Professional Documents
Culture Documents
240218_Lorong enggang_bath (R01)
240218_Lorong enggang_bath (R01)
150
200
±2080
±2080
X Y INSTRUCTION (INSTALL ONLY)
CH ±2630 SUPPLIED BY CLIENT
BATH
NEW FLOOR TILING TO BE SUPPLIED
BY CLIENT (INSTALL ONLY)
W
PLAN VIEW REFLECTIVE CEILING PLAN
BATH SCALE : 1: 25 BATH SCALE : 1: 25
NOTE:
- DIMENSION TO BE VERIFIED ON SITE AND FABRICATOR IS ADVISED
TO COUNTER CHECK MEASUREMENTS AT SITE PRIOR TO FABRICATION.
I HEREBY APPROVE THIS DRAWING & ACKNOWLEDGE THAT IT COMPLIES
WITH ALL THE REQUIREMENTS.
________________________________
NAME
CONSTRUCTION DRAWING
REVISION DESCRIPTION DATE DESIGN & BUILD CONTRACTOR:- PROJECT TITLE:- DRAWING TITLE:-
00 FOR APPROVAL 18/02/2024 INTERIOR RENOVATION WORKS FOR AINA'S MANSION BATH AREA
BATH AREA
AS DESIGN BUILD SDN. BHD. PLAN VIEW & RCP
18, JALAN CEMPERAI 13B/2 TAMAN PROJECT SITE:- SCALE: DRAWN BY :
NOTE
NO.10, LRG ENGGANG SATU, DATO KERAMAT AS SHOWN ALLY
* This drawing is the property of AS DESIGN BUILD SDN. BHD. (IP0589086-V) RASA UTAMA, 44200 RASA, DATE: CHECKED BY :
SELANGOR. TAMBAHAN, 54200 KUALA LUMPUR 18 FEB 2024
* We reserved the copyright to all our designs which cannot be reproduce (whether part or whole) or modified without first obtaining our written consent. SHAFIQ
* The drawing is subjected to modification of this design & measurement from time to time to suit construction purposes. TEL: +6011 3916 4218 JOB NO P24-001_AINA'S MANSION
REVISION NO
* Contractors must check all dimension on site before commencement of works. EMAIL: asdesignbuild23@gmail.com
DRAWING NO P24-001_AM/O1 000
* Any discrepancies must be reported immediately to the designer before proceeding.
SHEET_SIZE
1 2 2 1
CL CL
500
BY CLIENT (INSTALL ONLY) HT &
LOCATION TO BE VERIFIED ON SITE
2630
600
BY CLIENT (INSTALL ONLY) HT AND
±2293
LOCATION TO BE VERIFIED ON SITE
NEW BRICK WALL FOR NICHE
(SHOWER VOID) DESIGN NEW WATER TAP OUTLET HT &
POSITION TO CLIENT'S INSTRUCTION NEW HAND BIDET FITTINGS TO BE
(INSTALL ONLY) SUPPLIED BY CLIENT (INSTALL ONLY)
375 225
POSITIONING TO CLIENT'S
NEW VANITY CABINET C/W WB TO APPROVAL
1000
850
BE SUPPLIED BY CLIENT (INSTALL
ONLY) HT & POSITIONING TO NEW WC FITTINGS TO BE SUPPLIED
700
FFL FFL
2080 2080
ELEVATION X ELEVATION Y
BATH SCALE : 1: 30 BATH SCALE : 1: 30
A B B A
CL CL
NEW 10MM THK SHOWER SCREEN
WALL FINISHES IN TEXTURED PAINT
NEW EXHAUST FAN. LOCATION & (~HT 2100MM)MOUNT TO THE
BY CLIENT
HT TO BE ADJUSTED BASED ON SITE WALL/FLOOR TILES WHICHEVER
CONDITION SUIT SITE CONDITION
2630
10MM THK GLASS INSERT SHELF
600
________________________________
2350 2350
ELEVATION W ELEVATION Z NAME
* Contractors must check all dimension on site before commencement of works. EMAIL: asdesignbuild23@gmail.com
DRAWING NO P24-001_AM/O2 000
* Any discrepancies must be reported immediately to the designer before proceeding.
SHEET_SIZE