VarnishElimination Unit-

Filtration
VEU-F-60/1-x-C…

Operating and Maintenance Instructions


English (translation of original instructions)

Keep for future reference.

Document No.: 4104528a


Imprint

Imprint
Publisher and responsible for the content:
HYDAC FILTER SYSTEMS GMBH
Postfach 1251
66273 Sulzbach / Saarland
Germany
Phone: +49 6897 509 01
Fax: +49 6897 509 9046
E-mail: filtersystems@hydac.com
Homepage: www.hydac.com

Court of Registration: Saarbrücken, HRB 17216


Executive director: Mathias Dieter,
Dipl.Kfm. Wolfgang Haering

Documentation Representative
Mr. Günter Harge
c/o HYDAC International GmbH, Industriegebiet, 66280 Sulzbach / Saar
Phone: +49 6897 509 1511
Fax: +49 6897 509 1394
E-mail: guenter.harge@hydac.com

© HYDAC FILTER SYSTEMS GMBH


All rights reserved. No part of this work may be reproduced in any form (print,
photocopy or by other means) or processed, duplicated or distributed using
electronic systems without the written consent of the publisher.
These documents have been created and inspected with the greatest care.
However, errors cannot be ruled out completely.
All details are subject to technical modifications. Technical specifications are
subject to change without notice.

VEU-F-60/1-x-C… en(us) Page 2 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Content

Content
Imprint............................................................................................................ 2
Documentation Representative ................................................................... 2
Content .......................................................................................................... 3
Preface ........................................................................................................... 5
Technical Support ........................................................................................ 5
Modifications to the Product ........................................................................ 5
Warranty ...................................................................................................... 5
Using the documentation ............................................................................. 6
Safety Information ........................................................................................ 7
Signal words and their meaning in the general safety information............... 7
Structure of the general safety information .................................................. 8
Hazard symbols ........................................................................................... 8
Observe regulatory information ................................................................... 9
Proper/designated use............................................................................... 10
Improper Use or Use Deviating from Intended Use ................................... 10
Qualifications of personnel / target group .................................................. 12
Wear suitable clothing ............................................................................... 14
Stoppage in an emergency (EMERGENCY STOP)................................... 14
Transporting the unit .................................................................................. 14
Storing the unit ........................................................................................... 16
Decoding the model code label ................................................................. 17
Checking the scope of delivery ................................................................. 19
Characteristics of the unit .......................................................................... 20
VEU-F components ..................................................................................... 21
Dimensions ................................................................................................ 23
Hydraulic diagram ...................................................................................... 25
Setting up / Installing VEU-F ...................................................................... 27
Notes on pipes and hoses ......................................................................... 28
Connecting the suction port - INLET .......................................................... 29
Connecting the pressure port - OUTLET ................................................... 29
Preparing the RFCS side cooler ................................................................ 29
Electrical connection of the unit ................................................................. 30
Checking direction of rotation ................................................................. 30
Starting up the unit ..................................................................................... 31
Switching on/operating the unit.................................................................. 32
"Error" signal lamp lights up ................................................................... 32
"Filter contaminated" signal lamp lights up ............................................. 32

VEU-F-60/1-x-C… en(us) Page 3 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Content

"Tray overflow" signal lamp lights up ...................................................... 33


Checking the temperature setting on the side cooler................................. 33
Switching off the unit ................................................................................. 33
Performing maintenance ............................................................................ 34
Maintenance of the side cooler .................................................................. 34
Changing filter element(e) ......................................................................... 35
Clean the suction strainer .......................................................................... 40
Cleaning / Flushing the plate heat exchanger on the cooling water
side ............................................................................................................ 42
Exchanging / Replacing plate heat exchanger........................................... 42
Errors and eliminating errors..................................................................... 43
Taking the unit out of operation ................................................................ 44
Disposing of the unit .................................................................................. 44
Finding spare parts..................................................................................... 45
Technical Data............................................................................................. 48
Attachment .................................................................................................. 50
Model code ................................................................................................ 50
Explanation of terms and abbreviations ..................................................... 51
Index .......................................................................................................... 52

VEU-F-60/1-x-C… en(us) Page 4 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Preface

Preface
This operating manual was made to the best of our knowledge. Nevertheless
and despite the greatest care, it cannot be excluded that mistakes could have
crept in. Therefore please understand that in the absence of any provisions
to the contrary hereinafter our warranty and liability – for any legal reasons
whatsoever – are excluded in respect of the information in these operating
instructions. In particular, we shall not be liable for lost profit or other financial
loss. This exclusion of liability does not apply in cases of intent and gross
negligence. Moreover, it does not apply to defects which have been
deceitfully concealed or whose absence has been guaranteed, nor in cases
of culpable harm to life, physical injury and damage to health. If we
negligently breach any material contractual obligation, our liability shall be
limited to foreseeable damage. Claims due to Product Liability shall remain
unaffected.

