Data sheet

Customer item no.:


Communication dated: 22/03/2023 Number: ES 8002315056
Doc. no.: Quick quote Item no.: 300
Quantity: 8 Date: 22/03/2023
Page: 1 / 7

RDLO 350-850 A1 SC G F Version no.: 1

Operating data
Requested flow rate 1667.00 m³/h Actual flow rate 1667.15 m³/h
Requested developed head 196.00 m Actual developed head 196.04 m
Pumped medium Water Efficiency 80.4 %
Clean water Power absorbed 1105.53 kW
Pumped medium details Not containing chemical and Pump speed of rotation 1492 rpm
mechanical substances which NPSH 3% 4.19 m
affect the materials NPSH required 7.13 m
Max. ambient air temperature 20.0 °C Discharge press. 19.19 bar.g
Min. ambient air temperature 20.0 °C
Fluid temperature 20.0 °C

Fluid density 998 kg/m³ Operating pressure (for 21.35 bar.g


Fluid viscosity 1.00 mm²/s indicated duty conditions)
Suction pressure max. 0.00 bar.g Shutoff head 218.16 m
Mass flow rate 462.17 kg/s Min. allow. flow for continuous 1046.54 m³/h
Max. power on curve 1407.32 kW stable operation
Max. allow. mass flow 830.40 kg/s Min. allow. mass flow for 290.12 kg/s
continuous stable operation
Design Single system 1 x 100 %
Performance test Yes

Design
Pump standard KSB axially split volute casing Impeller diameter 788.0 mm
pump Minimum impeller diameter 780.0 mm
Design Pump and motor on common Full impeller diameter 865.0 mm
Baseframe (3E) Direction of rotation from drive Clockwise
Orientation Horizontal Bearing seal driver side V ring
Enhanced Finish No Bearing type driver side Anti-friction bearings
Suction flange (AS) according EN 1092-2 / DN 500 / PN 25 Lubrication type driver side Grease
to 21A / FF Bearing sealing end side V ring
Discharge flange (AD) EN 1092-2 / DN 350 / PN 25 Bearing type end side Anti-friction bearings
according to 21A / FF Bearing lubrication end side Grease
Shaft seal Single acting mechanical seal Temperature measurement With
Shaft seal manufacturer KSB tapping
Shaft seal type 4RDB Temperature sensor PT100 Without
Mechanical Seal Form Balanced motor side
Material code BQ1EMG Vibration measurement With
Sealing plan E Single acting mechanical tapping
(external circulation) Color Ultramarine blue (RAL 5002)
Wear ring Casing wear ring KSB-blue
Wear ring type Standard design
Data sheet

Customer item no.:


Communication dated: 22/03/2023 Number: ES 8002315056
Doc. no.: Quick quote Item no.: 300
Quantity: 8 Date: 22/03/2023
Page: 2 / 7

RDLO 350-850 A1 SC G F Version no.: 1

Driver, accessories
Coupling Manufacturer Flender Baseplate size RD3E18
Coupling type Eupex N Motorside drill No
Nominal size 480
Scope of mounting parts: Baseframe for pump set – (Scope of
Coupling guard type Lightweight, not treadproof supply)
(ZN79) Anchor bolts M24x300 – (Scope of supply)
Guard size RDLEL600 Driver type Electric motor
Guard material Stainless steel Drive standard mech. IEC
Drive supplied by WEG
Baseplate type Pump and motor on common
Efficiency class Efficiency class IE3 acc. to
baseframe (3E) – light
IEC60034-30-1
execution
Motor speed 1492 rpm
Frequency 50 Hz
Rated voltage 11 KV
Rated power P2 1500.00 kW

