Professional Documents
Culture Documents
BNL - A318 _ A319 _ A320 _ A321 - AMM - FSN_ 005 - 01-May-2024 - 21-63-00-920-001-A - Remove and Restore Trim Air Pressure Regulating Valve Filter
BNL - A318 _ A319 _ A320 _ A321 - AMM - FSN_ 005 - 01-May-2024 - 21-63-00-920-001-A - Remove and Restore Trim Air Pressure Regulating Valve Filter
BNL - A318 _ A319 _ A320 _ A321 - AMM - FSN_ 005 - 01-May-2024 - 21-63-00-920-001-A - Remove and Restore Trim Air Pressure Regulating Valve Filter
WARNING: MAKE SURE THAT AIR IS NOT SUPPLIED TO THE AIR CONDITIONING SYSTEM FROM THE MAIN ENGIN
E, THE APU OR A GROUND SOURCE.
HOT COMPRESSED AIR CAN CAUSE INJURY TO PERSONNEL.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S IN
STRUCTIONS AND YOUR LOCAL REGULATIONS.
NOTE: This procedure is not applicable for the trim-air pressure regulating-valve part number for 70853A01000
1.
QT
REFERENCE DESIGNATION
Y
No specific Torque wrench: range to between 0.36 and 0.44 m.daN (31.86 and 3
8.94 lbf.in)
No specific Torque wrench: range to between 0.8 and 0.9 m.daN (70.80 and 79.6
5 lbf.in)
B. Consumable Materials
REFERENCE DESIGNATION
825
REFERENCE DESIGNATION
Ref. 21-63-00-720-001-A Functional Test of the Cockpit and Cabin Temperature Control Withou
t the CFDS/MCDU
Ref. 24-41-00-861-002-A Energize the Aircraft Electrical Circuits from the External Power
Ref. 24-41-00-861-002-A01 Energize the Aircraft Electrical Circuits from the APU
Ref. 24-41-00-861-002-A02 Energize the Aircraft Electrical Circuits from Engine 1(2)
Ref. 24-41-00-862-002-A De-energize the Aircraft Electrical Circuits Supplied from the External
Power
Ref. 24-41-00-862-002-A01 De-energize the Aircraft Electrical Circuits Supplied from the APU
Ref. 24-41-00-862-002-A02 De-energize the Aircraft Electrical Circuits Supplied from the Engine 1
(2)
Ref. 52-30-00-860-001-A Open the Forward or Aft Cargo-Compartment Door With the Yellow El
ectric Pump
Ref. 52-30-00-860-002-A Close the FWD or Aft Cargo-Compartment Door with the Yellow Electr
ic Pump
3. Job Set-up
SUBTASK 21-63-00-861-065-A
A. Energize the aircraft electrical circuits
Ref. AMM TASK 24-41-00-861-002.
SUBTASK 21-63-00-865-076-A
B. Open, safety and tag the circuit breaker(s) that follow(s). Use the SAFETY CLIP - CIRCUIT BREAKER as nec
essary.
SUBTASK 21-63-00-941-061-A
D. Safety Precautions
(1) In the cockpit, on the overhead panel, on AIR COND panel 30VU make sure that:
- The APU BLEED pushbutton switch is in the OFF position (the ON legend is off)
- The ENG 1 BLEED and ENG 2 BLEED pushbutton switches are in the OFF position (the OFF l
egends are on)
- The PACK 1 and PACK 2 pushbutton switches are in the OFF position (the OFF legends are
on).
(a) Put a WARNING NOTICE(S) in position to tell persons not to operate these pushbutton switc
hes.
(2) On the high pressure (HP) and the low pressure (LP) ground connectors:
(a) Put a WARNING NOTICE(S) in position to tell persons not to supply the ground air.
4. Procedure
** ON A/C FSN 002-050
Ref. Fig. Trim-Air Pressure-Regulating-Valve Filter
** ON A/C FSN 002-050
SUBTASK 21-63-00-920-050-A
A. Removal and Repair of the Trim-Air Pressure-Regulating-Valve Filter
WARNING: USE PROTECTIVE GOGGLES AND GLOVES EACH TIME YOU CUT LOCKWIRE. DISCARD LO
OSE OR USED LOCKWIRE IMMEDIATELY. LOOSE OR USED LOCKWIRE CAN CUT YOU OR
MAKE YOU BLIND.
CAUTION: MAKE SURE THAT THE ELECTRICAL CONNECTORS ARE CLEAN BEFORE YOU DISCONNE
CT OR CONNECT THEM. CONTAMINATION ON THE ELECTRICAL CONNECTORS CAN CA
USE DAMAGE TO EQUIPMENT.
(1) For the trim-air pressure regulating-valve of part number 746A0000-06 and the subsequent part nu
mbers:
(b) Put the CAP - BLANKING on each disconnected electrical connector and receptacle.
(c) Remove and discard the lockwire from the cover (2).
(d) Remove the cover (2) and discard the packing (5).
(e) Remove and discard the filter (3) and the packing (4).
(g) Make sure that the parts retained from the removed component are clean and in the correct
condition.
(h) Put a new IPC-CSN(21-63-52-02 ITEM 080) PACKING (4) in position on the new IPC-CSN(21
-63-52-02 ITEM 010) FILTER (3).
