Filter Types 34
FUME HOOD
GENERAL PURPOSE This unit is the most versatile fume hood available. While
packed with features, performance and convenience are the key
& ACID DIGESTION
values within this MEH series. Therefore, this model is suitable
FUME HOOD for various daily applications.
MEH 12 In addition, the MEH model are tested against the ASHRAE 110
(Method of Testing Performance of Laboratory Fume Hoods)
standards by SIRIM Malaysia to afford users with assurance of
MEH 15 the performance. The ASHRAE 110 standard is one of the latest
and most comprehensive methods for testing operator safety
level of fume hoods. In order to do that, this MEH series goes
MEH 18 through tests qualitatively and repeatably to see how well the
fume hoods contain the gases and vapours released in the work
zone.
MEH 24
Features
Proven to perform - ASHRAE 110 tested by third party
Stainless steel 304 flip open airfoil with spillage catchment
Effortless sash movement with chain and sprocket sash
system
Durable sash system – warranty up to 10 years
Durable, tough and chemical resistant fiber reinforced
polyester interior
Double sided smooth baffle for minimal flow resistance,
improving performance
Safety work zone indicator line as standard on epoxy worktop
Raised edge work surface for spill containment
FUME HOOD
Linear Material (Altenative) Phenolic Resin Laminates/ Polypropylene/ PVC/ Stainless Steel
Worktop Material (Alternative) Phenolic Resin Laminates/ Polypropylene/ PVC/ Stainless Steel
GENERAL PURPOSE A more economical and robustly designed fume hood for
general laboratory application. This unit is one of the most
FUME HOOD
common and basic fume hoods available in the market that
suits your laboratory need. This MEB model is suitable for
MEB 10 general lab application and can deal with various common acid
and solvents.
Hood Structure Electrogalvanised Steel with Oven Baked Epoxy Polyester coating
Base Cabinet Structure Electrogalvanised Steel with Oven Baked Epoxy Polyester coating
Internal Linear Material (Standard) Chemical Resistant Super White Fiber Reinforced Polyester
Linear Material (Altenative) Phenolic Resin Laminates/ Polypropylene/ PVC/ Stainless Steel
Worktop Material (Alternative) Phenolic Resin Laminates/ Polypropylene/ PVC/ Stainless Steel
HYDROFLUORIC Almost similar to its MEB series counterpart, this MEBF series
ACID DIGESTION is for hydrofluoric and acid digestion. While packed with
features, speciality and convenience are the key values for this
FUME HOOD MEBF series.
MEBF 15 Features
Clean and chemical resistance interior
The sash is made of polycarbonate material
MEBF 18 Durable chain & sprocket system for smooth sash movement
Modern Europe chemical resistant polypropylene centrifugal
fan
Flip open airfoil for easy cleaning of spillages
OP
OPTIONAL – Airflow alarm monitor to ensure user safety
FUME HOOD
Base Cabinet Structure Electrogalvanised Steel with Oven Baked Epoxy Polyester coating
Internal Linear Material (Standard) Chemical Resistant Super White Fiber Reinforced Polyester
Linear Material (Altenative) Phenolic Resin Laminates/ Polypropylene/ PVC/ Stainless Steel
Worktop Material (Alternative) Phenolic Resin Laminates/ Polypropylene/ PVC/ Stainless Steel
PERCHLORIC ACID This fume hood is a necessity when dealing with the highly
explosive and flammable perchloric acid. With an inbuilt wash
FUME HOOD WITH down system, integral work surfaces and drainage throughs, the
WASHDOWN fumes are prevented from accumulating potentially reactive
perchloric salts.
MPH 12
METHOD perchloric acid fume hood has a fully welded stainless
steel 316 inner linear material complete with a drain trough. This
MPH 15 unit is equipped with a washdown system that provides
thorough cleaning.
MPH 18
Features
Stainless Steel 316 for superior chemical resistance
Fully welded internal chamber to prevent water leaks
Washdown and trough system for cleaning of work chamber
Effortless sash movement with chain and sprocket sash
system
Durable sash system – warranty up to 10 years
FUME HOOD
Base Cabinet Structure Steel with Oven Baked Epoxy Polyester coating
RADIOISOTOPE Method MRX Radioisotope fume hoods are made to offer the
highest level of personnel and environment protection from
FUME HOOD
radio-chemical applications in laboratories. It ensures the quick
and effective removal of all hazardous radioactive fumes from
MRX 12 spillages, handling or storing from the work chamber.
