Control Number ZN5STCE-02

Liquid Sample
Temperature Controller
STC-500L

Instruction Manual

CAUTION
To use the unit correctly, read this instruction manual before use.
Keep the manual at hand when operating the unit.

Nittoseiko Analytech
EC DECLARATION OF CONFORMITY
We hereby declare that the following equipment complies with the essential requirements
of:

Electromagnetic Compatibility Directive: 2014/30/EU


Low Voltage Directive: 2014/35/EC
RoHS Directive: 2011/65/EU (include(EU)2015/863)

Model Name : Liquid Sample Temperature Controller Model STC-500L

Standard to which Conformity is Declared:

EN 61000-6-4:2019 : Generic standards-Emission standard for industrial environments

EN 61000-6-2:2019 : Generic standards-Immunity standard for industrial environments

EN 61010-1:2010/A1:2019 : Safety requirements for electrical equipment for measurement,


control, and laboratory use

EN IEC 63000:2018 : Technical documentation for the assessment of electrical and


electronic products with respect to the restriction of hazardous
substances

Name of Manufacturer : NITTOSEIKO ANALYTECH CO., LTD.

Manufacturer’s Address : 7-10-1 Chuo-rinkan, Yamato, Kanagawa 242-0007, Japan

EU Office Address : MITSUBISHI CHEMICAL EUROPE GmbH


Willstaetterstr. 30, 40549 Duesseldorf, Germany

Type of Equipment : Laboratory Equipment

Month and year of CE Marking : June, 2017

_______________________
Name : Kaoru Hayashi
Position : General Manager

Date : 16 . 07 . 2021
DD.MM.YYYY
UK Declaration of Conformity (DoC)

Object of Declaration
Product name: Liquid Sample Temperature Controller
Model name: STC-500L

Manufacturer
Name: NITTOSEIKO ANALYTECH CO., LTD.
Address: 7-10-1 Chuo-rinkan, Yamato, Kanagawa 242-0007, Japan

(Authorized Representative)
(Name: a1-envirosciences Ltd )
(Address: Suite2, Ground Floor,910 Birchwood Boulevard, Birchwood
Warrington WA3 7QN United Kingdom )

We declare that the DoC is issued under our sole responsibility and that the object of the
declaration described above is in conformity with the following relevant UK legislation:
Electromagnetic Compatibility Regulations 2016
Electrical Equipment (Safety) Regulations 2016
The Restriction of the Use of Certain Hazardous Substances in Electrical
and Electronic Equipment Regulations 2012

The following UK designated standards and other technical specifications have been applied.
EN61000-6-4:2019
EN61000-6-2:2019
EN61010-1:2010/A1:2019
EN IEC 63000:2018

Date of issue: 01 . 04 . 2022


DD . MM . YYYY

Place of issue: Japan

Signature: ____________________
Name: Kaoru Hayashi
Position / Title: General Manager
Introduction 1

Introduction
Thank you for purchasing the STC-500L liquid sample temperature controller.
By attaching the vial rack and syringe holder of this unit to the liquid autosampler ASC-
550L, it makes possible to measure the temperature-controlled liquid.
STC-500L has cooling and heating modes. Since the unit is delivered with the mode
set, it cannot be changed.
This is the instruction manual for the STC-500L liquid sample temperature controller.
To use the unit efficiently and safely, read this manual and fully understand the
functions and the operation methods before use.
You will find indispensable information about the explanation of each part of the unit,
specifications, and guarantee provisions in this instruction manual.
The NSX-5000 system is consisted of an injector, an electric furnace, and a detector.
There are unit combinations for each measurement. Read the instruction manuals of
each unit. For the measurement operation, read the operation manual.

Before Use

Take care of the following points about this manual.

(1) Do not reprint this manual wholly or partially without permission.

(2) The contents may be changed without notice.

(3) Though this manual was prepared carefully, contact our local distributor when
mistakes, omissions, or missing pages are found.
The application software windows in this manual may be different depending on
the version of the software.

(4) For any consequences of used results, we do not take any responsibility
regardless of (3).

(5) Assign specific operators and supervisors when using this unit.

(6) Always follow the contents in this manual. When problems or damages occur by
neglecting the contents in this manual, we do not guarantee the system even
within guarantee period.

Nittoseiko Analytech has the copyrights of this manual and the unit software.
Microsoft and Windows are registered trademarks of Microsoft Corporation.
Other company and product names described in this manual are their trademarks and
registered trademarks.

STC-500L (NSX-5000)
2 Introduction

About This Manual

About Composition

This instruction manual is composed as follows.

• Section 1 to 3 (introduction)
These sections describe the names and functions of the unit, parts list, and
installation.
• Section 4 to 6 (operation)
These sections describe measurement, troubleshooting, and maintenance
and inspection.
• Section 7 to 10 (other)
These sections describe the disposal of the unit, specifications, guarantee
provisions, and consumables.

About Indications

The elements of the window are expressed as follows.


• The names of menus, windows, icons, and items are expressed with double
quotations marks. The button names are expressed with brackets.
Example: [OK] button
Click “File”-“New”-“Folder” of the menu.
• Keyboard keys are expressed with angle brackets.
Example: Press <F5> key.
• The title of a reference chapter is expressed with double quotation marks.
Example: Refer to “3-1. Installation Conditions”.

The icon selection of the menu and buttons is expressed as follows.


Example: Click “File”-“New”-“Folder” of the menu.
Click [OK].

Refer to “SAFETY PRECAUTIONS” for the indications of warnings and cautions.

About Terms

This manual uses the following terms.


• Application software: Software for operating the system from a PC

STC-500L (NSX-5000)
SAFETY PRECAUTIONS 1

SAFETY PRECAUTIONS
Read this instruction manual,the operation manual, and the instruction manuals
supplied with parts carefully before use.
Always read safety precautions before use.
Security cannot be assured if the unit is operated without following the instructions in
this manual. Keep the manual and the instruction manuals supplied with parts at hand.

Indications of Safety Precautions

This instruction manual uses several indications to highlight critical precautions. The
items with these indications are important for the safe use of the unit. Always observe
them. The following indications are used for safety precautions.

WARNING
Information under this sign explains critical operations which contain the
risks of death or serious casualties caused by wrong handing.

CAUTION
Information under this sign explains critical operations which contain the
risks of human or property damages caused by wrong handing.