Technical Support
If you have any questions, suggestions, or encounter any problems of a
technical nature, please don't hesitate to contact us. When contacting us,
please always include the model/type designation and article no. of the
product:
Fax: +49 6897 509 9046
E-mail: filtersystems@hydac.com

Modifications to the Product


We would like to point out that changes to the product (e.g. purchasing
options, etc.) may result in the information in the operating instructions no
longer being completely accurate or sufficient.
When making modifications or performing repair work to components
affecting the safety of the product, the product may not be put back into
operation until it has been examined and released by a HYDAC
representative.
Please notify us immediately of any modifications made to the product
whether by you or a third party.

Warranty
For the warranty provided by us, please refer to the terms of delivery of
HYDAC FILTER SYSTEMS GMBH.
You will find these under www.hydac.com -> Legal information.

VEU-F-60/1-x-C… en(us) Page 5 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Safety Information

Using the documentation


Note that the method described for locating specific information
does not release you from your responsibility of carefully reading
these instructions prior to starting the unit up for the first time and
at regular intervals in the future.

WHAT do you want to know?


I determine which topic I am looking for.

Where can I find the information I’m looking for?


The document has a table of contents at the beginning. I select the chapter
I'm looking for and the corresponding page number.

Chapter description
tel
Produkt / Kapi

Page number
HYDAC Filtertechnik GmbH
BeWa 123456a de
de Seite x
200x-xx-xx
Edition date

Documentation No. Document language


with Index /
File name

The documentation number with its index enables you to order another copy
of the operating and maintenance instructions. The index is incremented
every time the manual is revised or changed.

VEU-F-60/1-x-C… en(us) Page 6 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Safety Information

Safety Information
The unit was built according to the statutory provisions valid at the time of
delivery and satisfies current safety requirements.
Any residual hazards are indicated by safety information and instructions and
are described in the operating instructions.
Observe all safety and warning instructions attached to the unit. They must
always be complete and legible.
Do not operate the unit unless all the safety devices are present.
Secure the hazardous areas which may arise between the unit and other
equipment.
Maintain the unit inspection intervals prescribed by law.
Document the results in an inspection certificate and keep it until the next
inspection.

Signal words and their meaning in the general safety information


In these instructions you will find the following signal words:

DANGER
DANGER – The signal word indicates a hazardous situation with a high level
of risk, which, if not avoided, will result lethal or serious injury.

WARNING
WARNING – The signal word indicates a hazardous situation with a medium
level of risk, which, if not avoided, can result lethal or serious injury.

CAUTION
CAUTION – The signal word indicates a hazardous situation with a low level
of risk, which, if not avoided, can result in minor or moderate injury.

NOTICE
NOTICE – The signal word indicates a hazardous situation with a high level
of risk, which, if not avoided, will result in damage to property.

VEU-F-60/1-x-C… en(us) Page 7 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Safety Information

Structure of the general safety information


All warning instructions in this manual are highlighted with pictograms and
signal words. The pictogram and the signal word indicate the severity of the
danger.
Warning instructions listed before an activity are laid out as follows:

SIGNAL WORD
Type and source of danger
HAZARD SYMBOL
Consequence of the danger

► Measures to avert danger

Hazard symbols
These symbols are listed for all safety information and instructions in these
operating instructions which indicate particular hazards to persons, property
or the environment.
Observe these instructions and act with particular caution in such cases.
Pass all safety information and instructions on to other users.

General hazard

Danger due to electrical voltage / current

Exposed electrical components


Danger of electrical shock

Danger due to operating pressure

VEU-F-60/1-x-C… en(us) Page 8 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Safety Information

Risk of burns due to hot surfaces

Danger from flammable materials

Lashing point; lift the unit using this point

Lashing point; lifting prohibited

Observe regulatory information


Observe the following regulatory information and guidelines:
• Legal and local regulations for accident prevention
• Legal and local regulations for environmental protection
• Country-specific regulations, organization-specific regulations

VEU-F-60/1-x-C… en(us) Page 9 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Safety Information

Proper/designated use
Claims for defects or liability, regardless of the legal foundation, do not apply
with incorrect or improper installation, commissioning, usage, handling,
storage, maintenance, repair, use of unsuitable components or other
circumstances for which HYDAC is not responsible.
HYDAC is not responsible for the installation, integration, selection of
interfaces to / into your system nor for the use or functionality of your system.
Use the unit only for the application described in the following.
The VEU-F is a stationary filtration unit used for filtering hydraulic or
lubricating oils in bypass flow.
Proper or designated use of the product extends to the following:
• Observing all instructions contained in the instruction manual.
• Performing inspection and maintenance work.

Depending on the version (see model code), you may use the VEU-F only in
connection with the following media:

WARNING
Fire hazard

Danger of bodily injury

► With the unit, you may filter/pump only


media/fluids with a flash point ≥ 56°C/133°F

NOTICE

Impermissible operating media

The filtration unit will be destroyed.

► The unit is only to be used with mineral oils or mineral oil-based


raffinates.
► Do not filter any caustic or explosive media.