(i) Put the new filter (3) in position on the trim-air pressure regulating-valve.
(j) Put the new IPC-CSN(21-63-52-02 ITEM 090) PACKING (5) in position on the trim-air pressu
re regulating-valve and install the cover (2).
(k) TORQUE the cover (2) to between 0.36 and 0.44 m.daN (31.86 and 38.94 lbf.in).
(l) Safety the cover with the Wire-Locking Dia: 0.5 mm (0.020 inch) CRES Nickel Alloy - (Materi
al Ref. 14QDB1).
(m) Disconnect the sense line connector (9) from the trim-air pressure regulating-valve.
(n) Disconnect the sense line connector (10) from check valve 7270HM.
(o) On the connection of the sense line (8) that connects to the trim-air pressure regulating-valv
e:
- Use the AIR SOURCE - REGULATED, FILTERED, DRY and blow the clean and dry com
pressed air into the sense line (8) to remove contamination or humidity.
(p) Connect the sense line connector (10) to check valve 7270HM.
(r) Disconnect the sense line (11) from check valve 7272HM.
(s) On the connection of the sense line (8) that connects to the trim-air pressure regulating-valv
e:
- Use the AIR SOURCE - REGULATED, FILTERED, DRY and blow the clean and dry com
pressed air into the sense line (8) to remove contamination or humidity.
(t) Connect the sense line connector (11) to check valve 7272HM.
(v) Connect the sense line connector (9) to the trim-air pressure regulating-valve.
(x) Remove the CAP - BLANKING from each electrical connector and receptacle.
(y) Make sure that all the electrical connections are clean and in the correct condition.
(b) Put the CAP - BLANKING on each disconnected electrical connector and receptacle.
(c) Disconnect the sense line connector (9) from the filter (6).
(d) Remove the filter (6) and discard the packing (7).
(h) Put a new IPC-CSN(21-63-52-02 ITEM 020) PACKING (7) on the filter (6).
(j) TORQUE the filter (6) to between 0.8 and 0.9 m.daN (70.80 and 79.65 lbf.in).
(k) Disconnect the sense line connector (10) from check valve 7270HM.
(l) On the connection of the sense line (8) that connects to the trim-air pressure regulating-valv
e:
- Use the AIR SOURCE - REGULATED, FILTERED, DRY and blow the clean and dry com
pressed air into the sense line (8) to remove contamination or humidity.
(m) Connect the sense line connector (10) to check valve 7270HM.
(o) Disconnect the sense line connector (11) from check valve 7272HM.
(p) On the connection of the sense line (8) that connects to the trim-air pressure regulating-valv
e:
- Use the AIR SOURCE - REGULATED, FILTERED, DRY and blow the clean and dry com
pressed air into the sense line (8) to remove contamination or humidity.
(q) Connect the sense line connector (11) to check valve 7272HM.
(s) Connect the sense line connector (9) at the trim-air pressure regulating-valve.
(u) Remove the CAP - BLANKING from each electrical connector and receptacle.
(v) Make sure that all the electrical connections are clean and in the correct condition.
SUBTASK 21-63-00-720-052-A
© AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
REVISION REVISION
CUSTOMIZATION AIRCRAFT TYPES DOCTYPES TITLE
DATE NUMBER
A318 A319 A321 21-63-00-920-001-A - Remove and Restore Trim Air Pressure
BNL AMM 01-May-2024 15
A320 Regulating Valve Filter
TAIL NUMBER - MSN - FSN: 5A-BRE - 04414 - 005
C. Test(s)
(1) Do the pre-conditioning through the HP ground connector or with the APU Ref. AMM TASK 12-33-2
1-618-001 or Ref. AMM TASK 12-33-21-618-001.
(2) Make sure that there are no leaks from the filter connections.
(3) After approximately 15 minutes, stop the pre-conditioning Ref. AMM TASK 12-33-21-618-001 or Re
f. AMM TASK 12-33-21-618-001.
(4) Do the functional test of the cockpit and the cabin temperature control-system Ref. AMM TASK 21-
63-00-720-001
** ON A/C FSN ALL
5. Close-up
** ON A/C FSN 002-050
SUBTASK 21-63-00-410-059-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the access panels at partition FR34 Ref. AMM D/O 06-41-53-00 and Ref. AMM TASK 25-54-1
2-400-001.
(3) Remove the access platform(s).
(4) Close FWD cargo-compartment door 825 Ref. AMM TASK 52-30-00-860-002.
(5) Remove the WARNING NOTICE(S).
** ON A/C FSN ALL
SUBTASK 21-63-00-862-063-A
B. De-energize the aircraft electrical circuits Ref. AMM TASK 24-41-00-862-002.
FR36
14HK
B C
FWD CARGO-COMPARTMENT
DOOR
Z130
FR24A
FR24
FR34
FR35
Z190
N_MM_216300_3_AAN0_01_04
9
8
11
10
B 01
9
8
11
7
10
C 02
NOTE:
01 FOR PART NUMBER 746A0000-06 AND SUBSEQUENT
02 FOR PART NUMBER 746A0000-04/-05 N_MM_216300_3_AAN0_02_01
7270HM
10
10
7272HM
11
11
N_MM_216300_3_AAN0_03_00
N_MM_216300_3_AAN0_04_00