Other Indications

Besides the safety precaution indications, this instruction manual uses the following
indication to show an important or useful thing for measurement with this unit. The items
with these indications are important for the safe use of the unit. Be sure to read them
before use.

POINT
This indicates an important or useful thing for measurement with this unit.

STC-500L (NSX-5000)
2 SAFETY PRECAUTIONS

Warnings and Cautions

Labels

The following label is attached to the unit.


Always follow the instructions on the labels.

Warning or Caution label Attached place


It is on the top surface of vial rack.

Cautions

Read the following cautions carefully to use the unit correctly and safely.

Installation

When installing the unit, always observe the following precautions.

WARNING Room temperature


Install the unit in a place where room temperature during use is 15 to 35
degrees Celsius and daily temperature change is small.
Failure to do so may cause a fault or significantly shorten the service life.
It may also cause unstable operation or a fire.

WARNING Air conditioning


Install the unit in a place free from the direct wind from an air conditioner.
Failure to do so may cause unstable operation or a fire.

STC-500L (NSX-5000)
SAFETY PRECAUTIONS 3

WARNING Humidity
Install the unit in a place where humidity is 80%RH or less and the
cooling part does not condense.
Failure to do so may cause condensation and lead to a fire or an electric
shock. Use an air conditioner to create a humidity environment that does
not cause condensation.

WARNING Dust
Install the unit in a place free from much dust.
Failure to do so may cause a fire or electric shock. Clean the area around
the unit regularly. If the inlet or outlet of the unit is blocked by dust, the
temperature inside the unit will rise. It may cause a fault or significantly
shorten the service life.

WARNING Direct sunlight


Install the unit in a place free from direct sunlight.
Failure to do so may lead to a fire.

WARNING Fire
Install the unit in a place where fire is not used.
Failure to do so may lead to a fire.

WARNING Altitude
Install the unit in a place where the altitude is below 2000 meters to avoid
unstable operation, a fire, or an electric shock.

CAUTION Ventilation
Ventilate the room by an air conditioning or ventilating fan, etc.
Failure to do so may damage health by the gas generated from
chemicals or the exhaust gas of the unit.

STC-500L (NSX-5000)
4 SAFETY PRECAUTIONS

CAUTION Corrosive gas


Install the unit in a place free from corrosive gas.
Failure to do so may cause a fault and lead to an accident.
Sea salt particles are present in the air near the sea, and it may cause
poor insulation or corrosion deterioration.

CAUTION Combustibles
Do not place combustibles around the unit. If a fire occurs, more damage
will be caused.

CAUTION Vibration
Install the unit in a place free from strong vibration or continuous weak
vibration. Failure to do so may cause unstable operation or a fault and
lead to an accident.

CAUTION Electromagnetic field


Install the unit in a place free from strong electromagnetic field.
Failure to do so may cause errors and lead to an accident.

CAUTION Installation surface


Install the unit on a flat surface.
Failure to do so may lead the unit fall or collapse and cause injury.

CAUTION Earth terminal


Check that earth terminal is properly connected.
Failure to do so may cause an electric shock.

STC-500L (NSX-5000)
SAFETY PRECAUTIONS 5

CAUTION Power off of ASC-550L


When installing the STC syringe cover and STC bracket, turn off the
power of the ASC-550L unit.
Failure to do so may cause the ASC-550L unit to operate and result in
injury or damage to the unit.

CAUTION Transportation
When moving the unit, firmly hold it with hands and do not incline it.
Bumping the unit or falling it causes not only unit breakage but also
injuries.

Usage

When measuring with the unit, observe the following warnings and precautions.

WARNING Prohibition of unattended


operation
Do not use this unit without attendance at night or other situations.
This unit is intended for attended operation. If there is no one around
when an error occurs, appropriate measures cannot be taken promptly,
which may lead to a serious accident.

WARNING Microsyringe to use


Always use microsyringes specified by us when injecting the sample.
Failure to do so may break microsyringes or cause a fire due to abnormal
combustion.

WARNING Combustibles and combustible


gas
Keep the system off the combustibles and combustible gas.
The electric furnace of this system is hot during operation. Direct contact
of combustible with the electric furnace or spilling combustible liquid
around the unit may lead to a fire.

STC-500L (NSX-5000)
6 SAFETY PRECAUTIONS

WARNING Power plug


Never touch a power plug with wet hands.
Failure to do so may lead to electric shock.

WARNING Power cable


Do not bundle the power cable or use it with physical force applied to it.
Do not heat the power cable.
A hot or broken power cable may lead to a fire or an electric shock.
Do not use a power cable under the rating, or modified or broken one.
Use a power cable based on our specification.

WARNING Cable and connectors on the


rear of the unit
Do not touch the cables and connectors on the rear of the unit during
use.
Doing so may cause communication failure or malfunction and cause a
fire.

WARNING Indication of WARNING


When “WARNING” is displayed in the PC monitor, this indicates the risks
of serious accidents.
When these messages are displayed, deal with the problems
immediately.

WARNING For protection


When handling chemicals, always wear protectors.
If the chemical is attached to the body, it may lead to a chemical burn or
blindness. When handling chemicals, always check the safety data sheet
and wear protective glasses and gloves.

STC-500L (NSX-5000)
SAFETY PRECAUTIONS 7

WARNING Input outside the setting range


When “B No.” is set to other than 12 to 19, 22 to 29, and 32 to 39, the
gastight microsyringe tries to absorb the sample from a place where there
is no hole for the measuring vial in the STC vial rack. Therefore, it may be
damaged and cause a fire.

CAUTION Placing vial


When placing vials in the STC vial rack, make sure that the schedule step
is stopped in the application software.
Failure to do so may cause the ASC-550L unit to operate and result in
injury or damage to the unit.

CAUTION Cover of the unit


Do not remove the cover of the unit.
Doing so may cause a fault or electric shock.

CAUTION Unit supervisors and operators


Assign specific supervisors and operators for the system.
Sufficient caution is required for installing and using the system.
Supervisors should manage and supervise the system and its operators.
If the management and supervision of this system or an operator are not
enough, accidents or injuries may be caused because of insufficient
inspection or incorrect operation.

Operation

When operating the system, always observe the following precautions.

CAUTION Maintenance and inspection


Be sure to perform daily and periodical inspections before using the unit.
Failure to check the unit may lead not only to the poor performance but
also to serious accidents.