Improper Use or Use Deviating from Intended Use

DANGER

VEU-F-60/1-x-C… en(us) Page 10 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Safety Information

Danger due to unanticipated use of the unit

Bodily injury and damage to property will result


when operated improperly.

► Never operate the unit in potentially explosive


atmospheres.
► The unit is only to be used with permissible
media.

Any use extending beyond this or deviating therefrom shall not be considered
intended use. HYDAC Filter Systems GmbH will assume no liability for any
damage resulting from such use. The user alone, shall assume any and all
associated risk.

Improper use or use deviating from intended may result in hazards and/or will
damage the unit. Examples of improper use:
• Operation in potentially explosive atmospheres.
• Operation with a non-approved medium.
• Operation under non-approved operational conditions.
• Operation when the safety devices are defective.
• Modifications to the power unit made by the user or purchaser.
• Inadequate monitoring of parts that are subject to wear and tear.
• Improperly performed repair work.

VEU-F-60/1-x-C… en(us) Page 11 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Safety Information

Qualifications of personnel / target group


Persons who work on the power unit must be aware of the associated
hazards when using the power unit.
Auxiliary and specialist personnel must have read and understood the
operating instructions, in particular the safety information and instructions,
and applicable regulations before beginning work.
The operating instructions and applicable regulations are to kept so they are
accessible for operating and specialist personnel.
These operating instructions are intended for:
Auxiliary personnel: such persons have been instructed about the unit and
informed about potential hazards that can result from improper use.
Specialist personnel: such persons with corresponding specialist training
and several years' work experience. They are able to assess and perform the
work assigned to them, they are also able to recognize potential hazards.

VEU-F-60/1-x-C… en(us) Page 12 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Safety Information

Activity Person Knowledge


Transport / storage Forwarding Proof of knowledge of cargo
agent securing instructions
Specialist Safe handling/operation of
personnel hoisting and lifting equipment
Hydraulic / electrical Specialist Safe handling/use of tools
installation, personnel Fitting and connection of
First commissioning, hydraulic tubes and
connections
Operation/settings
Fitting and connection of
Maintenance,
electrical lines, electrical
Troubleshooting, machinery, sockets, etc.
Repair, Checking the phase sequence
Decommissioning, Product-specific knowledge
Disassembly
Operation, Auxiliary Product-specific knowledge
personnel
Operations control Knowledge about how to
handle operating media
Disposal Specialist Proper and environmentally
personnel friendly disposal of materials
and substances
Decontamination of
contaminants
Knowledge about reuse

VEU-F-60/1-x-C… en(us) Page 13 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Transporting the unit

Wear suitable clothing


Loosely worn clothing increases the danger of getting caught or wound up in
rotating parts and the danger of getting snagged on projecting parts. You can
be severely injured or killed.
• Wear close-fitting clothing.
• Do not wear any rings, chains or any other jewelry.
• Wear work safety shoes.

Stoppage in an emergency (EMERGENCY STOP)


In case of emergency, switch off the power unit at the main switch.

Transporting the unit


Transport VEU-F by truck/train.
Only transport the unit in standing position.

VEU-F-60/1-x-C… en(us) Page 14 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Transporting the unit

Transporting with the crane.


For transporting with a crane or forklift truck, use ropes or chains with
suitable lifting gear and tighten them to the permitted attachment points.

VEU-F-60/1-x-C… en(us) Page 15 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Storing the unit

Storing the unit


Empty the unit completely and remove all the filter elements prior to storage.
All the conditions required for storage are listed in the "Technical Data"
section on page 48.
Only store the unit in standing position.

VEU-F-60/1-x-C… en(us) Page 16 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Decoding the model code label

Decoding the model code label


Details for identifying the power unit can be found on the type labels on the
unit and the components.

Item -> Description


(1) -> Name plate for power unit
(2) -> Name plate of electric motor
(3) -> Model code; for details, see page 50
(4) -> Year of production
Power -> Power consumption, electrical

VEU-F-60/1-x-C… en(us) Page 17 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Decoding the model code label

Item -> Description


Voltage / Grid -> Voltage supply / power supply
Frequency -> Voltage frequency
Current -> Current consumption
Pressure max. -> Maximum operating pressure
Pressure IN -> Permissible pressure at port IN
Pressure OUT -> Permissible pressure at port OUT
Weight -> Weight when empty
Flow Rate -> Flow
Temp. oil -> Permitted fluid temperature range
Temp. amb. -> Permitted ambient temperature range
Visc. Range -> Permissible viscosity range

VEU-F-60/1-x-C… en(us) Page 18 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Checking the scope of delivery

Checking the scope of delivery


Check the unit for any damage upon arrival.
The following items are supplied:
Item Qty Description
1 1 VEU-F-60/1-x-C …
Technical documentation, consisting of:
- Operation and maintenance instructions (this document)
- Wiring diagram
- 1
- Documents on the components
(e.g. RFCS side cooler)
- CE declaration of conformity

