±1
# Minimum recommended
service space
340±1
380
410
R3
.5
7
350±1 2-FIXING NOTCH
Do not unfasten
this screw.
1-15
1.5 Power Supply Unit
Mounting considerations
The power supply unit may be mounted on a bulkhead or a deck. Because it has no operation
requirements it can be located almost anywhere, provided the location is well ventilated.
Mounting procedure
Fix the unit to the mounting location with four 6×20 self-tapping screws (local supply). For
mounting on a bulkhead, do the following:
240±1 2-φ7
FIXING
#50
9
HOLE
420±1
WINDOW
440
LED
TERMINAL
TERMINAL
R3
.5
(11)
7 GND
240±1 TERMINAL
#: MAINTENANCE SPACE
Mounting dimensions for power supply unit
1-16
2. WIRING
ANTENNA UNIT
TPYCY-2.5
TPYCY-1.5
POWER
SUPPLY
UNIT
24 VDC
200 VAC, 3φ, 50 Hz
INTERFACE
100-115 VAC/220-230V, CU-200-FAR
1φ, 50/60 Hz
440 VAC, RU-1803 XH10P-W-5P
100-230 VAC
1φ, 50/60 Hz L=10/20/30 m
1φ, 50/60 Hz
XH10P-W-6P L=1.5/10/20/30m
DPYC-2.5 CONTROL UNIT
(RCU-016)
F2
1φ, 50/60Hz F3
F4
2-1
2.2 Antenna Unit
Terminal strip
Cover Cover
20 mm 550 mm
5 mm
500 mm
Coaxial cable
Vinyl wire
Shield
Taping
6
14 5 9
Unravel armor.
Core
Fold back shield.
Shield
Crimp-on lug Coaxial cable
2-2
4. In the order shown in the figure below, pass the gland nut, flat washers (3 pcs.) and gasket onto
the signal cable.
Armor Gasket Signal cable
5. As shown in the figure below, fold back the armor onto flat washer (2) and insert remaining
armor through flat washer (3). Cut off the part of the armor that protrudes past the flat washers
(2) and (3).
Fold back armor
Flat washer
(3)(2) (1)
6. Lead the signal cable through its cable gland and then into the chassis. Coat the threaded part
of gland nut with sealant (supplied) and then tighten the nut.
TB801
PCB 03P9436
2-3
7. Using the terminal opener provided, connect cores (except coaxial cable) to their appropriate
locations on TB801 on the PCB 03P9436. Refer to the interconnection diagram for wiring
details.
Push down.
Terminal
Procedure
opener
1. Twist core.
2. Insert terminal opener as shown and push down.
3. Insert core into hole.
Wire
4. Release terminal opener.
WAGO connector 5. Tug on wire to confirm that it is firmly in place.
Twist.
TB802 on
PCB 03P9435
2-4
8. Connect coaxial cable to TB802 on the PCB 03P9435. Fix the shield and conductor as shown
below.
Fasten shield by clamp.
NOTICE
Fasten BARE conductor. Do not
use a crimp-on lug, to prevent
Taping Fasten conductor increased contact resistance.
with screw.
2-5
Fabricating HV cable TYPCY-1.5 and power cable TYPCY-2.5
1. Unfasten the gland nut for the HV cable and remove gasket, flat washers (3 pcs.) and gland
cap. (The gland cap may be discarded.)
2. Fabricate the HV cable as shown below.
20 mm Armor
5 mm
Sheath Sheath
FV2-4
600 mm
Vinyl Armor Conductor
sheath S = 1.50 mm2
φ = 1.56 mm
SECTIONAL VIEW
HV cable
2-6
8. Fabricate the power cable as shown below.
Armor
25 mm Sheath
5 mm
Sheath
FV2-4 Conductor
500 mm S = 2.50 mm2
φ = 2.01 mm
Vinyl sheath Armor
SECTIONAL VIEW
Power cable
CAUTION
High voltage is present at the No. 6 pin
of TB901. Miswiring at this pin can
damage the antenna unit.
2-7
2.3 Monitor Unit
Two cables are terminated at the monitor unit: the signal cable from the processor unit (5 m or 10
m cable) and the power cable from the ship's mains. The signal cable comes with a connector pre-
attached to it for connection to the monitor unit. Fabricate the power cable as below. Use cable
DPYC-2.5 (Japan Industry Standard) or the equivalent. Be sure to ground the unit, with IV-8sq
wire (local supply). For MU-190, see the applicable Oprator’s Manual.
Note: Pass the AC line through a double-contact breaker (shipyard supply). Further, for vessels
where the power line is grounded, connect one end of the line to the C (common) terminal and the
other end to the H terminal.
Armor
Approx. 40 mm
Armor
35 mm
(2) Conductor
S = 2.5 mm2
Vinyl sheath φ = 2.01 mm
SECTIONAL VIEW
10 mm
(3)
(4),
(5) Crimp-on lug
Taping
2-8
2.4 Processor Unit
Four cables are terminated at the processor unit: the antenna unit cable, monitor unit cable (FAR-
2157 only), control unit cable and the power cable. Cables other than the power cable come with
a connector preattached to them. Fabricate the power cable as below.
Note: Pass the AC line through a double-contact breaker (shipyard supply). Further, for vessels
where the power line is grounded, connect one end of the line to the C (common) terminal and the
other end to the H terminal.
Armor
Approx. 40 mm
Armor
35 mm
(2) Conductor
S = 2.5 mm2
Vinyl sheath φ = 2.01 mm
SECTIONAL VIEW
10 mm
(3)
(4),
(5) Crimp-on lug
Taping
2-9
Connection of cables
The power cable is connected to the terminal board on the rear panel and the signal cable from
the monitor unit is connected to the DVI-D connector. Other cables are connected to the printed
circuit board 03P9342. Be sure to ground the unit, with IV-8sq wire (local supply).
Monitor unit Cable clamp for power cable
Remove the
protective cover.
F70
FUSE
15
1
DC/AC F1
2
Control unit**
Heading senor
Power cable Speed log
Navigator
21 2 3 4 5 6 18 19 20
9 14 17 HDG RSD
φ9
ACK
φ18.9
24 24' 26
1 7 8 28 φ7.4
VDR IN
φ7
VDR OUT
GYRO PSU004
AIS AD100
**: The configuration of optional cable between the processor unit and the control unit is as follows.
Note that the cable fabrication for each end is different.
160 m
mm 50m
3
2-10
Location of connectors
Open the processor unit as shown below to access the 03P9342 board, which is for connection
of external equipment.
Cable clamp
J654
Tx HV line
Coaxial wire
2-11
Cable fabrication for the cables connected to the 03P9342 board
Signal cable RW-9600 (Between antenna unit and processor unit)
Vinyl sheath Armor Shield
60 450
14 5 9
L: According to location
of connector.
6
Armor
Armor 60: Peel paint.
Shield
Sheath
Shield
φ = 10.1 mm
L= Depends on equipment L Conductor
connected. Measure at S = 0.75 mm 2
5 φ = 1.11 mm
processor unit.
TTYCS-1
Sheath
6 φ = 16.3 mm
Shield
Fasten cable clamp here. Conductor
S = 0.75 mm 2
φ = 1.11 mm
TTYCS-4
2-12
Wiring WAGO connector Fastening coaxial cable
Push down.
Fasten shield
by clamp.
Terminal opener
Connection of Sub-display
A conventional remote display and/or FAR-2xx7 series radar can be connected to J617 (FULL-
LOG) and J618 (SEMI-LOG) in the processor unit as a sub-display. However, the control for GAIN
and STC are different depending on J617 and J618. Refer to the table to connect sub-displays.
2-13
2.5 Power Supply Unit
Wire the power supply unit referring to the interconnection diagram. Be sure to ground the unit,
with IV-8sq wire (local supply).
Note 2: Pass the AC line through a double-contact breaker (shipyard supply). Further, for vessels
where the power line is grounded, connect one end of the line to the C (common) terminal and the
other end to the H terminal.
CAUTION
High voltage is present at the
No. 6 pin of TB3. Miswiring at
this pin can damage the unit.
Ground
FV2-4
120
2-14
Terminal TB2: cable TPYC-2.5 (for antenna motor)
Terminal TB3: #11-#13, cable TYPC-1.5 (between power control section and processor)
See page 2-5 for sectional views of these cables if using equivalent cables.
Armor 30: Peel paint
FV2-4
L
Terminal TB3: #1-#3 TPYCY-2.5 (between power control section and antenn)
Terminal TB3: #6, #8, #9 TPYCY-1.5 (between power control section and antenna)
Vinyl sheath Armor
FV2-4
30 L
L: 80 (For TPYCY-2.5)
120 (For TPYCY-1.5)
Armor
φ = TYPCY-1.5: 14.5 mm Sheath
TPYCY-2.5: 15.5 mm
Conductor
S= TPYCY-1.5: 1.52 mm, TPYCY-2.5: 2.52 mm
φ = TPYCY-1.5: 1.56 mm, TPYCY-2.5: 2.01 mm
2-15
2.6 Changing AC Power Specification
To change AC power specification from 100 VAC to 220 VAC and vice versa, change fuse and
jumper wire settings and adjust the overvoltage detection circuit, following the instructions in this
section.
Processor unit
Add or remove jumper connector P108 from the PWR board 03P9339 and change the fuse in the
processor unit according to ship's mains. Then, adjust the overvoltage detection circuit, the pro-
cedure for which is shown on the next page.
Note: When switching from 220 VAC to 100 VAC, construct a jumper connector locally, referring
to the illustration on the next page. (VH8 connector housing is to be plugged into J108.)
Fuse
TB1
PWR board
2-16
J105 J106 (P)HV
J103
R21
(OVER)
J101
P108/J108 AC FIL
87654321
Jumper connector
(VH8P)
2-17
Power supply unit
Refer to the illustration and table below to add (or remove) jumper connector P8 from the TX-HV
Board (03P9350) and change fuse.