STC-500L (NSX-5000)
8 SAFETY PRECAUTIONS

About the Cooling Mode

When using the STC-500L cooling mode, the performance and cautions are as follows.

(1) Temperature control system


Temperature is controlled by the Peltier element and controllable temperature
depends on room temperature. Refer to “Section 8: Specifications” for details.

(2) Valid samples for the cooling mode


By measuring high-volatile samples with the ASC-550L unit, samples will vaporize
from the gastight microsyringe tip and stable measurement cannot be run. In
addition, a fire may be caused by the ignition to vaporized combustible gas.
By keeping vials and a gastight microsyringe low-temperature with the cooling
mode, sample vaporization from the syringe tip after sampling can be controlled.
Thus, measurement values fluctuation can be reduced and measurement can be
run safely.

(3) Cautions in the cooling mode


• When humidity is high, dew condensation is generated on the cooling part and
a fire or an electric shock may be caused. Use an air conditioner to maintain the
temperature environment free from dew condensation. When dew condensation
occurs on the cooling part, check that the ASC-550L unit has stopped
completely. Wipe water with a dry cloth.
• Even when a cooled gastight microsyringe is used, some samples vaporize
from the needle tip. Do not measure these samples to avoid a fire.
• By using samples which become more viscous or solidifies by cooling, samples
can not be aspirated or a gastight microsyringe breaks. Check sample
conditions before measurement start.
Control a setting environment and sample temperature as the above. Understand
sample properties before using the STC-500L unit.

WARNING Handling in combustible


samples
By measuring high-volatile combustible samples, a fire may be caused by
the ignition to vaporized combustible gas. Fully understand sample
properties and the unit performance before handling the samples.

STC-500L (NSX-5000)
SAFETY PRECAUTIONS 9

About the Heating Mode

When using the STC-500L unit in the heating mode, the performance and cautions are
as follows.

(1) Temperature control system


Temperature is controlled by the Peltier element and controllable temperature
depends on room temperature. The maximum setting temperature is 60 ℃ in the
heating mode. Refer to “Section 8: Specifications” for details.

(2) Valid samples for the heating mode


By measuring high-viscosity liquid samples with the ASC-550L unit, samples can
not be aspirated with a gastight microsyringe and stable measurement cannot be
run.
Keep vials and a gastight microsyringe high-temperature in the heating mode.
Sample viscosity can be reduced and sample aspiration will be easier. Thus,
measurement values fluctuation can be reduced.

(3) Cautions in the heating mode


• When humidity is high, dew condensation is generated on the fin and a fire or
an electric shock may be caused. Use an air conditioner to maintain the
temperature environment free from dew condensation. When dew condensation
occurs on the fin, check that the ASC-550L unit has stopped completely. Wipe
water with a dry cloth.
• By heating samples in the heating mode, viscosity reduces and they may fall
from the gastight microsyringe tip. For samples with low boiling points, they
easily vaporize from gastight microsyringe tip after sampling. A fire may be
caused. Do not lower sample temperature too much.
• By sampling without melting a solid sample, the gastight microsyringe may be
broken. Check the sample conditions before measurement start.
• Even if sampling is run with the solid sample melted, some samples solidify on
the microsyringe tip. Do not measure these samples to avoid microsyringe
breakage.
Control a setting environment and sample temperature as the above. Understand
sample properties before using the STC-500L unit.

WARNING Handling in combustible


samples
By measuring high-volatile combustible samples, a fire may be caused by
the ignition to vaporized combustible gas. By using the heating mode,
viscosity reduces. They may fall from the gastight microsyringe tip and
vaporize from the tip. Fully understand sample properties and the unit
performance before handling the samples.

STC-500L (NSX-5000)
10 SAFETY PRECAUTIONS

STC-500L (NSX-5000)
Table of Contents 1

Table of Contents
Introduction ...................................................................................................................... 1
Before Use ................................................................................................................ 1
About This Manual .................................................................................................... 2
SAFETY PRECAUTIONS ................................................................................................ 1
Indications of Safety Precautions .............................................................................. 1
Other Indications ....................................................................................................... 1
Warnings and Cautions............................................................................................. 2
Labels ............................................................................................................... 2
Cautions............................................................................................................ 2
About the Cooling Mode ........................................................................................... 8
About the Heating Mode ........................................................................................... 9
Section 1: Names and Functions of the Unit................................................................. 1-1
1-1. STC-500L Unit Structure ................................................................................ 1-1
1-2. Names and Functions of the Temperature Controller Front Panel ................. 1-2
1-3. Names and Functions of Temperature Controller Rear Panel ........................ 1-3
1-4. Names and Functions of STC Vial Rack......................................................... 1-4
1-5. Names and Functions of STC Syringe Holder ................................................ 1-6
Section 2: Parts Check ................................................................................................. 2-1
2-1. STC-500L Parts .............................................................................................. 2-1
2-2. Other Parts ..................................................................................................... 2-1
Section 3: Installation ................................................................................................... 3-1
3-1. Installation Conditions..................................................................................... 3-1
3-2. Installation Space ........................................................................................... 3-1
3-3. Power Preparation .......................................................................................... 3-2
3-3-1. Power .................................................................................................. 3-2
3-3-2. Grounding ............................................................................................ 3-2
3-4. Installation of Each Part .................................................................................. 3-2
3-4-1. Installation of STC Syringe Cover and STC Bracket ........................... 3-2
3-4-2. Installation of STC Syringe Holder and STC Vial Rack ....................... 3-3
3-4-3. Connection of STC Vial Rack Cable .................................................... 3-4
3-4-4. Connection of STC Syringe Holder Cable ........................................... 3-5
3-5. Adjustment of Injection Position and Injection Height ..................................... 3-6
3-6. Setting of ASC-550L Unit Configuration ......................................................... 3-6

STC-500L (NSX-5000)
2 Table of Contents

Section 4: Measurement .............................................................................................. 4-1


