PROPOSED OPENING FOR NEW EXHAUST FAN

NEW HAND BIDET FITTINGS TO BE


SUPPLIED BY CLIENT (INSTALL ONLY)
POSITIONING TO CLIENT'S APPROVAL

NEW WC FITTINGS TO BE SUPPLIED


BY CLIENT (INSTALL ONLY)
A Z B A B
±1095 (to verify at site)
NEW 10MM THK SHOWER SCREEN
(~HT 2100MM)MOUNT TO THE WALL/
1 FLOOR TILES WHICHEVER SUIT SITE 1
CONDITION

150
200

EXISTING CEILING SLAB


NEW BRICK WALL FOR NICHE (SHOWER
VOID) DESIGN
±300 (to client's specifications)
900

NEW SHOWER FITTINGS TO BE SUPPLIED


WC BY CLIENT (INSTALL ONLY) HT &
LOCATION TO BE VERIFIED ON SITE
EXISTING FLOOR TRAP W NEW WATER
TAP OUTLET HT & POSITION TO CLIENT'S BATH EXISTING LIGHTING POINT ABV
CEILING SLAB. LIGHT FITTINGS TO BE

±2080

±2080
X Y INSTRUCTION (INSTALL ONLY)
CH ±2630 SUPPLIED BY CLIENT
BATH
NEW FLOOR TILING TO BE SUPPLIED
BY CLIENT (INSTALL ONLY)

NEW VANITY CABINET C/W WB TO BE


WB SUPPLIED BY CLIENT (INSTALL ONLY) NEW LIGHTING POINTS (2 NOS)
LOCATION TO BE VERIFIED ON SITE TO
NEW WALL MIRROR TO BE SUPPLIED BY CLIENT'S APPROVAL
DN 50
CLIENT (INSTALL ONLY) HT AND LOCATION
TO BE VERIFIED ON SITE
2 2
NEW BARN DOOR TO BE SUPPLIED
BY CLIENT (INSTALL ONLY) POSITION TO
900 200 BE VERIFIED ON SITE TO CLIENT'S 900 200
INSTRUCTION
±2350 ±2350

W
PLAN VIEW REFLECTIVE CEILING PLAN
BATH SCALE : 1: 25 BATH SCALE : 1: 25

NOTE:
- DIMENSION TO BE VERIFIED ON SITE AND FABRICATOR IS ADVISED
TO COUNTER CHECK MEASUREMENTS AT SITE PRIOR TO FABRICATION.
I HEREBY APPROVE THIS DRAWING & ACKNOWLEDGE THAT IT COMPLIES
WITH ALL THE REQUIREMENTS.

________________________________
NAME

CONSTRUCTION DRAWING
REVISION DESCRIPTION DATE DESIGN & BUILD CONTRACTOR:- PROJECT TITLE:- DRAWING TITLE:-
00 FOR APPROVAL 18/02/2024 INTERIOR RENOVATION WORKS FOR AINA'S MANSION BATH AREA
BATH AREA
AS DESIGN BUILD SDN. BHD. PLAN VIEW & RCP
18, JALAN CEMPERAI 13B/2 TAMAN PROJECT SITE:- SCALE: DRAWN BY :
NOTE
NO.10, LRG ENGGANG SATU, DATO KERAMAT AS SHOWN ALLY
* This drawing is the property of AS DESIGN BUILD SDN. BHD. (IP0589086-V) RASA UTAMA, 44200 RASA, DATE: CHECKED BY :
SELANGOR. TAMBAHAN, 54200 KUALA LUMPUR 18 FEB 2024
* We reserved the copyright to all our designs which cannot be reproduce (whether part or whole) or modified without first obtaining our written consent. SHAFIQ
* The drawing is subjected to modification of this design & measurement from time to time to suit construction purposes. TEL: +6011 3916 4218 JOB NO P24-001_AINA'S MANSION
REVISION NO

* Contractors must check all dimension on site before commencement of works. EMAIL: asdesignbuild23@gmail.com
DRAWING NO P24-001_AM/O1 000
* Any discrepancies must be reported immediately to the designer before proceeding.
SHEET_SIZE
1 2 2 1

CL CL

NEW BARN DOOR TO BE SUPPLIED NEW EXHAUST FAN. LOCATION &


BY CLIENT (INSTALL ONLY) HT TO BE ADJUSTED BASED ON SITE
CONDITION
WALL FINISHES IN TEXTURED PAINT
BY CLIENT
NEW SHOWER FITTINGS TO BE SUPPLIED

