Duration, Manpower

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 6

Maintenance Works at Reserve Medical Store in Nizwa

Civil Works

Sr No. Description

1 Repair of Damaged Flooring

2 Re-application of Epoxy Resin Flooring

3 Floor Marking Lines

Crack Repair on Exposed Ceiling Soffit and


4
Walls

5 Internal Wall Painting at Specified Areas

6 Ceiling Painting at Specified Areas

7 External Wall Painting

8 Replacement of Rubber Bumper

9 Intermediary Metal Beams to Pallet Racks

Replacement of Roof Waterproofing


10
System
Replacement of Roof Waterproofing
11
System

Replacement of Roof Waterproofing


12
System

Replacement of Roof
13
Waterproofing System
Replacement of Roof
14
Waterproofing System
Replacement of Roof Waterproofing
15
System
Replacement of Roof Waterproofing
16
System
Replacement of Roof Waterproofing
17
System
Replacement of Roof Waterproofing
18
System

Replacement of Roof Waterproofing


19
System

Modification of
20
Existing Modular Security Cabins

Modification of Existing Modular Security


21
Cabins

Modification of
22
Existing Modular Security Cabins

Modification of Existing Modular Security


23
Cabins

Modification of Existing Modular


24
Security Cabins

Modification of Existing Modular Security


25
Cabins

Modification of Existing Modular


26
Security Cabins

Modification of Existing Modular Security


27
Cabins

Modification of Existing Modular Security


28
Cabins

Modification of Existing Modular Security


29
Cabins

Modification of Existing Modular Security


30
Cabins
serve Medical Store in Nizwa

Labour
Description Unit Quantity
required
Saw cut to regular shape (squaring) the damaged area of the affected floor slab; Chip-off to
remove damaged concrete surfaces to a maximum depth of 10mm; Smoothen and level the
chipped-off surface by mechanical grinder; Clean thoroughly to remove dirt, dust and other
contaminants; Fill up the chipped-off floor with high quality epoxy screed (supply and
apply) up to the desired level to match with existing; Also include the repair of expansion M2 30 1+1
joints

Scraped-off and remove the existing epoxy resin coating and clean thoroughly; Reinstate
the floor finishing by applying heavy-duty flow applied/self-levelling epoxy resin flooring
(supply and apply) with a minimum thickness of 2mm;
Epoxy resin flooring works shall be re- applied at Medical Store Ground Floor
corridors/passageways (except on areas where pallet racks are fixed) and loading/unloading M2 1000 3+3
platform

Floor marking yellow solid border lines


100mm wide at periphery of pallet racks similar to existing M 420 1+2
Chase the crack using a diamond concrete cutting disk and small angle grinder to open up
in a single cut and to a depth of 5-10mm along the crack; Wire brush, then blow/vacuum
dust and debris from the crack; Clean the substrate of dust, laitance and any form of
contaminants; Fill the gap by applying approved non-shrink high strength epoxy resin LS 1 1+2
sealant (or approved equivalent)

Remove loose paints; clean thoroughly; Apply deep penetrating primer and 2 coats of
semi-gloss emulsion paint of color to match with existing (code 10B15 ivory or approved
equivalent) to internal walls of loading/unloading platform, entrance passage, exit passage
and room for reach truck/fork lift
M2 235 1+2

Clean thoroughly; Apply deep penetrating primer and 2 coats of matt emulsion paint of
color white to exposed ceiling soffit of loading/unloading platform, entrance passage, exit
passage, room for reach truck/fork lift and ceiling crack repair area M2 135 1+2

Remove loose and flaking paints; clean thoroughly; apply deep penetrating primer and 2
coats of weatherproof medium textured paint of color to match with existing (code 83451
or approved equivalent) to all external walls (including of roof parapet walls and duct M2 2400 3+3
houses)

Supply and fix ultra heavy-duty EPDM Rubber Bumper D-shape 152mm depth x152mm
high in 2 layers as wall protection at loading/unloading platform M 50 1+1