After completing jumper and fuse arrangements, adjust the overvoltage detection circuit, using a
variable transformer.
Note: When switching from 220 VAC to 100 VAC, construct a jumper connector locally, referring
to the illustration below. (VH6 connector housing is to be plugged into J8.)
P8/J8
654321
Unfasten four screws and remove
cover for TX-HV Board.
Jumper connector
(VH6P)
CR23
R21
TX-HV Board
Fuse
TB1
2-18
3. ADJUSTMENTS
This section provides the information necessary for setting and adjusting the radar, which is car-
ried out from the radar's menu system. Menus may be accessed from the keyboard or on-screen
menu in case of Control Unit RCU-014, or on-screen menu in case of Control Unit RCU-015.
The menu illustrations in this chapter show default settings in bold face.
[ECHO]
1 BACK
2 2ND ECHO REJ
OFF/ON
3 TUNE INITIALIZE
4 PM
OFF/ON
5 SART
OFF/ON
6 WIPER
OFF/1/2
7 ECHO AREA*1 *1 Not available on IMO or A type radar
CIRCLE/WIDE/ALL
8 [PICTURE SELECT]
ECHO menu
5. Spin the thumbwheel to choose 3 TUNE INITIALIZE.
6. Push the thumbwheel to initialize automatic tuning.
In a few moments echoes appear on the screen. The message "TUNE INITIALIZE" appears (in
red) during automatic tuning. When this message disappears, the tuning is completed. If nec-
essary adjust the [GAIN] control to show echoes clearly.
7. Push the right button twice to close the menu.
3-1
3.2 Heading Alignment
You have mounted the antenna unit facing straight ahead in the direction of the bow. Therefore,
a small but conspicuous target dead ahead visually should appear on the heading line (zero
degrees). In practice, you will probably observe some small bearing error on the display because
of the difficulty in achieving accurate initial positioning of the antenna unit. The following adjust-
ment will compensate for this error.
Correct bearing α
relative to heading
Target
350 000 010
α
340 020
330 030
320 040
310 050
300 060
290 070
280 080
270 090
230 130
220 140
210 150
200 160
190 180 170
Apparent position β
of target
β Target 320
330
340
350 000 010
020
030
040
310 050
300 060
290 070
280 080
270 090
230 130
220
210
200 160
150
140
heading
190 180 170
Heading alignment
1. Select a stationary target echo at a range between 0.125 and 0.25 nm, preferably near the
heading line.
2. Operate the EBL control to bisect the target echo:
a) Roll the trackball to place the arrow in the EBL1 or EBL2 box (at bottom left corner), whichever
EBL you want to use.
b) Push the left button to turn on the EBL.
c) Push the left button again to send the cursor inside the effective display area.
d) Roll the trackball (coarse adjustment) or spin the thumbwheel (fine adjustment) to bisect the
target with the EBL.
3. Read the target bearing.
4. Measure the bearing of the stationary target on the navigation chart and calculate the difference
between actual bearing and apparent bearing on the radar screen.
5. Left-click the MENU box at the right side of the screen to close the menu.
3-2
6. For Control Unit RCU-014:
a) While pressing and holding down the [HL OFF] key, press the [MENU] key five times.
b) Press the [0] key to show the INITIALIZE menu.
For Control Unit RCU-015:
See the procedure on the next page for how to show the INITIALIZE menu.
[INITIALIZE]
1 BACK
2 [ECHO ADJ]
3 [SCANNER]
4 [INSTALLATION]
5 [OWN SHIP INFO]
6 [ARP PRESET]
7 [NETWORK]
8 [OTHER]
INITIALIZE menu
7. RCU-014: Press the [2] key to open the ECHO ADJ menu.
RCU-015: Choose 2 ECHO ADJ and then push the thumbwheel.
[ECHO ADJ]
1 BACK
2 CABLE ATT ADJ
AUTO/MANUAL
30
3 HD ALIGN
000.0°
4 TIMING ADJ
0
5 MBS
0
6 DEFAULT ANT HEIGHT
5/7.5/10/15/20/
25/30/35/40/45/
more 50 m
7 NEAR STC CURVE
2/2.5/3/3.5/4.2
8 MID STC CURVE
3/4/5/6
9 FAR STC CURVE
6/7/8
0 RING SUPPRESSION
0
3-3
How to access the INITIALIZE Menu with Control Unit RCU-015
3-4
3.3 Adjusting Sweep Timing
Sweep timing differs with respect to the length of the signal cable between the antenna unit and
the processor unit. Adjust sweep timing to prevent the following symptoms:
• The echo of a "straight" target (for example, pier), on the 0.25 m range, will appear on the dis-
play as being pulled inward or pushed outward. See the figure below.
• The range of target echoes will also be incorrectly shown.
[ECHO ADJ]
1 BACK
2 CABLE ATT ADJ
AUTO/MANUAL
30
3 HD ALIGN
000.0°
4 TIMING ADJ
0
5 MBS
0
6 DEFAULT ANT HEIGHT
5/7.5/10/15/20/
25/30/35/40/45/
more 50 m
7 NEAR STC CURVE
2/2.5/3/3.5/4.2
8 MID STC CURVE
3/4/5/6
9 FAR STC CURVE
6/7/8
0 RING SUPPRESSION
0
3-5
3.4 Suppressing Main Bang
If main bang appears at the screen center, suppress it as follows.
1. Transmit the radar on a long range and then wait ten minutes.
2. Adjust gain to show a slight amount of noise on the display.
3. Select the 0.25 nm range. Adjust sea clutter control to suppress sea clutter.
4. On the ECHO ADJ menu, choose 5 MBS.
[ECHO ADJ]
1 BACK
2 CABLE ATT ADJ
AUTO/MANUAL
30
3 HD ALIGN
000.0°
4 TIMING ADJ
0
5 MBS
0
6 DEFAULT ANT HEIGHT
5/7.5/10/15/20/
25/30/35/40/45/
more 50 m
7 NEAR STC CURVE
2/2.5/3/3.5/4.2
8 MID STC CURVE
3/4/5/6
9 FAR STC CURVE
6/7/8
0 RING SUPPRESSION
0
3-6
3.5 Other Settings
ECHO menu setting
Open the ECHO ADJ menu as described on page 3-3 and 3-4.
[ECHO ADJ]
1 BACK
2 CABLE ATT ADJ
AUTO/MANUAL
30
3 HD ALIGN
000.0°
4 TIMING ADJ
0
5 MBS
0
6 DEFAULT ANT HEIGHT
5/7.5/10/15/20/
25/30/35/40/45/
more 50 m
7 NEAR STC CURVE
2/2.5/3/3.5/4.2
8 MID STC CURVE
3/4/5/6
9 FAR STC CURVE
6/7/8
0 RING SUPPRESSION
0
To adjust the cable attenuation manually, choose MANUAL and push the thumbwheel. With
the gain set to 80, spin the thumbwheel until noise just appears on the screen. Default setting is
30 for the antenna cable length of 15 m. The setting range is 0 to 73.
To adjust the cable attenuation automatically, choose AUTO and push the thumbwheel. The
message "CABLE ATT ADJ" appears (in red) at the bottom of the screen. It takes about five min-
utes to complete the adjustment, after which the radar goes into stand-by.
NEAR STC CURVE, MID STC CURVE AND FAR STC CURVE
The default setting is suitable for most conditions. If necessary, change the setting according to
sea conditions.
RING SUPPRESSION
This is mainly used to removes "ring" noise that appears in the waveguide-type radar. Adjust so
the rings disappear at the range of 0.125 nm. The setting range is 0 to 255.
3-7
SCANNER menu
1. Open the INITIALIZE menu as described on page 3-3 and 3-4.
2. Choose 3 SCANNER to open the SCANNER menu.
[SCANNER]
1 BACK
2 BLIND SECTOR 1
START 000°
ANGLE 000°
3 BLIND SECTOR 2
START 000°
ANGLE 000°
4 ANT REVOLUTION
LO/HI/AUTO
5 ANT SW
OFF/ON/EXT
6 ANT STOPPED
STBY/TX
7 M SPEC
OFF/ON
8 BB TYPE
NORMAL/BB
SCANNER menu
ANT REVOLUTION
No use.
M SPEC
No use.
BB TYPE
Choose type of radar. Select "BB" for FAR-2157-BB.
3-8
INSTALLATION menu
Open the INSTALLATION menu by choosing 4 INSTAL-
LATION from the INITIALIZE menu. [INSTALLATION]
1 BACK
RADAR 2 RADAR*1
MAIN/SUB
Automatically selected to MAIN when 4 RADAR NO is 3 RANGE UNIT*2
selected to 1-4; SUB when the same item is selected to NM/SM/km/kyd
5-8. 4 RADAR NO*3
1/2/3/4/5/6/7/8
RANGE UNIT 5 RADAR POSN
FORE/MAIN TOP/
Choose NM, SM, km or kyd (kilo yard) as appropriate. For MAIN 2ND/MAIN 3RD/
the IMO- and A-type radars the range unit is fixed at "NM". AFT/PORT/
STARBOARD
RADAR NO and RADAR POSN 6 MODEL
6/12/25 UP/25 DOWN/
For multiple radar system using the network hub, set 50/30 UP/30 DOWN/60
number (name) and antenna position for each system, to 7 TYPE
IMO/A/B/C/W
easily distinguish radars from one another. 8 ON TIME
XX.XH
MODEL 9 TX TIME
XX.XH
Choose "50".
*1: No selection
TYPE
*2: Not shown on IMO- or A-type radar.
Choose radar type from among the following options: *3: No.1-4: with antenna unit
No.5-8: without antenna unit
IMO: IMO compliant
INSTALLATION menu
A: Near-IMO specifications
B: International fishing vessels
C: Japanese flag vessels
W: Washington state (USA) ferry
3-9
OWN SHIP INFO menu
Open the OWN SHIP INFO menu by choosing 5 OWN SHIP INFO from the INITIALIZE menu.
