Screen and disc filters are used to remove particulate impurities from water.
Particles in water can cause problems of erosion in pumps and pipe work and can
block fine jets such as spray nozzles. Water flows through a screen or between
discs which retain particles larger than the defined filtration grade. Screen and disc
filters do a similar job to cartridge filters but the screens/discs are cleaned rather
than replaced, so operating costs are minimal.
Options
• Filtration grades (µm): 20, 50, 100,
130, 200, 400
• Backwashing: air aided flushing
(standard), internal or external flushing
• Piping: plastic coated steel,
stainless steel
Berkal™
System Performance
Flow Backwash
Model Connections Width Height Depth
Rates* Air**
°C bar
5-35 0.8-10
5-45 0.8-9
5-55 0.8-8
5-65 0.8-7
5-70 0.8-6.5
*100µm filter
**per filter element at 5-6 bar
(S) S version is with high-grade steel pipe work
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/Berkal™/AQF0021_EN_V1.2
'*"#!"*1'.*,(($#,#'&+'&+-$,0'-*$'$'$#,*'$-,#'&+"&'$'!#+'%(&0,#$+$'.
# %#+((%&$&''*#()&$($"%#,+&'&*(&(($"#(!'+($)(#$(
"#$-
?
)#
"&
"%%+")%'##'"!&"!&('*"(%""'%"('"!&!""&" #!*'&")
B
*$
"7 "7
/%&, ,/6"4& /..&$4*/.3*.$)&3 *%4) &*()4 &04)
2&3352& &-0&2"452&
- )2 "6 *,42"4& #"2 : -- -- --
4. 3 R ¾ R ¾ 16 70 178 449 97
7. 2 R 1 R 1 16 70 209 453 97
7. 8 R 1¼ R 1¼ 16 70 222 453 97
10. 0 R 1½ R 1½ 16 70 246 5 32 120
11. 5 R 2 R 2 16 70 267 532 120
'$!!
# "%$ "!!$ $!!!! &!" !&!
/2)*()&29/62"4&"00,*$"4*/.3$/.35,48/52,/$",&/,*" "4&2/,54*/.3&$)./,/(*&3$/-0".8%&4"*,3#&,/6
Granular Media
Granular Media Pressure Filtration
Filtration
Pressure
Granular media is contained within a pressure vessel, typically GRP or coated
steel. Water enters the top of the vessel and flows downwards through the bed of
media, exiting through a collector system at the base. Contaminants are removed
by straining and/or adsorption depending on the chosen media. The filters must be
periodically backwashed.
Depending on the type of filter media used, granular media filtration has a variety of
applications including:
Filtration of water after chemical dosing to remove colloidal haze and turbidity
Pre-filtration to protect membrane processes from fouling
Filtration of cooling water to prevent heat exchanger fouling
Filtration of borehole water to remove iron and manganese
Removal of chlorine from water to protect ion exchange resins or membranes
Increasing the pH of acidic water to prevent corrosion
Feed water for drip irrigation systems
Sand is used to remove particulates and suspended solids. For high suspended solids
loads, a layer of coarse anthracite may be added above the sand. Multimedia filtration
may also be used for very fine filtration by adding a layer of fine garnet below the sand.
Sometimes two stages of filtration are used –often anthracite and sand in the first
vessel with sand and garnet in the second. This allows chemicals like polyelectrolytes
to be added between the stages to improve filtration efficiency.
Granular activated carbon is widely used to remove chlorine from water prior to ion
exchange or reverse osmosis where it could damage the resins or membranes.
Dechlorination by activated carbon also removes the taste associated with chlorine.
Activated carbon is also used to remove a wide range of organic chemicals including
chlorinated hydrocarbons, pesticides and the species that cause taste, odour and co-
lour.
Manganese dioxide is used as a catalytic filter bed to remove iron and manganese
from borehole water for a range of industrial applications.
*-$%#$!-4*1-/!++'%/%*).*).0'/3*0-'*'!*'%/!-*'0/%*).!$)*'*#%!.*(+)3 !/%'.!'*1
;>,4F;*7>5*;
.-2*";.<<>;.
25=.;<
$*70.
0+'!2
H
H
H
H
G
G
58@;*=.<*;.-.9.7-*7=87/..-@*=.;:>*52=B*7-6.-2*<.5.,=287
>=86*=2,*2;?.7=< *7>*5*2;?.7=<
+!-/%*)
2%(0(*+!-/%)#+-!..0-! +*;
2%(0(*+!-/%)#/!(+!-/0-! I
+/%*).
σ182,.8/1201:>*52=B6.-2*
σ *7>*58;*>=86*=2,*2;?.7=<
σ2;273.,=287<B<=.6,869;.<<8;273.,=8;,87=;859*7.5
*-$%#$!-6*1-/!++'%/%*).*).0'/3*0-'*'!*'%/!-*'0/%*).!$)*'*#%!.*(+)3 !/%'.!'*1
<?-5G<+8?6+<
/.3+#</==?</
36>/<=
%+81/
3.*$5
5 !
5 !
5 !
5 !
5 !
5 !
5 !
5 !
69A<+>/=+</./:/8.+8>980//.A+>/<;?+63>C+8.7/.3+=/6/->398
.$0 2(-,
5(+3+-.$0 2(,&.0$1130$ ,+<
5(+3+-.$0 2(,&2$+.$0 230$ H
=/:+<+>/6C=?::63/.,69A/<:+-5+1/3=</;?3</.09<>2/,+-5A+=29:/<+>398
*$"20(" *13..*6
?>97+>3-79./6= ( D
.2(-,1
σ293-/902312;?+63>C7/.3+
σ +8?+69<+?>97+>3-+3<@/8>=
σ3<384/->398=C=>/7-97:</==9<384/->9<-98><96:+8/6
σ69A/<:+-5+1/
σ98><96:+8/609<+?>97+>3-,+-5A+=2381,+=/.98>37/9<:</==?</.3J/</8>3+6
'$)#'!/#,",")*(!*++#.',-*( ,"(&)'0/*+*.,"*#!",,(&',#%+/#,"(-,'(,#
*-$1 '!
)B&
)$
%A!
%AGDDDJDDD
2
3/?0
7
823&-&1'/1-".$&
,/6 $3*5&"8&1 /..&$3*/.2 "$+6"2)
.3)1"$*3& ".%
/4#,&"8&1 *. "7 /- ,/6 *-&
7 7
- )1 - )1 - )1 -- -- *.$)&2 - )1 -*.2
1½
2½
2½
823&-*-&.2*/.2
/%&, 823&- &22&,
!*%3) &03) &*()3 !&*()3 *"-&3&1 &*()3
-- -- -- +( -- --
800 650 1914 70 522 1666
900 750 2140 90 595 1892
1050 900 2140 135 746 1892
1200 1150 2140 190 896 1892
1550 1400 2302 320 1250 2005
"3&1*",0&$*9$"3*/.2
/%&,
*0*.(
&22&, !
0&1"3*/.
"7*-4-0&1"3*.(1&2241&
"7*-4-0&1"3*.(&-0&1"341& #
,&$31*$",400,8
"
/1)*()&1:/61"3&"00,*$"3*/.2$/.24,38/41,/$", &/,*"!"3&1/,43*/.2&$)./,/(*&2$/-0".8%&3"*,2#&,/6
)B&&
)$
; % 4 (9
94
7
; !,(!5
4
%A!
; #5
%AGDDDJDDD
2
3/?0
7
:45(/(3)13/$0&(
.18 &5,7($:(3 100(&5,104 $&-8$4+
05+3$&,5( $0'
16%.($:(3 ,0 $9 1/ 9 9 .18 !,/(
/ +3 / +3 / +3 // // ,0&+(4 / +3 /,0
2½
.18 &5,7($:(3 100(&5,104 $&-8$4+
05+3$&,5( $0' $30(5 $30(5
,0 $9 1/ .18 !,/(
!3,2.($:(3 9 9 9 9
/ +3 / +3 / +3 // // // // ,0&+(4 / +3
/,0
! 2½
!