VEU-F-60/1-x-C… en(us) Page 19 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Characteristics of the unit

Characteristics of the unit


The service-friendly VarnishElimination Units VEU are used to condition
mineral oils. They are particularly effective at removing oil aging products
(varnish) from mineral oils. Varnish takes the form of oil-insoluble oil
degradation products which settle in the tank, the valves or the bearings.
These can be filterable gels or solid paint-type deposits.
The VEU-F series of units is used in bypass flow. The varnish is removed by
reducing the oil solubility of varnish and then filtering it out.
Uses for the VEU-F include:
• Removal of solid or gel-like oil degradation products in lubrication and
hydraulic systems, e.g. in:
o Presses
o Machine tools
o Systems with H1 food-grade oils
o Turbine lubrication

Using the VEU-F can offer you the following advantages:


• Increased operating reliability of the system as a result of fewer
deposits in hydraulic valves
• Increase in the oil service life

VEU-F-60/1-x-C… en(us) Page 20 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
VEU-F components

VEU-F components
Depending on which version of the unit you choose, it will come with
different/optional components. Below, you can see the optional components
that come with the VEU-F-60/1-M-C….

VEU-F-60/1-x-C… en(us) Page 21 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
VEU-F components

Item Description
1 Oil inlet (INLET)
2 Oil outlet (OUTLET)
3 Filter housing air vent (VENT)
4 Filtration unit drain (DRAIN)
5 Drip tray drain
6 Clogging indicator, electrical
7 Electrical control unit; for details, see page 32
7.1 Unit main switch
10 Motor pump assembly
11 Filter housing
11.1 Clogging indicator, visual
12 Plate heat exchanger
13 Side cooler RFCS
13.1 On/Off switch on unit cooling compressor
13.2 Temperature controller display on unit cooling compressor
14 Suction strainer
17 Roller, rigid (optional – mobile version only)
18 Roller, with steering (optional – mobile version only)
19 Sliding grip

VEU-F-60/1-x-C… en(us) Page 22 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
VEU-F components

Dimensions
Each version of the unit has different dimensions.

Figure: VEU-F mobile version.


All dimensions in mm.

VEU-F-60/1-x-C… en(us) Page 23 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
VEU-F components

Figure: VEU-F stationary version.


All dimensions in mm.

VEU-F-60/1-x-C… en(us) Page 24 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
VEU-F components

Hydraulic diagram

INLET

IN
COOLANT

OUT
Cooler COOLANT

VENT

DRAIN
DPI

OUTLET

VEU-F-60/1-x-C… en(us) Page 25 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
VEU-F components

Item Description
INLET Inlet oil
OUTLET Outlet oil
VENT Filter housing air vent
DRAIN Filtration unit drain
DPI Clogging indicator, electrical
Cooler Electrical control unit; for details, see page xx
IN Unit main switch
OUT Motor pump assembly

VEU-F-60/1-x-C… en(us) Page 26 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Setting up / Installing VEU-F

Setting up / Installing VEU-F


Observe the following points when setting up the unit:
1. The unit must be set up on an even, level surface.
2. Make sure that there is sufficient space above the filter housing to
replace the filter elements.
3. Make sure that there is sufficient space above the side cooler. For more
details, see the Installation and Maintenance Instructions for the side
cooler, which are included in the Technical Documentation for the unit.
4. Observe the maximum permissible ambient temperature and constant
supply of cooling air for units which have a motor-pump assembly to
avoid overheating.
5. In the case of installation below the fluid level, install shut-off valves in
the feed and return lines.
6. Connect the suction and pressure ports as described on pages 28 to
29.
7. Connect all the unit's electrical connections. See page 30 for details
8. When starting up for the first time, follow the steps below:
- Fill the side cooler with a water/glycol mixture; for more details, see
page 29.
- Insert the filter elements in the filter housing. See page 35 for details.

VEU-F-60/1-x-C… en(us) Page 27 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Setting up / Installing VEU-F

Notes on pipes and hoses


Make sure that no vibrations or stress/loading from other machinery and
equipment are carried over to filter housing. If necessary, use expansion
joints.
The pressure loss in a hydraulic line depends upon:
• Flow rate
• Kinematic viscosity
• Pipe dimensions
• Fluid density
The pressure loss can be estimated for hydraulic oils as follows:

Δp ≈ 6.8 * L / d4 * Q * V * D
Δp = Pressure differential in [bar]
L = Pipe length [m]
d = Internal pipe diameter [mm]
Q = Flow rate [l/min]
V = Kinematic viscosity [mm²/s]
D = Density [kg/dm³] Mineral oil based hydraulic fluid has a
density of ≈ 0.9 kg/dm³.

This applies to straight pipelines and hydraulic oils. Additional threaded


connections and pipe bends increase the pressure differential. Additional
threaded connections and pipe bends increase the pressure differential.
Keep the height difference between the pump and the oil level in the tank as
low as possible.
Constrictions in the connections and lines should be avoided. This could
compromise suction output and cause cavitation.
Take note that the nominal size of the connected hoses/piping must be at
least as large as the inlet port sizes.
Make sure that no vibrations or stress/loading from other machinery and
equipment are carried over to filtration unit. Make sure that no vibrations or
stress/loading from other machinery and equipment are carried over to
filtration unit. Use hoses or expansion joints if necessary.