[OWNSHIP INFO]
1 BACK
2 LENGTH/WIDTH
LENGTH 100 m
WIDTH 50 m
3 SCANNER POSN
BOW 0m
PORT 0 m
4 SUB SCANNER POSN
BOW 0m
PORT 0 m
5 GPS1 ANT POSN
BOW 0m
PORT 0 m
6 GPS2 ANT POSN
BOW 0m
LEFT 0 m
7 CONNING POSN
BOW 0m
PORT 0 m
LENGTH: 0 to 999 m
WIDTH: 0 to 999 m
BOW: 0 to 999 m
LEFT: 0 to 999 m
CONNING POSN
Enter the conning position, from the bow and left side. The setting ranges are the same as those
shown on the preceding page. When you set the reference point as the conning position, these
values are used to correct the radar antenna position.
Note: If two or more radars are installed, all items on the OWN SHIP INFO menu should be the
same except 3 SCANNER.
3-10
ARPA PRESET menu
Open the ARPA PRESET menu by choosing 6 ARP PRESET from the INITIALIZE menu.
1 BACK 1 BACK
2 TTM OUTPUT [ACQ PRESET] 2 GATE SIZE
OFF/REL/TRUE 1 BACK S/ M /L/LL
3 MAX RANGE 2 LAND SIZE 3 FILTER RESPONSE
24/32 800 M 1/ 2 /3/4
4 ECHO LEVEL 3 ANT SELECT 4 LOST COUNT
16 XN12AF/XN20AF/ 9 SCAN
5 QV DISPLAY XN24AF/XN4A/XN5A 5 MAX SPEED
OFF/ON SN30AF/SN36AF/ 100 KTS
6 ARP W/O GYRO* SN4A/SN5A 6 TRACKING MODE
OFF/ON 4 AUTO ACQ CORRE 1 /2/3/4
7 [ACQ PRESET] 5 SCAN 7 START TIME TGT VECT
8 [TRACK PRESET] 5 AUTO ACQ WEED TIME /SCAN
9 [ARP SENSOR DATA] 1 SCAN 50 SEC
0 DEFAULT 20 SCAN
ARP-related menus
TTM OUTPUT
Set the output format of tracked targets among OFF, REL and TRUE.
OFF: No output
REL (relative):Target bearing from own ship, degree relative.
Target course, degree relative.
TRUE: Target bearing, degree true.
Target course, degree true.
Note: The TTM OUTPUT port changes according to the setting for INS as described on page 3-
13.
MAX RANGE
Choose the maximum ARPA tracking range, 24 or 32 nm.
ECHO LEVEL
Set echo detection level. The setting range is 1 to 31.
QV DISPLAY
OFF: Normal picture
ON: Quantized picture. Always off at power on.
3-11
LAND SIZE
Set the minimum echo size to be considered a landmass. The setting range is 100 to 1000 m, in
increments of 100 m.
ANT SELECT
Set the model of antenna radiator used.
GATE SIZE
Set the gate size among S, M, L, or LL.
FILTER RESPONSE
Set the filter response function. The setting range is 1 to 4. Choose 1 for better trackability; 4 for
better stability.
LOST COUNT
Set the number of consecutive "no echoes" before an acquired target is declared as a lost target.
The setting range is 1 to 20.
MAX SPEED
Set the maximum tracking speed. The setting range is 40 to 150.
TRACKING MODE
Set the tracking mode among 1 to 4.
3-12
OTHER menu
Open the OTHER menu by choosing 8 OTHERS from the INITIALIZE menu.
[OTHERS]
1 BACK
2 DEMO ECHO
OFF/EG/SPU/PC
3 EAV w/o GYRO
OFF/ON
4 ARP SELECT
ARPA/ATA
5 INS
OFF/SERIAL/LAN
OTHER menu
ARP SELECT
Choose ARPA or ATA depending on your radar system.
INS
Choose appropriate item according to the ECDIS connected.
OFF: No connection
SERIAL: When connecting FEA-2105 series ECDIS.
LAN: When connecting FEA-2107 series ECDIS.
3-13
This page intentionally left blank.
3-14
4. OPTIONAL EQUIPMENT
This section explains how to install the GC-10 (mainly consisting of the GYRO CONVERTER
board) and set it up according to the gyrocompass connected.
3
12
3
1
7
3
1
1
1
5
1
1
1
12
4-1
2. Fasten the GYRO CONVERTER board inside the processor unit with five washer head screws.
3. Fix connector 231-607/019-FUR (called J602) with two screws.
Screw
GYRO CONVERTER board
M3X8 5 pcs
64P1106A
Screw
M2.6X10 2 pcs
Connector (231)
231-107/026-FUR
1
7
Connector (231)
231-607/019-FUR
PCB 03P9342
4-2
5. Connect J602 (attached at step 3) to the GYRO CONVERTER board with two VH connector
assemblies 03-2089 (3P) and 03-2090 (5P).
PPL P608
7 6 5 4 3 2 1
1 2 3 4
GRN ORG
YEL
ORG RED
BRN
From J5 RED
BRN
WAGO connector
Twist
Wire
Procedure
1. Twist core.
2. Press terminal opener downward.
2 VH connector assy. 3. Insert wire to hole. 1 NH connector assy.
4. Remove terminal opener.
03-2089 (5P) 5. Pull wire to confirm that it is secure. 03-2091 (5P)
2 VH connector assy.
To J602 XH-PH connector assy.
03-2090 (3P)
To P608 03-2088 (6-14P)
P5
P4 P7
P1
P603
J5 GYRO CONVERTER J1
4
J4 64P1106A
1
P608
3
12
J7
3
1
J602
7
1
1
J603
5
1
1
1
12
TB
03P9342
1
4-3
7. Pass the gyrocompass cable through the cable clamp and connect it to connector J602 as
shown in the figure below.
8. Attach the clamps to the plastic cover and then attach the cover to the GYRO CONVERTER
board as shown in the figure below. Pass cables thru the clamp ED-1.
Screw
Plastic cover M4X8 3 pcs
Clamp CKS-10-L
Clamp EDS-1
3
12
3
1
1
1
1
1
1
1
12
4-4
Connection of external power supply
An external power supply is necessary when the repeater signal is step-by-step type and the step
voltage is below 20 V or output voltage is less than 5 W.
1. Cut jumper wire JP1 on the GYRO CONVERTER board when an external power supply is
used.
2. Connect the gyrocompass cable and power cable as shown below.
GYRO CONVERTER board
[A] 64P1106
J4
S1
1 > S1
Gyrocompass S2 2 > S2
(Step type) S3 3 > S3
COM
4>T
F.G. 5 > F.G.
AC synchronous signal:50/60 Hz
Rotor voltage: 60 V to 135 V AC
Stator voltage: 60 V to 135 V AC
Gear ratio: 360x
Supply voltage: 30 V to 135 V AC
If the specifications of the gyrocompass differ from those mentioned above, change jumper wire
and DIP switch settings on the GYRO CONVERTER board. Settings may be changed according
to gyrocompass specifications (see page 4-6) or make and model of gyrocompass (see page 4-
7). For the location of DIP switches and jumper wires, see page 4-8.
Note: If you change the setting with the power turned on, set #8 of SW2 from OFF to ON, then
OFF again to effect changes.