!
!
!
!
!
.18 &5,7($:(3 100(&5,104 $&-8$4+ ,04(
.($0,0*
&5,7$5(' &5,7$5('
,0 $9 1/ ,.(9 .18 .18 !,/(
$3%10 $3%10
/ +3 / +3 / +3 -* // ,0&+(4 / +3 / +3 /,0
2½
:45(/,/(04,104
1'(. :45(/ "(44(.
#,'5+ (25+ (,*+5 #(,*+5 ,$/(5(3 (,*+5
! // // // -* // //
1900 1450 2300
2250 1700 2410
2500 2000 2670
2800 2300 2720
3000 2450 2920
3300 2700 3060
3900 3200 3320
1900 1450 3300
2250 1700 3410
2500 2000 3670
2800 2300 3720
3000 2450 3920
3300 2700 4060
3900 3200 4320
)B"
"$/
%A!
%AGDDDJDDD
2
3/?0
7
!;56)0 )4*240%1')
/29 211)'6-215 %'.9%5,
2()/5 -1 %: 20 #)55)/ #)55)/ /29 "-0)
0 ,4 0 ,4 0 ,4 -1',)5 -1',)5 0 ,4 0-15
"
" ½
" ½ ½
" ½ ½
" ½ ½
'6-8)%;)4
2()/5 16,4%'-6) !%1( %41)6 %41)6
: : : :
00 00 00 00
"
"
!;56)0-0)15-215
2()/ !;56)0 #)55)/
$-(6, )36, )-+,6 $)-+,6 -%0)6)4 )-+,6
" 00 00 00 .+ 00 00
800 650 1914
900 750 2140
1050 900 2140
1300 1150 2140
1550 1400 2302
"
1900 1450 2300
2250 1700 2410
2500 2000 2670
2800 2300 2720
3000 2450 2890
3300 2700 3060
3900 3200 3320
%6)4-%/!3)'-<'%6-215 3)4%6-21
2()/ " " %:-0703)4%6-1+ 4)5574) #
-3-1+ &!!# &!!#!#$% $$ %:-0703)4%6-1+")03)4%674) *
#)55)/ !( "!'(!%#! $%
24,-+,)4=294%6)%33/-'%6-215'2157/6;274/2'%/
/)'64-'%/!733/; #)2/-%$%6)4!2/76-215")',12/2+-)5'203%1;
) ()6%-/5&)/29
Softening
Softening
Salts of calcium and magnesium have low solubility. In water they are collectively
called “hardness” and cause a variety of problems in industrial water use, including:
Ion exchange softening is the most widely used softening process. Water is passed
through a bed of cation exchange resin where calcium and magnesium ions are
removed from the water in exchange for sodium ions. When the sodium ions on
the resin have been replaced by calcium or magnesium ions, the softening reaction
stops and the resin need to be regenerated. Regeneration is achieved by passing a
salt solution through the resin bed.
Berkoion™ Softeners
Compact Range
Z Series
Z15 KV 1.0 - 1.2 1.1 3.75 R1 1.4 - 8.5 570 1090 435
A Series
A13 KV 2.0 - 2.3 0.64 1.17 Rp 1 1.4 - 8.0 590 1090 280
*A Series - With pressure loss of 0.8 bar and mixing from 20 to 8°dH (358 to 143 ppm CaCO3)
Z15 KV - With pressure loss of 0.32 bar at 1.2 m3/h
Material Specifications
Resin Vessels Glass Reinforced Plastic (GRP)
Brine Tanks Polyethylene (PE)
Electrical Supply
All models 230V 50Hz standard
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/Berkoion™ Compact Range/AQF0013_EN_V2.0-Nov.13
'%)&
"'%&&&%)!&(##"%'
σ %"%."(!'%(%%!'%!%
' &"/%#%)!'')!
'"!%(&&'(&!*&'
"%%') !'!!#%"% &
#%")&'%'*'%$(',
'"!&(%'"!'% 0!'
σ )!"!'%"%*' "#%'"!"!&'#!'
&#,%!""!'%""#'"!&
&,'"(&!'%'&*'
!'%&"!'%"&,&' &
3/0#*#.$,.*+!#
,"#) ),20#/ -!'03 )0/%# ,++#!0',+ ,.('+% '"0& #'%&0 #-0&
#.#%#+ .#//1.#/
1 -5 /,& /, !4.2(-*611 '&5 11 11 11
'*#!,+0.,))#"/#*'10,*0'!
!4A
!4A
!4A
!4
!4
'*#!,+0.,))#"10,*0'!
!4
!4
!4
!4
,)1*#!,+0.,))#"10,*0'!
!4
!4
!4
!4
*5(35*?(3827*5(855*275*,*2*5&7.32
'/-)3/,+0.,))#./
)#!0.,+'!,+0.,))#. %"*5.*6
'!.,-.,!#//,.,+0.,))#.2'0&'/-)3 $ $ $$
0#.')-#!'4!0',+/
#/'+#//#)/ 0&66!*.2+35(*) 0&67.(!
.'+#+(/ 30<*7-<0*2*
##"0#.1--)31)'03
37&'0*:&7*5+5**+53135,&2.((327&1.2&7.32&2)6864*2)*)1&77*5&;.1817*14*5&785* @ @+35% &2)%
)#!0.'!)1--)3
# =67&2)&5)2368440<2*(*66&5<+35 &2)
,.&'%&#.5,2.0#--)'!0',+/!,+/1)03,1.),!)#,)'0#.,)10',+/#!&+,),%'#/!,*-+3"#0')/ #),2
Berkoion™ Softeners
Classic Duplex Range
Volume controlled
AWA 2-25 1.4 - 2.0 1.3 2.5 Rp 1 1.8 - 8.5 1110 1087 390
AWA 2-45 2.3 - 3.2 2.3 4.0 Rp 1 2.0 - 8.5 1310 1577 530
AWA 2-70 2.8 - 3.5 3.5 6.5 Rp 1 2.0 - 8.5 1447 1556 530
AWA 2-90 4.0 - 5.0 4.5 8.0 Rp 1 2.0 - 8.5 1579 1832 600
AW 2-105 6.0 - 7.2 4.8 8.6 DN 40 2.0 - 8.5 1748 1918 650
AW 2-150 8.0 - 10.0 7.1 12.6 DN 40 2.5 - 8.5 2190 1928 980
AW 2-250 12.0 - 14.0 12.2 21.6 DN 50 2.5 - 8.5 2482 1895 995
AW 2-350 15.0 - 17.0 17.3 30.6 DN 50 2.5 - 8.5 2853 2228 1185
Material Specifications
Resin Vessels Glass Reinforced Plastic (GRP)
Brine Tanks Polyethylene (PE)
Electrical Supply
All models 230V 50Hz standard
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/Berkoion™ Classic Duplex Range/AQF0040_EN_V3.0-Nov.13
Volume controlled
AW 2-550 2.7 - 27.0 28.0 49.5 DN 80/80 3.0 - 8.5 3195 2650 1390
AW 2-800 3.9 - 39.0 40.7 72.0 DN 100/80 3.0 - 8.5 3945 2735 1695
AW 2-1050 5.1 - 51.0 53.4 94.5 DN 100/80 3.0 - 8.5 4490 2815 1770
AW 2-1400 6.8 - 68.0 71.2 126.0 DN 100/100 3.0 - 8.5 4665 2910 1925
Material Specifications
Resin Vessels Glass Reinforced Plastic (GRP)
Brine Tanks Polyethylene (PE)
Electrical Supply
All models 230V 50Hz standard
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/Berkoion™ High Flow Duplex Range/AQF0043_EN_V2.0-Nov.13
Osmosis
Reverse
Reverse osmosis (RO) is a process that uses a membrane to remove over 95% of
dissolved salts, such as calcium bicarbonate and sodium chloride, from water. It is
used either alone or in combination with processes such as ion exchange in a variety
of industrial applications where the total dissolved solids (TDS) concentration in
water has to be reduced, including:
The RO membrane also acts as a very fine filter removing 99% of suspended and
colloidal solids, bacteria and organic molecules with molecular weights in excess of
about 200Da. This makes the process particularly attractive for applications where
treated water not only has to be low in TDS but also of high clarity and free from
bacteria, such as that used for soft drinks and pharmaceuticals manufacturing.
