Technical features
Medium: Display: Weight: Materials:
Compressed air (filtered/lubricated/ Alphanumeric display, 4-digit (red/ 0,087 kg (0.19 lbs) Housing:
non-lubricated) green), programmable pressure Temperature sensitivity: PBT, FKM, Polyester
Pressure range: units: bar, kPa, psi, inHg Zero-point: ±0,2% of maximum Wetted parts: Brass, FKM, Silicon
- 1 ... 1 bar (-14,5 … 14,5 psi) Mounting position: operating pressure range (FS) per (coated), PBT
- 1 … 10 bar (-14,5 … 145 psi) Optional 10 Kelvin
0 … 16 bar (0 … 232 psi) Total accuracy: Pressure range: ±0,2% of
Pressure type: ±0,5% of full scale (FS) - without maximum operating pressure range
Relative, and option for differential temperature sensitivity (FS) per 10 Kelvin (at 0 ... 60°C)
pressure Linearity: Ambient/Media temperature:
Switching pressure difference: ±0,25% + 1 display step size Ambient:
Programmable Shock proof: 0 ... +70°C (+32 ... +158°F)
Switching point: 50 g, (11ms), DIN EN 60068-2-27 Media:
Adjustable between Vibration proof: 0 ... +70°C (+32 ... +158°F)
0 ... 100% of full scale (FS) 20 g, 10 ... 2000 Hz, Air supply must be dry enough
Reset point: DIN EN 60068-2-6 to avoid ice formation at
Adjustable between Degree of protection acc. temperature below +2°C (+35°F)
0 ... 100% of full scale (FS) DIN EN 60529:
(smallest adjustable pressure IP65
switching difference between
switching point and reset point
≥ 0,5% of full scale (FS))
Electronic features
Electrical connection: Switching mode: Switching time: Operating mode:
M8 PNP < 6 ms Hysteresis and
Power supply: Output signal: Adjustable signal delay dS, dr[s]: window mode separately
UB = 18 …32 VDC Switching signal; IO-Link 0; 0,002 … 5 selectable for each output
reverse-polarity protected (configurable) Service life: Electromagnetic compatibility:
(according to EN 50178 SELV/ Contact rating: Min. 50 million switching cycles EN 61000-6-2; EN 61000-6-3
PELV) Imax VDC = 100 mA Switching logic:
Permissible residual ripple: NO/NC programmable
10% (within UB)
Current consumption:
< 50 mA
Our policy is one of continued research and development. We therefore reserve the right to amend, 9/19
without notice, the specifications given in this document. (2019 - 9266a) © 2015 Norgren GmbH en 5.11.486.01
54D
Pneumatic - electronic pressure sensor
Accessories
Connector M8 x 1 DIN-Railclip
Our policy is one of continued research and development. We therefore reserve the right to amend,
en 5.11.486.02 without notice, the specifications given in this document. (2019 - 9266a) © 2015 Norgren GmbH 9/19
54D
Pneumatic - electronic pressure sensor
11,3
20,7
1
2
42
35
20 32
4.75
ø4,2
30
Dimensions accessories
DIN-Railclip
54D-DINRAIL-CLIP
30
13
36,9
EN - Englisch
Warning
These products are intended for use in industrial compressed air and fluid Through misuse, age, or malfunction, components used in fluid power
systems only. Do not use these products where pressures and systems can fail in various modes. The system designer is warned to
temperatures can exceed those listed under »Technical features/data«. consider the failure modes of all component parts used in fluid power
Before using these products with fluids other than those specified, for systems and to provide adequate safeguards to prevent personal injury
non-industrial applications, life-support systems, or other applications not or damage to equipment in the event of such failure.
within published specifications, consult System designers must provide a warning to end users in the system
IMI Precision Engineering, Norgren GmbH. instructional manual if protection against a failure mode cannot be
adequately provided.
System designers and end users are cautioned to review specific warnings
found in instruction sheets packed and shipped with these products.
Our policy is one of continued research and development. We therefore reserve the right to amend,
9/19 without notice, the specifications given in this document. (2019 - 9266a) © 2015 Norgren GmbH en 5.11.486.03