Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 1

© IOSL 2014 Aviation Fuel Quality Control, Assurance & Operations Manual |IndianOil Skytanking

IndianOil Skytanking Ltd


Location : S. No. :
Name of Document : AE / EL
Frequency : QUARTERLY Date :
Hydrant Dispenser / Refueller Number
S. No. Description

1 Check battery voltage for 12 V/24 V battery


2 Check battery electrolyte level. Top up with distilled water if required.
Are battery terminal connections firm. Apply petroleum jelly if
3 required.
Condition of battery bracket & cover, proper insulation (4mm) &
4 protection
5 Dynamo / alternator charging
6 Check operation of electrical isolating (main) switch
7 Check electrical connections free from corrosion and not loose
Check electrical wire in good condition, covered / passing through
8 and securely strapped
9 No electrical wire in the way of any moving linkages
10 Any damaged cable connections
11 No insulation joints are provided in the cable (use of single wire)
Check the fuse box and relay box correct rating of the fuses are
12 fitted
13 All fuse/junction boxes provided with closed cover
14 Any sign of overloading
15 Writing & conduit condition No hanging
16 Proper functioning of proximity switches
17 Proper functioning of solenoid switches
18 Check the earth connections from chassis and engine
19 Check the mounting of self starter motor and alternator
20 Condition of all cable, cable glands / fixing
21 Check the wind screen washer system, wiper blades
Check the operational panel located inside the cabin, fixing of the
22 enclosure, indication lamps and switch fixing
23 Instrumentation indication lamps and gauges in working condition
Check the condition of the deadman coiled cable fixing and
24 handswitch condition
25 Platform proximity switches mounting and bracket condition
26 Interlock system for vehicle movement functioning
27 Check operations of the pulse transmitter and its cable connection
28 Electric solenoid valves check for satisfactory operation
All connecting cable between automotive unit and trailer secured &
29 OK

Remarks

Signature of Maintenance Officer

Issued By Approved By Issue No. Revision No. Date of Issue PageMaintenance


No. In-Charge
QCM-IOSL DGCA, BLR 01 Nil 15-06-2014 Page 225 of 245