Materials SC
Notes Bearing housing (350.1) HT250
General criteria for a water analysis: pH-value >= 6,5; chloride Bearing housing (350.2) HT250
content (Cl) <=250 mg/kg. Chlorine (Cl2) <=0.6 mg/kg. Shaft seal housing (441) QT400-15
Ammonium (NH4+) <= 2 mg/kg, free of H2S; Chlorine (Cl2) Casing wear ring (502) 30Cr13
<=0.6 mg/kg. Shaft protecting sleeve 06Cr19Ni10
Volute casing (102) QT400-15 (524.1)
Pump shaft (211) 20Cr13
Double-entry impeller (234) A890 GR 1B

Packaging
IPPC Standard ISPM 15 Yes Packaging for transport Ship
Packaging category W5 Outdoor storage at -40°C to +50°C for up to 3 months. Packet
Packaging for storage Indoor must be covered. No corrosion protection, only transport
protection.

Nameplates
Nameplates language International
Data sheet

Customer item no.:


Communication dated: 22/03/2023 Number: ES 8002315056
Doc. no.: Quick quote Item no.: 300
Quantity: 8 Date: 22/03/2023
Page: 3 / 7

RDLO 350-850 A1 SC G F Version no.: 1

Certifications

Hydraulic performance test Hydrostatic test (room temp.)


Acceptance standard ISO 9906 2B Range Complete pump with shaft
Quantity meas. points Q-H 7 seal
Certificate Inspection cert. 3.1 to EN Test pressure 27.76 bar.g
10204 Test time 30.0 min
Test participation Non-witnessed Certificate Inspection cert. 3.1 to EN
Quantity, non-witnessed 8 10204
Quantity, witnessed 0 Test participation Non-witnessed
Acoustic test Yes Quantity, non-witnessed 8
Vibration test Yes Quantity, witnessed 0
Bearing temperature test Yes
Final visual inspection
Balancing test Certificate Without
Balancing grade G 6,3 Test participation Non-witnessed
Part Impeller Quantity, non-witnessed 8
Certificate Without Quantity, witnessed 0
Test participation Non-witnessed
Quantity, non-witnessed 8 Material certificates: Volute casing (102)
Quantity, witnessed 0 Certificate Test report 2.2 to EN 10204

Material certificates: Pump shaft (211)


Certificate Test report 2.2 to EN 10204

Material certificates: Double-entry impeller (234)


Certificate Test report 2.2 to EN 10204

Order documentation
The following documents will be supplied with the order: QCP (quality control plan)
Technical data sheet Inspection reports/ certificates
Auxiliary connection plan General arrangement drawing
Material certificates Operating manual
Performance curve Languages English
Performance curve

Customer item no.:


Communication dated: 22/03/2023 Number: ES 8002315056
Doc. no.: Quick quote Item no.:300
Quantity: 8 Date: 22/03/2023
Page: 4 / 7

RDLO 350-850 A1 SC G F Version no.: 1

300
Qmin

[m]
Total developed head

Qmin
Qmin

200

ø865.0/A01

ø788.0/A01
ø780.0/A01

100
0 500 [m³/h] 1000 1500 2000 2500 3000 3500
16
NPSHR
[m] NPSH 3%

10
NPSH

2
0 500 [m³/h] 1000 1500 2000 2500 3000 3500
Efficiency

50

[%]

0
0 500 [m³/h] 1000 1500 2000 2500 3000 3500
1600

[kW ]
Power Input

1000

200
0 500 [m³/h] 1000 1500 2000 2500 3000 3500
Flow
Curve data
Speed of rotation 1492 rpm Efficiency 80.4 %
Fluid density 998 kg/m³ Power absorbed 1105.53 kW
Viscosity 1.00 mm²/s NPSHR 7.13 m
Flow rate 1667.00 m³/h NPSH 3% 4.19 m
Requested flow rate 1667.00 m³/h Curve number K1387.39/1
Total developed head 196.00 m Effective impeller diameter 788.0 mm
Requested developed head 196.00 m Acceptance standard ISO 9906 2B
Installation plan

Customer item no.:


