Commissioning Report for Haivina Kim Lien


Generated on: 06/20/2024 00:03

Overview
Site: Haivina Kim Lien
Site ID: 1896438
Address: Đng 46A, Nam Dan, Vietnam,
475470
Account: Asia networks E&E
Installation Date: 11/07/2020
kWp DC: 959.2 kWp
kW AC: 745 kW

Performance
Period kWh kWh/kWp PR

Previous twelve months 981530.5 1023.3 84.94%

Lifetime 3386851.1 85.49%

Equipment
Device Model Quantity

Modules Q.PEAK L-G4.2 365 2626


Q.PLUS DOU L-G5.2 365 2

Total 2628

Optimizers P730-4RM4MRM-NM31 1303


P801-4RM4MRY-NM32 6
P801-4RM4MRM-NM31 1
P801-4RM4MRM-NA32 3
P801-4RM4MRY-NA32 1

Total 1314

Inverters SE82.8K-RW0P0BNU4 8
The resource of this report item is not reachable.

SE27.6K-RW000BNP4 1
SE55K-RW0P0BNU4 1

Total 10

Gateways 1
Sensors Ambient temperature 1
Global horizontal irradiance 1
Wind speed 1
Module temperature 1

Total 4

Layout
Verify the system is installed according to the design

Inverter Strings Optimizers Inverters Verify Notes


Models
1X 3 Strings 51 X 5
SE27.6K- X 17 P730-4RM4MRM-
RW000BNP4Optimizers NM31
1X 1 String X 92 X 8
SE55K- 14 P730-4RM4MRM-
RW0P0BNU4Optimizers NM31
5 Strings 1X
X 16 P801-4RM4MRM-
Optimizers NA32
1X
P801-4RM4MRY-
NA32
1X 1 String X 143 X 4
SE82.8K- 14 P730-4RM4MRM-
RW0P0BNU4Optimizers NM31
1 String X
15
Optimizers
5 Strings
X 16
Optimizers
2 Strings
X 17
Optimizers
2X 9 Strings 142 X 3,6
SE82.8K- X 16 P730-4RM4MRM-
RW0P0BNU4Optimizers NM31
2X
P801-4RM4MRY-
NM32
The resource of this report item is not reachable.

Inverter Strings Optimizers Inverters Verify Notes


Models
1X 9 Strings 143 X 10
SE82.8K- X 16 P730-4RM4MRM-
RW0P0BNU4Optimizers NM31
1X
P801-4RM4MRY-
NM32
2X 9 Strings 144 X 7,9
SE82.8K- X 16 P730-4RM4MRM-
RW0P0BNU4Optimizers NM31
1X 9 Strings 151 X 1
SE82.8K- X 17 P730-4RM4MRM-
RW0P0BNU4Optimizers NM31
1X
P801-4RM4MRM-
NM31
1X
P801-4RM4MRY-
NM32
1X 9 Strings 151 X 2
SE82.8K- X 17 P730-4RM4MRM-
RW0P0BNU4Optimizers NM31
2X
P801-4RM4MRM-
NA32

Communication Layout
Device S/N Communication (outbound)

Gateway 1 67006080-47 ethernet

Inverter 2 7E0B18E8-89 ethernet

Inverter 1 7E0B18CF-70 rs485

Inverter 4 7E0B18D2-73 rs485

Inverter 3 7E0B18D0-71 rs485

Inverter 5 7E0A6805-F5 rs485


The resource of this report item is not reachable.

Device S/N Communication (outbound)

Inverter 6 7E0B18D6-77 ethernet

Inverter 7 7B01B6B1-E3 rs485

Inverter 8 7E0AFBEE-71 rs485

Inverter 9 7E0B18D7-78 rs485

Inverter 10 7E0B18D4-75 rs485


The resource of this report item is not reachable.