4-1. Preparation Before Measurement .................................................................. 4-1
4-2. Temperature Setting ...................................................................................... 4-1
4-3. Bottle Setting ................................................................................................. 4-2
4-4. Dealing with Condensation ............................................................................ 4-2
4-5. Operation After Measurement ........................................................................ 4-2
Section 5: Troubleshooting .......................................................................................... 5-1
5-1. No Power to the Temperature Controller ....................................................... 5-1
5-2. Temperature is Not Displayed on the Temperature Controller ....................... 5-1
5-3. STC Vial Rack does Not Reach the Set Temperature ................................... 5-2
5-4. STC Syringe Holder does Not Reach the Set Temperature ........................... 5-2
Section 6: Maintenance and Inspection ....................................................................... 6-1
6-1. Daily Inspection and Maintenance ................................................................. 6-1
6-2. Periodical Inspection and Maintenance ......................................................... 6-2
6-3. Storage of the Unit ......................................................................................... 6-4
Section 7: Disposal of the Unit ..................................................................................... 7-1
Section 8: Specifications .............................................................................................. 8-1
8-1. STC-500L Unit Specifications ........................................................................ 8-1
Section 9: Guarantee Provisions ................................................................................. 9-1
9-1. Guarantee Provisions for Japan..................................................................... 9-1
9-2. Guarantee Provisions for Products Sold Overseas ........................................ 9-3
Section 10: Consumables .......................................................................................... 10-1
10-1. STC-500L Consumables ............................................................................ 10-1

STC-500L (NSX-5000)
Names and Functions of the Unit 1-1

Section 1: Names and Functions of the Unit


This section describes the structure of STC-500L and the names and functions of each
part. The STC vial rack and STC syringe holder of STC-500L are installed on the liquid
autosampler ASC-550L. For the names and functions of the liquid autosampler, refer to
the ASC-550L instruction manual.

1-1. STC-500L Unit Structure

Fig. 1-1 shows STC-500L unit structure and Table 1-1 shows the names and functions.

5 4
3

1 2

Fig. 1-1. STC-500L Unit Structure

Table 1-1. Names and Functions of STC-500L

No. Name Indication Function


1 Temperature Set the temperature of the STC vial rack and STC
controller syringe holder.
2 STC vial Place the measuring vials and 28 mL vial and control
rack their temperature. Select a rack according to the
capacity of the measuring vials to be used.
3 STC syringe Attach to the ASC-550L syringe tower. Set a gastight
holder microsyringe and control the temperature.
4 STC bracket Attach to the ASC-550L syringe tower. The magnetic
holder for the STC syringe cover is attached.
5 STC syringe Remove the ASC-550L syringe cover and attach the
cover STC syringe cover. Use with the cover closed.

STC-500L (NSX-5000)
1-2 Names and Functions of the Unit

1-2. Names and Functions of the Temperature Controller


Front Panel

Fig. 1-2 shows the front panel of a temperature controller. Table 1-2 shows the names
and functions of temperature controller front panels.

2 3

Fig. 1-2. Temperature Controller Front Panel

Table 1-2. Names and Functions of Temperature Controller Front Panel

No. Name Indication Function


1 Power switch POWER STC-500L power switch. When it is turned on,
power is supplied to the temperature
controller, STC vial rack, and STC syringe
holder.
2 STC syringe SYRINGE This sets STC syringe holder temperature.
holder TEMP. Change values with [↑] or [↓] key. For details,
temperature refer to the temperature controller instruction
controller manual.
3 STC vial rack VIAL RACK This sets STC vial rack temperature.
temperature TEMP. Change values with [↑] or [↓] key. For details,
controller refer to the temperature controller instruction
manual.

STC-500L (NSX-5000)
Names and Functions of the Unit 1-3

1-3. Names and Functions of Temperature Controller Rear


Panel

Fig. 1-3 shows the rear panel of a temperature controller. Table 1-3 shows the names
and functions of the temperature controller rear panel.

1
2 5

7 6

Fig. 1-3. Temperature Controller Rear Panel

Table 1-3. Names and Functions of Temperature Controller Rear Panel

No. Name Indication Function


1 STC vial rack VIAL RACK Switch that turns ON/OFF the temperature
power Switch POWER control of the STC vial rack. Turn it off if STC
vial rack temperature is not controlled.
2 STC syringe SYRINGE Switch that turns ON/OFF the temperature
holder power POWER control of the STC syringe holder. Turn it off if
switch it is not performed.
3 STC syringe SYRINGE Connect STC syringe holder cables.
holder connector
4 STC vial rack VIAL RACK Connect STC vial rack cables.
connector
5 Fuse holder FUSE 5A There is a fuse inside. Use our specified fuse.
TYPE T
6 Power connector a.c. Insert the power cable to supply power. Use a
POWER power cable based on our specification.
7 Rear cover Do not open the rear cover. If you change the
default setting, temperature cannot be
controlled normally.

STC-500L (NSX-5000)
1-4 Names and Functions of the Unit

1-4. Names and Functions of STC Vial Rack

Fig. 1-4 shows the STC vial rack. Table 1-4 shows the names and functions of the STC
vial rack.

2
3
4

5
7
6

Fig. 1-4. STC Vial Rack

Table 1-4. Names and Functions of STC Vial Rack

No. Name Indication Function


1 Position for vials for 12 to 19 Place to set measuring vials for calibration
measurement 22 to 29 curve solutions or samples. Place the
measuring vials according to the capacity of
32 to 39 the STC vial rack. The available bottle
numbers are limited.
2 Position for vials for Place to set the 28 mL vial containing
washing solution washing solution. For the washing solution,
select the most suitable solvent for washing.
3 Position for vials for When using the Bottle B function, place the
multipurpose 28 mL vial in this place. For the functions,
refer to the ASC-550L instruction manual.
4 Position for vials for Place where waste solution is collected. Place
waste solution an empty 28 mL vial.
5 STC vial rack cable Connect to the STC vial rack connector on the
temperature controller rear.
6 Fan Heat exchange by the Peltier element is
promoted.

STC-500L (NSX-5000)
Names and Functions of the Unit 1-5

No. Name Indication Function


7 Fin Heat exchange by the Peltier element is
promoted. The fin hots at the cooling mode.
The fin cools at the heating mode.

STC-500L (NSX-5000)
1-6 Names and Functions of the Unit

1-5. Names and Functions of STC Syringe Holder

Fig. 1-5 shows the STC syringe holder. Table 1-5 shows the names and functions of the
STC syringe holder.

3 4

Fig. 1-5. STC Syringe Holder

Table 1-5. Names and Functions of STC Syringe Holder

No. Name Indication Function


1 STC syringe holder Set our specified gastight microsyringe.
2 STC syringe holder Connect to the STC syringe holder connector
cable on the temperature controller rear.
3 Fan Heat exchange by the Peltier element is
promoted.
4 Fin Heat exchange by the Peltier element is
promoted. The fin hots at the cooling mode.
The fin cools at the heating mode.