SIRION Mini
TM
Option
Output to PLC via analogue signal
for conductivity monitoring
SIRION Mini
TM
System Performance
Model 10-15 EP 10-40 EP 10-80 EP
Nominal Flows at 12°C*
Permeate l/hr 10-20 30-45 60-90
Feed l/hr 40 90 170
Typical Salt Rejection % 96-98 96-98 96-98
Pump Motor Size kW 0.25 0.25 0.25
*Flow rates are dependent on feed water quality, those quoted are typical values based on 1000 ppm TDS & SDI <3.
System Dimensions
Model 10-15 EP 10-40 EP 10-80 EP
Height mm 697 697 697
Depth mm 380 380 380
Width mm 450 450 450
Weight kg 53 60 63
Pipe Connections
Model 10-15 EP 10-40 EP 10-80 EP
Feed Water (BSPP Male) 1/2'' 1/2'' 1/2''
Permeate (push in) 8 mm 8 mm 8 mm
Concentrate (push in) 8 mm 8 mm 8 mm
Electrical Supply
All models 230V 50Hz standard.
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION™ Mini/AQF0010_EN_V3.0
System Dimensions
Model 10-100 EP 10-200 EP 10-300 EP 10-500 EP 10-750 EP
Height mm 1010 1260 1260 1260 1260
Depth mm 620 620 620 620 620
Width mm 600 600 600 600 600
Weight kg 59 61 68 73 95
Pipe Connections
Model 10-100 EP 10-200 EP 10-300 EP 10-500 EP 10-750 EP
Feed Water (push in) 12 mm 12 mm 12 mm 15 mm 15 mm
Permeate (push in) 12 mm 12 mm 12 mm 15 mm 15 mm
First Permeate (push in) 12 mm 12 mm 12 mm 15 mm 15 mm
Concentrate (push in) 12 mm 12 mm 12 mm 12 mm 12 mm
Electrical Supply
10-100EP to 10-300EP models 230V, 1ph, 50 Hz standard
10-500EP & 10-750 EP models 400V, 3ph–N–PE, 50 Hz standard
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION™ Midi/AQF0009_EN_V3.1 - Dec.13
System Dimensions
Model 14-500-EP 14-750-EP 14-1000-EP 14-1500-EP 14-2000-EP 14-2500-EP 14-3000-EP 14-4000-EP* 14-5000-EP*
Height mm 1630 1630 1630 2358 2358 2358 2358 2950 2950
Depth mm 1070 1070 1070 1070 1070 1145 1070 1200 1200
Width mm 636 636 636 636 636 636 636 800 800
Weight kg 200 220 240 290 330 370 410 300 325
*If height is an issue consider the SIRION™ Mega
Pipe Connections
Model 14-500-EP 14-750-EP 14-1000-EP 14-1500-EP 14-2000-EP 14-2500-EP 14-3000-EP 14-4000-EP 14-5000-EP
Feed DN 20 DN 20 DN 20 DN 25 DN 25 DN 32 DN 32 DN 40 DN 40
Concentrate DN 15 DN 15 DN 15 DN 15 DN 15 DN 25 DN 25 DN 25 DN 25
Permeate DN 15 DN 15 DN 15 DN 25 DN 25 DN 25 DN 25 DN 32 DN 32
First Permeate DN 15 DN 15 DN 15 DN 25 DN 25 DN 25 DN 25 DN 32 DN 32
All connections are union socket - PVC-U
Electrical Supply
All models 380/415V, 3 phase, 50Hz standard.
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION™ Maxi/AQF0007_EN_V3.1 - Dec.13
System Dimensions
Model 110 x 2* 110 x 3 110 x 4 210 x 4 211 x 4 211 x 5 320 x 5
Pipe Connections
Model 110 x 2 110 x 3 110 x 4 210 x 4 211 x 4 211 x 5 320 x 5
Feed DN 40 DN 40 DN 50 DN 50 DN 65 DN 65 DN 80
Permeate DN 40 DN 40 DN 40 DN 50 DN 50 DN 65 DN 65
Concentrate DN 40 DN 40 DN 40 DN 40 DN 40 DN 40 DN 50
All connections are union socket - PVC-U
Electrical Supply
All models 380/415V, 3 phase, 50Hz standard.
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION™ Mega/AQF008_EN_V4.1 - Dec.13
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION™ Multipure/AQF0016_EN_V2.0
Options
• Treated water diverted at start-up;
ensures water quality
• Monitoring of temperature
SIRION™ Basic (130 - 350 Series)
System Performance
System Dimensions
Weight kg 59 61 68
Pipe Connections
Electrical Supply
230V, 50Hz standard.
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, contact details below.
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION™ Basic 130-350 Series/AQF059_EN_V3.1
*Flow rates are dependent on feed water quality and Temperature, the above values are based on 1000 ppm TDS, 12°C.
System Dimensions
Pipe Connections
Electrical Supply
All models 380/415V, 3 phase, 50Hz standard.
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION™ Basic 5000-20000 Series/AQF061_EN_V2.1
Material Specifications
Low Pressure
Prefilter Housing Polyamide (PA)
Filter Element Polypropylene
Dosing Pumps PVC head, Teflon-coated EPDM diaphragm
Chemical Product Tanks PE
Flushing and Chemical Cleaning Tank FRP
Flushing and Chemical Cleaning Pump Stainless steel
Piping and Accessories PVC-U / PN-16
High Pressure
High-Pressure Pump Stainless Steel AISI 904-L / Super Duplex
(depending on the model)
Pressure Vessels FRP
RO Membranes Link crossed aromatic polyamide (8”)
Piping and Accessories Stainless steel for seawater applications
AISI 904-L (Standard) ZERON/ 254 SMO (Options)
Skid Epoxy-painted carbon steel
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, details below.
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/SIRION™ Sea Water/AQF0017_EN_V3.0
Ultrafiltration
suspended solids including fine particulates, colloids and high molecular weight
dissolved materials.
Applications include:
Surface water
Borehole water
Swimming pool water
Recycling/reuse
RO feed water
Oil/water separation in emulsion
Recovery of metal particles
Regeneration of degreasing/cleaning solutions
2.5 to 44
2.5 to 176
55 11 165 220
2.5 - 11 5 - 22 7.5 - 33 10 - 44
55 11 165 220
2236/2156* 2236/2156* 2252/2178* 2276/2194*
50 50 50
3 - 19 Aug.2013
Deionisation
n
There are many industrial processes in which the presence of any dissolved salts
in water can cause problems. Removing all the dissolved salts from water is called
deionisation or demineralisation. Processes that need high purity water include:
High pressure boilers
Chemical manufacture
Toiletries and cosmetics production
Deionisation
Humidification systems
Battery top-up
Surface finishing
For industrial processes requiring high purity water, the most widely used purification
technology is twin bed ion exchange deionisation. The ion exchange resins are
contained in two separate pressure vessels and flow through them in series. Raw
water enters the cation exchange vessel and passes down through the resin bed
where calcium, magnesium, sodium and other cations are removed from the water
in exchange for hydrogen ions. The water then passes through the anion exchange
vessel where chloride, sulfate, bicarbonate and other anions are removed in exchange
for hydroxide ions. When the hydrogen and hydroxide ions on the resins have been
replaced by the cations and anions from the water, the deionisation reaction stops
and the resins need to be regenerated.
