SITE PLAN, G+6 Mixed Use Abera Lisanu Building-Model

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Number Date Amendment Description

REVISION

AR SELAM ARCHITECTS AND

10
CH ENGINEERING CONSULTANCY

00
ITE

M
CT PLC.

LA
S

SE
LOCATION;
LEGEND
& HAWASSA SIDAMA
ETHIOPIA
Tel:
1-MAIN ROAD 0462127346,
EN
2-MAIN GATE GIN EER ING +251-916067138
N 3-MAIN BUILDING
+251-961047689
E-Mail Selamconsultingplc@yahoo.co m
4-WATER TANK 8

00

1
25
5-GREEN AREA In Case of any confusion in the dimensions
6- PARKING of structural elements such as Column size,

10
7-SEPTIC TANK Beam Size, Slab Thickness, Lintel size ETC,
The Measurements Given In Structural

36
27

0
8-FUTURE EXPANTION

2
25
5
33
4 Drawings Has To Be Followed:

10
8
Confidentiality Issues:

57
19

3
05

5
1

8
90
29
It's a Production Of

25230
0
30
20
5 SELAM ARCHITECTURAL AND ENGINEERING

25
0
CONSULTANCY PLC. This Company Owns The
4

0
25
copyright To this Drawing, Which is Strictly

8
8 Prohibited To Be Copied, Reproduced or

A=

4
28

27

5 3
Disclosed to A Third Party Without The Written

1
29

60
Permission.

7
33

1
5

28
3

10
99 Project Type

8
8
G+6 MIXED USE
10

10
4
10
69
BUILDING

0
25
90

10
20

A
7
89
27

0
5

60
10

6 69
Project Status

85
9
10
52
New Modification As-Built

11
10
36

1
0

9
A=

0 2
49

37
.30
5

3
20

16

B
U 19
2
10
0 2 P 05

30
0

7
919
25
0

12
No Revisions Date Signature

10
27

1
29
69
2
8

9
90 5

38
27

C
30

68
6

8
15
1
5
10
OWNER
7
34
0

D
Drawing Type

ARCHITECTURAL DRAWING
SITE PLAN
SCALE 1:200 Date
CITY-----Hawassa MAY. 2024
SITE AREA=500M X 200M =1000M² SUBCITY---Addiss Ketema
KEBELE---- Filadelfiya

CHECKE BY Signature
BENIAM ALEMAYEHU PPAR/2931

Des.Team
ZEKARIAS TESFAYE.....

Drwn.by
BEREKET BARKLIGN.....GE ARCH/0033

NOTE - Internal wall of all wet cores is cladded with 2mm ceramic to a height of 200cm.
Color and pattern of ceramic will be decided by the Architect Drawing No SCALE
- All Architectural drawings shall be seen compatible to other engineering designs
- All dimensions are in cm unless specified
like structural, electrical and sanitary. 1:100
- All accessories shall be of the best quality and to be approved by the engineer/architect!
- Dimensions shall be read from drawings and not be measured. - Door openings direction shall be as shown on floor plans.
- All doors and door window combinationsdo have a threshold of 30cm wide and
3cm thick in white Wolega marble.
- Actual measurement of door & window should be taken on site.
- All hinges, locks, springs, lashes shall be ASSA type complying to ASTM standards & approved by
12/12 AR
- Use plastic door stoppers fixed to the floor at proper location approved by the engineer. the Architect prior to fixing.

You might also like