—] one PROJECT /NPOEKT: ARCTIC ING 27 APKTAK CIT 2 CNet ‘Now cy eh ‘QUALITY CONTROL FORM 1650-EFR 01H | OWNER / 3AKASUMK: LLC ARCTIC LNG 2/000 APKTMK Cnr 2 @OPMA KOHTPOSIA KAYECTBA ELECTRICAL HEAT TRACING SYSTEM PROJ. No. / Ne MPOEKTA: 078226 SH.1OF3 PRE-CLADDING HEATING CABLE INSTALLATION AND TESTING INSPECTION REPORT Srr.4 Waa. CVCTEMA SIIEKTPOOBOTPEBA 3 OTWETO MOHTAME. iA WCTIITAHMA SUBCONTRACTOR /CYENOAPANMK eel HATPEBATESIbHOFO KABENIA 0 WSONALI PJOE-MWP2A. ‘T2S5M-0431_ GENERAL INFORMATION / OBUJAR MHOOPMAYIAA “SYSTENT SUBSYSTEM CHCTEWAT TOCATION (MODULE T DECK] WECTONONOMEATE [HEATING CIRCUIT TAGN'T-WAEHTV@HEATPORNEIT }OnEHCTEMA woaynes nevcy -EOULETO KONTYPA 252-98 ‘rasa EHT2201668 | CABLE TYPE (SEE NOTE 3)TTAT KABETA (CM ASSOCIATED LINES RANCHES TAG NT WERT. [ASSOCIATED HIB/ S BONES TT-EONES Wi VNENT hrevat. 3) outer ConproxexHon nimi) Yer [MPAEHHOA COEN,/CIMIAACOSON | PAMBETE, KOPOBKA [a setr-necuancy TPES, KABENEN: auorerymprouyance 240-00-20028-01 “oo-243:HP200-N1 040, [3 power uivinncr orParmiEHan ooaibnaonto-00t patel 2243 HPaOO.NIO-1DE [2 PoLyweR iNsUL/c nommatePHoA vs0N, [G toneraL msuL.c amnePAnbHon nson| THEATING CABLE MANUFACTURER & CAT, N' 1] ASSOCIATED NGC-20 TAG W (FASPUGRGLEV WERT | ASSOCIATED RTD (PTIOW) TAG" Ui APPUCABLEY VATENT. a {Sr OTOBUTEs HAT PEBATENLHOF KAEENA he CONPRERMOFO NEC-20 (ECM NVMEHAVO}. PONPAXEHHOTO PATSKA. RTD (PTIOD) (ECT HOME® KATETOPM: Naan ;PHMEHIMO} WA. vent @xV2CT- THERTING CRBLES LENGTH fl UA [ REF. EGUIPUENT VENGOR OWE REV. WT [REF EAT LAYOUT ONG REV.W_CCETA HA CXEUY. IATPEB. KABENA (Mi) ‘CuIKA KA NEPTOK OSOPYROBAHAA ACTIONOMEH/R SMEKTPOOSOTPEBA M HOME PEBHSMM: ‘om jOCTABUANA H HOMEP PES. Sooonvrarsez000'-cr6-0002¢01 REV.0-01 | s6¥0.NVTB16820001.018-0003401 REV.01 TESTING EQUIPMENTS / OBOPYAOBAHME ANA MCnBITAHWA MANUFACTURER CALBRATONDUE een TSTOTOBMTETE SERIAL NUMBER’ cEPHAMDIA HOME? | SROTENEH GPOKATOBEPHA ECEER PRECIO REGGE PRECUIOONGT | VEHALYHS10, MBGOTAEZ] 3008/2002 TERT PecADoa CIniren PRESIDEN] FLUKE 1608 54010848 8/3022 PRE-CLADDING INSPECTION / KOHTPON fo M3ONAYMA \CCEPTED | REJECTED REMARKS DESCRIPTION / ONMCAHME score ee ee IFEATING CABLE INSTALLED ON THE RIGHT PIPE AS PER ISOMETRIC AND EHT INSTALLATION SORE aa , [STANDARDS DRAWING /HATPEBATENLHMDIM AGEN YCTAHOBIEN HATIPABHMSHON TPYEE | gy a ls GooTaeTeTevan ¢ AGOMETPHNECKM EPTOKOMH NEPTENOM CTARDAPTHEDE IKOMCTPYM/i GEKTPOOBOFPEBA 7 |CORREGT TYPE OF HEATING CABLE WRAPPED VATH THE CORRECT PITCH EPH TH 5 a JSENGTI HATPEBATENGHO"O KABEMIA YCTAHOBNEH C BEPHBM WIATOM [GLASS/ACUNINUM ADRESIVE TAPE OR SS TE-WRE FIRMLY TIGHTNED AGAINST PPE AS PER) «3 |SVENT RECOMMENDATION KnERLIASICR NEHTA Ma CTEMOBONONHA/ ATIOMAHIA HA & al |EAIioKtHan POBONORA Wa HEPHABEIOLIEA CTAIM PEIKO YCTAHOBIIEMA HA TPYBE 8 [GOoTBETCrev c PEKOMERGALIIAN NVENT i THEATER CABLE SUITABLY ATTACHED To PIPE. TANICOR VESSEL AS PER EHT INSTALLATION _[DETALS ORANG! HarPeaaTenstun KABE% noni O6PAGOM YCTAHOBIENHA ie a lrey6ePeserayane win cocvae 8 COOTBETCTSMM C UEPTEKOM CTAMBAPTHUK ONCTPYKLJAN STIEXTPOOEOFPEEA. THOTCOLD CONNECTION Kt, INSULATION