4-5
Setting method 1: DIP switch settings and gyrocompass specifications
1) Gyrocompass type 2) Frequency
Gyrocompass SW SW SW SW SW
JP1 Frequency Remarks
type 1-4 1-5 1-6 1-7 1-8
AC synchronous OFF OFF OFF #1, #2, #3 50/60 Hz OFF OFF AC synchronous-
pulsating current
DC synchronous OFF OFF OFF #2, #3, #4 400 Hz ON OFF AC synchronous-
pulsating current
DC step ON OFF OFF #4, #5, #6 500 Hz OFF ON AC synchronous-
pulsating current
Full-wave OFF ON OFF #4, #5, #6 DC ON ON DC synchronous
pulsating current DC step
Half-wave ON ON OFF #4, #5, #6
pulsating current
3) Rotor voltage (between R1 & R2) 4) Stator voltage (between S1 & S2)
Rotor Voltage SW2-1 JP3 Stator Voltage SW2-2 SW2-3 JP2
20 to 45 VAC ON #2 20 to 45 VAC, or 20 to 60 VDC ON OFF #2
30 to 70 VAC OFF #2 30 to 70 VAC, or 40 to 100 VDC OFF OFF #2
40 to 90 VAC ON #1 40 to 90 VAC ON OFF #1
60 to 135 VAC OFF #1 60 to 135 VAC OFF OFF #1
4-6
Setting method 2: by make and model of gyrocompass
Maker Models Specification SW SW SW SW SW SW SW SW SW SW SW JP 1 JP 2 JP 3 JP 4 JP 5
1-1 1-2 1-3 1-4 1-5 1-6 1-7 1-8 2-1 2-2 2-3
Anschutz Standard 2,3 AC synchronous OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF #1, #2 #2 #1
1 #
50/60Hz #2,#3
Rotor voltage: 50/60V
Stator voltage: 22V
360x
Standard 4,6 AC synchronous OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF #1, #2 #1 #1
1 #
50/60Hz #2,#3
Rotor voltage: 50/60V
Stator voltage: 90V
360x
Standard 20 DC step ON OFF OFF ON OFF OFF ON ON - ON OFF #4, #2 - #2
2 #
35V 180x #5,#6
COM(-) ,3-wire(+)
Yokogawa C-1/1A/2/3 AC synchronous OFF OFF OFF OFF OFF OFF OFF OFF OFF ON OFF #1, #2 #2 #1
1 #
Navtec A-55, B-55 50/60Hz #2,#3
(Pla th Rotor voltage: 50/60V
type) Stator voltage: 22V
360x
CMZ-700 DC step ON OFF OFF ON OFF OFF ON ON - ON OFF Remo- #2 -
24V 180x
COM(+), 3-wire(-)
ve * *
CMZ-250X/ DC synchronous 360x OFF OFF OFF OFF OFF OFF ON ON - ON OFF Remo- #2 -
300X/500 ve * *
DC step ON OFF OFF ON OFF OFF ON ON - ON OFF #4, #2 - #2 #2
35V 180x #5,#6
COM(+),3-wire(-)
CMZ-100/200/ AC synchronous OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF #1, #1 #1 #1 #1
300 50/60Hz #2,#3
C-1Jr,D-1Z/1/3 Rotor voltage: 100V
IPS-2/3 Stator voltage: 90V
360x
CMZ-50 step ON OFF OFF ON OFF OFF ON ON - ON OFF Remo- #2 -
35V 180x
See note below. COM(+),3-wire(-)
ve * *
Plath NAVGAT II/III AC synchronous OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF #1, #2 #2 #1 #1
50/60Hz #2,#3
Rotor voltage: 50/60V
Stator voltage: 68V
360x
Tokimec ES-1/2/11 AC synchronous ON ON OFF OFF OFF OFF OFF OFF OFF OFF OFF #1, #1 #1 #1 #1
(Sperry GLT-101/102/ 50/60Hz #2,#3
type) 103/106K/107 Rotor voltage: 100/110V
Stator voltage: 90V
36x
ES-11A/110 AC synchronous OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF #1, #1 #1 #1 #1
TG-200 50/60Hz #2,#3
PR222R/2000 Rotor voltage: 100/110V
PR237L/H Stator voltage: 22V
GM 21 90x
MK-14 DC step ON OFF OFF ON OFF OFF ON ON - OFF OFF #4, #2 - #1 #1
MOD-1/2/T 70V 180x #5,#6
NK-EN,NK-EI COM(-), 3-wire(+)
SR-130/140 DC step ON OFF OFF OFF ON OFF OFF OFF - OFF OFF #4, #2 - #1 #1
70V 180x #5,#6
5-wire, open collector
TG-100/5000 DC step ON OFF OFF ON OFF OFF ON ON - OFF OFF #4, #2 - #1 #1
PR-357/130/ 70V 180x #5,#6
140, ES-17 COM(+), 3-wire(-)
GLT-201/202
/203
TG-6000 DC step ON OFF OFF ON OFF OFF ON ON - ON OFF #4, #2 - #2 #2
24V 180x #5,#6
GM-11 AC synchronous OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF #1, #1 #1 #1 #1
50/60Hz #2,#3
Rotor voltage: 100V
Stator voltage: 90V
90x
SR-120,ES-16 DC step ON OFF OFF ON OFF OFF ON ON - ON OFF #4, #2 - #2 #2
MK-10/20/30 35V 180x #5,#6
Kawasaki GX-81 AC synchronous OFF ON OFF OFF OFF OFF OFF OFF OFF OFF OFF #1, #1 #1 #1 #1
50/60Hz #2,#3
Rotor voltage: 100/110V
Stator voltage: 90V
90x
Armabrown MK-10,MKL-1 DC step ON OFF OFF ON OFF OFF ON ON - OFF OFF #4, #2 - #1 #1
SERIES1351, 50V 180x #5,#6
MOD-4 COM(+), 3-wire(-)
Robertson SKR-80 DC step ON OFF OFF ON OFF OFF ON ON - ON OFF #4, #2 - #2 #2
35V 180x #5,#6
COM(-), 3-wire(+)
*: Set JP4 and JP5 according to the voltage of the external power supply.
4-7
Location of DIP switches, jumper wires on the GYRO CONVERTER board
JP5, JP4
(Supply voltage)
JP2
(Stator voltage)
JP3
(Rotor voltage)
SW3
64P1106 DIP switch
JP1 J12
(Gyro type) (Data output
port #6)
J11
(Data output
port #5)
J10
(Data output
port #4)
SW2
DIP switch
JP6, JP7
(AD format
Fuse SW1 data Tx interval)
(2A) J4 J9
DIP switch
(Stator signal input) (Data output port #3)
J5 J6 J8
(Rotor signal input, (IEC-61162-1 output port) (Data output port #2)
external power input) J7
(Data output port #1)
4-8
Setting the heading readout on the radar display
Confirm that the gyrocompass is giving a reliable readout. Then, set the heading readout on the
radar display with the gyrocompass readout as follows:
1. Right-click the HDG box at the top right corner on the screen.
[HDG MENU]
1 HDG SOURCE
AD-10/SERIAL
2 GC-10 SETTING
000.0
HDG menu
2. Spin the thumbwheel to choose 1 HDG SOURCE and push the left button.
3. Spin the thumbwheel to choose AD-10 and push the left button.
4. Spin the thumbwheel to choose 2 GC-10 SETTING and push the left button.
5. Spin the thumbwheel to set gyrocompass reading and push the left button.
6. Push the right button close the menu.
4-9
4.2 Memory Card Interface Unit
Mounting considerations
When selecting a mounting location, observe the following points:
• Locate the unit away from heat sources because of heat that can build up inside the cabinet.
• Locate the unit away from places subject to water splash and rain.
• Leave sufficient space at the sides and rear of the unit to facilitate maintenance.
• A magnetic compass will be affected if the unit is placed too close to the magnetic compass.
Observe the compass safe distances on page ii to prevent interference to a magnetic compass.
Mounting procedure
Flush mounting
This unit can be flush-mounted in a panel with the standard installation materials.
1. Prepare a cutout in the mounting location, referring to the outline drawing at the end of this
manual.
2. Screw in the threaded rods to the flange on the front panel of the unit securely by hands.
3. Set the unit to the cutout.
4. Insert the flat washer, spring washer and nut in that order for each rod and fasten the nuts.
4-10
Desktop mount
Requires the optional desktop mount kit FP03-10201. Refer to the packing list at the back of this
manual for further information about this kit.
1. Fix the mounting bracket 19-023-3081 to the unit with four screws.
2. Mount the above assembly on a desktop with four self-tapping screws.
Connections
One memory card IF unit and one processor unit
Connect as shown below.
12 VDC
Memory card IF unit
Processor unit MJ-A3SPF0015-100 (10 m)
J614 12 VDC
two mini-cards
PSE-4PTX-BL (10 m)
NETWORK NETWORK
RJ-45
FR-FTPC-CY (10/20/30 m)
(straight)
Switching hub
FR-FTPC-CY
No.2 (10/20/30 m)
Processor (straight)
unit
HUB-100
No.3 (option)
Processor
unit FR-FTPC-CY (10/20/30 m) (straight)
Connecting one memory card interface unit and multiple processor units via switching hub
4-11
it
Armored LAN cable kit
Note: When two memory card interface units are connected via a network, change ID code for the
second unit.
1. Remove the cover and set the IP0 bit of the DIP switch S1 on the CARDCPU board (03P9333)
to ON.
2. Set INIT bit of S1 to ON and turn on the radar. Wait until CR2 starts blinking. DO NOT turn off
the power until CR2 starts blinking.
3. Turn off the power and set INIT bit to OFF.
ON OFF
J314 IP0
IP1
IP2
INIT
S1
CR2
(Default: all OFF)
4-12
4.3 DVI-RGB Conversion Kit
This information provides the procedure necessary for the installation of the DVI-RGB conversion
kit. This kit is installed in the processor unit to enable connection of an RGB monitor or VDR
(Voyage Data Recorder).
See packing list for contents. Refer to the figure below for modification.
DVI-RGB CONVERSION board
M3x8 (SLB-FRN4-A)
6 pcs
DVI cable
J9 J3
(10 pin)
J4
(6 pin)
J615
03-2094
03-2092 03P9342 board
Spring washer
Fixing
holes
Boss
Ferrite core
Clamp copper tape
section by cable clamp.
To external monitor or
BNC connector converter
(see page 4-15).
4-13
1. Remove the top cover and open the upper part of the processor unit.
DVI-D port
(Connect DVI cable at step 12.)
J3
J1 J2
03P9342 board
J615 (Connect connector assembies at step 8.)
4-14
5. Attach the DVI-RGB CONVERSION board to the location shown below.
DVI-RGB
CONVERSION board
J9 J3 (Connect DVI cable at step 9.)
J4
4-15
4.4 BNC Connector Converter
To connect the FURUNO Voyage Data Recorder VR-5000 to this radar, the DVI-RGB conversion
kit (mentioned at previous paragraph) and the BNC connector converter are required. Also VGA
cable (between the processor unit and the BNC connector converter) and five 75 ohm coaxial
cables (between the BNC connector converter and VR-5000) are required.
FAR-2157(-BB) VR-5000
PROCESSOR UNIT VD1 DATA COLLECTING
BNC CONNECTOR 75 W coax. cable
R
UNIT
CONVERTER R
DSUB-BNC-1 G G
B B
VGA cable H HS
DVI-RGB D-sub 15P D-sub 15P
Conversion kit Female V VS
Male
4-16
5. IO DATA
Available input and output data are shown in the tables below and input and output sentences are
shown on the next page.
Note: This radar accepts position data fixed by WGS-84 geodetic datum only. Set the datum to
WGS-84 on the EPFS (GPS, etc.) connected to this radar. If other type of datum is input, the error
message "DATUM" appears and the AIS feature is inoperative.
Input
Data Specifications Contents Remarks
Heading Synchro or step GC-10 required Switching between AD-10
signal and IEC 61162 is done
from menu.
AD-10 format External AD-100
IEC 61162-2
Speed signal IEC 61162-1
Navigator IEC 61162-1 Position, course, speed, LORAN-
data C TD, waypoint, route, time, wind
speed and direction, current data,
depth, water temperature, roll,
pitch, ROT
External Heading, Bearing, No GAIN, STC control Operate as remote display
radar signal Trigger, Video
Alarm ACK Contact closure Input signal from alarm
input signal system
Track Control RS-422 Option
unit
Output
Data Specifications Contents Remarks
Radar system RS-232C RSD, OSD, TLL For PC plotter
data
ARPA data IEC 61162-1 TTM For ECDIS
Remote display Heading, Bearing, Tx 2 ports
signal Trigger, Video
External LCD DVI Same as main monitor unit 2 systems max.
monitor signal
External CRT R, G, B, H, V Same as main monitor unit Option
monitor signal
Alarm signal Contact closure Output to alarm system by using 4 outputs, output
signal photo-relay content selected from
menu.