STC-500L (NSX-5000)
Parts Check 2-1

Section 2: Parts Check


This section describes the parts packaged in the delivered STC-500L unit. Some part
compositions may not be supported depending on the system configuration.
When initially opening the package, check that the following parts are included. For
consumables, refer to “Section 10: Consumables”.

2-1. STC-500L Parts

Table 2-1 shows STC-500L parts.

Table 2-1. STC-500L Parts

No. Parts Name Quantity Check Remarks


1 Temperature controller 1 unit
2 STC syringe cover 1 pc
3 STC bracket 1 pc
4 STC syringe holder 1 unit
5 Cable clamp 5 pcs
6 STC vial rack 1 unit Either 2 mL, 4 mL,
or 6 mL
7 Fuse 5A 2 pcs Spare parts
8 Cable tie W2.5 mm x L100 mm 6 pcs 3 pcs for spare parts

2-2. Other Parts

Table 2-2 shows other parts.

Table 2-2. Other Parts

No. Parts name Quantity Check Remarks


1 Power cable (100 V or 230 V) 1 pc 100 V or 230 V

STC-500L (NSX-5000)
2-2 Parts Check

STC-500L (NSX-5000)
Installation 3-1

Section 3: Installation
This section describes necessary space and power for STC-500L installation.

3-1. Installation Conditions

Install the unit indoors to meet the following conditions for the long-term stable use.
Refer to “SAFETY PRECAUTIONS” in this manual for details.
• Room temperature is 15 to 35 degrees Celsius. Temperature change is small.
• This unit is not exposed to direct wind from an air conditioner.
• Humidity is under 80%RH. (No condensation)
• No much dust
• No direct sunlight
• Fire is not used.
• The room is ventilated.
• No corrosive gas
• No flammable materials around the unit
• No strong vibration and continuous weak vibration
• No strong electromagnetic field
• The surface for installation is flat and stable.
• Altitude is less than 2000 meters.

If problems or damages are caused by negligence of the above conditions, we cannot


guarantee the unit even within the guarantee period. Please be aware of this in advance.

3-2. Installation Space

STC-500L installation space is as follows.


Depending on the system configuration, prepare enough space for the complete system.
• Table withstand load: About 7 kg
• Set aside more than 150 mm space between the unit and the back wall.
• Install the STC-500L temperature controller on top of the detector.
• Install the STC-500L vial rack to the ASC-550L unit.
• Install the STC syringe holder of STC-500L to the ASC-550L unit.

STC-500L (NSX-5000)
3-2 Installation

3-3. Power Preparation

3-3-1. Power

STC-500L consumption power is as follows. The allowable range of voltage fluctuation is


within ±10%. When it is over 10%, use a voltage stabilizer.
• 100/115/230/240 V 50/60 Hz 400 VA

3-3-2. Grounding

The STC-500L power cable is a 3-line type cable including a grounding wire. Prepare
either of the following appropriate outlets with ground on the table, and securely ground
the power cable. Select an outlet with ground according to the power supply voltage in
your area. If you cannot prepare the following outlet with ground, prepare a grounded
outlet and a grounded cable that satisfy the rating and unit power consumption
conditions.
• 100/115 V Rating 125 VAC, 15 A (JIS C 8303)
• 230/240 V Rating 250 VAC, 16 A (SE type)

CAUTION Earth terminal


Check that earth terminal is properly connected.
Failure to do so may cause an electric shock.

3-4. Installation of Each Part

3-4-1. Installation of STC Syringe Cover and STC Bracket

The STC syringe cover and STC bracket are attached to the ASC-550L syringe tower in
the following procedures. Refer to Fig. 3-1. Assembly of STC Syringe Cover and STC
Bracket.

CAUTION Power off of ASC-550L


When installing the STC syringe cover and STC bracket, turn off the
power of the ASC-550L unit.
Failure to do so may cause the ASC-550L unit to operate unexpectedly
and result in injury or damage to the unit.

STC-500L (NSX-5000)
Installation 3-3

(1) Remove the syringe cover attached to the ASC-550L unit and attach the STC
syringe cover. When removing the syringe cover, remove 1. hinge screws (4pcs)
(two each on the top and bottom) attached to the syringe tower.
(2) Attach the hinges that are attached to the syringe cover to 2. STC syringe cover.
Use 1. hinge screws to attach the STC syringe cover to the syringe tower. At this
time, make sure that the hinges are attached in the same direction as the syringe
cover.
(3) Check that the power of the ASC-550L unit is OFF. Handle the syringe tower moving
screw on the left side of the ASC-550L unit with a flathead screwdriver, and move
the syringe tower to the center.
(4) Loosen 3. screws (2pcs) on the right side of the syringe tower, attach 4. STC bracket,
and tighten the screws to fix it vertically.

1.
4.
3.

2.

Fig. 3-1. Assembly of STC Syringe Cover and STC Bracket

3-4-2. Installation of STC Syringe Holder and STC Vial Rack

The STC syringe holder and STC vial rack are attached to the ASC-550L unit in the
following procedures. Refer to “Fig. 3-2. Installation of STC Syringe Holder and STC Vial
Rack”.

(1) Fix 1. STC syringe holder to the syringe tower with 2. fixing screws (2pcs). Pass the
STC syringe holder cable through 3. STC bracket.
(2) Install 4. STC vial rack.

STC-500L (NSX-5000)
3-4 Installation

3.
1.

2.

4.

Fig. 3-2. Installation of STC Syringe Holder and STC Vial Rack

3-4-3. Connection of STC Vial Rack Cable

This section describes the procedures for connecting the STC vial rack cable. When the
STC vial rack installed on the ASC-550L unit moves back and forth, the STC vial rack
cable on the right front panel is pulled back and forth. Thus, it is necessary to create a
deflection of the cable. Refer to “Fig. 3-3. Fixing the STC Vial Rack Cable”.

(1) Remove the front screw on the right side of the ASC-550L unit. Use 1. cable clamp
and the removed screw and fix the STC vial rack cable. At this time, fix the part
about 15 cm from the right end of the ASC-550L unit and provide 2. deflection
between the ASC-550L and the cable.
(2) Remove the two screws on the ASC-550L unit rear. Use 3. cable clamp and the
removed screws and fix the STC vial rack cable.
(3) Connect the STC vial rack cable to 4. STC vial rack connector (VIAL RACK) on the
temperature controller rear.