500
BY CLIENT (INSTALL ONLY) HT &
LOCATION TO BE VERIFIED ON SITE

NEW WALL MIRROR TO BE SUPPLIED


2630

2630
600
BY CLIENT (INSTALL ONLY) HT AND

±2293
LOCATION TO BE VERIFIED ON SITE
NEW BRICK WALL FOR NICHE
(SHOWER VOID) DESIGN NEW WATER TAP OUTLET HT &
POSITION TO CLIENT'S INSTRUCTION NEW HAND BIDET FITTINGS TO BE
(INSTALL ONLY) SUPPLIED BY CLIENT (INSTALL ONLY)
375 225
POSITIONING TO CLIENT'S
NEW VANITY CABINET C/W WB TO APPROVAL
1000

850
BE SUPPLIED BY CLIENT (INSTALL
ONLY) HT & POSITIONING TO NEW WC FITTINGS TO BE SUPPLIED
700

CLIENT'S INSTRUCTION BY CLIENT (INSTALL ONLY)

FFL FFL

2080 2080
ELEVATION X ELEVATION Y
BATH SCALE : 1: 30 BATH SCALE : 1: 30

A B B A

CL CL
NEW 10MM THK SHOWER SCREEN
WALL FINISHES IN TEXTURED PAINT
NEW EXHAUST FAN. LOCATION & (~HT 2100MM)MOUNT TO THE
BY CLIENT
HT TO BE ADJUSTED BASED ON SITE WALL/FLOOR TILES WHICHEVER
CONDITION SUIT SITE CONDITION

NEW BARN DOOR TO BE SUPPLIED


NEW SHOWER FITTINGS TO BE
1

BY CLIENT (INSTALL ONLY)


R15

WALL FINISHES IN TEXTURED PAINT SUPPLIED BY CLIENT (INSTALL ONLY)


BY CLIENT HT & LOCATION TO BE VERIFIED ON
SITE
NEW WALL MIRROR TO BE
SUPPLIED BY CLIENT (INSTALL ONLY)
2630

2630
10MM THK GLASS INSERT SHELF
600

HT AND LOCATION TO BE VERIFIED


BY CLIENT
ON SITE
NEW WC FITTINGS TO BE SUPPLIED
6MM THK METAL INLAY TRIMMING
BY CLIENT (INSTALL ONLY)
COLOR TO CLIENT'S REQUEST
300 NEW VANITY CABINET C/W WB TO
BE SUPPLIED BY CLIENT (INSTALL
NEW WATER TAP OUTLET HT & ONLY) HT & POSITIONING TO
NEW HAND BIDET FITTINGS TO BE CLIENT'S INSTRUCTION
SUPPLIED BY CLIENT (INSTALL ONLY) POSITION TO CLIENT'S INSTRUCTION
NOTE:
POSITIONING TO CLIENT'S APPROVAL (INSTALL ONLY)
- DIMENSION TO BE VERIFIED ON SITE AND FABRICATOR IS ADVISED
NEW WALL TILES TO BE SUPPLIED TO COUNTER CHECK MEASUREMENTS AT SITE PRIOR TO FABRICATION.
BY CLIENT (INSTALL ONLY) I HEREBY APPROVE THIS DRAWING & ACKNOWLEDGE THAT IT COMPLIES
FFL FFL WITH ALL THE REQUIREMENTS.

________________________________
2350 2350
ELEVATION W ELEVATION Z NAME

BATH SCALE : 1: 30 BATH SCALE : 1: 30


CONSTRUCTION DRAWING
REVISION DESCRIPTION DATE DESIGN & BUILD CONTRACTOR:- PROJECT TITLE:- DRAWING TITLE:-
00 FOR APPROVAL 18/02/2024 INTERIOR RENOVATION WORKS FOR AINA'S MANSION BATH AREA
AS DESIGN BUILD SDN. BHD. ELEVATIONS
18, JALAN CEMPERAI 13B/2 TAMAN PROJECT SITE:- SCALE: DRAWN BY :
NOTE
NO.10, LRG ENGGANG SATU, DATO KERAMAT AS SHOWN ALLY
* This drawing is the property of AS DESIGN BUILD SDN. BHD. (IP0589086-V) RASA UTAMA, 44200 RASA, DATE: CHECKED BY :
SELANGOR. TAMBAHAN, 54200 KUALA LUMPUR 18 FEB 2024
* We reserved the copyright to all our designs which cannot be reproduce (whether part or whole) or modified without first obtaining our written consent. SHAFIQ
* The drawing is subjected to modification of this design & measurement from time to time to suit construction purposes. TEL: +6011 3916 4218 JOB NO P24-001_AINA'S MANSION
REVISION NO

* Contractors must check all dimension on site before commencement of works. EMAIL: asdesignbuild23@gmail.com
DRAWING NO P24-001_AM/O2 000