)
!&%!*+!&%/*+$*
σ )**$#*"!$&,%+ σ ++)/+&','
*/*+$ ),*!%*+##+!&%&*+*
%%*,)*)'!*+)+,'+!$ #+)-!*
σ &')+!&%.!+ %&$!%* &#+)*#**)-!%*,''&)+
#+)!#&%%+!&%* +$*&4)')-%++!-%
σ ++)/&')+&%,+!-!+/ &))+!-$!%+%%')&)$*
$+)&)*/*+$(,#!+/&%+)&# +&%*,)+ #&%+)$5!%+
%&')+!&% &')+!&%&!%*+##'#%+
σ &%)+,)%-#-*%)"+%"*
%1++!)(,!)
σ %,##/)%)+
:45(/(3)13/$0&(
1'(.
$9,/6/.18 0-6
,0,/6/.18 0-6
25,/6/.18)13$9,/6/$2$&,5: 0-6
(*(0(3$5,10 ,/( -3967
3(4463(144$5$9,/6/.18 '&6
3(4463(144$525,/6/.18 '&6
$9,/6/.18513$,063,0*(*(0(3$5,10 0-6
=6(05"1.6/(2(3(*(0(3$5,10 0
+(/,&$.!4$*(2(3(*(0(3$5,10
0
$ 0
652652(3(*(0(3$5,10
/* . 15$.0,101$'$4$ 0& , 1
:45(/,/(04,104#(,*+54100(&5,104
1'(.
(,*+5 11
(25+ 11
#,'5+ 11
(&1//(0'('($'311/ 11
22319(37,&(#(,*+5 /,
,2(100(&5,104
0.(58,5+ /56%,0* .2(-*7
65.(58,5+ /56%,0* .2(-*7
3$,08,5+/56%,0* .2(-*7
1&0*#!(322*(8.327&07379440.*)
3($5('#$5(36$.,5:
$#1, 32)9(8.:.8=A#(1
3
$5(3,$.2(&,;&$5,104 (('#$5(3622.:6$.,5:
!38&'0*;&8*6+6**+63136,&2.((328&1.2&8.32(-036.2*&2)7974*2)*)730.)7
3(4463("(44(.4 31437.8*40&78.( #9440=!6*7796* 1.2 '&6 1&<'&6
,2(813- !% $*14*6&896* 1.2B 1&< B
-,' 43<=(3&8*)1.0)78**0 .(&53,&$.622.:
10531."$.7(4 &29&00=34*6&8*)'&008=4* &88*6=6*59.6*)%!! 36*59.:&0*28
13+,*+(3<183$5($22.,&$5,104&1046.5:163.1&$."(1.,$#$5(3
1.65,104 (&+01.1*,(4&1/2$0:'(5$,.4%(.18
60%-+14'?
'+0/+4#5+0/ :45'.4
934'.+.'/3+0/3"'+)*4#/&0//'%4+0/3
0&'- 150 300 400
'+)*4 mm 1505 1965 2050
'14* mm 670 670 700
"+&4*8%')'/0/4#+/'23 mm 870 1070 1250
'%0..'/&'&'#&200. mm 1000 1000 1000
'%0..'/&'&'#2%%'33 mm 1000 1000 1000
11208'26+%'"'+)*4 kg 480 835 950
/-'4 inc he s 1 1 1
54-'4 inc he s 1 1 1
2#+/ inc he s 1 1 1
2'#4'&"#4'25#-+49
0&'- 150 300 400
mg/l <1 0 <1 0 <2 0
0/&5%4+6+49 μS /c m M a x imum: <3 0 A v e ra g e : <2 0
#4'2+#-1'%+;%#4+0/3
2'3352'!'33'-3 0.104+5'1-#45+%
+1'702, #/&6"
,+& 109:%0#5'&.+-&45''-
0/420-!#-6'3 03:-1-#45+%
0/420-#$+/'4 '/%-0463'
''&"#4'2511-95#-+49
05#$-'8#5'3(3''(30.03)#/+%%0/5#.+/#5+0/%*-03+/'#/&4641'/&'&40-+&4
!'.1'3#563' +/ @ #9 @
-'%42+%#-511-9
"03 "4+/)-'1*#4' ;
02*+)*'2<072#4'#11-+%#4+0/3%0/35-49052-0%#-!'0-+#"#4'20-54+0/3'%*/0-0)+'3%0.1#/9&'4#+-3$'-07
$2,'(@!64$6$
"9,0%('(,10,5(45
9,6+!+146;&.( (*(0(4$6,10
48-30)17-0)16-216
2()/
)-+,7 ::
)37, ::
$-(7, ::
)'200)1()()%(5220 ::
3352; )59-')$)-+,7 85
))(1/)7 ::
)59-')87/)7 ::
)+)1)5%7-21$%7)51/)7 ::
5%-1 ::
!5)%7)($%7)58%/-7<
! 0+ / 21(8'7-9-7<? '0 )6-67-9-7<A'0
%3-()! 75%7% :/E /C3?/53 :/E /C3?/53
%3-()! 75%7%
25,-+,)5>2:5%7)%33/-'%7-216'2168/7<285/2'%/#)2/-%$%7)5
2/87-216!)',12/2+-)6'203%1<'217%'7()7%-/6&)/2:
Continuous Ele
Electrodeionisation
ectrodeiionisatiion (CED
(CEDI)
DI)
Applications include:
Pharmaceutical
High pressure boiler feed
CEDI
Humidification systems
Microelectronics
Central laboratory
Ultraviolet Disinfection
Disiinfectio
on
Disinfection
the concentration of colloidal and particulate constituents in the water.
UV
UV Water Treatment
UV Disinfection - Industrial range
A – Disinfection at 26mJ/cm 2 RED MS2 Phage, 95% T10 transmittance at the end of lamp life
B – Disinfection at 26mJ/cm2 RED MS2 Phage, 98% T10 transmittance at the end of lamp life
UV Chamber Specifications
Material AISI 316L : DN 1.4404 Water Temperature +5 to +40°C
Finish External Passivated & Electropolished Maximum CIP Temperature 95°C
Protection IP65 / NEMA 4 Finish internal: As made pipe Finish internal: As made pipe
and tube, welds left as laid, and tube, welds left as laid,
electropolished and passivated electropolished and passivated
Pressure 9 bar, max operating* * UV 900i 6 Bar max operating pressure
UV Lamp Specifications
Long life 254Nm amalgam lamp.
Lamp Life – Expected 16,000 hours (12,000 Hours UV230i, UV468i & UV900i) Warranty 9,000 hours. Based on less than 4 start/stop cycles per 24 hours.
Documentation
All units are supplied with a Certificate of Conformity.
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/UV Water Treatment - Industrial range/ AQF060_EN_V2.0
m3/hr W mm mm kg TC – Triclamp
+/- 5mm Inches
A B Lamp Total Empty Full
A – Disinfection at 26mJ/cm2 RED MS2 Phage, 98% T10 transmittance at the end of lamp life
B – Deozonisation is based on a 90% reduction of Ozone at 98% T10 transmittance at the end of lamp life
UV Chamber Specifications
Material AISI 316L : DN 1.4404 Water Temperature +5 to +40°C
Finish External Passivated & Electropolished Maximum CIP Temperature 95°C
UV Lamp Specifications
Long life 254Nm amalgam lamp.