VEU-F-60/1-x-C… en(us) Page 28 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Setting up / Installing VEU-F

Connecting the suction port - INLET


For the suction port connection, use a flexible hose that is resistant to
negative pressure. Avoid constrictions in the connecting lines, as they
compromise suction performance and increase the risk of cavitation.
In case of coarse contamination (> 100 µm) such as weld splatter, an
appropriate suction strainer must be installed in the suction line in order to
protect the pump.
If a unit without a motor-pump assembly is used, it is important to ensure that
no pressure pulsation is transmitted to the filter housing.

NOTICE

Overpressure at the suction port connection

The unit will be damaged

► The maximum pressure on the suction port IN must not be more than -
0.4 to 2.0 bar.

Connecting the pressure port - OUTLET


Make sure that the nominal width of the pressure line corresponds to the
connector thread of the filter housing.
Install the return line below the oil level to prevent air from entering the fluid
in the tank.
If the clogging indicator pressure displayed for the a clean
filter element is > 1 bar, use a differential pressure clogging
indicator.

Preparing the RFCS side cooler


Remove the metal air filter from the side cooler and fill the tank with the
water/glycol coolant (min. 20% … max. 40%) up to the "Max." mark using the
tank filling nozzles on the side cooler.
Insert the metal air filter in the side cooler and check that the side cooler is
switched on at the main switch (13.1).
For more details, see the Installation and Maintenance Instructions for the
side cooler, which are included in the Technical Documentation for the unit.

VEU-F-60/1-x-C… en(us) Page 29 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Setting up / Installing VEU-F

Electrical connection of the unit


Check the voltage and frequency specifications on the motor name plate
against the existing network specifications.
Plug the male connector into a suitable, grounded power outlet.

Checking direction of rotation


Check the direction of rotation of the motor by switching it on briefly (jog
mode).
The unit requires a clockwise rotating field at the connecting socket.

NOTICE

Incorrect phase sequence / rotation direction of the motor

The pumps will be destroyed.

► In jog mode, check the direction of rotation of the motors.


► A rotation direction arrow on the fan cover of the motor identifies the
correct direction of rotation.

If rotation is in the opposite direction, change the phases in the terminal box
or rotate the phases in the connection plug using the phase inverter in the
connection plug.

VEU-F-60/1-x-C… en(us) Page 30 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Starting up the unit

Starting up the unit

WARNING
Hydraulic system is under pressure

Danger of bodily injury

6 bar maximum ► Note the maximum operating pressure


87 psi max. ► The hydraulic system must be depressurized
before performing any work on the hydraulic
system.
► Vent the filter housing

Before commissioning, open the filter housing and check that the filter
elements are firmly in place and that the locking cap is installed, or insert the
filter elements if necessary. You can find details about changing the filter
elements on page 35.
Put the unit into operation only after all preparations for commissioning are
complete.

VEU-F-60/1-x-C… en(us) Page 31 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Starting up the unit

Switching on/operating the unit


Use the controls in the control cabinet to operate the unit.

1. Switch on the unit at the main switch.


2. Press the "Enable MPG" button.
3. Press the "Enable cooler" button.
4. The unit is now in operation.

"Error" signal lamp lights up


As soon as the unit encounters an error, the signal lamp lights up and the
unit shuts down all its components.
To clear the error, switch the unit off at the main switch, resolve the error and
then switch the unit back on at the main switch.

"Filter contaminated" signal lamp lights up


As soon as the "Filter contaminated" signal lamp lights up on the unit, all the
unit's components are shut down.
Change the filter elements as described in the "Changing filter element(e)"
section on page 35.
To clear the error, switch the unit off at the main switch, resolve the error and
then switch the unit back on at the main switch.

VEU-F-60/1-x-C… en(us) Page 32 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Starting up the unit

"Tray overflow" signal lamp lights up


As soon as the "Tray overflow" signal lamp lights up on the unit, all the unit's
components are shut down.
Empty the tray and fix the leakage.
To clear the error, switch the unit off at the main switch, resolve the error and
then switch the unit back on at the main switch.

Checking the temperature setting on the side cooler


Once the unit is switched on, check the set temperature on the display of the
side cooler. The target range is between 0 and 10°C.
If necessary, correct the temperature setting. For more details on this, see
the Installation and Maintenance Instructions for the side cooler, which are
included in the Technical Documentation for the unit.

Switching off the unit


1. Press the "Cooler off" button.
2. Press the "MPG off" button.
3. Switch off the unit at the main switch.

VEU-F-60/1-x-C… en(us) Page 33 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Performing maintenance

Performing maintenance

WARNING
Hydraulic systems are under pressure

Danger of bodily injury

► The hydraulic system must be depressurized


before performing any work on the hydraulic
system.

