Applicator Sizing - Condensed (Flow)

Project
Project
C.Project No.
Customer:
TAG ---
Timestamp ---
Review number ---
Sales order number
Contact person
eMail:
Phone
Fax

General Parameters Operating Conditions


Fluid 0 Dummy-Liquid (Water) based on SP minimum nominal maximum
State Liquid Requested Flow 100 600 1 000 kg/h
Character Clean 0.101165 0.60988 1.02129 m3/h
Abrasiveness Not abrasive Pressure 1.0062 1.5161 2.0259 kg/cm2_g
Fluid Group (PED) Dangerous Fluid (Fluid group 1) Temperature 40 50 60 °C
Fluid type Newtonian Density 988.49 983.8 979.16 kg/m3
Atmospheric Pressure 1.0133 bar_a Viscosity 0.67392 0.56347 0.47621 cP
Standard EN/DIN/ISO Vapor Pressure 0.0676 0.1156 0.1905 kg/cm2_a
Design pressure 1.0062 2.0259 kg/cm2_g
(min/max)
Design temp. (min/ 40 60 °C
max)

Flowmeter Sizing and Calculated Results


Flowmeter Promass F 300 Generation: 3 / minimum nominal maximum
Model: 1 Requested Flow 100 600 1 000 kg/h
Flow Principle Coriolis (Promass) Velocity 0.559 3.37 5.644 m/s
Extended Order Code 8F3B08-**********SAD2SA**+DC Sensor velocity 0.625 3.768 6.31 m/s
Meter Size DN 8 Pressure loss 0.01 0.14 0.34 kg/cm2
Material (sensor) * SS 1.4539 / 904L Measurement error 0.1 0.1 0.1 %
Process connection* PN40, 1.4404/316/316L, Flansch EN1092-1-B1 Mass***
Flange Reynolds No. 4 905 35 197 69 411
Operating range min. 0 0 0 kg/h
Operating range max. 2 000 2 000 2 000 kg/h Warning(s)
PED category ** : In observance of the selected process
conditions and medium, Applicator categorizes
this application as PED Art.4.3. Applicator
Notice(s)
suggests an instrument without PED option. 1. This is the smallest diameter of this sensor. You could also try to use the
flowmeter selection button to find other suitable sensors for your application.
*The user is responsible for the selection of process-wetted materials
in view of their corrosion resistance. Endress+Hauser makes no Message(s)
guarantees and assumes no liability for the corrosion resistance of the
materials selected here for the application described above.
** The PED category is an Endress+Hauser recommendation and
depends on the fluid category, process data as well from the max.
permissible pressure of the selected pressure rating.The fluids of the
Applicator data base are classified to 67/548/EWG.
***For error calculation, the specified reference conditions for the
calibration of the flowmeter according to ISO/IEC 17025 apply. Further
information in technical documentation.

Print date: 10.07.2024 08:47 AM -1/2-


Applicator®: 11.18.01 / 26.11.22

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data can be found in the corresponding Operating Instruction
(BA) and Technical Information (TI).
Applicator Sizing - Flow
Project :
Customer: C.Project No.:
Contact person: Phone: Fax:
eMail:

TAG : ---
Timestamp: --- Review number: ---
Sales order number:

Fluid properties sheet


Fluid
Fluid name 0 Dummy-Liquid (Water) based on SP State Liquid
Chemical formula Calculation standard Supporting Points

Fluid description
Solid content 0 Vol%
Medium character Clean
Abrasiveness Not abrasive
Conductivity more than 50 µS/cm
Fluid group (PED) Dangerous Fluid (Fluid group 1)
Fluid type Newtonian

Basic fluid parameters


Tc (Critical temperature) 374.1 °C Tm (Melting point) 0.04 °C
Pc (Critical pressure) 225.562 kg/cm2 Tb (Boiling point) 100 °C
Heating value 0 kWh/Nm3
Temperature / Viscosity Temperature / Density
Temperature Viscosity Temperature Density
1 20 °C 1 cP 1 20 °C 998 kg/m3
2 80 °C 0.35 cP 2 80 °C 970 kg/m3
Temperature / Heat capacity
Temperature Thermal capacity
1 0 °C 4.215 kJ/(kg*K)
2 50 °C 4.177 kJ/(kg*K)
3 100 °C 4.215 kJ/(kg*K)

Calculated results
Density nom. 983.8 kg/m3 Pressure nom. 1.5161 kg/cm2_g
Viscosity nom. 0.56347 cP Temperature nom. 50 °C
Sound velocity nom. 1 549 m/s
Vapor pressure nom. 0.1156 kg/cm2_a
Thermal expansion coeff. Beta P 0.0005
Viscosity coefficient AL -6.17925
Viscosity coefficient BL 1 811.51

Reference values: Normal conditions (SI): Standard conditions (US):


Atmospheric pressure 1.0133 bar_a Atmospheric pressure 1.0133 bar_a

Print date: 10.07.2024 08:47 AM -2/2-


Applicator®: 11.18.01 / 26.11.22

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors
and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A
change in these parameters could lead to different results. Mandatory data can be found in the corresponding Operating Instruction
(BA) and Technical Information (TI).

You might also like