2.
3. 4.
1.

Fig. 3-3. Fixing the STC Vial Rack Cable

STC-500L (NSX-5000)
Installation 3-5

3-4-4. Connection of STC Syringe Holder Cable

This section describes the procedures for connecting the STC syringe holder cable.
When the ASC-550L unit operates, the STC syringe holder cable moves up, down, left
and right. The STC syringe holder is pulled up and down, thus deflection of the cable is
needed. Refer to “Fig. 3-4. Fixing the STC Syringe Holder Cable”.

(1) Handle the syringe tower moving screw on the left side of the ASC-550L unit with a
flathead screwdriver. Move the syringe tower to the right when viewed from the
front.
(2) Remove the screw on the ASC-550L syringe tower rear. Use 1. cable clamp and the
removed screw and fix the STC syringe holder cable that comes out of the STC
bracket. At this time, fix it at a position where there is 2. deflection of about 15 cm on
the upper surface of the syringe tower.
(3) Lower the STC syringe holder cable to half the height of the ASC-550L unit rear. At
this time, make sure that it is positioned on the outside of the STC vial rack holder.
(4) Remove the screw on the upper right of the ASC-550L unit rear. Use 3. cable clamp
and the removed screw and fix the STC syringe holder.
(5) Connect the STC syringe holder cable to 4. STC syringe holder connector
(SYRINGE) on the temperature controller rear.
(6) Check the connection status of the STC vial rack cable and STC syringe holder
cable, turn on the power switch of ASC-550L, perform the initialization operation,
and check if the deflection of the cable is sufficient. If it is not enough, loosen and
adjust each cable clamp to create more.

1
2

Fig. 3-4. Fixing the STC Syringe Holder Cable

STC-500L (NSX-5000)
3-6 Installation

3-5. Adjustment of Injection Position and Injection Height

Refer to the ASC-550L instruction manual “3-5-3. Installation of Syringe Holder and
Gastight Microsyringe” and attach the gastight microsyringe (SGE) to the STC Syringe
Holder. Also, refer to “3-5-4. Setting of Injection Position and Injection Height” and adjust
the injection position and height.

3-6. Setting of ASC-550L Unit Configuration

When using STC-500L, the measurable bottle number is different from normal ASC-550L.
Therefore, it is necessary to change the ASC-550L unit configuration in the application
software. It can be changed in the following procedures.

(1) Select “Help” and “Equipment Composition” of the menu to display the composition
window.
(2) Select “ASC-550L” in “Injector” item, and select STC-500L with [▼].
(3) Click [OK] button.

STC-500L (NSX-5000)
Measurement 4-1

Section 4: Measurement
This section describes the measurement setting method with the STC-500L unit. For
settings other than those related to STC-500L, read the operation manual. Furthermore,
precautions are different between the cooling and heating modes. Read the “SAFETY
PRECAUTIONS” carefully before use.

4-1. Preparation Before Measurement

For the preparation before measurement, refer to the ASC-550L instruction manual. The
STC vial rack cable is fixed, therefore, place the vials with the STC vial rack installed on
the ASC-550L unit.

CAUTION Placing vials


When placing vials in the STC vial rack, make sure that the schedule step
is stopped in the application software.
Failure to do so may cause the ASC-550L unit to operate unexpectedly
and result in injury or damage to the unit.

4-2. Temperature Setting

This section describes the temperature setting method of the STC vial rack and STC
syringe holder. Set a desired temperature by the following procedures.

POINT Controllable temperature


For STC-500L, controllable temperature varies depending on the room
temperature.
Understand the specifications well and set it within the controllable
temperature range.

(1) Turn on the power switch (POWER) on the temperature controller front.
(2) Operate [↑] or [↓] key of the STC syringe holder temperature controller (SYRINGE
TEMP.) and STC vial rack temperature controller (VIAL RACK TEMP.), and set the
desired temperature.
(3) When the desired temperature is reached and it is sufficiently transmitted to the
sample in the measuring vials and the gastight microsyringe, start the measurement.

STC-500L (NSX-5000)
4-2 Measurement

4-3. Bottle Setting

In STC-500L, “B No.” (bottle number) that can be entered is different from the normal
ASC-550L vial tray. Only 12 to 19, 22 to 29, and 32 to 39 can be set. Check the “B No.”
of the schedule before measurement.

WARNING Input outside the setting range


When “B No.” is set to other than 12 to 19, 22 to 29, and 32 to 39, the
gastight microsyringe tries to aspirate the sample from places where there
are no holes to set the measuring vials in the STC vial rack. Therefore, it
may be damaged and cause a fire.

When “B No.” outside the range is entered, it cannot be added to the schedule even if
[Add] on the Step Editor window is clicked. When [Constant] is used, “B No.” that cannot
be set is skipped and entered.

4-4. Dealing with Condensation

If condensation occurs on the cooling part of STC-500L, wipe off the water with a dry cloth
while the ASC-550L unit is completely stopped. If it is left, it may corrode the unit or short-
circuit the power supply.
If condensation occurs frequently, review the humidity of the installation environment.

4-5. Operation After Measurement

When the power switch (POWER) on the temperature controller front is turned off, its
display will disappear and the temperature control will stop. For other post-measurement
operations, refer to the ASC-550L instruction manual.

STC-500L (NSX-5000)
Troubleshooting 5-1

Section 5: Troubleshooting
This section describes the troubleshooting of STC-500L. When problems are not solved
even by taking countermeasures, contact our local distributor.

CAUTION Cover of the unit


Do not remove the cover of the unit except for our servicemen.
Doing so may cause a fault or electric shock.

5-1. No Power to the Temperature Controller

Cause Countermeasure
 The power cable is Connect the power cable firmly to the power
disconnected from the connector (a.c. POWER).
power connector.
 The power plug is not Connect the power plug firmly to the outlet.
inserted properly into the
outlet.
 Power is not supplied to Check that power is supplied to the outlet by using
the outlet. another instrument.
 The power fuse is blown. Take off the fuse holder of the unit with a flathead
screwdriver. Check the conduction between both ends
with a tester. If there is no conduction, change the
fuse with new one.