Lamp Life – Expected 16,000 hours (12,000 Hours UV230P, UV560P & 1120P) Warranty 9,000 hours. Based on less than 4 start/stop cycles per 24 hours.
Documentation
All units are supplied with a Certificate of Conformity, with material certificates, lamp output certificates & FDA Validation pack.
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/UV Water Treatment - Pharma range / AQF078_EN_V1.1
Applications include:
Filtration, softening and RO for utility feed and process water
Filtration, softening, RO and DI for healthcare, microelectronics and laboratories
Filtration, softening, twin pass RO and CEDI for pharmaceutical
RO & CEDI for high pressure boiler feed
RO & CEDI for healthcare, microelectronics and central laboratory
The existence of similar applications and thus water requirements across different
businesses has encouraged water treatment companies to propose pre-packaged
multi-technology solutions. Typically such solutions are skid-mounted or containerised
and have smaller footprints than combined independent technologies. They also
have the advantage of being pre-piped and pre-configured prior to delivery for quick
installation and start-up. In addition, the control systems are specifically designed to
Technology
Solutions
monitor and control the combined technologies making for an efficient and easy to
Multi-
use system.
.-
%5%12%2,.2)2
$=;7</::=EA/@357D3<4=@7<271/B7=<;=@3/11C@/B3>@=831B7=<A1/<03=0B/7<32CA7<5B63)GAB3;)7H7<5&@=5@/;;3))&
!,*5<,8?
&0+:/ ;; E7B6=>B7=</:35/AA3@
,6:/ ;; E7B6=>B7=</:35/AA3@
03,490549
,0./: ;;
&,0./: 95
"(2:#(41 0(>,0./: ;; F
"(2:$9(.,6,8!,.,4,8(:054 95
"5-:,4,8;:6;:6,8!,.,4,8(:054
;
3. 2#5:(2(8+4,99(9(
,,+ )&3;/:3
85+;*: ;;C&,)=193B+<7=<
544,*:0549
!,:;84 ;;C&,)=193B+<7=<
8(04 ;;C&,)=193B+<7=<
2,*:80*(2";662? @ ,>6/A3 H 9,
2,*:80*(2";662? @ ,>6/A3 H9,
5=,8549;36:054 3>3<2A=<=>3@/B7<51=<27B7=<A )33))&
(:,80(2"6,*0A*(:0549 ,,+&(:,8!,7;08,3,4:9
"5-:,4,89 $=@G: 3/2A&=:G3B6G:3<3"7<32,3AA3:A 3<3@/: &=B/0:3E/B3@4@334@=;=@5/<71A1=::=72A
"5-:&(:,8#(41 7563<A7BG&=:G3B6G:3<3 /<2ACA>3<232A=:72A)!
58/0./,8B5=8(:,(6620*(:0549*549;2:?5;825*(2%,520(&(:,8"52;:0549#,*/4525.0,9*536(4?+,:(029),25=
)&!!+%)#1%.$.$!+,*#,!--%0!)./,!*".$!*(+)21!,!-!,0!.$!,%#$..*(!) !.%'-1%.$*/.)*.%!
*)3&
7$6641?
7.6, (&+01.1*;1.76,10
0//'%5+0/4+.'/4+0/4
0&'-
/-'5 /+0/ mm 20 20 25 32
65-'5 /+0/ mm 15 15 20 25
65-'53+%-#.1 mm 10 15 20 25
3#+/ /+0/ mm 50
#5'3+#-1'%+<%#5+0/4
3'+1'803, >#)
0(5'/'34 #+7.%#8698<3=/
#353+&)'+-5'3064+/) #85B9;89B5/7/
6-5+163104'#/, #
'7'34'4.04+4+)*3'4463'+1'803,!'44'-4 &=+375/<<&=//5
+1'803, >#)
+1'803,15+0/ &=+375/<<&=//5
,+& &=+375/<<&=//5
0/530-#$+/'5 #+37=/. 35.&=//5
''&"#5'3'26+3'.'/54
'/'3#- #8=+,5/@+=/;0;//0;868;1+73-<-85583.<+7.<><9/7./.6+==/;&
3''*-03+/' 61 5
'.1'3#563' F I I
3'4463' F,+; #&
*3=2+-=3?+=/.-+;,87-+;=;3.1/D5=/;<D==/.
:1+%#-3'#5'&"#5'36#-+5:
0/&6%5+7+5: G& -6
#%5'3+# -0> 65@3=2()89=387 -0> 65@3=28>=()89=387
99,
/9/7.<870//.@+=/;:>+53=BE8@;+=/9;8.>-=89=387</5/-=/.
03*+)*'3=083#5'#11-+%#5+0/4%0/46-5:063-0%#-!'0-+#"#5'30-65+0/4'%*/0-0)+'4%0.1#/:%0/5#%5&'5#+-4$'-08
Clarification
n & Flotation
Flotatio
on
Applications include:
Primary clarification of wastewater
Treatment of biofilter backwash water
Clarification of trickling filter effluents
Storm water treatment
Tertiary polishing or phosphorus removal
Drinking water treatment, both ground and surface waters
Giardia and cryptosporidium removal
Pre-treatment of industrial process waters
Recycling/reuse
Clarification
& Flotation
Flotation DAF is a process using air dissolved in water in order to achieve solid/liquid
separation.
In order to increase the process efficiency, chemical additives are normally dosed.
Coagulation followed by flocculation inside the treated fluid is achieved.
Coagulation is meant to destabilise solid particles in stable equilibrium inside
the fluid, while flocculation is meant to gather the particles into bigger and more
extended flocs.
Actiflo® Mini
The Ultimate Microsand
Enhanced Clarifier
Length 3m
Width 1m
Height 2.7 m
1 x pH at Coagulation Tank
3 x Flowmeter at Inlet, Recirculation & Sludge Line
Monitoring Instrument (Standard) (****)
1 x Pressure at Hydrocyclone Inlet
2 x Turbidity Meter at Inlet & Outlet
(*) In case of the operation at < 5 m3/H, the separation of sludge from microsand should be investigated, due to over-mixing in Maturation Tank.
(**) 220V x 3 phase x 50/60Hz is optional.
(***) Additional chemical dosing or different type of chemical should be discussed prior to the order.
(****) Additional monitoring should be discussed prior to the order.
Actiflo® Mini is supplied as a complete functional system, including chemical preparation and dosing equipment as well as integrated PLC & SCADA.
It can be supplied as a stand-alone unit or pre-installed in a 20’ container.
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, contact details below.
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/Actiflo® Mini/AQF0124_EN_V1.1
40 80
80 160
160 320
320 640
./"1/"-
80 160
160 320
320 640
640 1280
)&/&(").&*).
")$/% &!/% 2"&$%/.."('"!
/"- ("/"-. ("/"-. ("/"-.
4. 1 1. 8 4.2
5. 1 2. 4 4.8
5. 7 2. 7 4.8
8. 2 3. 6 4.8
./"1/"-
4. 1 1. 8 4.2
5. 1 2. 4 4.8
5. 7 2. 7 4.8
8. 2 3 .6 4.8
Actiflo® Turbo Pack
The Ultimate Microsand
Enhanced Clarifier
Flows (m3/d)
Model 60 m/h 80 m/h 120 m/h
(Drinking / Process Water) (Municipal / Industrial Wastewater)
ACP2-15 1 500 2 000 3 000
Unit Dimensions
Dimensions (mm)
Model
Height
Length Width
(Tank) (Assembled)
ACP2-15 4 156 2 029 2 859 4 479
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company, contact details below.