5-1
IEC 61162 input sentence and priority
Item Sentence and order of priority
Speed (STW) VBW>VHW
Speed (SOG VBW
Speed (position) VTG>RMC
Heading (True) HDT*
Position GGA>GLL>RMC>RMA
Waypoint BWR>BWC>RMB
Date ZDA
Depth DPT>DBT>DBS
Water temperature MTW
Wind MWV
5-2
:0# $':
㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀
0#/' 176.+0' &'5%4+26+10%1&'ͳ 3 6; 0#/' 176.+0' &'5%4+26+10%1&'ͳ 3 6;
࡙࠾࠶࠻ 70+6 ✢᧚ടᎿຠ
A-2
(4
㨻㩧㩍㩏
:0# )4170&+0)9+4'
#06'00#
ዉᵄ▤ߐ߃'ဳ
45$
㩖㨲㨺㩎㩨9)
:0# 9)%.#/2
(''&'49)#55'/$.;
ዉᵄ▤㑆ᐳ
41*5
㨻㩧㩍㩏Ꮏ᧚ #06'00#+056#..#6+10/#6'4+#.5 :0#
9#8')7+&'%.#/2
1㩢㩧㩂㩨 +057.#614
#5
ⷺ㩇㩢㩦㩢㩈㩛㩇$
14+0) /:575
*':*'#&5.16$1.6$
㩃㩚㩆㨺㩣 59㨻㩣㩚㩋㨷㨺㩖㩨)ޓ 9#5*'4
59㨻㩣㩚㩋㨷㨺㩖㩨)
ⷺ㩇㩢㩦㩢ޓ㩘㩨㩣㩎
5+.+%1047$$'4 /:575
*':#)10#.*'#&5.16
㩔㩨㩒ᐳ㊄ $1.6
/575
ⷺ㩇㩢㩦㩢㩘㩨㩣㩎
524+0)9#5*'4 /:575
*':#)10#.*'#&5.16
ࡃࡀᐳ㊄ $1.6
/575
ⷺ㩇㩢㩦㩢㩘㩨㩣㩎
524+0)9#5*'4 /:575
*':#)10#.*'#&5.16
㩚㩀㩨㩁ਣᐔᐳ㊄ $1.6
/575
ⷺ㩏㨹㩎ޓ㩆㨷
(.#69#5*'4 /575
*':076
㩚㩀㩨㩁ਣᐔᐳ㊄
/575
(.#69#5*'4
䍘㪄䍢䍼⇟ภᧃየ䈱㪲㪁㪁㪴䈲䇮ㆬᛯຠ䈱ઍဳᑼ㪆䍘䍎䍢䍼䉕䈚䉁䈜䇯
㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪜㪥㪛㪠㪥㪞㩷㪮㪠㪫㪟㩷㩹㪁㪁㩹㩷㪠㪥㪛㪠㪚㪘㪫㪜㪪㩷㪫㪟㪜㩷㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪦㪝㩷㪩㪜㪧㪩㪜㪪㪜㪥㪫㪘㪫㪠㪭㪜㩷㪤㪘㪫㪜㪩㪠㪘㪣㪅
ဳᑼ䎒䱤䱚䱮䲈⇟ภ䬛䯾Ბ䬽႐ว䫺ਅᲑ䭗䭙Ბ䬺ઍ䭞䭚ㆊᷰᦼຠ䬶䬑䭙䫺䬸䬰䭘䬚䬛䬲䬵䬓䭍䬨䫻䫹䬹䬙䫺ຠ⾰䬾ᄌ䭞䭙䭍䬪䭢䫻
䯴⇛࿑䬽ኸᴺ䬾䫺ෳ⠨୯䬶䬨䫻䎃䎧䎬䎰䎨䎱䎶䎬䎲䎱䎶䎃䎬䎱䎃䎧䎵䎤䎺䎬䎱䎪䎃䎩䎲䎵䎃䎵䎨䎩䎨䎵䎨䎱䎦䎨䎃䎲䎱䎯䎼䎑䯵 䎷䎺䎲䎃䎷䎼䎳䎨䎶䎃䎤䎱䎧䎃䎦䎲䎧䎨䎶䎃䎰䎤䎼䎃䎥䎨䎃䎯䎬䎶䎷䎨䎧䎃䎩䎲䎵䎃䎤䎱䎃䎬䎷䎨䎰䎑䎃䎃䎷䎫䎨䎃䎯䎲䎺䎨䎵䎃䎳䎵䎲䎧䎸䎦䎷䎃䎰䎤䎼䎃䎥䎨䎃䎶䎫䎬䎳䎳䎨䎧䎃䎬䎱䎃䎳䎯䎤䎦䎨䎃䎲䎩䎃
䎷䎫䎨䎃䎸䎳䎳䎨䎵䎃䎳䎵䎲䎧䎸䎦䎷䎑䎃䎴䎸䎤䎯䎬䎷䎼䎃䎬䎶䎃䎷䎫䎨䎃䎶䎤䎰䎨䎑 $':
A-1
1/1
Q'TY
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER
1
03GX-X-9851
03GX-X-9851 -0
**
DESCRIPTION/CODE №
000-090-655-00
008-424-380-00
008-572-970-00
CODE NUMBER ENDING WITH "**" INDICATES THE CODE NUMBER OF REPRESENTATIVE MATERIAL.
SP03-09203
CP03-31301
O U T L I N E
INSTALLATION MATERIALS
コ-ド番号末尾の[**]は、選択品の代表コー ドを表します。
RSB-106-083-S/RSB-107-083-S
PACKING
SPARE PARTS
UNIT
SPARE PARTS
工事材料
ユニット
予備品
工事材料
予備品
)::
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6
A-4
)::
↪ㅜ㧛⠨
4'/#4-5
㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰
3 6;
ᢙ㊂
㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
%2
41*5
41*5
&'5%4+26+105
ဳฬ㧛ⷙᩰ
/:575
(8 .(
/575
/575
/575
/575
%1&'01
%1&'01
%1&'01
%1&'01
%1&'01
%1&'01
%1&'01
%1&'01
%1&'01
%1&'01
%1&'01
(8
6;2'
⇛ޓޓ࿑
176.+0'
#06+%14415+1047$$'4
+056#..#6+10/#6'4+#.5
*':#)10*'#&5%4'9
Ꮏ᧚ᢱ
6'4/+0#.12'0'4
ฬޓޓ⒓
ⷺ㩘㩨㩣㩎ో㩒㩆㩨
524+0)9#5*'4
*':#)10#.076
*':#)10#.076
0#/'
37#.+6;+56*'5#/'
%4+/210.7)
%4+/210.7)
㩚㩀㩨㩁㩙㩣ᐔᐳ㊄
5'#.9#5*'4
(.#69#5*'4
ⷺ㩏㨹㩎㩆㨷
ⷺ㩏㨹㩎㩆㨷
㒐ⲁࠧࡓ
㩆㨺㩣㩦㨹㩆㨶㨺
ᠲ㩤㩔㩨㨺
⌕┵ሶ
⌕┵ሶ
㩔㩨㩒ᐳ㊄
⇟ภ
01
:0# $':
㧼㧭㧯㧷㧵㧺㧳ޓ㧸㧵㧿㨀
0#/' 176.+0' &'5%4+26+10%1&'ͳ 3 6; 0#/' 176.+0' &'5%4+26+10%1&'ͳ 3 6;
࡙࠾࠶࠻ 70+6 ዉᵄ▤ߐ߃'ဳ
A-3
45$
㨻㩧㩍㩏
:0# 9)%.#/2
#06'00#
ዉᵄ▤㑆ᐳ
41*5
㩖㨲㨺㩎㩨9)
:0# 9#8')7+&'%.#/2
+057.#614
(''&'49$#55'/$.;
ⷺ㩇㩢㩦㩢㩈㩛㩇$
/:575
㨻㩧㩍㩏Ꮏ᧚ #06'00#+056#..#6+10/#6'4+#.5
*':*'#&5.16$1.6$
1㩢㩧㩂㩨 9#5*'4
#5
ⷺ㩇㩢㩦㩢ޓ㩘㩨㩣㩎
14+0) /:575
*':#)10#.*'#&5.16
㩃㩚㩆㨺㩣 59㨻㩣㩚㩋㨷㨺㩖㩨)ޓ $1.6
59㨻㩣㩚㩋㨷㨺㩖㩨)
ⷺ㩇㩢㩦㩢㩘㩨㩣㩎
5+.+%1047$$'4 /:575
*':#)10#.*'#&5.16
㩔㩨㩒ᐳ㊄ $1.6
/575
ⷺ㩇㩢㩦㩢㩘㩨㩣㩎
524+0)9#5*'4 /:575
*':#)10#.*'#&5.16
ࡃࡀᐳ㊄ $1.6
/575
ⷺ㩏㨹㩎ޓ㩆㨷
524+0)9#5*'4 /575
*':076
㩚㩀㩨㩁ਣᐔᐳ㊄
/575
(.#69#5*'4
㩚㩀㩨㩁ਣᐔᐳ㊄
/575
(.#69#5*'4
䍘㪄䍢䍼⇟ภᧃየ䈱㪲㪁㪁㪴䈲䇮ㆬᛯຠ䈱ઍဳᑼ㪆䍘䍎䍢䍼䉕䈚䉁䈜䇯
㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪜㪥㪛㪠㪥㪞㩷㪮㪠㪫㪟㩷㩹㪁㪁㩹㩷㪠㪥㪛㪠㪚㪘㪫㪜㪪㩷㪫㪟㪜㩷㪚㪦㪛㪜㩷㪥㪬㪤㪙㪜㪩㩷㪦㪝㩷㪩㪜㪧㪩㪜㪪㪜㪥㪫㪘㪫㪠㪭㪜㩷㪤㪘㪫㪜㪩㪠㪘㪣㪅
ဳᑼ䎒䱤䱚䱮䲈⇟ภ䬛䯾Ბ䬽႐ว䫺ਅᲑ䭗䭙Ბ䬺ઍ䭞䭚ㆊᷰᦼຠ䬶䬑䭙䫺䬸䬰䭘䬚䬛䬲䬵䬓䭍䬨䫻䫹䬹䬙䫺ຠ⾰䬾ᄌ䭞䭙䭍䬪䭢䫻
䯴⇛࿑䬽ኸᴺ䬾䫺ෳ⠨୯䬶䬨䫻䎃䎧䎬䎰䎨䎱䎶䎬䎲䎱䎶䎃䎬䎱䎃䎧䎵䎤䎺䎬䎱䎪䎃䎩䎲䎵䎃䎵䎨䎩䎨䎵䎨䎱䎦䎨䎃䎲䎱䎯䎼䎑䯵 䎷䎺䎲䎃䎷䎼䎳䎨䎶䎃䎤䎱䎧䎃䎦䎲䎧䎨䎶䎃䎰䎤䎼䎃䎥䎨䎃䎯䎬䎶䎷䎨䎧䎃䎩䎲䎵䎃䎤䎱䎃䎬䎷䎨䎰䎑䎃䎃䎷䎫䎨䎃䎯䎲䎺䎨䎵䎃䎳䎵䎲䎧䎸䎦䎷䎃䎰䎤䎼䎃䎥䎨䎃䎶䎫䎬䎳䎳䎨䎧䎃䎬䎱䎃䎳䎯䎤䎦䎨䎃䎲䎩䎃
䎷䎫䎨䎃䎸䎳䎳䎨䎵䎃䎳䎵䎲䎧䎸䎦䎷䎑䎃䎴䎸䎤䎯䎬䎷䎼䎃䎬䎶䎃䎷䎫䎨䎃䎶䎤䎰䎨䎑 $':
A-5 A-6
%1&'01 ):: %1&'01 ).:
6;2' %2 6;2'
Ꮏ᧚ᢱ Ꮏ᧚ᢱ
(#4 (%4
+056#..#6+10/#6'4+#.5 +056#..#6+10/#6'4+#.5
⇟ภ ฬޓޓ⒓ ⇛ޓޓ࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛⠨ ⇟ภ ฬޓޓ⒓ ⇛ޓޓ࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛⠨
01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5 01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5
㩔㩨㩒ᐳ㊄ 㩃㨺㩖㩨㩣 % ㆬᛯޓ61$'5'.'%6'&
ޓޓޓޓޓޓޓޓޓޓ
/575 49 / ାภ㩃㨺㩖㩨㩣ޓޓޓޓ
524+0)9#5*'4 %14'%#$.'
