TRFM-21K Series
Fetal Monitor (CTG Machine)
10.4 inches
TRFM-21K series Fetal Monitor

Products
TRFM-21K Series high-tech fetal monitors, offer a reliable,
high-performance solution for fetal monitoring needs in the clinic
and hospital, from pre-natal check-ups to antepartum monitoring
of high-risk pregnancies. Mars K Series is your best partner from
antepartum through intrapartum till delivery.

Features: 12-Crystal 1 MHz waterproof transducer

 Newly advanced A8 main board with Linux OS, more stable and safe,
the calculating is 4 times faster than traditional products Fetal Acoustic Stimulator (FASt)
 Folded 10.4 inches high-brightness screen TFT LED, touch screen (optional) The optional Fetal Acoustic Stimulator uses low

 12-crystal pulse doppler transducer (waterproof probes for option) frequency vibro-acoustic stimuli (VAS) to “wake”

 Supporting operation with keyboard or mouse (optional) the fetus, increasing the efficiency of antepartum
testing and improving retest consistency. VAS
 Large capacity storage space, 8640 hours memory for fetal traces
 Support medical history search by patient ID, name and mobile number indicated with a musical

 FHR signal quality indicator helps optimize the probe position


 Event Marker makes it easy to annotate perceived fetal movements (FM)
or other events on the strip chart
 Fetal Movement Profile (FMP) detects and automatically records gross
fetal body movements
 Heart rate offset mode allowing you to offset FHR2 ± 5~30BPM.
 Cross-Channel Verification (CCV) provide visual and audible indication when
it automated detects synchronous fetal or maternal heart rate/ pulse rate
signals, indicating that you may be monitoring duplicate signals
 Fetal heart rate alarm provides both audible and visual alerts if the heart rate
is outside of the user-defined high/low range.
 Easy-to-load Z-fold paper stacks itself neatly upon exiting the recorder,
facilitating easy storage
 Optional build-in wireless network card, supporting wired or wireless connection
to the central monitoring station
 Support HL7 (Health Level Seven, optional)
 Optional Fischer Non-Stress Test (NST) report software allows interpretation of fetal heart
Rate and TOCO traces, and generates a printed report automatically for a reassuring NST
TRFM-21K Series Fetal Monitor Specification

Dimension and Weight - Accuracy: ±1 bpm


2
- Dimension: 320mm*260mm*80mm - Intensity: <3 mW/ cm

- Weight: 2.8kg(excluding accessories) - Ultrasound frequency : 1MHz±3%

Power Supply - Resolution: 1 bpm

- Adapter: Output 9VDC, 5A TOCO


- Voltage:AC100~240V, 50/60HZ - Measurement method: Strain gauge sensor element

Display - Measure range : 0 ~ 100 units

- 10.4" color LED (0-135° rotation) - Resolution: 1 unit

- Resolution:800*600 pixels - Nonlinear deviation : ≤±8%

Battery (Built-in) - Baseline setting : 0,5,10,15, 20 can be selected

- Type: Rechargeable lithium battery 7.4V/2200mAh - Auto offset correction: 3 second after connecting the transducer

- Charge Cycle: ≥500 times - Auto zero adjust : TOCO value is set to zero negative

- Working time: 2 hours (larger battery for 4-5 hrs) following a negative Measure value for 5 seconds

Recorder (Built-in) Fetal Movement Recording


- Method: Thermal printer - Automatic fetal movement (AFM): pulsed doppler ultrasound

- Paper: Z-fold, thermosensitive - Automatic fetal movement autograph

- Paper width: 112 mm(4.41 in) - Manual fetal movement marker (MFM)

- Printing speed: 1/2/3cm/min SpO₂


- Trace: Max. 4 tracks - Measurement Range: 0 ~ 100 %

- Recording way: Real-time Recording, - Resolution: 1 %

Review Printing - Accuracy: 70% ~ 100%, ±2% normal

Alarm ±3 % motion or low perfusion

- Level: Low, medium and high Unspecified less than 70%

- Indication: Auditory, Visual, Delay of FHR Alarm PR


Input device - Range: 30~250bpm

- Touch screen (option) - Accuracy: ±2% or ±2 bpm, whichever is greater

- Keypad input(Standard) - Resolution: 1bpm

- Mouse/ Keyboard input (option) Maternal NIBP(MNIBP)


System Output & Extensible Interface - Method: Oscillometric

- Ethernet Network: 1 standard RJ45 socket - Measure mode Manual, Auto, STAT

- USB Port : 1 - Measure Interval in AUTO Mode 1~480 min

Trend & Reviewing: - STAT mode cycle time: Keep 5 minutes, at 5 seconds interval

- Cardiotocography (CTG): - Measure and Alarm Range :

Waveform Review: 8640 hours Systolic: 40 ~ 270 mmHg

- Vital Signs: Diastolic: 10~210 mmHg

Trend: 2160 hours Mean: 20~230 mmHg

Waveform Review: 2 hours - Static pressure accuracy ±3mmHg

NIBP Review: 2000 groups - Resolution 1mmHg

- Alarm Review: 2000 groups - Accuracy: Maximum Mean error ±5mmHg

Safety: Maximum Standard deviation 8mmHg

- IEC60601-1 Approved, CE marking according to MDD93/42/EEC - Overpressure Protection: Dual protection via software & hardware

- With reference to RoHS Directive 2011/65/EU recasting NST Report (Option)


Performance: - Based on Fischer Evaluation Method (monitoring time≥20 Min)

Ultrasound(FHR) - Automatic Score Result: Sore:8-10 (Excellent)

- Transducer type : 12-Crystal ultrasound transducer Sore:5-7 (Suspicious)

- Measure method: Wide beam pulse doppler Score:≤4 ( Fetus Hypoxia)

- FHR Measurement range: 30 to 240 bpm (US Standard)

50 to 210 bpm (Europe Standard) * Specifications subject to change without prior notice.
TRFM-21K Series Fetal Monitor Specification

Configuration

Maternal Advanced
Feature Fetal parameter Auxiliary device
parameter Fischer

Fetal Stimulator/ NST Report


Touch Screen/
Waterproof Probe/ (Fetal Health
Signal Keyboard /
Table Legend Single Dual AFM/ Wall Mount/ Report)
TOCO Overlap NIBP, SpO2, PR Lithium battery Mouse/
FHR FHR MFM Trolley/
Alarm Central Monitoring System
Bag
( Wired or Wireless)

TRFM-21KB √ √ √ √ √ × √ Opt Opt Opt

TRFM-21KD √ √ √ √ √ √ √ Opt Opt Opt