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/Actiflo® Turbo Pack/AQF0123_EN_V1.1
Membrane Bioreactors (MBR) are used to treat industrial and municipal wastewaters to
produce high quality effluents suitable for water reuse applications – either directly
or following a reverse osmosis treatment stage. MBR combine two basic processes:
biological treatment and membrane separation in either a single tank or separate
tanks. The biological breakdown of the pollution takes place in an aerated reactor
containing suspended microorganisms (biomass or activated sludge). The key
differentiator of MBR is that the biological process is coupled with membranes
for biomass filtration instead of using conventional separation processes, such as
clarification and flotation.
Applications include:
Small or medium sized industrial or municipal effluent treatment plants
Temporary solutions during refurbishment or upgrade work
Recycling for boiler feed, process water, aquifer recharge, public utility
Biosep™ Pack
Equipment & Dimensions
Antifoam Membrane
Membrane Tank skid Backwash Air Power
*Membrane tank height must be selected with site constraints (aeration basin and discharges levels)
**2 backwash solutions are available, it must be chosen depending on potable water availability (3m3/h at 1 bar minimum)
Typical Performances
COD < 50mg/l*
BOD5 < 5 mg/l
Suspended Solids < 3mg/l (detectable threshold)
Total Nitrogen < 10-15 mg/l
Material Specifications
Membrane Tank Fiber Reinforced Platsic (FRP)
Access Fittings (ladder, platform, guard rails) Epoxy Coated or 304 L
Skid PE
Piping PE / PVC / PVC-C
For higher flow rate applications consult your local Veolia Water Solutions & Technologies company.
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE/Biosep™ Pack/AQF0034_EN_V3.1 - 11.2012
,0%+(")/"-#*-() "
*!"' ( 0("-*#%. . */*-/%)$ *'0("*#
%*!%. )&.
*!%.&4%'/"-0.*%'0)%/%2" & (5
*-*-
+" %3 /)!-!0/'"/",0%-"(")/.
0/'"/1'0". ($'
!"
Evaporation
Evaporation
'$)#'!/#,",")*(!*++#.',-*( ,"(&)'0/*+*.,"*#!",,(&',#%+/#,"(-,'(,#
.%
Mobile Water
Wate
er Solutions
Solution
ns
Veolia Water Solutions & Technologies offers Aquamove™ service to industries using
purified water for their production lines or utilities. Aquamove™ constitutes a large
fleet of mobile water treatment units, that may be deployed as stand-alone units
or combined to form complete systems: skid-mounted systems, containers and
trailers.
Aquamove™ offers emergency hire, planned temporary hire and long-term contract for:
Boiler, turbine feed water
Process water
Cooling water
Drinking water
Wastewater
Aquamove™ safeguards the production of the purified water when clients are facing:
Plant commissioning
Filling pressure boilers
Equipment breakdown
Plant downtime for maintenance purposes
Raw water changes
Peak demand
Process trial validation
Technologies available:
Reverse osmosis
Deionisation
Ion exchange polishing
Softening
Filtration
Activated carbon
Clarification
Evaporation, …
Mobile Water
Solutions
Water Treatment Chemicals
Veolia operates more than 5000 water treatment facilities across the world,
including process, boiler feed, cooling water, waste water and sludge treatment. Our
research & development team constantly innovates and delivers new technologies
that provide optimum solutions to environmental problems with a high-value to our
clients’ businesses. Hydrex™ chemicals are committed to complying with all chemical
regulations (ie Reach, Biocides Directive in Europe,…).
Veolia Water Solutions & Technologies offers Hydrex™ program to optimise the
entire water cycle, chemical consumption, operating and maintenance costs.
Protecting water treatment systems against scale deposition, corrosion, fouling, etc.
Reducing unnecessary downtime
Ensuring optimum productivity
Preventing and reducing environmental risks
Allowing energy saving
Veolia Water Solutions & Technologies works in partnership with its customers to
ensure the optimal running of their water treatment facilities.
Veolia Water Solutions & Technologies offers a wide range of consumables and spare
parts.
Cartridge filters
Reverse osmosis membranes
Ion exchange resins
Activated carbon and other filtration media
CEDI stacks
Valves
Instrumentation
Dosing systems
UV systems
Test kits, etc.
Related Services
Local after-sales service and support
teams offer preventative and
corrective maintenance programs
to ensure the long-term, efficient
Performance operation of installed plant.
200 3
Differential Pressure (mbar)
100
0 0
0 2 4 6
Performance
Chlorine Reduction per 10" based on 2 ppm Inlet Concentration 22700 litres @ 3.8 l/min (6000 gallons @ 1 gpm)
Dimensions
Outside Diameter 2.7"
Inside Diameter 1.1"
Ordering Information
Length Micron End Fiting Part Number
9" 3/4 10 DOE CFCBYS9 510
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /FILOTM Carb/AQF113_EN_V1.2
400 6
Differential Pressure (mbar)
200
0 0
0 2 4 6
Performance
Chlorine Reduction per 10" based on 2ppm inlet Concentration 76000 litres @ 3.8 l/min (20000 gallons @ 1 gpm)
Dimensions
Outside Diameter 2.7"
Inside Diameter 1.1"
Ordering Information
Length Micron End Fiting Part Number
9" 3/4 1 DOE CFCBYS9 511
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /FILOTM Carb-HP/AQF114_EN_V1.2
Performance
200 3
m
1μ
Differential Pressure (mbar)
m 2
5μ
100 m
10 μ
m
25 μ 1
0 0
0 10 20 30
Dimensions
Outside Diameter 2.7" (68 mm)
Ordering Information
Length Micron End Fiting Part Number Length Micron End Fiting Part Number
DOE CFYKYS9 410 DOE CFYKZE9 411
1 CODE 7 CFYKYS9 450 1 CODE 7 CFYKZE9 451
CODE 3 CFYKYS9 440 CODE 3 CFYKZE9 441
DOE CFYOYS9 411 DOE CFYOZE9 411
5 CODE 7 CFYOYS9 450 5 CODE 7 CFYOZE9 452