5+)0#.%#$.'
%1&'01 %1&'01
㩚㩀㩨㩁ᐔᐳ㊄ 㩃㨺㩖㩨㩣 % ㆬᛯޓ61$'5'.'%6'&
ޓޓޓޓޓޓޓޓޓޓ
/575 49 / ାภ㩃㨺㩖㩨㩣ޓޓޓޓ
(.#69#5*'4 %14'%#$.'
5+)0#.%#$.'
%1&'01 %1&'01
ⷺ㩘㩨㩣㩎 㩃㨺㩖㩨㩣 % ㆬᛯޓ61$'5'.'%6'&
ޓޓޓޓޓޓޓޓޓޓ
/:575 49 / ାภ㩃㨺㩖㩨㩣ޓޓޓޓ
*':#)10#.*'#&$1.6 %14'%#$.'
5+)0#.%#$.'
%1&'01 %1&'01
㩃㨺㩖㩨㩣⚵ຠ 49 㩃㨺㩖㩨㩣 % ㆬᛯޓ61$'5'.'%6'&
ޓޓޓޓޓޓޓޓޓޓ
49 49 / ାภ㩃㨺㩖㩨㩣ޓޓޓޓ
%#$.'#55; %14'%#$.'
5+)0#.%#$.'
%1&'01 %1&'01
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6
37#.+6;+56*'5#/' 37#.+6;+56*'5#/'
㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
㪈㪅䍘䍎䍢䍼ᧃየ䈮㪲㪁㪁㪴䈱ઃ䈇䈢䍳䍤䍍䍢䈲ઍ䈱ဳᑼ㪆䍘䍎䍢䍼䉕␜䈚䈩䈇䉁䈜䇯
㪛㪦㪬㪙㪣㪜㩷㪘㪪㪫㪜㪩㪠㪪㪢㩷㪛㪜㪥㪦㪫㪜㪪㩷㪚㪦㪤㪤㪦㪥㪣㪰㩷㪬㪪㪜㪛㩷㪜㪨㪬㪠㪧㪤㪜㪥㪫㪅
㪉㪅੍ຠ䈲䇮㪘㪚↪㪃㪛㪚↪䈪ㆬᛯ㗿䈇䉁䈜䇯
㪚㪟㪦㪦㪪㪜㩷㪪㪧㪘㪩㪜㩷㪧㪘㪩㪫㪪㩷㪛㪜㪧㪜㪥㪛㪠㪥㪞㩷㪦㪥㩷㪘㪚㩷㪦㪩㩷㪛㪚㩷㪧㪦㪮㪜㪩㪅
/(4 50#/' (74701'.'%64+%%1.6& &9)01 &<:
㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(ޓ144'('4'0%'10.;㧕
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪ
ᄌࠊࠅ߹ߖࠎޕ ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*' 㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷
722'4241&7%637#.+6;+56*'5#/' 㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅
䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩 ).:
A-10
A-9
CODE NO. 008-535-990 03GL-X-9303 -1 1/1
%1&'01 ).:
TYPE SP03-14401 BOX NO. P
6;2' (2
SETS PER
SHIP NO. SPARE PARTS LIST FOR U S E VESSEL
ઃዻຠ
#%%'5514+'5
⇟ภ ฬޓޓ⒓ ⇛ޓޓ࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛⠨
01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5 QUANTITY REMARKS/CODE NO.
DWG. NO.
㩔㩩㩒㩣㩀㩔㩨㨺 ␜ㇱ↪ޓޓޓޓޓ ITEM NAME OF OR WORKING
(ޓ14&+52.#;70+6 NO. PART OUTLINE
41*5 TYPE NO. PER PER SPARE
2#0'.%18'4 SET VES
%1&'01
ヒューズ FGMB 250V 2A 表示部用
PBF FOR DISPLAY UNIT
㩔㩩㩒㩣㩖㨹㩂 41*5 ␜ㇱ↪ޓޓޓޓޓ 2
1 FUSE
(ޓ14&+52.#;70+6 FGMB 2A 250V 000-157-497-10
2#0'.*11-
000-122-000-00
%1&'01
㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨ޓ㩆㨷 ␜ㇱ↪ޓޓޓޓޓ
(ޓ14&+52.#;70+6
:575
5'.(6#22+0)5%4'9
%1&'01
CODE NO. 008-535-910 03GL-X-9305 -1 1/1 CODE NO. 008-535-920-00 03GL-X-9306 -1 1/1
TYPE SP03-14404 BOX NO. P TYPE SP03-14405 BOX NO. P
SETS PER SETS PER
SHIP NO. SPARE PARTS LIST FOR U S E VESSEL SHIP NO. SPARE PARTS LIST FOR U S E VESSEL
DWG. NO. QUANTITY REMARKS/CODE NO. DWG. NO. QUANTITY REMARKS/CODE NO.
ITEM NAME OF OR WORKING ITEM NAME OF OR WORKING
NO. PART OUTLINE NO. PART OUTLINE
TYPE NO. PER PER SPARE TYPE NO. PER PER SPARE
SET VES SET VES
MFR'S NAME FURUNO ELECTRIC CO.,LTD. DWG NO. 03GL-X-9305 1/1 MFR'S NAME FURUNO ELECTRIC CO.,LTD. DWG NO. 03GL-X-9306 1/1
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変
変わりません。 わりません。
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE
UPPER PRODUCT. QUALITY IS THE SAME. UPPER PRODUCT. QUALITY IS THE SAME.
A-15
03GX-X-9852 -0 1/1
PACKING LIST
A-16
PSU-006
CODE NO. 008-572-750-00 03GX-X-9402 -1
N A M E O U T L I N E DESCRIPTION/CODE № Q'TY TYPE 1/1
CP03-31401
ユニット UNIT
電源制御部 工事材料表
PSU-006-*-* 1
POWER CONTROL UNIT INSTALLATION MATERIALS
000-090-665-00 **
番 号 名 称 略 図 型名/規格 数量 用途/備考
予備品 SPARE PARTS NO. NAME OUTLINE Q'TY
DESCRIPTIONS REMARKS
予備品
圧着端子
SP03-15501 1 FV2-4
1
SPARE PARTS CRIMP-ON LUG 14
(*1) CODE
008-572-730-00 NO. 000-157-247-10
予備品
SP03-15502 1
SPARE PARTS
(*1)
008-572-740-00
工事材料 INSTALLATION MATERIALS
工事材料
CP03-31401 1
INSTALLATION MATERIALS
008-572-750-00
(*1)の予備品は,仕様によりAC100用:SP03-15501,AC220用:SP03-15502.
* 1 : SELECT ONE ACCORDING TO PROCESSOR UNIT'S SPECIFICATIONS : SP03- 15501 FOR 100VAC OR SP03- 15502 FOR 220VAC
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ
ん。
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER
型式/ コー ド番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 PRODUCT. QUALITY IS THE SAME.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER
PRODUCT. QUALITY IS THE SAME. FURUNO ELECTRIC CO .,LTD. 03GX-X-9402
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) 03GX-X-9852
A-17 A-18
CODE NO. 008-572-730-00 03GX-X-9301 -0 1/1 CODE NO. 008-572-740-00 03GX-X-9302 -0 1/1
TYPE SP03-15501 BOX NO. P TYPE SP03-15502 BOX NO. P
SETS PER SETS PER
SHIP NO. SPARE PARTS LIST FOR U S E VESSEL SHIP NO. SPARE PARTS LIST FOR U S E VESSEL
POWER CONTROL UNIT POWER CONTROL UNIT
AC100V AC220V
PSU-006 PSU-006
DWG. NO. QUANTITY REMARKS/CODE NO. DWG. NO. QUANTITY REMARKS/CODE NO.