MRX 15 Features
Stainless steel 304 linear as standard. Optional 316 as
upgrade available
MRX 18 Effortless sash movement with chain and sprocket sash
system
Seamless linear construction for easy cleaning and
maintenance
Fully integrated stainless steel worktop with optional welded
sink
Reinforced worksurface to withstand heavy loads
Optional filtration system
FUME HOOD
Internal Linear Material (Standard) Stainless Steel 304 /Stainless Steel 316 (Optional)
Worktop Material (Standard) Stainless Steel 304 /Stainless Steel 316 (Optional)
COMPACT GLASS The smallest fume hood in our range, the C780 fume hood is
designed to fit into any size cabins or labs. Utilising almost the
FUME HOOD
entire width of the hood, the C780 allows maximum workspace
for the users. With a an ergonomically angled flip open sash,
MEH C780
users can expect comfort and easy viewing when working with
this C780.
Features
Budget friendly
Small footprint for space constricted labs
Efficient work area, almost 98% is available for use
Viewable glass from both sides
Ergonomically angled front for easy viewing during use
Flip open sash for minimal maintenance
FUME HOOD
Length 780
Depth 600
Height 800
Internal Working Size (mm):
Length 750
Depth 570
Height 600
Mobile Support Frame Construction Hollow Steel Frame with Oven Baked Epoxy Polyester coating
Worktop Material (Alternative) Phenolic Resin Laminates/ Polypropylene/ PVC/ Stainless Steel
MOBILE DUCTLESS Mobile and highly functional ductless fume hood. Equipped with
NFX tested filtration system, our ductless fume hood comes
FUME HOOD
with high performance activated carbon filters designed to
remove chemical fumes effectively
DLF-12M
The ductless fume hoods from METHOD provide the user with a
secured workspace for the repetitive manipulations of small
DLF-15M chemicals quantities. The dangerous vapours are confined in
the enclosure, then are cleaned while entering the active
charcoal filter. Finally, dangerous vapours are rejected in the
DLF-18M
atmosphere without danger for the environment. Thus, the
user’s health is protected.
Features
NFX-211 tested ductless filtration system from Europe
Very low energy consumption, reducing operating cost
Ready to use and no ducting need
Mobile unit allows for flexibility and convenience
Ergonomic handtraps for optimal user protection
Large working space, almost full length of use
Highly efficient and silent fan operation
Audible and visual alarm to alert user of filter saturation and
low air flow
Convenient and easy to operate system
Electrical grommets on both sides to allow for easy cable
handling
Filter view window to indicate filter model and correct
placement of filter
FUME HOOD
Voltage 220-240 V
FUME HOOD
MINI DUCTLESS If you have a need for a compact ductless fume hood, this
FUME HOOD model may be an excellent choice for your application.
Features
Mobile and compact for flexibility and portability
Easy replacement of filters
Electrogalvanized steel main body for maximum durability
Double hinged sash mechanism allows a higher sash opening
FUME HOOD
Length 760
Depth 705
Height 1215
Hood Structure E.G Steel with Oven Baked Epoxy Polyester coating
DLF-SL005 Features
Mobile with lockable castors for maximum convenience and
safety
Low height design for placement in almost any room
Reduced failure of glass sash with a chain and sprocket
system
Designed with safety in mind with acoustic and visual alarm
to warn users of low suction
Inbuilt PVC fan to handle the widest range of corrosive
chemicals
Effective and honey-combed for low resistance activated
carbon filter
Specifically blended filters made to offer best filtration
dependent on you applications
Setup technical services such as water, waste and gas using
quick connection to docking stations when required
(Optional)
DLF-SL005
FUME HOOD
Model DLF-SL100V1
Length 1000
Depth 826
Height 1950
Base Cabinet Construction Electrogalvanised Steel with Oven Baked Epoxy Polyester Coating
Lighting Fluorescent
Controller Microprocessor LCD control and sensor with inbuilt alarm for low airflow
Voltage 220-240V
Model DLF-SL005
Length 250
Depth 117
Height 350
Features
To maintain a consistent fume hood face velocity by automating
the frequency inverter (separate product)
Ensuring fume hood is functioning at optimal face velocity at any
sash position
Has an inbuilt alarm to alert user during low flow and high flow
It contains various configurable functions, including prepurge,
postpurge and maintenance program
Features
To indicate the safe level of air flow in laboratory fume hoods
The LCD provides continous viewing of face velocity and will
warn users of unsafe conditions
An alarm will be activated when air flow falls below preset level
User friendly interface allows user to determine their preferred
level of face velocity depending on their requirements
28.0 90.0
Ø4.4
15.0
15V +
SENSOR POWERDC -
s/w
+
OUTPUT OUTPUT
+
147.0
+
0-10V 0-10V
CON.