The unit is equipped with a differential pressure manometer. This shows you
the differential pressure at the filter element.

Maintenance of the side cooler


For details on maintenance and the maintenance cycles, see the Installation
and Maintenance Instructions for the side cooler, which are included in the
Technical Documentation for the unit.

VEU-F-60/1-x-C… en(us) Page 34 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Performing maintenance

Changing filter element(e)


To change the filter elements, proceed as follows:
1. Switch off the motor-pump assembly and
make sure that it cannot be inadvertently
switched back on.

2. Close all shut-off valves at the inlet and


outlet.
3. Unscrew the air bleed screw (x) completely
using a 10 mm Allen wrench.

4. (1) Have a suitable container on hand to


catch the fluid.
(2) Open the drain fitting, and collect the
escaping fluid in the tray.
Once the housing has been completely
drained, close the drain fitting.

3. Screw in the air bleed screw (x) by hand in a


clockwise direction, and tighten it using a
10 mm Allen wrench.

VEU-F-60/1-x-C… en(us) Page 35 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Performing maintenance

4. Release the housing tensioning clamps (1),


and remove them.
Lift off the cover (a).
Remove the intermediate piece (b).

5. Turn the element locking cap on the top filter


element by 90° in counterclockwise direction
(1) and lift off the locking cap (2).

VEU-F-60/1-x-C… en(us) Page 36 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Performing maintenance

6. Turn all filter elements 90° in a


counterclockwise direction, and remove
them.

7. Dispose of the used filter elements in an


environmentally friendly manner.

8. Clean the inside of the filter housing of


coarse dirt.
Check the O-rings on the filter housing for
damage. If necessary, replace them.

VEU-F-60/1-x-C… en(us) Page 37 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Performing maintenance

9. Insert the filter element into the bayonet


fitting (1), and lock it in place by turning each
individual filter element 90° in the clockwise
direction (2).

10. Place the element locking cap on the upper


filter element (1).
Turn the locking cap 90° in the clockwise
direction to lock it in place.

No element locking cap = no


filtration.

VEU-F-60/1-x-C… en(us) Page 38 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Performing maintenance

11. Put the intermediate piece (b) on the lower


section (c).
Mount the lower housing tensioning clamp
(1) and tighten it with a torque of 20 Nm.
Secure it using the lock nut.
Put the cover (a) on the intermediate piece
(b).
Mount the upper housing tensioning clamp
(2) and tighten it with a torque of 20 Nm.
Secure using the lock nut.

We recommend applying lubricant


containing a slip additive to the threads of
the housing tensioning clamp each time
filters are changed so that it remains easy to
remove.
Lubricant containing a slip additive – HYDAC
p/no. 3066287
12. Open all shut-off valves at the inlet and
outlet.
If a pump is present, switch it on.
13. Fill the filter housing slowly.
Slightly undo the air bleed screw (x). The air
in the filter housing can escape via the slot
on the air bleed screw.
Bleed the filter housing with the air bleed
screw (x) until operating fluid comes out.
Tighten the air bleed screw.
14. The filter element change is now complete.
The unit is ready for operation.

VEU-F-60/1-x-C… en(us) Page 39 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Performing maintenance

Clean the suction strainer

NOTICE

Suction strainer missing / operating without a suction strainer

The unit will be destroyed

► Never operate the unit without a suction strainer.


► Clean the suction screen regularly.

A suction strainer is fitted into a piece of pipe of the suction line to protect the
pump from coarse contamination.
Clean the suction strainer at regular intervals, e.g. by flushing it with solvent
or blow-flushing it with compressed air.
Test and clean the suction strainer immediately in the event of insufficient
suction or delivery action.

VEU-F-60/1-x-C… en(us) Page 40 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Performing maintenance

To replace the suction strainer, proceed as follows:

1. Switch the motor-pump group off.


2.
Unscrew the screw plugs (1) with a fork wrench ( = 30 mm) by
turning it counterclockwise.
3. Remove the strainer insert (3) and clean it.
4. Check strainer insert (3) and the seal ring (2) on the screw plug for
damage and replace if necessary.
5. Insert the cleaned / new strainer insert (3).
6. Turn the screw plug (1) with the seal ring (2) clockwise manually and
tighten with the fork wrench ( = 30 mm).
7. Check the suction strainer fitting for leaks after commissioning.
8. Replacing/exchanging the suction strainer is now complete.

VEU-F-60/1-x-C… en(us) Page 41 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Performing maintenance

Cleaning / Flushing the plate heat exchanger on the cooling water side
Clean the heat exchanger contaminated on the cooling water side by
flushing. This loosens and removes the majority of soft deposits clogging the
inside.
The solution used for flushing is a weak acid with concentration less than 5%,
for example citric acid.
If acidity is too high, the copper and stainless steel, which is inside the plate
heat exchanger, might be etched or corroded. Before restarting the system,
flush the plate heat exchanger with large amounts of fresh water to remove
any remaining acid solution.

