Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 1

CIVIL ENGINEERING DEPARTMENT

TRANSPORTATION ENGINEERING LABORATORY

No. CED/TEL/MT/ /17-18 Date :- 16/05/2017


MATERIAL TESTING REPORT

1. Ref No. : AAI/SAP/A.G.M (E-C)-II/Extn of Runway/Testing/Mould/2016-17/


Dtd :- 01-04-2017
2. Name of Client : M/s. AGM (Engg- C)-II, Surat Airport Project, Surat.
4. Name of Agency : M/s. Relcon Infra Projects Ltd.
3. Report for : Test on Moulds of DAC
5. Name of Work : Re-Carpeting / Strengthening & Extension of Runway 04/22 at Surat
Airport, Surat.
6. Test Results :
Mix Parameters *

Sample Bulk specific gravity Stability at Flow at Va, VFB,


Date Gmm
No. of mould (Gmb) 60˚C, kN 60˚C, mm % %

1. 2.389 13.95 3.90 2.485 3.86 74.22


30-03-2017

2. 2.387 14.26 3.65 2.487 4.02 73.30


3. 2.385 13.15 3.85 2.486 4.06 73.15
1. 2.384 14.18 3.58 2.487 4.14 72.69
31-03-2017

2. 2.383 14.95 3.98 2.485 4.10 73.00


3. 2.386 14.10 4.12 2.485 3.98 73.61
Note:- The test results are based on the Moulds supplied by the client at the Transportation Engineering laboratory SVNIT, Surat.

(A.J. Solanki) (Dr. Rakesh Kumar)


Assistant Professor & Associate Professor &
TE- Lab in Charge, CED TE- Lab in Charge, CED Forwarded by
(Dr. J.E.M. Macwan)
Prof.& Head, CED