RIT (EX20-7), JUNCTION AND END SEATS PROPERLY INSTALLED /KOMIMIEKT AVIA TOPAYETo-ONONHOTO CPALVIBAKINA, VaonALyan | — a leKanP), COFRMMMTENGMAR W HOFLEBAST SATO” BEPHO YCTAMOBMIENS| ‘COLDLEAD MAXIMUM LENGTH VERIFIED AS PER NOTE.8 COLD LEAD DRIP LOOP DONE AS PER NVENT RECOMMENDATION / MARC. AIVAHA XONOBML KOHLOB a SOOTBETCTEYET NMA 8/ XOMOAKE KOM FASEMLHEIX METEMs BAINOMHEHE 8 /OOTBETCTEMA C PEKOMENDALINAMM RENT N-GGHES AND S-EOKES NPE AND NUMBER PROPERLY INSTALLED ON PIPE, TANK OR VESSET] |SEeNore®)/PASSETBIL 1 CIMANCOBAR KOPOSXA AON OsPASOMYCTAHOBTENW | — a JHA TPYBE, PESEPBYAPE Wii COCYAE, Wx KOTWMECTBO BEPHOE (CM. PAM.) THERTING CABLE, HIB, T-BOXES, SOK AND CONNECTION COMPONENTS HAS NOT «| VISE DAMAGE / Ha HarpEBATENsHOM KABENE COEM. PASBETaN. CrINANCOBOM a et rosea nareeeateranin Sere” Mna anewehiAx CorsoerilOTCYTCra” HVE NOBPEKREHMA "ELECTRICAL TRACED” WARNING AND HAZARDOUS ARER [ABELS APPLIED SEE NOTE TO) » |nee@nPexnAioupre auakn“ocTOPOKHO SMlKTPOOEOTPES M OTMETH Os OnAcHON | — o JOKE VCTANOBNEHM (CM. NVM 10) [AS-SUILT MASTERS UP TO DATE AND AVAKABLE/ HCTIOMHWTENBHAR AOK/MEHTALAR 4 a JOeHoRreHAnaocTyTm WEY YOANN) ; PROJECT/MPOEKT, ARCTIC LNG 2/ APKTMK Chir 2 mamy = UNGls? YWovarct QUALITY CONTROL FORM. 1650-EFR 01H =| OWNER / 3AKASUMK: LLC ARCTIC LNG 2/000 APKTMK Clr 2 ‘©OPMA KOHTPONA KAUECTBA ELECTRICAL HEAT TRACING SYSTEM PROU, No, Ne POEKTA: 0793226 3.203 PRE-CLADDING HEATING CABLE INSTALLATION AND TESTING INSPECTION REPORT cre 2 M3, CICTEMA S/IEKTPOOBOTPEBA 7 OTYET O MOHTAXKE MMCNbITAHVIM SUBCONTRACTOR / CYBNOQPALMK: eee ‘TaseM. 0431 HATPEBATENHOr 0 KABENIA [10 M3O/IALWM PREGA NOTES /NPMMEMAHHA 4. DISCONNECT coi power abe rom Hu8 belo tstng/ PASFEJIAMVTE xonognil expen xa6ere ot een, opoBi arpanareri enw nee Henan 2 Contnuly Test= Ml and P shall be within acoplate ls of he maruacurr as per te x Label powspeaeroernecT— Mae. W AMBETODEA RSPR [ona Sure» apanonas nroronurenspcooreeerem co aura Ex 2. BesCindang Inatation es tnnce Tost eld work atuctons/ Veperanise cnporvarehin Horan A Mansi ~nerpy Ratt Ro NoneaL paboreN: > Saliregdatna ype: Meggers pstve lesa on both haatng conductors (epee) and Noalv led on bai /Cauopennupyoutics vex ontrTereni war" woraonuorpa Wa 60 nposonhicax eboct)w oTpwsrenoi rover" a oypave (pore) YES TA + Mlle’ Weggersportve las on ty Resting conductor (ogethe) ard nega oad on bah Bais C wispansoh ons onosarrenuut oaer woramuerpa Wa 10 nposow (aac) eTpyuBTonek TTA a cGonx open pone) YES/BA C) + ELiipe meggers leads betveen eistance hestng bus wre anaiNOSOh onset YoxTarT WeracuveTpA MexiyconpoTmareNHeN recut powogiae:YES/DA 0) 4. Te provortneatng cate conducter damage ad posse shoring, heating cable shoul ot be bont aes ts than 13mm ne outof plans croton at T= 10°C 1° Ppa npezorepaussun nopenaenin apsoseana rarpeesrencic acana nsswonx susie parpeearenene Habon He ewoRJoT CROPS © fagaycou weve ‘Sua apjsst Haypaenannn npa T= +10" «5. 