Exchanging / Replacing plate heat exchanger


If the heat exchanger is blocked/clogged on the oil side or if there is no flow,
replace the heat exchanger.

VEU-F-60/1-x-C… en(us) Page 42 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Errors and eliminating errors

Errors and eliminating errors


The following errors can occur during operation of the unit.
Error Cause Rectifying errors
The pump will not Check the mains power is Insert the power plug into
start plugged in or that the a suitable power outlet
electric motor is with the matching voltage
connected electrically. for the unit.
Check the voltage details
on the name plate with
the voltage in your mains.
The main switch is not Switch on the unit at the
switched on. main switch.
The pump is blocked. Contact the HYDAC
Service Department.
"Filter The filter elements are Replace the filter
contaminated" used / blocked. elements.
signal lamp lights To reset the error, switch
up off the unit at the main
switch.
The OUTLET connection Check the connection /
is closed or blocked. the run of the pressure
feed line.
To reset the error, switch
off the unit at the main
switch.
The pressure relief valve Send the motor-pump
in the motor-pump assembly to the
assembly does not manufacturer for repair.
respond or is To reset the error, switch
contaminated. off the unit at the main
switch.

VEU-F-60/1-x-C… en(us) Page 43 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Taking the unit out of operation

Taking the unit out of operation


To take the unit out of operation, proceed as follows:
1. Switch off the unit at the main switch.
2. Close all shut-off valves on the unit.
3. Drain the unit completely.
4. Remove all the filter elements.
5. Clean the inside of the housing.
6. Remove all the hydraulic and electrical connections to the unit.

Disposing of the unit


Dispose of the packaging material in an environmentally friendly manner.
After dismantling the unit and separating the various materials, dispose of the
unit in an environmentally-friendly manner.

VEU-F-60/1-x-C… en(us) Page 44 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Finding spare parts

Finding spare parts


Use only original spare parts. Make sure to always indicate the exact unit
designation (see nameplate) and the serial number when ordering spare
parts.

VEU-F-60/1-x-C… en(us) Page 45 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Finding spare parts

VEU-F-60/1-x-C… en(us) Page 46 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Finding spare parts

Item Description p/no. Qty


100 Lower section 3030869 1
140 Dynamic pressure gauge 0039173 1
152 Intermediate piece 3030463 1
153 Cover, tall 3030461 1
151 Filter element locking cap NBR 0349235 1
151 Filter element locking cap FPM * 1
154 Tensioning clamp for 6 bar / 87 psi 6005235 2
housing
155 O-ring for filter housing NBR 6005449 2
155 O-ring for filter housing FKM 6012630 2
156 Air bleed plug [Air bleed] NBR 0403302 1
156 Air bleed plug [Air bleed] FPM 0403302 1
- Filter element, 2 µm N15DM002 1251590 4
210 Motor pump assembly * -
322 Rigid caster 6192902 2
323 Guide roll 6192910 2
410 Plate heat exchanger 3383913 1
420 Side cooler * 1
503 Hose 680 mm 6004260 1
504 Hose 400 mm 6013426 1
522 Hose 680 mm 6004260 1
548 Suction strainer, 6019635 1
assembly
- Suction strainer insert for 548 6071343 1
600 Clogging indicator / * -
differential pressure
gauge
703 Hose 495 mm 6082465 1
704 Hose 1080 mm 6082466 1
*) available on request

VEU-F-60/1-x-C… en(us) Page 47 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Technical Data

Technical Data
Technical Data VEU-F 60/1
Number of filter elements 4
N15DMxxx
Dirt tray / 2000 g
Varnish tray

Permissible ∆p on filter element 2 bar

Weight of the filter elements 12 kg


Filter housing material 1.4301
Filter housing filling volume 78 l (operating medium)
Compressor cooler filling volume 40 l (coolant)
Weight when empty ≈ 325 kg
(mobile version with rollers ≈ 335 kg)
Connection oil INLET M36x2 (28L), in accordance with
ISO8434-1
Connection oil OUTLET M30x2 (22L), in accordance with
ISO8434-1
Draining DRAIN G 1, according to ISO228-1
Air bleed BLEED G1/2, according to ISO228-1
Drip tray drain G1/2, according to ISO228-1
Operating pressure, maximum 6 bar /87 psi
Permissible pressure at pressure 0 … 3 bar
port oil OUTLET
Permissible pressure at oil INLET -0.4 – 2 bar
suction port
Sealing material NBR (optional: FPM)
Permissible viscosity range 15 to 300 mm²/s
Permitted fluid temperature range 10 … 80 °C /
50 … 176 °F
Permitted ambient temperature -10 … 40 °C /
range 14 … 104 °F
Storage temperature 5 … 30°C / 41 … 86°F
Humidity Up to 80% relative humidity, non-

VEU-F-60/1-x-C… en(us) Page 48 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Technical Data

condensing
Air Clean, salt-free air, not near oxidizing
substances (rust film).
Storage duration Indefinite.
Before the unit is started up again after
being stored for more than two years,
all seals must be replaced.

