Download as pdf
Download as pdf
You are on page 1of 2
Republic of the Philippines DEPARTMENT OF LABOR AND EMPLOYMENT ON Occupational Safety and Health Center a, E semayrt North Avenue corner Agham Road, Diliman, Quezon City poate CCOFSCO REA SAFETY CONTROL DIVISION Revisor Nos 02 PE TESTING AND ASSESSMENT PROCEDURE efecive: February 22018 SAFETY SHOES TEST RESULTS Request Reference Code: PPE-SSHOES-2020-042 BRAND NAME [SUPERTUFF [TYPE SAFETY BOOTS DISTRIBUTOR ‘ADDRESS UNIVERSAL ELASTOMER INC. RIS INDUSTRIAL COMPLEX, MALIS, GUIGUINTO, BULACAN Shoe Size: ‘Toe Cap Matera: Injection Mod ‘Toe Cap Specifications: Mid-Solp Device Material: Goodyear Welt impact Resistance | Test Classification ee ven = Women Testing Standard: STEEL ‘Occupational Safety and Health Standards 128 amlengh 20 mmticiness | » Rule 1080: Personal Protective Equipment and Devices mm eight 7.8 mmfange Thickness _0.7_ mm 1-75 PASSED Specimen ‘Number (Compression Resistance Test Classification Interior Height Clearance After REMARKS 26.0 marks: Based on PNS-ASTM F2412:2016 and PNS ASTM F2413:2016 Safety Shoes Test Classification: Class 75 CRITERIA The specimen shall have a minimum interior height clearance equal o or greater tan he following: 12.7 mm{ormenis shoes and 11.9 mm for women's shoes CRITERIA ‘The specimen shal have a minimum interior height clearance ‘equal to or greater than the folowing: 4127 mmfor men's shoes and 11.9 mm for women's shoes 122.5 kgf 188 PASSED 192 The puncture redtnt device shal pss ifthe tp of tle pin does not visually penetrate beyond the face of the material rarest the fot, alr an applied force of 122.5 gt XK Page 1 of2 Republic of the Philippines DEPARTMENT, OF LABOR AND’ EMPLOYMENT In. @' Occupational Safety and Health Center Mittin. Pen North Avenue comer Agham Read, Diliman, Quezon City pee SAFETY CONTROL DIVISION Revision No.: 02 PPE TESTING AND ASSESSMENT PROCEDURE Effective: February 20, 2019 SAFETY SHOES TEST RESULTS Request Reference Code: _ PPE-SSHOES-2020-042. D. ELECTRICAL RESISTANCE TEST Electrically resistant protective footwear must be able to withstand an application of 18,000 volts for 1 minute wih no leakage currentin excess of 1 mA. Test voc TESTNOT CONDUCTED 1 Megaohm to 100 Megaohms ‘COMMENTS: ‘The specimens passed the requirements of PNS ASTM F 2413:2016 for Impact Resistance test, Compression Resistance test, Midsole Device Puncture Resistance test and Electrical, Resistance test: Page 2 of 2 Test Conducted By: Jat, MR. MARION A. VILLEGAS Engineering Assistant Approved By: Date: CA Kt 13 FEBRUARY 2020 ENGR. CONCEPCION T. STO. TOMAS Chief, Safety Control Division Executive Director

You might also like