'mimum bending radus fort cabs shel ot be oss han © tse he ouside cameo ofthe cal /Mymvanssh pace ama An xara uN, oor ne onion Gute wovoue 6 raya. aewerpoe bene 6. Mi cable shall not cross or everap ana shal be mirimum e 25 mun pat posi aon ¢ wepanvwod worRUNGH He AOmRN MePeEPeUFESTIR HN achawearacs w ore Gre met 25m (cP wate) 17. "Seenarge heating cal before srconnecing tom he Magoer/ CSpocsre vanprcawe ya vaypenaensvou ees 6: TRACE HEATING = Gold Lead maximum lengths STEKTPOOSOTPEB ~ wax rina voront Fron nepen orceanmenseu or weracuetp, ~Saatregaatoa vee as ais oa Tascl Cavcperrmovedinienrmnerviary.x1v, | WA | oy | | =piSsine Bobet) Soe Te mmcimseoh SMART i eee Careee a cures a acc ea enya - eet. cs |= MI Series (Mineral Insulated) types ¢ amnepansiom weonained El: Se ea ean) (ecco caters a 9. As perisometic drawings, cieut branches (29 EHT!300O0-A/8/..) shall be xminte to el respecte Tee Spice J8s befor stig 8 coreercramt c taowerpiacen voproai oe pyancase Gao wane, EMT! XOOGOCNIC..) afte Gu aamompesate ccooTeeTeTapeu pasbTan/ewnancoeeh fepootet go wena 10 zardous sea belo be instal blore fal goslaing meger test Ofoaravenneonacioh Sova Aor Bue YCTaNONNEND fo AND WMA weracuworpon necreweonau PRE-CLADDING TESTS / MCNbITAHME fo M3OnALMA INSULATION RESISTANCE (MEGGER) / CONPOTMBNEHME VSO/IAUMM (METAOMMETE) SONTINUITY / crOWHOCTE TEST VOLTAGE /VETBITAT, HATPREHME TE TPE Ten Tw 7B: TEMPERATURE TOWP. TEM: I SELEREGULATING / CAMOPETYN 2500 vee 2 power uurtneye orev Mowwocri 35004 peas 1 piseriesyc nnacta Moonmuen 2500 Va a8 ec 2 MISERIES/C ann, nSOMALMEH ‘ono va ACCEPTANCE CRITERIA/KPMTEPMTPVEMY: > 200 ACCEPTANCE CRITERIA/KPVTEPVAATIPMEMKM: _NA. TL Ma TEST /MCNITARNE RESULT/ PEaVMBTAT TEST/ WenITAHNE RESULT/ PESYNTAT conouctors conouctors: (6EENOTE3)/MPOBOAHHOA 59 co eemeei StS kosm wey suo. (eu nen ‘one ACCEPTABLEMPMHATO | YESINAL NoET ACCEPTABLEINPHHATO YESINA NomeET C1 AND POET OER ARCTIC LNT APR CPR AE EMA Snov eT ‘QUALITY CONTROL FORM 1650-EFR 01H | OWNER / SAKASUMK: LLC ARCTIC LNG 2/ 000 APKTMK Clr 2 OPMA KOHTPONIA KAYECTBA ELECTRICAL HEAT TRACING SYSTEM PROJ. No. / We TIPOEKTA: 0783226 SHOR PRE-CLADDING HEATING CABLE INSTALLATION AND TESTING INSPECTION REPORT falda LE CCTEMA SNEKTPOOBOTPEBA 1eE0FR OTH NF Ee eur REE SUBCONTRACTOR’ CyEnoAPRAMK: HATPEBATENSHOTO KABENA [0 MSONAUAA ipa TassMoss1_ [REMARKS / PUNCH LIST KOMMEHTAPIMM | REEKTHAA BEAOMOCTL CONFORNITY OF INSPECTION | NOATBEPAAEHME KOHTPONA {confi that al components ofthe element mentioned above and ther implementation are in complance withthe project requirements and specications. ‘This inspection form does nat diminish the responsibilty ofthe subcontractor, i applicable, to ensure the qual ofthe work performed. ‘Fi nonreepxaas, vo ace anewenTe: yrazaHHOn Sile EAM v ve NCROMNeHe COGTAETCTEYITTPEOORAHURM NpORKTA h TexNeeXHM TpeGONAM Jlanntan cbopsa Korrpons xavectsa He cnmmiaer oTeercrseHHOcTsc cyONoAe—inKa NO wAcTH YaveCTaa BunonWenHK aber, eck RpNMEHAN. fie) nronecrectyrosneo vcharano ree aanenon [mn Yuan xisteng ve alo en [iearcroren rowRinA MTCATAN omaawy —|TPERCTAaMTroGPAOA TERT [rar AGYGAZ - Qc LIU TIE JUN 220% a nope Lay Le, NS as su 2EY8 JU ZEYU 23 -03- 202 rosso] 23 -03- 2022

You might also like