Professional Documents
Culture Documents
SITE PLAN, G+6 Mixed Use Abera Lisanu Building-Model
SITE PLAN, G+6 Mixed Use Abera Lisanu Building-Model
SITE PLAN, G+6 Mixed Use Abera Lisanu Building-Model
REVISION
10
CH ENGINEERING CONSULTANCY
00
ITE
M
CT PLC.
LA
S
SE
LOCATION;
LEGEND
& HAWASSA SIDAMA
ETHIOPIA
Tel:
1-MAIN ROAD 0462127346,
EN
2-MAIN GATE GIN EER ING +251-916067138
N 3-MAIN BUILDING
+251-961047689
E-Mail Selamconsultingplc@yahoo.co m
4-WATER TANK 8
00
1
25
5-GREEN AREA In Case of any confusion in the dimensions
6- PARKING of structural elements such as Column size,
10
7-SEPTIC TANK Beam Size, Slab Thickness, Lintel size ETC,
The Measurements Given In Structural
36
27
0
8-FUTURE EXPANTION
2
25
5
33
4 Drawings Has To Be Followed:
10
8
Confidentiality Issues:
57
19
3
05
5
1
8
90
29
It's a Production Of
25230
0
30
20
5 SELAM ARCHITECTURAL AND ENGINEERING
25
0
CONSULTANCY PLC. This Company Owns The
4
0
25
copyright To this Drawing, Which is Strictly
8
8 Prohibited To Be Copied, Reproduced or
A=
4
28
27
m²
5 3
Disclosed to A Third Party Without The Written
1
29
60
Permission.
7
33
1
5
28
3
10
99 Project Type
8
8
G+6 MIXED USE
10
10
4
10
69
BUILDING
0
25
90
10
20
A
7
89
27
0
5
60
10
6 69
Project Status
85
9
10
52
New Modification As-Built
11
10
36
1
0
9
A=
0 2
49
37
.30
5
3
20
m²
16
B
U 19
2
10
0 2 P 05
30
0
7
919
25
0
12
No Revisions Date Signature
10
27
1
29
69
2
8
9
90 5
38
27
C
30
68
6
8
15
1
5
10
OWNER
7
34
0
D
Drawing Type
ARCHITECTURAL DRAWING
SITE PLAN
SCALE 1:200 Date
CITY-----Hawassa MAY. 2024
SITE AREA=500M X 200M =1000M² SUBCITY---Addiss Ketema
KEBELE---- Filadelfiya
CHECKE BY Signature
BENIAM ALEMAYEHU PPAR/2931
Des.Team
ZEKARIAS TESFAYE.....
Drwn.by
BEREKET BARKLIGN.....GE ARCH/0033
NOTE - Internal wall of all wet cores is cladded with 2mm ceramic to a height of 200cm.
Color and pattern of ceramic will be decided by the Architect Drawing No SCALE
- All Architectural drawings shall be seen compatible to other engineering designs
- All dimensions are in cm unless specified
like structural, electrical and sanitary. 1:100
- All accessories shall be of the best quality and to be approved by the engineer/architect!
- Dimensions shall be read from drawings and not be measured. - Door openings direction shall be as shown on floor plans.
- All doors and door window combinationsdo have a threshold of 30cm wide and
3cm thick in white Wolega marble.
- Actual measurement of door & window should be taken on site.
- All hinges, locks, springs, lashes shall be ASSA type complying to ASTM standards & approved by
12/12 AR
- Use plastic door stoppers fixed to the floor at proper location approved by the engineer. the Architect prior to fixing.