SI-AQ VOC
Handheld TVOCs Monitor for Air Quality
Analysis in Industrial Safety, Environmental,
Laboratories and More

Accurate / Reliable / Robust / Fast


• Dynamic PID TVOC Sensor: • Large Internal Memory (2,000 Tests)
0 - 20,000 ppb or 0 - 200 ppm • Protective Magnetic Rubber Boot
• Temp., %RH, & Barometric • Optional Wireless Printer
Pressure Included • Optional Handheld Probe
• Real-Time Data Logging
• Active Internal Sampling Pump

Select Up to 3 Gases in Total:


Long Lasting Rechargeable
TVOCs, CO2, CO, Formaldehyde, NO2,
Battery & AC Charger
NO, O2, SO2, H2S

Si-AQ PC Software
Light Weight & Durable
& USB Cable
Parameter Sensor Range Resolution Accuracy All Si-AQ VOC Kits include:
0 - 20,000 ppb • Temperature, %RH, Wet Bulb, Dew Point
Low Range VOC 1 ppb
PID 0 - 46,000 µg/m³ ±10 % rdg ±20 ppb • Barometric Pressure
1 µg/m³
OR • PC Software & USB Cable
1 ppm • Real-Time Continuous Data Logging
PID 0 - 200 ppm ±10 % rdg ±2 ppm
High Range VOC 1 mg/m³ • Bluetooth® Connectivity
0 - 460 mg/m³
• Protective Carrying Case
Relative Humidity Capacitive 5 - 95 % 0.1 % ±2 % RH
• Continuous Active Internal Sampling Pump
• Long Lasting Battery & AC Charger
-40 to 257 °F 0.1 °F ±0.4 °F (32 - 140 °F)
Ambient Temperature Pt100 • Factory Calibration Certificate
-40 to 125 °C 0.1 °C ±0.4 °C (0 - 60 °C)
• Quick Start Guide
Piezoresis-
Barometric Pressure 260 to 1,260 mbar 1 mbar ±2 mbar
tive
Piezoresis- -40 inH2O to 40 inH2O 0.1 inH2O
Differential Pressure* ±1 % rdg
tive -100 mbar to 100 mbar 0.1 mbar
Optional Accessories
0 - 2,000 °F 1 °F 5 °F / 3 °C
Temperature Type K T1 Tc K
0 - 1,100 °C 1 °C or 2 % rdg
0 - 300 ft/sec 1 ft/sec
Air Velocity Calculated -

FT_EN – Si-AQ VOC – 12/10/2020 – Non-contractual document – We reserve the right to modify the characteristics of our products without prior notice.
0 - 91 m/s 1 m/s

Electromagnetic Com-
EN 61326-1, Portable Equipment
patibility

Sampling Probe
(Si-AQ Probe with Hose)
Si-AQ VOC Ordering Code
Example: Part #: VOC - Si-AQ VOC Cell (20,000 ppb) - Si-AQ CH2O Cell
(0 - 10 ppm) - Si-AQ CO2 Sensor (5000 ppm) = Low Range VOC, CH2O & CO2
Parameter Sensor Range Resolution
Si-AQ VOC Cell (20,000 ppb) 0 - 20,000 ppb
PID
Low Range VOC 0 - 46,000 µg/m³
Select Your
VOC Range
Si-AQ VOC Cell (200 ppm) 0 - 200 ppm Zero Filter for Calibration
High Range VOC
PID
0 - 460 mg/m³ Accuracy
(Si-AQ VOC Zero Filter)
Si-AQ CO2 Sensor (5000 ppm)
NDIR 0 - 5,000 ppm 1 ppm ±2 % rdg ±10 ppm
Carbon Dioxide (CO2)¹

Si-AQ CO Cell (0 - 200 ppm)


EC² 0 - 200 ppm 0.1 ppm ±4 % rdg ±0.5 ppm
Carbon Monoxide (CO)¹

Si-AQ CH2O Cell (0 - 10 ppm)


EC² 0 - 10,000 ppb 1 ppb ±5 % rdg ±50 ppb
Formaldehyde (CH2O)3,4
Optional
Gas Sensor Si-AQ H2S Cell (0 - 100 ppm) Bluetooth® Printer
EC² 0 - 100 ppm 1 ppm ±4 % rdg ±0.5 ppm
Hydrogen Sulfide (H2S)¹ (Si-AQ Bluetooth® Printer)
Upgrades

Si-AQ NO2 Cell (0 - 20 ppm)


(Choose Up EC² 0 - 20 ppm 0.1 ppm ±4 % rdg ±0.5 ppm
Nitrogen Dioxide (NO2)¹
to Any 2)
Si-AQ O2 Cell (0 - 25 %)
EC² 0 - 25 % 0.1 % ±0.1 % vol rdg
Oxygen (O2)

Si-AQ SO2 Cell (0 - 20 ppm)


EC² 0 - 20 ppm 0.1 ppm ±4 % rdg ±0.5 ppm
Sulfur Dioxide (SO2)¹

Moisture Exchange
Si-AQ NO Cell (0 - 250 ppm)
EC² 0 - 250 ppm 0.1 ppm ±4 % rdg ±0.5 ppm Tube for Calibration
Nitric Oxide (NO)¹
(Si-AQ Moisture Exchange)
1
Other ranges are available upon request
2
Electrochemical
3
Accuracy based on laboratory conditions
4
This sensor may have interference from H2, CO, H2S and other reducing gases such as alcohols
* Requires connection accessories, flexible tubes and connections available as option in the Si-AQ Kit Press. Diff.