GENERAL NOTES
1. CONTRACTORS SHOULD VERIFY ALL SITE
DIMENSIONS.

2. CONTRACTORS ARE RESPONSIBLE FOR NOTIFYING


A B C A B C 612 ARCHITECTURE IF CONFUSION ARISES ON SITE
OR IF DIMENSIONS AND/OR DETAILS ARE MISSING
FROM DRAWING SET BEFORE PROCEEDING AT SITE.
8000 8000
A 3. NO PART OF THIS WORK MAY BE REPRODUCED OR
2550 1700 1200 2550 2550 2900 2550 USED IN ANY FORM OR BY ANY MEANS WITHOUT
WRITTEN PERMISSION FROM THE PUBLISHER.

4. ALL PRINTS, SPECIFICATIONS AND THEIR


COPYRIGHTS ARE PROPERTIES OF 612
1 1 ARCHITECTURE AND SHALL BE RETURNED UPON
COMPLETION OF WORK.

OPEN 5. DO NOT SCALE OR ALTER DRAWINGS WITHOUT


2000

2000

2000

2000
OPEN AREA BELOW INFORMING AND GETTING APPROVAL FROM 612
T&B T&B MASTER T&B ARCHITECTURE.
LEDGE LINE
6. DETAIL DRAWINGS ARE SUBJECT FOR DESIGN
INTENTION ONLY. CONTRACTOR OR SUPPLIER
2 2 SHOULD PROVIDE INDIVIDUAL SHOP DRAWINGS FOR
COUNTER CHECKING

5560
AREA: VOLUME: *Pi = 3.1416
L a
b2 1
a h
= (L)(w) = a³ = 3 (b)(h)
2600

w h= (h/2)(b1+b2)
a b
b1
7000

c h 1 1
= a² h
= (b)(h) = (Pi)(r²) b = (a)(b(c) r = (b)(h) = 3 (Pi)(r²)(h)
3
b a b
B BEDROOM 02

3560

3560

3560
MASTER

TV
1
KITCHEN = (Pi)(r1)(r2)
h = 2 (b)(h)
=
4
3(Pi)(r³) =
4
3(Pi)(r1)(r2)(r3)
BEDROOM
b

CLINIC GAUGE THICKNESS: STRANDED WIRE:


Ga. 14 - 2.0mm 2.0 mm² - #14 14.0 mm² - #6
Ga. 16 - 1.6mm 100.0 mm² - #4/0
3.5 mm² - #12 22.0 mm² - #4
Ga. 18 - 1.4mm 125.0 mm² - #250
5.5 mm² - #10 30.0 mm² - #2
Ga. 20 - 1.0mm 175.0 mm² - #300
8.0 mm² - #8 50.0 mm² - #1/0
Ga. 22 - 0.8mm 200.0 mm² - #350
60.0 mm² - #2/0
Ga. 24 - 0.6mm 250.0 mm² - #400
80.0 mm² - #3/0
Ga. 26 - 0.5mm 325.0 mm² - #500
Ga. 28 - 0.4mm

3 3 INCHES - MM CONVERSION OF REBARS @ 1000 MM.


2400

1/8" - 3.0mm 3/8" - 10.0mm 1" - 25.0mm SIZE KG/M. SIZE KG/M.
3/16" - 4.5mm 1/2" - 12.0mm 1-1/8" - 28.0mm 10mm. Ø = 0.616 kg. 28mm. Ø = 4.834 kg.
12500

12500

12500

12500
1240

1240
1/4" - 6.0mm 5/8" - 16.0mm 1-1/4" - 32.0mm 12mm. Ø = 0.888 kg. 32mm. Ø = 6.313 kg.
5/16" - 8.0mm 3/4" - 20.0mm 1-3/8" - 34.0mm
FOYER 7/8" - 22.0mm 1-1/2" - 36.0mm
16mm. Ø = 1.578 kg.
20mm. Ø = 2.466 kg.
36mm. Ø = 7.990 kg.

25mm. Ø = 3.853 kg.