CODE 3 CFYOYS9 440 CODE 3 CFYOZE9 441
9" 3/4 30"
DOE CFYTYS9 410 DOE CFYTZE9 410
10 CODE 7 CFYTYS9 450 10 CODE 7 CFYTZE9 450
CODE 3 CFYTYS9 440 CODE 3 CFYTZE9 440
DOE CFZDYS9 410 DOE CFZDZE9 410
25 CODE 7 CFZDYT9 450 25 CODE 7 CFZDZE9 450
CODE 3 CFZDYS9 440 CODE 3 CFZDZE9 440
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /FILOTM Pleat/AQF115_EN_V1.1
Performance
Absolute rating from 0.6 to 40 μm
(> 99.99% retention at micron
rating) 100
μm
0.6
Differential Pressure (mbar)
μm
1.2 1
50
5 μm
0 0
0 10 20
Dimensions
Outside Diameter 2.7" (68 mm)
Ordering Information
Material Specification Micron End Fiting Part Number
DOE CFYGYT9 410
0.6 CODE 7 CFYGYT9 450
CODE 3 CFYGYT9 440
DOE CFYKYT9 410
1.2 CODE 7 CFYKYT9 451
CODE 3 CFYKYT9 440
10" DOE CFYOYT9 410
CODE 7 CFYOYT9 450
5
CODE 3 CFYOYT9 440
CODE 9 CFYOYT30 0 6 8 2
10 CODE 9 CFYTYT30 0 6 8 3
25 CODE 9 CFZDYT30 0 6 8 4
40 CODE 9 CFZFYT30 0 6 8 5
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /FILOTM Pleat-HP/AQF116_EN_V1.4
Performance
100
m m
1μ 5μ
m
10 μ
Differential Pressure (mbar)
75
50 20 μm
50 μm
25
0
0 20
Dimensions
Outside Diameter 2.5"
Inside Diameter 1.1"
Ordering Information
Length Micron End Fiting Part Number Length Micron End Fiting Part Number
DOE CFYKYS9300 DOE CFYKZE9300
1 CODE 8 CFYKYS9370 1 CODE 8 CFYKZE9370
CODE 3 CFYKYS9341 CODE 3 CFYKZE9341
DOE CFYOYS9300 DOE CFYOZE9300
5 CODE 8 CFYOYS9370 5 CODE 8 CFYOZE9370
CODE 3 CFYOYS9341 CODE 3 CFYOZE9342
9" 3/4 DOE CFYTYS930 0 30" DOE CFYTZE930 1
10 CODE 8 CFYTYS9370 10 CODE 8 CFYTZE9370
CODE 3 CFYTYS9341 CODE 3 CFYTZE9341
DOE CFZDYS9300 DOE CFZDZE9300
20 CODE 8 CFZDYS9370 20 CODE 8 CFZDZE9370
CODE 3 CFZDYS9341 CODE 3 CFZDZE9340
50 DOE CFZGYS9300 50 DOE CFZGZE9300
DOE CFYKZF9300
1 CODE 8 CFYKZF9370
CODE 3 CFYKZF9341
DOE CFYOZF9300
DOE CFYKZD9300 5 CODE 8 CFYOZF9370
1 CODE 8 CFYKZD9370 CODE 3 CFYOZF9341
CODE 3 CFYKZD9341 40" DOE CFYTZF930 0
DOE CFYOZD9300 10 CODE 8 CFYTZF9370
5 CODE 8 CFYOZD9370 CODE 3 CFYTZF9341
CODE 3 CFYOZD9341 DOE CFZDZF9300
20" DOE CFYTZD930 0 20 CODE 8 CFZDZF9370
10 CODE 8 CFYTZD9370 CODE 3 CFZDZF9340
CODE 3 CFYTZD9341 50 DOE CFZGZF9300
DOE CFZDZD9300 1 DOE CFYKZG9300
20 CODE 8 CFZDZD9370 5 DOE CFYOZG930 0
50"
CODE 3 CFZDZD9340 20 DOE CFZDZG9300
50 DOE CFZGZD9300 50 DOE CFZGZG9300
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /FILOTM Spun/AQF117_EN_V1.2
Performance
7
m
1μ
400 6
Differential Pressure (mbar)
5
300
4
200 3
5 μm
2
100
10 μm
1
0 0
0 8 16
FILOTM Spun-HP can be repeatedly (up to 25 times) steam sterilised in situ or autoclaved up to 130°C
Cleaning and Sterilisation (266°F). FILOTM Spun-HP filters can be sanitised with hot water at up to 90°C (400 hours in 20 minutes
cycles) and are compatible with a wide range of chemicals.
Dimensions
Outside Diameter 2.5"
Inside Diameter 1.1"
Ordering Information
Length Micron End Fiting Part Number Length Micron End Fiting Part Number
DOE CFYFYS9310 DOE CFYFZE9310
0.5 CODE 3 CFYFYS9340 0.5 CODE 3 CFYFZE9340
CODE 7 CFYFYS9350 CODE 7 CFYFZE9350
DOE CFYKYS9310 DOE CFYKZE9310
1 CODE 3 CFYKYS9340 1 CODE 3 CFYKZE9340
CODE 7 CFYKYS9350 CODE 7 CFYKZE9350
30"
DOE CFYOYS9310 DOE CFYOZE9310
9" 3/4 5 CODE 3 CFYOYS9340 5 CODE 3 CFYOZE9341
CODE 7 CFYOYS9350 CODE 7 CFYOZE9350
DOE CFYTYS9310 DOE CFYTZE9310
10 CODE 3 CFYTYS9340 10 CODE 3 CFYTZE9340
CODE 7 CFYTYS9350 CODE 7 CFYTZE9350
DOE CFZDYS9310
20 CODE 3 CFZDYS9340
CODE 7 CFZDYS9350
DOE CFYFZD9310 DOE CFYFZF9310
0.5 CODE 3 CFYFZD9340 0.5 CODE 3 CFYFZF9340
CODE 7 CFYFZD9350 CODE 7 CFYFZF9350
DOE CFYKZD9310 DOE CFYKZF9310
1 CODE 3 CFYKZD9340 1 CODE 3 CFYKZF9340
CODE 7 CFYKZD9350 CODE 7 CFYKZF9350
20" 40"
DOE CFYOZD9310 DOE CFYOZF9310
5 CODE 3 CFYOZD9340 5 CODE 3 CFYOZF9340
CODE 7 CFYOZD9350 CODE 7 CFYOZF9350
DOE CFYTZD9310 DOE CFYTZF9310
10 CODE 3 CFYTZD9340 10 CODE 3 CFYTZF9340
CODE 7 CFYTZD9350 CODE 7 CFYTZF9350
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /FILOTM Spun-HP/AQF118_EN_V1.3
Performance
μm
μm
μ
45
0.2
0.1
100
0.
Differential Pressure (psid)
Differential Pressure (mbar)
50
0 10 l/min 20 l/min
Cleaning and Sanitisation FILOTM Mem cartridge can be autoclaved up to 10 times up to 130°C or steam sterilised up to 130°C
Ordering Information
FILOTM Mem-P (Pharmaceutical applications) FILOTM Mem-E (Electronic applications)
Length Micron End Fiting Part Number Length Micron End Fiting Part Number
DOE CFYCYT9410 DOE CFYBYT9 410
CODE 3 CFYCYT9 440 0.1 CODE 3 CFYBYT9 440
0.2
CODE 7 CFYCYT9 451 CODE 7 CFYBYT9 450
10"
CODE 9 CFYCYT9 46 0 DOE CFYCYT9 411
10"
DOE CFYEYT9 410 0.2 CODE 3 CFYCYT9 441
CODE 3 CFYEYT9 440 CODE 7 CFYCYT9 452
0.45
CODE 7 CFYEYT9 450
CODE 9 CFYEYT9 46 0 DOE CFYBZD9 410
0.1 CODE 3 CFYBZD9 444
DOE CFYCZD9410 CODE 7 CFYBZD9 450
20"
CODE 3 CFYCZD9 440 DOE CFYCZD9 411
0.2
CODE 7 CFYCZD9 451 0.2 CODE 3 CFYCZD9 441
CODE 9 CFYCZD9 46 0 CODE 7 CFYCZD9 452
20"
DOE CFYEZD9 410
CODE 3 CFYEZD9 440 DOE CFYBZE9 410
0.45
CODE 7 CFYEZD9 450 0.1 CODE 3 CFYBZE9 440
CODE 9 CFYEZD9 46 0 CODE 7 CFYBZE9 450
30"
DOE CFYCZE9 411
DOE CFYCZE9 410 0.2 CODE 3 CFYCZE9 441
CODE 3 CFYCZE9 440 CODE 7 CFYCZE9 451
0.2
CODE 7 CFYCZE9 450
CODE 9 CFYCZE9 46 0
30"
DOE CFYEZE9 411
CODE 3 CFYEZE9 440
0.45
CODE 7 CFYEZE9 450
CODE 9 CFYEZE9 46 0
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /FILOTM Mem/AQF119_EN_V1.3
Part Number Nominal Area Permeate Flow Rate Minimum Salt Rejection
m² m3/d (usgpd) (%)
Maximum Feed Flow Dimensions inches (mm) Weight. Permeate tube length
Part Number inches (mm)
m3/hr (usgpm) kg (lbs)
A B C
MBROYL0700 1.4 (6) 21 (533) 2.4 (61) 0.75 (19.1) 0.9 (2) 1.2 (30.5)
Type
Configuration: Spiral Wound
Membrane Polymer: Composite Polyamide/Polysulphone
Test Conditions
500 ppm NaCl solution, 7 bar (100 psi), 25°C, pH 6 – 7, Permeate Recovery 10%.