Inverters
Verify that all inverters are configured as designed, running the correct firmware version and are performing properly
Name S/N Model Alert Severity Alert Description Error code Communicating Optimizers Country Name Communication Board DSP1 Version DSP2 Version Status kWp DC # Strings # Optimizers # Modules First Last telemetry Leader Communication Method Energy Storage mode Power AC power Isolation (KΩ Lifetime Last 12 Last month Verify Notes
(CPU) Version telemetry management Control limitation (%) ) Energy (kWh) months kWh/ kWh/kWp
Settings kWp
Inverter 1 7E0B18CF-70 SE82.8K- None NA NA 153 Vietnam 4.19.521 1.13.1822 2.19.1440 Sleeping 82.8 9 153 306 11/07/2020 06/19/2024 NA Disabled Disabled RRCR 100 423322.4 1998.3 630.7
RW0P0BNU4 11:07 20:49

Inverter 2 7E0B18E8-89 SE82.8K- None NA NA 153 Vietnam 4.19.521 1.13.2212 2.19.1806 Sleeping 82.8 9 153 306 11/07/2020 06/19/2024 Yes (RS485 leader) ETHERNET Disabled Disabled RRCR 100 423923.9 1960.7 603.7
RW0P0BNU4 11:09 20:49

Inverter 3 7E0B18D0-71 SE82.8K- None NA NA 143 Vietnam 4.19.521 1.13.2212 2.19.1806 Sleeping 82.8 9 144 288 11/08/2020 06/19/2024 NA Disabled Disabled RRCR 100 404618.5 1916.7 592.7
RW0P0BNU4 16:09 20:49

Inverter 4 7E0B18D2-73 SE82.8K- None NA NA 143 Vietnam 4.19.521 1.13.2212 2.19.1806 Sleeping 82.8 9 143 286 11/08/2020 06/19/2024 NA Disabled Disabled RRCR 100 401606.5 1900 586.3
RW0P0BNU4 16:16 20:49

Inverter 5 7E0A6805-F5 SE27.6K- None NA NA 51 Vietnam 4.19.521 1.13.2212 2.19.1806 Sleeping 27.6 3 51 102 11/12/2020 06/19/2024 NA Disabled Disabled RRCR 100 141188.4 2020.1 622.2
RW000BNP4 11:10 20:44

Inverter 6 7E0B18D6-77 SE82.8K- None NA NA 142 Vietnam 4.19.521 1.13.2212 2.19.1806 Sleeping 82.8 9 144 288 11/07/2020 06/19/2024 Yes (RS485 leader) ETHERNET Disabled Disabled RRCR 100 156912 1820.8 540.4
RW0P0BNU4 11:37 20:49

Inverter 7 7B01B6B1-E3 SE82.8K- None NA NA 144 Vietnam 4.18.518 1.13.2115 2.19.1700 Sleeping 82.8 9 144 288 10/02/2023 06/19/2024 NA Disabled Disabled RRCR 100 67467.1 814.7 585.8
RW0P0BNU4 16:29 20:49

Inverter 8 7E0AFBEE-71 SE55K- None NA NA 94 Vietnam 4.18.518 1.13.2115 2.19.1440 Sleeping 55 6 94 188 11/07/2020 06/19/2024 NA Disabled Disabled RRCR 100 251216.1 1867.6 580.8
RW0P0BNU4 11:27 20:44

Inverter 9 7E0B18D7-78 SE82.8K- None NA NA 143 Vietnam 4.18.514 1.13.2115 2.19.1700 Sleeping 82.8 9 144 288 11/07/2020 06/19/2024 NA Disabled Disabled RRCR 100 403998.8 1916.9 593.7
RW0P0BNU4 09:34 20:49

Inverter 10 7E0B18D4-75 SE82.8K- None NA NA 144 Vietnam 4.14.107 1.13.1822 2.19.1440 Sleeping 82.8 9 144 288 11/07/2020 06/19/2024 NA Disabled Disabled RRCR 100 407607.5 1932.6 604.9
RW0P0BNU4 09:24 20:49
The resource of this report item is not reachable.
The resource of this report item is not reachable.

Gateways
Verify that all gateways are configured as designed
Name SN Model Verify Notes

Gateway 1 67006080-47

You might also like