5-2. Temperature is Not Displayed on the Temperature


Controller

Cause Countermeasure
 The STC vial rack power Turn on the STC vial rack power switch (VIAL RACK
switch is off. POWER) on the temperature controller rear.
 The STC syringe holder Turn on the STC syringe holder power switch
power switch is off. (SYRINGE POWER) on the temperature controller
rear.
 The temperature controller Contact our local distributor.
is out of order.

STC-500L (NSX-5000)
5-2 Troubleshooting

5-3. STC Vial Rack does Not Reach the Set Temperature

Cause Countermeasure
 The STC vial rack cable is Connect the STC vial rack cable to the STC vial rack
disconnected from the connector (VIAL RACK) on the temperature controller
temperature controller. rear.
 Temperature of the STC Temperature that can be set depends on the room
vial rack temperature temperature. Check the specifications and set it within
controller is out of the the range.
specified range.
 Dust on the fans and fins. When there is dust, performance will not be sufficient.
Clean it with a vacuum cleaner.

5-4. STC Syringe Holder does Not Reach the Set Temperature

Cause Countermeasure
 The STC syringe holder Connect the STC syringe holder cable to the STC
cable is disconnected from syringe holder connector (SYRINGE) on the
the temperature controller. temperature controller rear.
 Temperature of the STC Temperature that can be set depends on the room
syringe holder temperature temperature. Check the specifications and set it within
controller is out of the the range.
specified range.
 Dust on the fans and fins. When there is dust, performance will not be sufficient.
Clean it with a vacuum cleaner.

STC-500L (NSX-5000)
Maintenance and Inspection 6-1

Section 6: Maintenance and Inspection


This section describes the maintenance and inspection to use the STC-500L unit safely in
the proper conditions. Perform maintenance and inspection on not only STC-500L, but
also other units that constitute the system.

6-1. Daily Inspection and Maintenance

Table 6-1 shows the daily inspection items. If any problems are found, solve the problem
and re-check the unit. When problems can not be solved or they may be inside the unit,
contact our local distributor.

CAUTION Daily inspection and


maintenance
Be sure to perform daily inspection and maintenance before the use of the
unit.
Failure to check or maintain the unit may lead not only to the performance
reduction but also to serious accidents.

Table 6-1. Daily Inspection Items

No. Item Contents


1 Check of STC vial rack Check the condition of STC vial rack.
2 Check of gastight microsyringe Check the condition of gastight microsyringe.
3 Check of STC syringe holder Check the condition of STC syringe holder.

The details of each daily inspection item and maintenance are as follows.

Check of STC Vial Rack

Check the condition of the STC vial rack and clean it if it is dirty. Also, if it gets dirty, clean
it immediately. If the STC vial rack is left dirty, vials will not be placed in the correct
positions. As a result, the STC syringe holder and gastight microsyringe may be
damaged.

Check of Gastight Microsyringe

Check the condition of gastight microsyringe. If the needle tip is curved or foreign
particles stick to it, repair it with sandpaper or a file. If the plunger becomes sluggish or is
loose, replace it with a new one.

STC-500L (NSX-5000)
6-2 Maintenance and Inspection

Check of STC Syringe Holder

Check the condition of STC syringe holder. Clean it if it becomes sluggish or dirty. For
the cleaning procedures, refer to the ASC-550L instruction manual “8-1. Daily Inspection
and Maintenance”, check of syringe holder.

6-2. Periodical Inspection and Maintenance

Table 6-2 shows the periodical inspection items. If any problems are found, solve the
problem and re-check the unit. When troubles can not be solved or they may be inside
the unit, contact our local distributor.

CAUTION Periodical Inspection and


maintenance
Always conduct periodical inspection and maintenance in the specified
cycle.
Failure to check or maintain the unit may lead not only to the performance
reduction but also to serious accidents.

Table 6-2. Periodical Inspection Items

No. Item Contents Frequency


1 Visual check of the Visually check for dirt, dust, fixed Every 2 weeks
appearance of the installing parts, and cable connections.
unit
2 Check of volume Check the collection volume using Every month
gastight microsyringe pure water.
collected
3 Cleaning of fans and Clean the fans and fins. Every 3 months
fins
4 Check of temperature Check if the key operation and Every 6 months
controller temperature display of the temperature
adjuster of the temperature controller
are normal.
5 Overall inspection Our local distributor undertakes Every year
periodical inspections.

The details of each periodical inspection item and maintenance are as follows.

STC-500L (NSX-5000)
Maintenance and Inspection 6-3

Visual Check of the Appearance of the Unit

Visually check the unit for dirt and dust every two weeks. If there is some dirt or dust,
clean it. Also, visually check the fixed state of the installing parts and the cable
connection.

POINT Unit cleaning


When cleaning the unit, do not use organic solvents.
Doing so may cause the coating of the unit to peel off.

Check of Volume Gastight Microsyringe Collected

Check the collected volume of gastight microsyringe every month. To check it, take
some volume of pure water with a gastight microsyringe, discharge it into a container on
the balance and check the weight.

Cleaning of Fans and Fins

Clean the fans and fins of the STC vial rack and STC syringe holder every three months.
In dusty areas, increase the frequency of cleaning. If the vial rack and syringe holder are
kept using with dust on the fans and fins, temperature control will be inefficient and set
temperature may not be reached. Fig. 6-1 shows where to clean the fans and fins.

Fig. 6-1. Cleaning Places of Fans and Fins

STC-500L (NSX-5000)
6-4 Maintenance and Inspection

Check of Temperature Controller

Operate [↑] and [↓] keys of the temperature controller and check the temperature display
every six months. If the keys do not respond or there is a problem with the display,
contact our local distributor.

Overall Inspection

Inspection items are determined according to the unit status and frequency of use.
Contact our local distributor for details.

6-3. Storage of the Unit

Store the STC-500L unit as follows when it is not used for long time.
The cautions for storing the unit on a table are as follows.
• Disconnect a power cable.
• Put the cover over the whole unit.

The cautions of the storage place are as follows.


• Store the unit in a place where room temperature is 0 to 45 degrees Celsius.
• Store the unit in a place where humidity is 80%RH or less with no condensation.
• Store the unit in a place free from much dust.
• Store the unit in a place free from corrosive gas.
• Store the unit in a place where fire is not used.
• Store the unit in a place free from direct sunlight.
• Store the unit in a place free from strong vibration and continuous weak
vibration.
• Store the unit in a place free from strong electromagnetic field.
• Store the unit in a horizontal and stable place.