Operating Limits*
Maximum Applied Pressure: 21 bar (300 psig)
A
Maximum Free Chlorine Concentration: < 0.1 ppm
Maximum Operating Temperature: 45°C
Feedwater pH Range: 3.0 – 10.0 Feed B
Maximum Feedwater Turbidity: 1.0 NTU Permeate
*Operating limits are for information only, actual operating conditions should be optimised to ensure best performance and
membrane life.
Notice: Minimum permeate flow for individual elements 15 % below listed flow. All membrane elements are supplied with a brine seal and o-rings. Elements are vacuum
sealed in a polyethylene bag containing less than 1.0% sodium metabisulphite and 10% propylene glycol solution and then packaged in a cardboard box.
Veolia Water Solutions & Technologies accept no responsibility for results obtained
by the application of this information or the safety or suitability of our products,
either alone or in combination with other products. Users are advised to make their
own tests to determine the safety and suitability of each product combination for
their own purposes.
Part Number Nominal Area Permeate Flow Rate Minimum Salt Rejection
m² m3/d (usgpd) (%)
Maximum Feed Flow Dimensions inches (mm) Weight. Permeate tube length
Part Number inches (mm)
m3/hr (usgpm) kg (lbs)
A B C
MBROYN0700 2.7 (12) 21 (533) 3.95 (100) 0.75 (19.1) 1.8 (4) 1.2 (30.5)
Type
Configuration: Spiral Wound
Membrane Polymer: Composite Polyamide/Polysulphone
Test Conditions
500 ppm NaCl solution, 7 bar (100 psi), 25°C, pH 6 – 7, Permeate Recovery 10%.
Operating Limits*
Maximum Applied Pressure: 21 bar (300 psig)
A
Maximum Free Chlorine Concentration: < 0.1 ppm
Maximum Operating Temperature: 45°C
Feedwater pH Range: 3.0 – 10.0 Feed B
Maximum Feedwater Turbidity: 1.0 NTU Permeate
*Operating limits are for information only, actual operating conditions should be optimised to ensure best performance and
membrane life.
Notice: Minimum permeate flow for individual elements 15 % below listed flow. All membrane elements are supplied with a brine seal and o-rings. Elements are vacuum
sealed in a polyethylene bag containing less than 1.0% sodium metabisulphite and 10% propylene glycol solution and then packaged in a cardboard box.
Veolia Water Solutions & Technologies accept no responsibility for results obtained
by the application of this information or the safety or suitability of our products,
either alone or in combination with other products. Users are advised to make their
own tests to determine the safety and suitability of each product combination for
their own purposes.
Maximum Feed Flow Dimensions inches (mm) Weight. Permeate tube length
Part Number inches (mm)
m3/hr (usgpm) kg (lbs)
A B C
MBROYN0704 3.6 (16) 40 (1016) 3.95 (100) 0.75 (19.1) 3.6 (8) 1.05 (26.7)
Type
Configuration: Spiral Wound
Membrane Polymer: Composite Polyamide/Polysulphone
Test Conditions
500 ppm NaCl solution, 7 bar (100 psi), 25°C, pH 6 – 7, Permeate Recovery 15%.
Operating Limits*
Maximum Applied Pressure: 42 bar (600 psig)
A
Maximum Free Chlorine Concentration: < 0.1 ppm
Maximum Operating Temperature: 45°C
Feedwater pH Range: 3.0 – 10.0 Feed B
Maximum Feedwater Turbidity: 1.0 NTU Permeate
*Operating limits are for information only, actual operating conditions should be optimised to ensure best performance and
membrane life.
Notice: Minimum permeate flow for individual elements 15 % below listed flow. All membrane elements are supplied with a brine seal and o-rings. Elements are vacuum
sealed in a polyethylene bag containing less than 1.0% sodium metabisulphite and 10% propylene glycol solution and then packaged in a cardboard box.
Veolia Water Solutions & Technologies accept no responsibility for results obtained
by the application of this information or the safety or suitability of our products,
either alone or in combination with other products. Users are advised to make their
own tests to determine the safety and suitability of each product combination for
their own purposes.
Type
Configuration: Spiral Wound
Membrane Polymer: Composite Polyamide/Polysulphone
Test Conditions
1500 ppm NaCl solution, 10.5 bar (150 psi), 25°C, pH 6 – 7, Permeate Recovery 15%.
Operating Limits*
Maximum Applied Pressure: 42 bar (600 psig)
A
Maximum Free Chlorine Concentration: < 0.1 ppm
Maximum Operating Temperature: 45°C
Feedwater pH Range: 3.0 – 10.0 Feed B
Maximum Feedwater Turbidity: 1.0 NTU Permeate
*Operating limits are for information only, actual operating conditions should be optimised to ensure best performance and
membrane life.
Notice: Minimum permeate flow for individual elements 15 % below listed flow. All membrane elements are supplied with a brine seal and o-rings. Elements are vacuum
sealed in a polyethylene bag containing less than 1.0% sodium metabisulphite and 10% propylene glycol solution and then packaged in a cardboard box.
Veolia Water Solutions & Technologies accept no responsibility for results obtained
by the application of this information or the safety or suitability of our products,
either alone or in combination with other products. Users are advised to make their
own tests to determine the safety and suitability of each product combination for
their own purposes.
Type
Configuration: Spiral Wound
Membrane Polymer: Composite Polyamide/Polysulphone
Test Conditions
1500 ppm NaCl solution, 10.5 bar (150 psi), 25°C, pH 6 – 7, Permeate Recovery 15%.
Operating Limits*
Maximum Applied Pressure: 42 bar (600 psig)
A
Maximum Free Chlorine Concentration: < 0.1 ppm
Maximum Operating Temperature: 45°C
Feedwater pH Range: 3.0 – 10.0 Feed B
Maximum Feedwater Turbidity: 1.0 NTU Permeate
*Operating limits are for information only, actual operating conditions should be optimised to ensure best performance and
membrane life.
Notice: Minimum permeate flow for individual elements 15 % below listed flow. All membrane elements are supplied with a brine seal and o-rings. Elements are vacuum
sealed in a polyethylene bag containing less than 1.0% sodium metabisulphite and 10% propylene glycol solution and then packaged in a cardboard box.
Veolia Water Solutions & Technologies accept no responsibility for results obtained
by the application of this information or the safety or suitability of our products,
either alone or in combination with other products. Users are advised to make their
own tests to determine the safety and suitability of each product combination for
their own purposes.
Specifications
Power supply 230 V or 24 V ± 10 % ; 50 - 60 Hz
Power consumption max. 30 VA
Degree of protection IP 65
Protection class I ; CE
Ambient temperature 10 - 45 °C
Water temperature 10 - 40 °C
Operating pressure 0.1 - 8 bar ; 10 4 - 8 x 10 5 Pa
Dimensions (W x H x D) 380 x 480 x 280 mm
Weight approx. 10.5 kg
Ordering Information
Model Measuring Parameter Part Number
VWS Monitor KH Carbonate Hardness IEPOHR30 10 8 7
VWS Monitor CLF Free Chlorine IEPOGU30 10 9 2
VWS Monitor CLT Total Chlorine IEPOGU30 10 9 1
VWS Monitor DUO Carbonate Hardness + Hardness IEPOGU30 10 8 9
VWS Monitor THCL Hardness + Total Chlorine IEPOGU30 10 9 0
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /VWS Monitor/AQF122_EN_V1.1
Specifications
Ordering Information
Model Measuring parameter Part Number
VWS Monitor TH Hardness IEPOHR30 10 8 8
In keeping with the progressive nature of the company, we reserve the right to amend details without notice.
VWS CATALOGUE /VWS Monitor/AQF121_EN_V1.1