117.0
RELAY INPUTS
F1 F2 F3 - 1
+
+
AUX.
2
-
+
3
OK
1
OUTPUT RELAYS
2
RS485
GND
D- 3
D+
15.0
84.0
DP 06 DP 08 DP 10 DP 12
Model DP 06 DP 08 DP 10 DP 12
ECO AIRSASH IV
Features
Automatically closing the sash when the operator is away from
the fume hood
Equipped with a safety sensor, it detects incoming presence or
obstruction and stops the sash from closing
FANS
SEAT 25
PT (Pa) PT (Pa)
1600
2000
1400 3440 • • • 1800
1200 • 1600 2,2 K W
3 KW
1000 2870 RPM • 1,1 K W 1400 2870 RPM • • •
•
• • 1,5 K W •
800 • 1200
0,75 K W
•
• 1000
600 2200 RPM
• • 2200 RPM • •
• 800 •
• •
400 • •
600
1720 RPM• •
• 1720 RPM • •
• •
300 • • •
• 400 •
1450 RPM • •
• •
0,37 K W •
200 1450 RPM
300 •
• •
0,25 K W • •
930 RPM • •
0,18 K W 200
• • • 180 • RE
100 • SU
160 S
• RE P RE
• SU 140 930 RPM • • •
• • IC
• ES A M
730 RPM PR 0,18 K W •
IC 120 • D YN
•
AM
•
• N 100
50
• DY
730 RPM• • •
• •
80 • Standard 50 Hz
40 Standard 50 Hz
• • 60 Hz
60 Hz
30 • 60 AMCA 210-85
AMCA 210-85 ISO 5801
ISO 5801 • •
•
M3/H 500 1000 1500 M3/H 500 1000 1500 2000 2500 3000 3500
CFM 294 588 883 CFM 294 588 883 1177 1472 1766 2060
SEAT 35
PT (Pa) PT (Pa)
7,5 K W
800 1720 RPM
• •
1500 • • • •
• •
• 5,5 K W
700 1400
• 1720 RPM•
600
1300 • • •
7,5 K W
1450 RPM • •
• • • •
1,1 K W • • 5,5 K W
500 1200
• 1610 RPM•
•
1100 RPM •
SU
•
• •
ES
• 500
PR
•
730 RPM
IC
• • • • • •
M
• •
400 930 RPM RE
NA
•
• • • SU
2,2 K W ES
DY
•
• PR
C
300 MI
• • NA
100 • • • • • • DY
730 RPM • • •
Standard 50 Hz 200 1,5 K W •
• Standard 50 Hz
80 60 Hz
60 Hz
• 100
AMCA 210-85
AMCA 210-85
60 ISO 5801
ISO 5801
0
M /H
3
500 1000 1500 2000 2500 3000 3500 4000 4500 5000 3
M /H 1000 2000 3000 4000 5000 6000 7000 8000 9000
CFM 294 588 883 1177 1472 1766 2060 2354 2648 2942 CFM 588 1177 1766 2354 2942 3531 4120 4708 5297
SEAT STORM 14
SEAT STORM 16
PS (Pa)
1400
•
STORM 16 1/3 2.2 3 1450 77.7 2850 rpm
, 0.37 kW
•
•
•
800 •
• •
•
•
600
•
2200 rpm
• • •
• •
•
•
400 • •
E
1720 rpm UR
•
• SS
• • • RE
• CP
• MI
1450 rpm
, 0.25 kW NA
• • • • • DY
•
200 • •
Standard 50 Hz
• •
PS (Pa) •
• 60 Hz
3500 •
Standard 50 Hz AMCA 210-85
•
ISO 5801
60 Hz •
•
3250 3
M /H 100 200 300 400 500 600 700
AMCA 210-85
3440 rpm ISO 5801 CFM 58 116 174 232 290 348 406
3000 • • • •
• • •
SEAT STORM 12
2750 •
2500
2250
2850 rpm,2,2 kW
• • • •
PS (Pa)
2000
• • • • 2250
Standard 50 Hz
1750
3440 rpm 60 Hz
•
1500 2000 • • AMCA 210-85
• ISO 5801
•
2200 rpm •
1250 • • • •
•
• • • • 1750 •
1000
•
1720 rpm
750 • • • • • • • • 1500
• 2850 rpm,1.1 kW
• • •
500 • •
• •
•
E
•SUR 1250 •
• PRES
250 MI C