ITEM NAME OF OR WORKING ITEM NAME OF OR WORKING
NO. PART OUTLINE NO. PART OUTLINE
TYPE NO. PER PER SPARE TYPE NO. PER PER SPARE
SET VES SET VES
ヒューズ ヒューズ
1 FUSE 2 1 FUSE 2
FGBO 250V 5A FGBO 250V 3A
PBF PBF
000-155-840-10 000-155-841-10
MFR'S NAME FURUNO ELECTRIC CO.,LTD. DWG NO. 03GX-X-9301 1/1 MFR'S NAME FURUNO ELECTRIC CO.,LTD. DWG NO. 03GX-X-9302 1/1
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) (略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変 型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変
わりません。 わりません。
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE
UPPER PRODUCT. QUALITY IS THE SAME. UPPER PRODUCT. QUALITY IS THE SAME.
A-19
A-20
工事材料表 付属品表
INSTALLATION MATERIALS ACCESSORIES
番 号 名 称 略 図 型名/規格 数量 用途/備考 番 号 名 称 略 図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
+-ナベセムスB KB直付金具 操作部用
FOR CONTROL UNIT
1 M4X12 C2700W MBNI2 4 1 03-163-7521-1 ROHS
WASHER HEAD SDREW *B* KB FIXING METAL 1
CODE CODE
NO. 000-163-192-10 NO. 100-306-251-10
グロメット 操作部用
FOR CONTROL UNIT
2 G-39
GROMMET 1
CODE
NO. 000-166-401-10
+-ナベセムスB 操作部用
FOR CONTROL UNIT
3 M4X12 C2700W MBNI2
WASHER HEAD SDREW *B* 2
CODE
NO. 000-163-192-10
クリアバンポン 操作部用
FOR CONTROL UNIT
4 TM-180-302
CUSHION 3
CODE
NO. 000-166-468-10
付属品表 付属品表
ACCESSORIES ACCESSORIES
番 号 名 称 略 図 型名/規格 数量 用途/備考 番 号 名 称 略 図 型名/規格 数量 用途/備考
NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS NO. NAME OUTLINE DESCRIPTIONS Q'TY REMARKS
KB直付金具(T) 操作部用 フラッシュマウント金具
FOR CONTROL UNIT
1 03-163-7821-1 ROHS 1 03-163-7531-1 ROHS
KEYBOARD FIXTURE 1 FLUSH MOUNTING PLATE 4
CODE CODE
NO. 100-306-291-10 NO. 100-306-261-10
ブラインドシール 操作部用 +-ナベセムスB
FOR CONTROL UNIT
2 22-020-1005-1 ROHS 2 M4X12 C2700W MBNI2
BLIND SEAL 3 WASHER HEAD SDREW *B* 4
CODE CODE
NO. 100-173-591-10 NO. 000-163-192-10
グロメット 操作部用 六角ナット 1種
FOR CONTROL UNIT
3 G-49 3 M5 SUS304
GROMMET 1 HEX.NUT 4
CODE CODE
NO. 000-166-406-10 NO. 000-165-921-10
+-ナベセムスB 操作部用 蝶ボルト
FOR CONTROL UNIT
4 M4X12 C2700W MBNI2 4 M5X40 SUS304
WASHER HEAD SDREW *B* 2 WING SCREW 4
CODE CODE
NO. 000-163-192-10 NO. 000-162-682-10
クリアバンポン 操作部用
FOR CONTROL UNIT
5 TM-180-302
RUBBER FOOT 2
CODE
NO. 000-166-468-10
ઃዻຠ ઃዻຠ
#%%'5514+'5 #%%'5514+'5
⇟ภ ฬޓޓ⒓ ⇛ޓޓ࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛⠨ ⇟ภ ฬޓޓ⒓ ⇛ޓޓ࿑ ဳฬ㧛ⷙᩰ ᢙ㊂ ↪ㅜ㧛⠨
01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5 01 0#/' 176.+0' &'5%4+26+105 3 6; 4'/#4-5
㩔㩧㩀㩨㨺. 41*5 ขᚻ
41*5
*#0)'4. *#0&.'
%1&'01 %1&'
01
㩔㩧㩀㩨㨺4 41*5 㩥㨺㩈㩨㨹㩎ᐳ㊄ /%9㩘㩩㩢㩆㨺㩣
/%9㩘㩩㩢㩆㨺㩣
*#0)'44 415'66'9#5*'4
%1&'01 %1&'
01
㩔㩧㩀㩨㨺㩅㩅㨾 ਣ⋁ዊ㩒㩆㩨
41*5 /:%9㩘㩩㩢㩆㨺㩣
*#0)'456#; 18#.*'#&5%4'9
%1&'01 %1&'
01
㩘㨺㩣㩖㩩㩡㩂㩨 ᵄᐳ㊄
%2*2 99575
*1.'2.7) 9#8'9#5*'4
%1&'01 %1&'
01
㩇㩏㨹㩖㩩㩘㩨㩊㩧
-$㩠㨽ޓ㩘㩨㩊㩧㩂㩥
50#2$76610
%1&'01
㩚㩀㩨㩁ᐔᐳ㊄
/575
(.#69#5*'4
%1&'01
㩔㩨㩒ᐳ㊄
/575ޓ
524+0)9#5*'4
%1&'01
ⷺ㩇㩢㩦㩢ޓ㩘㩨㩣㩎
/:575
*':$1.6
%1&'01
ⷺ㩇㩢㩦㩢㩈㩛㩇$
/:575
*':$1.6
5.166'&9#5*'4*'#& %1&'01
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖࠎޕ ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖ
ࠎޕ
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4241&7%6 6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4
37#.+6;+56*'5#/' 241&7%637#.+6;+56*'5#/'
㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕 㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
ဳᑼ㩄㨺㩎㩨⇟ภ߇㧞Ბߩ႐วޔਅᲑࠃࠅᲑߦઍࠊࠆㆊᷰᦼຠߢࠅޔ߅ߥޓޕߔ߹ߡߞ߇߆ࠄߜߤޔຠ⾰ߪᄌࠊࠅ߹ߖ
ࠎޕ
6916;2'5#0&%1&'5/#;$'.+56'&(14#0+6'/6*'.19'4241&7%6/#;$'5*+22'&+02.#%'1(6*'722'4
型式/ コー ド番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりません。 241&7%637#.+6;+56*'5#/'
㧔⇛࿑ߩኸᴺߪޔෳ⠨୯ߢߔ&ޓޕ+/'05+105+0&4#9+0)(144'('4'0%'10.;㧕
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER
PRODUCT. QUALITY IS THE SAME. 㧲㨁㧾㨁㧺㧻ޓ㧱㧸㧱㧯㨀㧾㧵㧯ޓ㧯㧻ޓ㧚㧘㧸㨀㧰 )1:
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) 03GO-X-9855
GC-10-2 03GL-X-9852 -4 1/1
PACKING LIST
A-28
(略図の寸法は、参考値です。DIMENSIONS IN DRAWING FOR REFERENCE ONLY.) TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE
UPPER PRODUCT. QUALITY IS THE SAME. 03GL-X-9852
03GO-X-9502
A-27
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ
1/1
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER
用途/備考
03GO-X-9502 -3
REMARKS
Option
.,LTD.
Q'TY
数量
100-316-250-10
000-162-608-10
000-163-167-10
FP03-10201
CO
M4X10 C2700W MBNI2
DESCRIPTIONS
型名/規格
19-023-3081-0
ELECTRIC
5X20 SUS304
For CU-200 Desktop mount kit
CODE NO.
CODE
CODE
CODE
NO.
NO.
NO.
TYPE
FURUNO
図
OUTLINE
略
(略図の寸法は、参考値です。
PRODUCT. QUALITY IS THE SAME.
SELF-TAPPING SCREW
NAME
+トラスタッピンネジ
+-ナベセムスA
名
ACCESSORIES
ハンガー
番 号
NO.
ん。
A-29 A-30
型式/コード番号が2段の場合、下段より上段に代わる過渡期品であり、どちらかが入っています。 なお、品質は変わりませ
ん。
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER
ဳᑼ㪆䍘䍎䍢䍼⇟ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ⾰䈲ᄌ䉒䉍䉁䈞䉖䇯 PRODUCT. QUALITY IS THE SAME.
(略図の寸法は、参考値です。 DIMENSIONS IN DRAWING FOR REFERENCE ONLY.)
㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷
㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅 FURUNO ELECTRIC CO .,LTD. 03GL-X-9407
䋨⇛࿑䈱ኸᴺ䈲䇮ෳ⠨୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩 ).:
D-1
D-2
D-3
注記
440VAC,1φ,50-60Hz RU-1803 *2
*6 TB1
100-115/220-230VAC,1φ,50/60Hz DPYC-2.5 *1
1
*6 DPYC-2.5 *1 2 TB3
100/110/115/220/230VAC,1φ,50/60Hz RU-3423 *2
TB2 24V+/U 1 アカ RED
PSU-006
DPYC-4 *1
24VDC 24V-/V 2 シロ WHT
*6 or W 3 クロ BLK
200VAC,3φ,50Hz TPYC-2.5 *1
*2)オプション。
*1)造船所手配。
1 U/24V+
220VAC,3φ,60Hz 2 V/24V- TX_HV 6 アカ RED
*6 TPYC-2.5 *1
1
GND 13
POWER UNIT ANT_ON 12
電源制御部 +12V 11
GND 9 クロ BLK TB901
TB3
PE
*6 TPYC-2.5 *1 TPYCY-2.5,MAX.100m 1 U/24V+
220VAC,3φ,50Hz RU-6522 *2
2 V/24V-
IV-8sq.
