W2
Load Description
in kg/m2
UDL = 1675X0.4=670KG
BENDING MOMENT (BM) =Ux L2/8
BM 1 = 670X(1.2)^2/8=120.6 Kg.m
Check for Zxx= BMx100/permissible stress
= (120.6x100)/1100 = 10.96 <33cm3 Hence safe
Detail of Cuplock
1. Outer Diameter of Pipe = 48mm.
2. Thickness of Pipe = Verticals 3.2mm
3. Unbraced Length = 1000 mm.
4. As per IS 1161:1998 for Pipe having Outer Diameter of 48mm
Thickness is 3.2 mm
Crossectional Area is 4.53 cm2
Radius of Gyration is 1.59 cm.
Grid of Cuplock Proposed is 0.9 x 1.2 m , therefore load on individual leg of cup lock=
Self-load of Upper basement beam= 1675x 1.2x.9 1809 Kg
Therefore Permissible Axial Stress in Compression as per IS 806 1968 is 970 kgf/cm2.
Depth of DROP
LOAD TYPE concrete dencity PANEL Load/m2 UNIT
Concrete Load 2500 0.4 1000 kg/m2
Live load 125 kg/m2
False work load 50 kg/m2
TOTAL LOAD ON CUPLOCK 1175 kg/m2
Drop Panel Load on Individual leg for 1.2 m x 0.9 m Grid = 1269 Kgs.<2992kgs Hence safe
FOR SLAB
DEPTH 250MM
Grid of Cuplock Proposed is 1.2 x 1.8 m , therefore load on individual leg of cup =
( Self load of Upper basement SLAB)800 x1.2 x 1.8 = 1728KGS
Drop Panel Load on Individual leg for 1.2 m x 1.8 m Grid = 1728 Kgs.<2992kgs Hence
safe