Professional Documents
Culture Documents
TAGUIG-w-CLINIC_091923-Layout1 (1)
TAGUIG-w-CLINIC_091923-Layout1 (1)
GENERAL NOTES
1. CONTRACTORS SHOULD VERIFY ALL SITE
DIMENSIONS.
2000
2000
2000
OPEN AREA BELOW INFORMING AND GETTING APPROVAL FROM 612
T&B T&B MASTER T&B ARCHITECTURE.
LEDGE LINE
6. DETAIL DRAWINGS ARE SUBJECT FOR DESIGN
INTENTION ONLY. CONTRACTOR OR SUPPLIER
2 2 SHOULD PROVIDE INDIVIDUAL SHOP DRAWINGS FOR
COUNTER CHECKING
5560
AREA: VOLUME: *Pi = 3.1416
L a
b2 1
a h
= (L)(w) = a³ = 3 (b)(h)
2600
w h= (h/2)(b1+b2)
a b
b1
7000
c h 1 1
= a² h
= (b)(h) = (Pi)(r²) b = (a)(b(c) r = (b)(h) = 3 (Pi)(r²)(h)
3
b a b
B BEDROOM 02
3560
3560
3560
MASTER
TV
1
KITCHEN = (Pi)(r1)(r2)
h = 2 (b)(h)
=
4
3(Pi)(r³) =
4
3(Pi)(r1)(r2)(r3)
BEDROOM
b
1/8" - 3.0mm 3/8" - 10.0mm 1" - 25.0mm SIZE KG/M. SIZE KG/M.
3/16" - 4.5mm 1/2" - 12.0mm 1-1/8" - 28.0mm 10mm. Ø = 0.616 kg. 28mm. Ø = 4.834 kg.
12500
12500
12500
12500
1240
1240
1/4" - 6.0mm 5/8" - 16.0mm 1-1/4" - 32.0mm 12mm. Ø = 0.888 kg. 32mm. Ø = 6.313 kg.
5/16" - 8.0mm 3/4" - 20.0mm 1-3/8" - 34.0mm
FOYER 7/8" - 22.0mm 1-1/2" - 36.0mm
16mm. Ø = 1.578 kg.
20mm. Ø = 2.466 kg.
36mm. Ø = 7.990 kg.
UP DN UP CONVERSION:
1 foot = 12 inches 1 cubic meter = 35.31 cubic feet
1 foot = 0.31 meters 1 cubic meter = 61,024 cubic inches
1 meter= 3.28 feet 1 cubic meter = 1,000 liters
1 meter= 39.37 inches 1 cubic meter = 264.17 gallons
1 sq.ft. = 144 sq.inches 1 cubic foot = 0.03 cubic meters
1 sq.ft. = 0.09 sq.meters 1 cubic foot = 1.728 cubic inches
1 sq.m.= 10.76 sq.ft. 1 cubic foot = 28.32 liters
1 sq.m.= 1,550 sq.inches 1 cubic foot = 7.48 gallons
C LEGEND
5890
3500
3500
PATTERN DESCRIPTION
2200
- BREAKER TEMPERATURE :
NOT MORE THAN 40°C. TERMINATION.
- LOGS SCREW SHOULD BE -NO PIPING SHOULD BE FORCE
TIGHT AND APPLY LUBRICANT TO BEND OR ALL PIPING
1050
IF NEEDED. SHOULD RUN IN A SMOOTH
- ALL PANEL BOARDS MUST MANNER.
HAVE INSULATION (MEAGER) -NO WET SUPPLY SHOULD BE
TEST BEFORE TURNOVER. INSTALLED PARALLEL TO
- CHECK WIRE LOAD IF IT ELECTRICAL.
COINCIDES WITH BREAKER -ALL PIPES CROSSING
LOAD. THROUGH BEAMS, WALLS, &
D - LIGHT LUMENS : AT LEAST OTHER SURFACES SHOULD BE
PROVIDED WITH SLEEVES.
ROAD E
S
E
S 260-300 LUMENS @ 5FT.
HIGH OR EYE LEVEL. -ALL PIPES & WIRES SHOULD
- GEN SET : VENTILATION AT HAVE PROPER & SUFFICIENT
LEAST 2 SIDES. LENGTH & PROPERLY SEALED.
- ALL BREAKER SHOULD BE -ALL ELECTRICAL FIXTURE
5600 2400 W 1600 4200 2200 W LABELED & WELL
VENTILATED.
SHOULD BE PROPERLY
INSTALLED, FIXED, ALIGNED, &
N N - ALL WIRES, DEVICES & SAFE.
BOXES SHOULD HAVE PROPER
8000 8000 ENCLOSURE, HANGER, AUXILLARY
COVER, SUPPORT/CLAM, & -VOICE & DATA WIRING NO
HARNESS SPLICE ALLOWED.
01 GROUND FLOOR PLAN 02 SECOND FLOOR PLAN · Prior to installation of roof all Roof Framing must be
well-painted with Red Oxide Top coat w/ Boysen QDE
Paint.
A-02 SCALE 1:50 MTS. A-02 SCALE 1:50 MTS. · Using G.I. corrugated .6mm thk. w/10mm thermal
insulation double to be supplied and installed by
Contractor.
· All accessories like tekscrew, blind rivets and others must
be treated with Water Proofing supplied & installed by
Contractor
AS SHOWN
RA 9266 (ARCHITECTURE LAW 2004) SEC. 33 : AR. COLEEN MAE B. GONO UAP MS. PRECIOUS RELLES AS SHOWN PROJECT START DATE DRAWN BY CHECKED BY
ARCHITECT CLIENT / OWNER
DRAWINGS AND SPECIFICATIONS AND OTHER CONTRACT DOCUMENTS DULY SIGNED, STAMPED OR
SEALED, AS INSTRUMENTS OF SERVICE, ARE THE INTELLECTUAL PROPERTY AND DOCUMENT OF THE
ARCHITECT, WHETHER THE OBJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. IT SHALL BE PRC NO. 0043931 PTR NO. 4388771 PROJECT NAME ARCH. ENGR. DWG. NO.
UNLAWFUL FOR ANY PERSON TO DUPLICATE OR TO MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE
REPETITION OF AND FOR OTHER PROJECTS OF BUILDINGS, WHETHER EXECUTED PARTLY OR IN WHOLE, VALIDITY 12 JUNE 2024 DATE ISSUED 24JAN2023 PROPOSED THREE-STOREY RESIDENCE WITH ROOF DECK CMG A-02
WITHOUT THE WRITTEN CONSENT OF ARCHITECT OR AUTHOR OF SAID DOCUMENTS.
IAPOA NO. 41142 395858 071723 PLACE ISSUED MUNTINLUPA.CITY PROJECT LOCATION QA / QC PM PROJ. NO. REV. NO.
E-mail : 612architecture@gmail.com Imus, Cavite
DATE ISSUED 17JUL2023 TIN NO. 486714008 BLK 34 LOT 7 EP VILLAGE WESTERN BICUTAN, TAGUIG CITY