Supply and fix heavy-duty intermediary metal beams 2400mm length including fitting
accessories anchored to front and back vertical support of the pallet rack (36Nos) bottom
compartment to serve as an No 72 2+4
additional layer of shelf

Remove the existing waterproofing system (gravel/roof tiles, geotextile membrane,


insulation board, waterproofing membrane) including those on the parapet walls and
upstands; Salvage, set aside and washed the existing concrete tiles and gravel to be reuse
later as a final layer; Repair any cracks with approved non-shrink crack sealant and prepare
the surfaces to receive the new waterproofing system; Cart away M2 1515 2+2
debris from the site
Supply and lay 4mm thick torch applied approved bituminous waterproofing membrane
M2 1425 3+2
Supply and lay solar reflective type bituminous waterproofing membrane to parapet wall
and upstands; Seal the expose end with mastic sealant or approved equivalent M 340 3+2

Thermal insulation 50mm thick high density polystyrene board


M2 1425 3+2
Geotextile membrane as separation layer
M2 1425 3+2
Re-fix the salvaged roof tiles at walkways (remeasurable)
M2 305 2+2
Re-lay the salvaged gravel up to the desired level (remeasurable)
M3 1120 2+2
Provision for new precast concrete tiles of size similar to existing (remeasurable)
M2 60 1+1
Provision for new washed gravel 15 to 20mm diameter (remeasurable)
M3 10 2
At concrete pads: surfaces not covered by the solar reflective waterproofing membrane
shall be cleaned, primed and painted with 3 coats of polyurethane paint or approved
equivalent UV resistant liquid applied waterproofing membrane M2 75 2+1

Demolish existing concrete pad 1800 x 2400 x 200mm thick and cart away debris
No 1 2
Supply and lay imported fill materials to make up levels; Backfill must be done in layers of
not more than 150mm thick and compact properly to 95% MDD and to the approval of the M3 24 2
Engineer

Provision of slope protection by stone


pitching/grouted riprap to the edges of the built-up backfill area M2 16 1+1
Construct reinforced cement concrete pad of size 2400mm W x 6700mm L x 300mm T;
Finishing of exposed surfaces is of granite tiles; include all associated civil works to No 1 2+2
complete

Supply and install kerbstone including base preparation (levelling to desired slope and
compaction) M 6 1+1

Supply and install interlocking pavers 60mm thick including base preparation (levelling to
desired slope and compaction) M2 12 1+1

Shift and re-arrange the existing modular cabins as shown in the drawing
No 2

Supply and install powder coated heavy-duty aluminum door full double-glazed (6mm
thick clear glass each) with all accessories to complete No 1 Supplier
Remove existing fixed window and replace (supply and install) with powder coated
aluminum sliding window double-glazed (6mm thick clear glass each) with all accessories No 2 Supplier
to complete

Supply and install powder coated aluminum sliding window double-glazed (6mm thick
clear glass each) with all accessories to complete No 1 Supplier
Supply and apply UV resistant fiber reinforced liquid applied waterproofing membrane or
approved equivalent to roof of Cabin-2 M2 4 1+1
Duration in
Resources
(Days)

Hilti machine=1,
6 Grinder Machine=1,
Vaccum machine=1

20 Drill machine=1

10 Paddle Drill machine=1

Hilti machine=1,
8 Grinder Machine=1,
Vaccum machine=1

10 Hand Tools

6 Hand Tools

25 Hand Tools

4 Drill machine=1

Hilti machine=1,
Grinder Machine=1,
20
Drill Machine=1&
Welding machine=1

Hilti machine=1,
15
Hand Tools
10 Hand Tools & Cylinder

3 Hand Tools & Cylinder

2 Hand tools

1 Hand tools

6 Hand tools

Boom loader/JCB Hand


3
tools
Boom loader/JCB Hand
2
tools
Boom loader/JCB Hand
2
tools

3 Hand tools

2 Hand Tools

Hand tools &


6
Compactor

3 Hand Tools

Steel Cutter Machine &


7
Hand Tools

1 Hand Tools

1 Hand Tools

Crane

1 Hand Tools

You might also like