*6 TPYC-2.5 *1 3 W
BLK
WHT
RED
440VAC,3φ,50Hz RU-5466-1 *2 *1
*1 *4
保護アース
空中線部
TPYC-1.5,MAX.100m *1
TPYCY-1.5,MAX.100m
*5)FAR-2157-BBのときは支給なし。
RSB-106/107
6 TX_HV
ANTENNA UNIT
8 TX_SIG
9 GND
J1 J603(XH)
PE
6 GND
J621
J604
9 03-2088(6-14P) 1 GC_LED
1 +12V
*3
10 2 GC_HOLD
BOARD
RW-9600,15/30/40/50m,φ22
RW-4747
IV-8sq.
2 ANT_ON_N
03-2090(3P) J5(VH) 11 3 GC_UP J610 TB801
*1 *4
保護アース
1 GYRO_R2 12 4 GC_DOWN 24V_PLUS 1 ダイ(太) ORG[B] 1 24V_PLUS
J680 2 GYRO_R1 13 5 GC_0V 24V_MINUS 2 キ(太) YEL[B] 2 24V_MINUS
64P1106A *2
MPYC-7 *1
GYROCOMPASS 1 チャ BRN 3 NC 14 6 GC_5V MOTOR(+) 3
*6)交流は両極切りブレーカ(造船所手配)を経由すること。
*4)保護アース用ケーブルは緑/黄の絶縁線を使用のこと。
3 ダイ ORG 1 GYRO_S1 DATA1-H 1 チャ BRN 1 AD_DATA-H MOTOR(-) 5
P
4 キ YEL 2 GYRO_S2 DATA1-C 2 アカ RED 2 AD_DATA-C MOTOR(-) 6
5 ミドリ GRN 3 GYRO_S3 SHIFT1-H 3 ダイ ORG 3 AD_CLK-H SPU_RF_D-A 7 アカ RED 3 SPU_RF_D-A
P
6 アオ BLU 4 GYRO_T SHIFT1-C 4 キ YEL 4 AD_CLK-C SPU_RF_D-B 8 ミドリ GRN 4 SPU_RF_D-B
7 ムラサキ PPL 5 GYRO_FG FG 5 RF_SPU_D-A 9 クロ BLK 5 RF_SPU_D-A
03-2089(5P) RF_SPU_D-B 10 シロ WHT 6 RF_SPU_D-B
SG 11 ミドリ(太) GRN[B] 7 SG
TTYCS-4 *1
GND 12 アカ(太) RED[B] 8 GND
NOTES
A-D CONVERTER
2
J609 TB802
IF_VIDEO IF_VIDEO
03P9342
GND GND
*2: OPTION.
TB BOARD
J2 J1 J9 J3
VGA CABLE *1 1 R_VIDEO R_VIDEO 1 5 R 1
RGB EXT. MONITOR 合計:31.5m以下 TOTAL: UP TO 31.5m
2 G_VIDEO GND 2 6 GND 2
3 B_VIDEO G_VIDEO 3 7 G *2
XH10P-W-6P XH10P-W-5P-A
SLB-FRN4-A
COAX.(75Ω)x5 6 GND GND 6 10 GND
VDR J602 J501/J521 J502/J522 J501
CONVERTER
7 GND H_SYNC 7 3 HS KEY_TXD-B 1 1 KEY_TXD-B KEY_TXD-B 1 1 KEY_TXD-B
03P9229A
DVI-RGB変換基板
8 GND GND 8 4 GND KEY_TXD-A 2 2 KEY_TXD-A KEY_TXD-A 2 2 KEY_TXD-A
DSUB-BNC-1 *2
BNC CONNECTOR
BNCコネクタコンバータ
9 NC V_SYNC 9 1 VS 23 KEY_RXD-B 3 3 KEY_RXD-B KEY_RXD-B 3 3 KEY_RXD-B
10 GND GND 10 2 GND 24 KEY_RXD-A 4 4 KEY_RXD-A KEY_RXD-A 4 4 KEY_RXD-A
IV-8sq.
操作部
15 NC SYS_FAIL-H 9 9 SYS_FAIL-H NC 9 9 NC
NC
NC
GND
GND
+12V
+12V
-5/-12V
GND
VCC
PE *1 *4
保護アース
J3
J4
*6 SYS_FAIL-C 10 10 SYS_FAIL-C NC 10 10 NC
440VAC DPYC-1.5 *1 6
5
4
3
2
1
RCU-016 *2
3
2
1
DVI-RGB-1 *2
J507/J527
RGBビデオコンバータ
CONTROL UNIT
1φ,50-60Hz
トランス
RGB VIDEO CONVERTER
1 SYS_FAIL-H
RU-1803 *2
2 SYS_FAIL-C
操作部
TRANSFORMER
*6 J615 J622
100-120/ TB1 チャ BRN 1 +12V SYS_ACK-H 1 3 SYS_ACK-H
DPYC-2.5 *1 2 2
200-230VAC 1 H アカ RED GND SYS_ACK-C 4 SYS_ACK-C
RCU-014/015
3
2 C ダイ ORG 3 +5V
CONTROL UNIT
1φ,50-60Hz
キ YEL 4
TXD 3
ANT. TYPE
NC 4
RS-232C CABLE *1
DVI-D MONITOR GND 5 PC
TB1
22
22
18
*6 J3 J204 NC 6
RS-232C
DPYC-2.5 *1
*1
24VDC
NC 5 5 NC J605
5/10m,φ7
制御部
DDC_CLOCK 6 6 NC HDG-A 1
P
表示部
TMDS_DATA(-) 9 9 DVI0TX1_N
PROCESSOR UNIT
MONITOR UNIT
MU-201CR *5
*1
220VAC,3φ,60Hz
200VAC,3φ,50Hz
P NAVIGATOR
NC 12 12 NC NAV-B 2 (IEC-61162-1)
NC 13 13 NC NC 3
+5V_POWER 14 14 VCC
GND 15 15 GND J607 *1
16 16 LOG-A 1 TTYCS-1
HOT_PLUG_DETECT NC
P
SPEED LOG
TMDS_DATAB(-) 17 17 DVI0TXD_N LOG-B 2 (IEC-61162-1)
4
TMDS_DATAB(+) 18 18 DVI0TXD_P NC 3
TMDS_DATA0/5_SHIELD 19 19 A_GND
NC 20 20 NC J619 *1
21 21 ARPA-A 1 TTYCS-1
NC NC ECDIS
PE
P
TMDS_CLOCK_SHIELD 22 22 A_GND ARPA-B 2 (IEC-61162-1)
TMDS_CLOCK(+) 23 23 DVI0TXC_P NC 3
IV-8sq.
TMDS_CLOCK(-) 24 24 DVI0TXC_N
*1
*1 *4
保護アース
J620
TRK_TD-A 1 TTYCS-4
P TRACK_CONTROL
DVI-D MONITOR TRK_TD-B 2
*2 J205 TRK_RD-A 3 (IEC-61162-1)
外部モニター DVI CABLE P
EXT. MONITOR 1 SAME AS AVOBE TRK_RD-B 4
2 GND 5
SCALE
DRAWN
DWG.No.
CHECKED
*1
APPROVED
J611
24 AIS_TD-A 1 TTYCS-4
P AIS
AIS_TD-B 2
(IEC-61162-2)
Feb. 1 '07
AIS_RD-A 3
P
J1 MJ-A3SPF J614 AIS_RD-B 4
MJ-A3SPF0015,10m,φ6
+12V 1 シロ WHT 1 +12V AIS_GND 5
2 2 GND
MASS
GND クロ BLK
CU-200
*1
Maki
FG 3 J612
TTYCS-7
ALARM1_0 1 ALARM SYSTEM
P
Y.Hatai
kg
2 2 ALARM2_1 4
TAKAHASHI.T
TXN TXN
RXP 3 3 RXP ALARM3_0 5
P
防水型カードインターフェイス
NC 4 4 NC ALARM3_1 6
LAN
P
MEMORY CARD I/F UNIT
NC 5 5 NC OPERATOR_FITNESS_0 7
P
RXN 6 6 RXN OPERATOR_FITNESS_1 8
*2
NC 7 7 NC EXT_ALM_ACK_N 9
P
*1
NC 8 8 NC GND 10
IV-1.25sq.
SYS_FAIL-H 11
P
SYS_FAIL-C 12
*1
LAN CABLE(CAT5) OR J616(NH)
GND 1 RW-4864,φ9.5
MPS588-C FR-FTPC-CY,10/20/30m,φ13 MASTER RADAR
TXP 1 シロ/ミドリ WHT/GRN OP_HD_IN 2
P
TXN 2 ミドリ GRN GND 3
RXP 3 シロ/ダイ WHT/ORG OP_BP_IN 4
NC 4 アオ BLU GND 5
P
NC 5 シロ/アオ WHT/BLU OP_TRIG_IN 6
6 ダイ ORG GND 7
スイッチング ハブ
RXN
NC 7 シロ/チャ WHT/BRN OP_VIDEO_IN 8
SWITCHING HUB
NAME
TYPE
名 称
NC 8 チャ BRN
J617(NH)
HUB-100 (8 PORTS)
NR203PF-VVS1.25 RW-4864,φ9.5
*2
GND 5
OP_TRIG_1 6
保護アース PE
GND 7
相互結線図
OP_VIDEO_1 8
IV-1.25sq. *1 *4
J618(NH)
RW-4864,φ9.5
GND 1 SUB DISPLAY2
OP_HD_2 2
FAR-2157/2157-BB
(SEMI-LOG)
MARINE RADAR/ARPA
GND 3
OP_BP_2 4
船舶用レーダー/ARPA
GND 5
OP_TRIG_2 6
GND 7
INTERCONNECTION DIAGRAM
OP_VIDEO_2 8
S-1