STC-500L (NSX-5000)
Disposal of the Unit 7-1

Section 7: Disposal of the Unit


This section describes how to dispose of a used STC-500L unit for some reason.
If you dispose of a used STC-500L unit, comply with the ordinances of your local
government.
Please directly contact your local government for details.
If there are any unclear points, contact our local distributor.

STC-500L (NSX-5000)
7-2 Disposal of the Unit

STC-500L (NSX-5000)
Specifications 8-1

Section 8: Specifications
This section describes STC-500L specifications.

8-1. STC-500L Unit Specifications

Table 8-1 shows STC-500L unit specifications. For the precautions on cooling and
heating modes, refer to “SAFETY PRECAUTIONS”.

Table 8-1. STC-500L Unit Specifications

Item Specifications
Model STC-500L
Samples Liquid samples
Temperature control Peltier
method
Cooling function STC vial rack: Room temperature -15 C to room temperature
STC syringe holder: Room temperature -10 C to room
temperature

Example: When the room temperature is 25 C


STC vial rack: 10 to 25 C
STC syringe holder: 15 to 25 C
Heating function STC vial rack: Room temperature to room temperature + 35
C, maximum temperature 60 C
STC syringe holder: Room temperature to Room temperature
+ 35 C, maximum temperature 60 C

Example: When the room temperature is 25 C


STC vial rack: 25 to 60 C
STC syringe holder: 25 to 60 C
Example: When the room temperature is 35 C
STC vial rack: 35 to 60 C
STC syringe holder: 35 to 60 C
Injection system Gastight microsyringe (SGE)
Vertical furnace: 25, 50, 100, 250 L
Number of measuring 24 samples
samples

STC-500L (NSX-5000)
8-2 Specifications

Item Specifications
Vial rack STC 2 mL vial rack
STC 4 mL vial rack
STC 6 mL vial rack
Measuring vial 2 mL, 4 mL, 6 mL
capacity
Washing/waste 28 mL
solution vial capacity
Washing solution Pure water or organic solvent
Dimensions Temperature controller: About 220(W) x 375(D) x100(H) mm
Weight Temperature controller: About 4 kg
STC vial rack: About 2.7 kg
Power 100/115/230/240 VAC 50/60 Hz, 400 VA
Temperature 15 to 35 C
Humidity 80% RH or less (no condensation on the cooling part)
Overvoltage category CategoryⅡ (IEC61010-1)
Pollution degree 2 (IEC61010-1)

STC-500L (NSX-5000)
Guarantee Provisions 9-1

Section 9: Guarantee Provisions


9-1. Guarantee Provisions for Japan

Guarantee Terms
1. Guarantee period is one year from the date of delivery.
2. If the product is used in Japan and is used under normal usage during the
guarantee period and a problem occurs, Nittoseiko Analytech will repair
defective parts or replace them with new ones or equivalents free of charge.
The replaced old parts will be owned by Nittoseiko Analytech.
3. In the following cases, repairs will be charged even within the guarantee period:
(1) Failure due to improper handling or misuse
(2) Failure due to handling, use, storage, or breakage by storage that deviates
from the design and specification conditions
(3) Failure and damage due to transportation after delivery, dropping or
vibration during movement
(4) Failure caused by modification and repair by a person other than a
serviceman commissioned by the Company
(5) Replenishment of consumables and naturally consumed parts*
(6) Failure and damage due to accidental force such as fire, flood,
earthquakes, lightning, salt damage, abnormal voltage, and other natural
disasters
(7) Failure due to use in an environment outside the specifications
(8) Failure due to use with options and consumables other than certified
products
(9) Insufficient maintenance management of cleaning, maintenance,
inspection, and use of consumables other than those specified by the
Company.
(10) Other failures that are not considered to be our responsibility
* Items listed in " Consumables" at the end of the section are consumables.
4. Judgment as to whether or not failures correspond to free repair depends on
the company or a person commissioned by the company.
5. The contact for the failures shall be Nittoseiko Analytech or its agent.
6. Methods of returning defective products will be decided in consultation with the
contact place each time.

STC-500L (NSX-5000)
9-2 Guarantee Provisions

7. Nittoseiko Analytech does not make any express or implied guarantees


(including implied guarantees regarding merchantability or suitability for a
specific purpose) other than those expressly provided in the guarantee
provisions. Nittoseiko Analytech disclaims any guarantee anything other than
that stated in the guarantee provisions. Even if implied guarantees are applied
by law, they are limited to those specified in the guarantee provisions.
Guarantee Limitations
Nittoseiko Analytech is not liable for any damages (including lost profits and other
indirect damages) caused by the product or its use. Nittoseiko Analytech is not
responsible for any claims from third parties or the ones made by customers on
behalf of third parties.
These limitations shall apply regardless of whether the claim for damages or other
claims is based on the guarantee provisions, tort (including negligence and strict
liability), contractual claims or other causes of claims.
These limitations are valid even if Nittoseiko Analytech or its authorized agent is
aware of the possibility of such damage. However, they do not apply to damages
that Nittoseiko Analytech is liable for under the Product Liability Act.

STC-500L (NSX-5000)
Guarantee Provisions 9-3

9-2. Guarantee Provisions for Products Sold Overseas

Guarantee Terms
1. If you purchased a product from a Nittoseiko Analytech distributor outside
Japan, please contact the distributor for inquiries about the guarantee period
and terms as well as for failures.
Please note that Nittoseiko Analytech may not support even if you contact us
directly.
2. The preceding paragraph does not apply to inquiries regarding damages
(limited to those for which Nittoseiko Analytech may not be exempted in whole
or in part) related to Product Liability Act applicable to Nittoseiko Analytech.

STC-500L (NSX-5000)
9-4 Guarantee Provisions

STC-500L (NSX-5000)
Consumables 10-1

Section 10: Consumables


This section describes the consumables related to the STC-500L unit. For consumables
as a system, refer to the instruction manual of the target unit. For purchasing
consumables, contact our distributor.

10-1. STC-500L Consumables

Table 10-1 shows the STC-500L consumables.

Table 10-1. STC-500L Consumables List

No. Parts name Parts number Quantity Picture


1 Fuse 5A FU05MS 2 pcs/set

STC-500L (NSX-5000)
10-2 Consumables

STC-500L (NSX-5000)