DYNA •
• •
M3/H 500 1000 1500 2000 2500 3000 1000
CFM 290 580 870 1160 1450 1740
2200 rpm
• • • • • •
SEAT STORM 16 750 •
•
• •
1720 rpm
• • • • •
500 •
• • •
• •
RE •
SSU
250 PRE
• MI C
• DYNA
•
•
•
•
M3/H 200 400 600 800 1000 1200 1400
CFM 116 232 348 464 580 696 812
SEAT STORM 14
FANS
CHEMICAL RESISTANT
CENTRIFUGAL FAN
VSB 20
VSB 25
350
H
FC-FM 100 300
M
L
250
Pst=Pa
FC-FM 160 200
150
50
0
0 50 100 150 200 250 300
Q=m3/h
FC-FM 100
Model Phase kW g/min rpm dB(A)
200
150
100
50
0
0 100 200 300 400 500 600 700 800
Q=m3/h
FC-FM 160
Performance Curve
350
300
H
M
250 L
Dimension
Model 200
Pst=Pa
A B C D E
150
FC-FM 200
FANS
FC-FM 315
500
Performance Curve
H
400
M
L
300
Pst=Pa
200
Model Phase kW g/min rpm dB(A)
100
FC-FM 250 1 0.14 2415 48
FC-FM 250
Performance Curve
700
600
H
M
500 L
400
Pst=Pa
300
200
100
0
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Q=m3/h
FC-FM 315
Dimension
Model
A B C D E
Features
Internally supported arm give minimum pressures drop,
ease of maintenance and prevents abrasion
Conical hood for better capture
Multiple mounting bracket for machine, wall, bench or
ceiling mounting
Control dampers are standard with this dust system
Handle for ease of positioning
Wall Bracket & Sing Boom Steel with Epoxy Powder Baked Finish
Features
An ergonomical and space saving solution for simple and
light application in the laboratory
Made of chemical resistant Polypropylene, it is a suitable
choice for extractor
Ducting and exhaust fan of common lab chemical fumes
quoted separately
Pipe PP Resin
ACCESSORIES
Custom made Extension Column
EXTRACTOR ARMS
Features
Flexible – can be bent, twisted, and turned easily without breaking
Self-supporting
No internal supports- airflow increased by up to 50% over externallyy
supported design
Expandable- Diameter can be increased
Durable – chemical and abrasion resistant
Model EXA-0982-1A
Diameter (inch) 3”
Material Polypropylene
Model EXA-0982-3
Diameter (inch) 3”
Material Polypropylene
Features
Mobile and compact. Can fit under bench easily
Steel housing with oven baked epoxy polyester coated
Equipped with chemical resistant PVC fan as standard
Durable castor wheel with two brakes
Various filters to meet different application
Suitable with EXA or CLE model arms
Designed for easy maintenance of filter
Model EXA-0987-1
34 FILTER TYPES
SYNTHETIC PRE-FILTER
FC-CARDEAM
Features
Low initial pressure loss.
Easy to install and long service life.
Features
Easy handling, installation and removal.
Microglass paper with water repellent binder.