Communication dated: 22/03/2023 Number: ES 8002315056
Doc. no.: Quick quote Item no.:300
Quantity: 8 Date: 22/03/2023
Page: 5 / 7

RDLO 350-850 A1 SC G F Version no.: 1

C
650 1000 900 747 998 D

E F
650

575
DN1
AD AS
1000 G

DN2
H
S
35

I
B J
L
K

Pump Centre

O P Q R

Drawing is not to scale Dimensions in mm

Motor Connections
required but not scope of supply Suction flange (AS) according EN 1092-2 / DN 500 / PN 25
Motor size to 21A / FF
Pump power 1500 kW Discharge flange (AD) EN 1092-2 / DN 350 / PN 25
Number of poles 4 according to 21A / FF

Baseplate
Design Pump and motor on Coupling
common baseframe (3E) – Coupling manufacturer Flender
light execution Coupling type Eupex N
Size RD3E18 Coupling size 480
Material Steel ST Spacer 0.0 mm
Leakage drain baseplate Rp1, Without
(8B) Weight net
Baseplate drain piping Without Pump 3960 kg
execution Baseplate
Foundation bolts M24x300 Coupling
Coupling guard
Total
Installation plan

Customer item no.:


Communication dated: 22/03/2023 Number: ES 8002315056
Doc. no.: Quick quote Item no.:300
Quantity: 8 Date: 22/03/2023
Page: 6 / 7

RDLO 350-850 A1 SC G F Version no.: 1

Connect pipes without stress or strain! For auxiliary connections see


Notes for dimensions: separate drawing.
Drawing is not to scale and only exemplary. Weights and dimensions shown are not
binding. Binding arrangement drawing only on request and with submittal of binding
motor dimension sheet
Dimensions without tolerance indication - shaft height: DIN 747
Dimensions without tolerance indication - welded parts: ISO 13920 - B/F
Dimensions without tolerance indication - Cast parts: ISO 8062-3 - DCTG 11
Dimensions without tolerance indication - Flange position: ISO 8062-3 - DCTG 11
Dimensions without tolerance indication - Flanges: acc. to flange standard
Dimensions without tolerance indication - Keyway and key at coupling: DIN6885 -
sheet 1
Dimensions without tolerance indication - Shaft diameter at coupling: DIN 7154 - m6

General notes:
Piping must be connected free of stress. The pump must not be used as
support for the piping (The pump is not an anchor point for the piping). The
piping must be fixed in such a way that no forces, vibrations or the weight of
the piping is transferred to the pump. Restrictions for forces and moments on
suction and pressure nozzle must be considered. Connection by means of
unrestrained expansion joints is not permitted!!

Grout all holes for the foundation blocks completely with nonshrinking
concrete. Observe the required compressive strength class C25/30 of the
concrete in exposure class XC1 as per EN 206-1.
Quality Control Plan (QCP)

Customer item no.:


Communication dated: 22/03/2023 Number: ES 8002315056
Doc. no.: Quick quote Item no.:300
Quantity: 8 Date: 22/03/2023
Page: 7 / 7

RDLO 350-850 A1 SC G F Version no.: 1

Connections
1M.1 Pressure gauge connection G 1/2 Drilled and plugged.
1M.2 Pressure gauge connection G 1/2 Drilled and plugged.
6B.1 Pumped liquid drain G1 Drilled and plugged.
6B.2 Pumped liquid drain G1 Drilled and plugged.
6D Pumped liquid vent G1 Drilled and plugged.
8A Leakage drain G 3/4 Drilled
6D Sealing liquid outlet G1 Flexible pipe with four way connector
26M.1 SPM sensor connection (driver side) M8 Drilled and plugged.
26M.2 SPM sensor connection (non-driver M8 Drilled and plugged.
side)
4M.1 Temperature gauge connection G 1/2 Drilled and plugged.
(driven end)
4M.2 Temperature gauge connection (non G 1/2 Drilled and plugged.
driven end)