VEU-F-60/1-x-C… en(us) Page 49 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Attachment

Attachment

Model code
VEU - F - 60/1 - S - C - G - M - Z - C17 - FA2
Basic Type
VEU = VarnishElimination Unit
Function
F = Filtration
Installation size
60/1 = Filter housing 60 liter /
Nominal flow rate 1 l/min
Version
S = Stationary
M = Mobile
Cooler / Heat exchanger
C = Compressor coolers
Pump
G = Gear pump
Voltage
B = P = 480 V, 3 Ph
C = P = 380 V, 3 Ph
G = P = 440 V, 3 Ph
N = P = 400 V, 3 Ph
O = P = 460 V, 3 Ph
P = P = 575 V, 3 Ph
R = 415V, 3 Ph
S = P = 500 V, 3 Ph
X = Other voltages on request
Z = Without electro motor
filter element
Z = without filter element
Clogging indicator
C = Differential pressure indicator, electrical
Supplementary details
S3D5 = Suction/Return hose with lance, length = 3 m / 5 m (only for mobile variant)
SKDK = Suction/Return hose with threaded connection, length = 2.5 m / 5 m (only for
mobile variant)
PKZ = On-off switch with motor protection switch
FA1 = With on-off switch and cut-out when filter clogged incl. option PKZ
(clogging indicator C or D3)
FA2 = With on-off switch and cut-out when filter clogged incl. option PKZ
(clogging indicator C or D3) without neutral wire
®
V = Seal material FKM (FPM, Viton )

VEU-F-60/1-x-C… en(us) Page 50 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Attachment

Explanation of terms and abbreviations


An explanation of terms and abbreviations follows below:
AC Alternating current
DIN Deutsche Industrie Norm [German Industry
Standard]
DN Nominal Diameter
EC European Community
EU European Union
VEU-F VarnishElimination Unit - Filtration
NBR Nitrile rubber
FPM Fluoroelastomer rubber
IN Inlet
INLET Inlet
ISO International Standards Organization
NAS Classification of the solid particle contamination.
OUT Outlet
OUTLET Outlet

VEU-F-60/1-x-C… en(us) Page 51 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Attachment

Index

A H
accident prevention 9
acidity 42 Hazard symbol 8
ambient temperature 18, 27, 48 Hydraulic diagram 25
Auxiliary personnel 12, 13

I
B
Imprint 2
BLEED 48 IN 18, 26, 29, 51
In case of emergency 14
Inlet 26, 51
INLET 22, 26, 29, 48, 51
C installation 10, 13, 27
Internal pipe diameter 28
care 2, 5 ISO 51
Cause 43
Clogging indicator 22, 26, 47, 50
connecting 29, 30 L
Connection 48
Content 3
Lashing point 9

D M
Density 28
Description 17, 18, 19, 22, 26, 47 Maintenance 1, 13, 27, 29, 33, 34
Differential pressure 50 Measures 8
differential pressure gauge 47 Mineral oil 28
Differential pressure indicator 50 Model code 17, 50
Dimensions 23 Motor pump assembly 22, 26, 47
DIN 51
Disposal 13
Documentation Representative 2 N
DRAIN 22, 26, 48
NAS 51

E
O
Error 32, 43
Off switch 22
operating 5, 6, 7, 8, 10, 12, 13, 18, 20, 31, 32, 39,
F 40, 48
Operation 11, 13, 19
filling 29, 48 Operations control 13
Filter 11, 22, 26, 32, 43, 47, 48, 50 OUT 18, 26, 51
Filter element 47 Outlet 26, 51
Filter housing 22, 26, 48, 50 OUTLET 22, 26, 29, 43, 48, 51
filtration 10, 28, 38
Filtration 1, 22, 26, 50, 51
Flow rate 28 P
Forwarding agent 13
Power consumption 17
Pressure differential 28
G Publisher 2
Pump 50
gear 15
Gear pump 50

VEU-F-60/1-x-C… en(us) Page 52 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
Attachment

R T
Rigid caster 47 Temperature 22
Transport 13, 14
transporting 15
S Troubleshooting 13

select 6
Service 43 V
setting 27, 33
Signal word 7, 8 Varnish 20, 48
signal words 7, 8 VENT 22, 26
Specialist personnel 12, 13
Storage temperature 48
W
Weight 18, 48

VEU-F-60/1-x-C… en(us) Page 53 / 56


BEWA VEU-F-601-x-C 4104528a en-us 2018-06-18.docx 2018-06-18
HYDAC FILTER SYSTEMS GMBH
Industriegebiet Postfach 1251
66280 Sulzbach/Saar 66273 Sulzbach/Saar
Germany Germany

Tel: +49 6897 509 01 Board no.


Fax: +49 6897 509 9046 Technology
Fax: +49 6897 509 577 Sales

Internet: www.hydac.com
E-mail: filtersystems@hydac.com

You might also like