Chromatography
2 3
Wide scope of
applications
5.5 180
sulfate
1.6
4.5
140
Conductivity [µS/cm]
120
3.5 0.8
sulfate
chloride
3.0 100
− ASTM D7359-14 Standard Test Method for − ASTM D8247 Standard Test Method for Deter-
2.5 80
0.0
2.0
bromide
Total Fluorine, Chlorine and Sulfur in Aromatic mination of Total Fluorine and Total Chlorine
0 2 4 6 8 10 12 14
60 Time [min]
1.5
1.0
40
chloride Hydrocarbons and their Mixtures by Oxidative in Coal by Oxidative Pyrohydrolytic Combustion
0.5 20
Pyrohydrolytic Combustion followed by Ion Followed by Ion Chromatography Detection
0.0
0 2 4 6 8 10 12 14 16 18 20
0
Chromatography Detection (Combustion Ion − ASTM D7994-17 Standard Test Method for Total
0 2 4 6 8 10 12 14 16 18 20
Time [min] Time [min] Chromatography-CIC) Fluorine, Chlorine, and Sulfur in Liquid Petroleum
− UOP991-13 Chloride, Fluoride, and Bromide Gas (LPG) by Oxidative Pyrohydrolytic Combustion
in Liquid Organics by Combustion Ion Chroma- Followed by Ion Chromatography Detection
Determination of halogens and sulfur in certified polyethylene Determination of halogens and sulfur in coal reference material
pellets ERM-EC681k: chloride: 102.4%, bromide 95.4%, sulfur NIST 2682b: chloride: 103.4%, sulfur 96.8%. Injection volume tography (CIC) (Combustion Ion Chromatography CIC)
100.3%. Injection volume 20 µL 100 µL
4 5
CIC automation – GLS SAMPLER CIC
For gaseous or LPG samples. The samples
sampling of
are gauged by a valve with sample loop,
after which it is introduced at a steady
speed into the oven unit using the Liquid
solid, liquid,
Introduction Module. Separate sample flow
paths for LPG and gas in the GLS Module
eliminate the risk of contamination.
and gaseous
compounds
SOLID AUTOSAMPLER CIC LIQUID AUTOSAMPLER CIC up to 420°C can be introduced into the SAFETY FIRST
For solid sample matrices. In the standard For liquid sample matrices. This auto Combustion Oven and evaporated at a Safety is paramount when it comes to
version, up to 20 samples can be automat- sampler has 30 sample positions plus an steady speed. The resulting gaseous com- handling highly flammable commodities
ically introduced into the oven unit. Sample additional position for a rinsing beaker. pounds are transferred into the Combus- such as liquefied gas. The GLS provides
capacity can be extended with additional The samples are introduced into the Com- tion Oven. As no sample cups are used in several safety features:
trays to up to 60 samples. The samples are bustion Oven either in dedicated sample version (b), there is no risk of incomplete − Automatic safety lock on inlet ports – this
introduced into the Combustion Oven in cups with the Boat Introduction Module combustion (soot or coke formation) and prevents the sample cylinder from being
sample cups via the Boat Introduction (a) or injected directly into the Liquid In- the reproducibility of results is improved. removed as long as there is pressure
Module. Depending on the nature of the troduction Module by means of a hollow Multiple injections from the same sample detected in the connection.
sample matrix, either quartz cups or ce- needle (b). With this Liquid Introduction can be digested and absorbed for the same − Internal gas leakage sensor – all system
ramic cups (for more aggressive matrices) Module, samples with a boiling point of analysis improving the detection limit. activity is automatically aborted, and
are used. the operator alerted when any hydro-
carbon spill is detected.
− Auto-shutoff inlet ports. The auto-shut-
off mechanism stops any gas flow due
to a dedicated valve when it is discon-
nected. When both the male coupling
and the female plug have a shutoff
valve, a double-ended shutoff connec-
tion is established.
− Gas or LPG is only consumed from the
cylinders during sampling.
a b
6 7
Wide scope
of applications STRAIGHTFORWARD OPERATION
The Metrohm CIC system is controlled by the
MagIC Net software. The system is switched off
STRAIGHTFORWARD CALIBRATION
Thanks to the Metrohm intelligent Partial Loop
Injection Technique (MiPT), the system is calibrated
or set to stand-by mode after a determination fully automatically using a single multi-ion standard.
series. This feature saves costs, e.g., when This saves time and helps prevent errors.
analyzing expensive gases.
Liquid Autosampler CIC, Solid Autosampler CIC, Combustion Oven (TEI) 920 Absorber Module 930 Compact IC Flex GLS Sampler CIC
8 9
Perfect liquid handling – Straightforward control
the 920 Absorber Module with MagIC Net software
In the Metrohm CIC System the combustion module The following items are available for the entire liquid The CIC system from Metrohm is controlled by
and ion chromatograph are linked together by the handling: a 10-port valve, a 6-port injection valve MagIC Net software for ion chromatography while
920 Absorber Module. The 920 Absorber Module and two patented Metrohm 800 Dosinos with the sampling modules and the oven unit are con-
ensures that the gaseous compounds of the analytes Dosing Units. The 920 Absorber Module can also be trolled by the TEIS Software. Dedicated monitoring
are brought into solution. The professional liquid used as a semi-online sampler for direct absorption and control functions are available to the user.
handling also includes the input of water for com- of gas compounds (NH3, HNO2, HNO3, HCl, SO2) MagIC Net meets all FDA and GLP requirements
bustion, matrix elimination of the hydrogen perox- from the air. In this way, for example, volatile organic and is available in numerous languages. A modern
ide (oxidizing agent), and rinsing procedures. acids (hydrochloric acid, sulfuric acid) can be moni- data management system and a powerful report
tored in process flue gases or in the ambient air at generator round off the package.
Moreover, a single multi-ion standard may be used workplaces.
for an automated calibration of the system by means MagIC Net guarantees simple, robust, and reliable
of the Metrohm intelligent Partial Loop Injection management of the system. The user is always able
Technique (MiPT). Because MiPT allows flexible to keep track of all samples that are introduced into
injection volumes (4–200 μL), a large concentration the absorption solution. Due to this it is possible
range can be covered. to work without an internal standard or other tools.
10 11
ORDERING INFORMATION
Instrument
Metrohm markets the complete system, including installation, service and training −
all from the same supplier.
Combustion IC sets
Introduction Modules
Autosamplers
www.metrohm.com