UP DN UP CONVERSION:
1 foot = 12 inches 1 cubic meter = 35.31 cubic feet
1 foot = 0.31 meters 1 cubic meter = 61,024 cubic inches
1 meter= 3.28 feet 1 cubic meter = 1,000 liters
1 meter= 39.37 inches 1 cubic meter = 264.17 gallons
1 sq.ft. = 144 sq.inches 1 cubic foot = 0.03 cubic meters
1 sq.ft. = 0.09 sq.meters 1 cubic foot = 1.728 cubic inches
1 sq.m.= 10.76 sq.ft. 1 cubic foot = 28.32 liters
1 sq.m.= 1,550 sq.inches 1 cubic foot = 7.48 gallons

C LEGEND

5890
3500

3500
PATTERN DESCRIPTION

DINING AREA LIVING AREA CONCRETE COLUMN

WALL FINISHING MATERIALS

PATTERN DESCRIPTION PATTERN DESCRIPTION


GARAGE
5500

200 MM THK PLAIN


CEMENT PLASTERED
150mm THK. DRYWALL
CHB WALL
PARTITION W/ 12" THK.
150 MM THK PLAIN HARDIFLEX ON 1" X 1" METAL
STUDS IN PAINT FINISH,
CEMENT PLASTERED
4 4 CHB WALL
COLOR AS PER ARCHITECT'S
APPROVED SAMPLE, TYP.,
U.N.O.
GLASS WALL

ELECTRICAL -ALL BREAKER BRANCHES


SHOULD HAVE ONLY ONE LINE
2200

2200
- BREAKER TEMPERATURE :
NOT MORE THAN 40°C. TERMINATION.
- LOGS SCREW SHOULD BE -NO PIPING SHOULD BE FORCE
TIGHT AND APPLY LUBRICANT TO BEND OR ALL PIPING

1050
IF NEEDED. SHOULD RUN IN A SMOOTH
- ALL PANEL BOARDS MUST MANNER.
HAVE INSULATION (MEAGER) -NO WET SUPPLY SHOULD BE
TEST BEFORE TURNOVER. INSTALLED PARALLEL TO
- CHECK WIRE LOAD IF IT ELECTRICAL.
COINCIDES WITH BREAKER -ALL PIPES CROSSING
LOAD. THROUGH BEAMS, WALLS, &
D - LIGHT LUMENS : AT LEAST OTHER SURFACES SHOULD BE
PROVIDED WITH SLEEVES.
ROAD E
S
E
S 260-300 LUMENS @ 5FT.
HIGH OR EYE LEVEL. -ALL PIPES & WIRES SHOULD
- GEN SET : VENTILATION AT HAVE PROPER & SUFFICIENT
LEAST 2 SIDES. LENGTH & PROPERLY SEALED.
- ALL BREAKER SHOULD BE -ALL ELECTRICAL FIXTURE
5600 2400 W 1600 4200 2200 W LABELED & WELL
VENTILATED.
SHOULD BE PROPERLY
INSTALLED, FIXED, ALIGNED, &
N N - ALL WIRES, DEVICES & SAFE.
BOXES SHOULD HAVE PROPER
8000 8000 ENCLOSURE, HANGER, AUXILLARY
COVER, SUPPORT/CLAM, & -VOICE & DATA WIRING NO
HARNESS SPLICE ALLOWED.

ROOFING & GUTTER NOTES:


· Gutter use Stainless Steel 304 GA 24 w/ Brass Roof
Strainer.

01 GROUND FLOOR PLAN 02 SECOND FLOOR PLAN · Prior to installation of roof all Roof Framing must be
well-painted with Red Oxide Top coat w/ Boysen QDE
Paint.
A-02 SCALE 1:50 MTS. A-02 SCALE 1:50 MTS. · Using G.I. corrugated .6mm thk. w/10mm thermal
insulation double to be supplied and installed by
Contractor.
· All accessories like tekscrew, blind rivets and others must
be treated with Water Proofing supplied & installed by
Contractor

DRAWING TITLE/S PROJECT STATUS SCALE

AS SHOWN
RA 9266 (ARCHITECTURE LAW 2004) SEC. 33 : AR. COLEEN MAE B. GONO UAP MS. PRECIOUS RELLES AS SHOWN PROJECT START DATE DRAWN BY CHECKED BY
ARCHITECT CLIENT / OWNER
DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED OR
SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY AND DOCUMENT OF THE
ARCHITECT, WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. IT SHALL BE PRC NO. 0043931 PTR NO. 4388771 PROJECT NAME ARCH. ENGR. DWG. NO.
UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE
REPETITION OF AND FOR OTHER PROJECTS OF BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, VALIDITY 12 JUNE 2024 DATE ISSUED 24JAN2023 PROPOSED THREE-STOREY RESIDENCE WITH ROOF DECK CMG A-02
WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
IAPOA NO. 41142 395858 071723 PLACE ISSUED MUNTINLUPA.CITY PROJECT LOCATION QA / QC PM PROJ. NO. REV. NO.
E-mail : 612architecture@gmail.com Imus, Cavite
DATE ISSUED 17JUL2023 TIN NO. 486714008 BLK 34 LOT 7 EP VILLAGE WESTERN BICUTAN, TAGUIG CITY

You might also like