Issue Date: 15-Nov-2007 Rev.

Date: 15-Nov-2007 Revision: 1


Author: Devon A. Perry Page 1 of 7 Content ID: 3953183

UniConn Operation Manual Addendum


Subject: Differential Pressure from Phoenix Interface Card/UniConn
Firmware: 1.200r4; StarView Version 3.000r1

Introduction

This document should be used in conjunction with UniConn Operation Manual Rev D (InTouch
Content Number 3953183), to supplement Section 7.2 – Phoenix Interface Card. This document will
explain how to view and set parameters for Differential Pressure – with emphasis on changes

Schlumberger Private
and addition to both the UniConn’s and StarView’s (formerly WellView) menu structure.

Hardware Requirement

• UniConn
• PIC (Phoenix interface card)

Firmware / Software Requirement

• UniConn firmware Version 1.200r4


• PIC firmware version - Any
• StarView (formerly Wellview) version 3.000r1

New Features/Control Functionality

• Added Differential Pressure reading and Alarming


• Added logging of PIC faults.

DIFFERENTIAL PRESSURE

Differential Pressure measurements have been added to the Phoenix Interface Card (PIC) menu
in the MOTOR/VSD section of the UniConn.

• For XT, Select Type 1, Select Standard and CTS Double Pressure tools, Differential
pressure is calculated using [Discharge Pressure – Intake Pressure].
© Copyright Statement This document remains the property of Schlumberger and is Confidential and Trade Secret.
Do not disclose, use, or reproduce without written approval from Schlumberger
Page 2 of 7

• For the Select Advance tool, Differential Pressure is calculated using [Discharge Pressure
– Remote 2 Pressure].

• Differential Pressure measurements are not available for Select Lite, CTS single pressure
and Ultra Lite tools.

• A set of parameters are included for low differential pressure alarming (DIFFP_LO)

• A set of parameters are included for high differential pressure alarming (DIFFP_HI)

To view Differential Pressure measurement in the UniConn, navigate to the MOTOR/VSD menu,
“Differential Pressure” is next after “Pump Discharge Pressure”.

Differential Pressure: 34bar


DIFFP_LO DIFFP_HI PREV NEXT

Schlumberger Private
Figure 1.0 – Viewing Differential Pressure in UniConn

In StarView, Differential Pressure (PDif) measurement is located below Discharge Pressure (Pd)
in the PHOENIX DHT area.

© Copyright Statement: This document remains the property of Schlumberger. It is Confidential and Trade Secret
and not to be disclosed, used, or reproduced without written approval from Schlumberger.
Page 3 of 7

Schlumberger Private

Figure 1.1 - Viewing Differential Pressure in StarView

Alarm setpoints for Differential Pressure can be accessed in the UniConn by selecting DIFFP_LO
or DIFFP_HI in the Differential Pressure menu.

© Copyright Statement: This document remains the property of Schlumberger. It is Confidential and Trade Secret
and not to be disclosed, used, or reproduced without written approval from Schlumberger.
Page 4 of 7

Differential Pressure: 34bar


DIFFP_LO DIFFP_HI PREV NEXT

Action Action
Alarm Setpoint Alarm Setpoint
Alarm Trip Time Alarm Trip Time
Restarts Restarts
Restart Delay Restart Delay
Start Bypass Start Bypass

Figure 1.3 – Differential Pressure Alarm Setpoints

Differential Pressure alarm setpoints in StarView

Schlumberger Private

Figure 1.4 - Differential Pressure Alarm Setpoints in StarView

© Copyright Statement: This document remains the property of Schlumberger. It is Confidential and Trade Secret
and not to be disclosed, used, or reproduced without written approval from Schlumberger.
Page 5 of 7

PIC Status/Fault Logging

UniConn now logs PIC Faults. “Tool Ok” will be logged once no faults are present, “Tool Open”,
“Tool Short”, “CL Not Set” will show up in the log once they occur. All other faults will show up
as ‘PIC Fault ##’. ## represents the fault code which is listed below:

PIC Fault Table


Fault Fault Code
CF Dropped 10
PSU Not Booting 11
Tool Stuck 12
Tool Stuck RSR 13
Negative Saturation 14
Short Circuit 15
Other Tool Fault 16
Non Tool Fault 17
Panel Undervolts 18

Schlumberger Private
Panel Over Volts 19
Excessive Leakage 20
Power Latch Failed 21
ADC Failed 22

Table 1.0 – PIC Faults

Examples

11/07 11:33:33.9 Tool Open


2-LINE << >> PREV NEXT

11/07 11:34:12.4 Tool OK


2-LINE << >> PREV NEXT

11/07 11:34:06.0 PIC Fault 11


2-LINE << >> PREV NEXT

© Copyright Statement: This document remains the property of Schlumberger. It is Confidential and Trade Secret
and not to be disclosed, used, or reproduced without written approval from Schlumberger.
Page 6 of 7

Appendix A – Phoenix Interface Card Menus

Note:

• Where there’s no change in menu structure compared to previous firmware revision, only top
level menus are displayed.

• Alarm set-point parameters for every set-point are as can be seen in UniConn Operation
Manual Rev C/D Appendix A.

Pump Intake Press: 294.0bar


PI_LO PI_HI PREV NEXT

Pump Discharge Press: 0.0bar


PD_LO
Pr2_LO PD_HI PREV NEXT

Differential Pressure: -294bar


DIFFP_LO DIFFP_HI PREV NEXT
Action: LOG+STOP
EDIT PREV NEXT

Schlumberger Private
Action: BYPASS Alarm Setpoint: 4500
EDIT PREV NEXT EDIT PREV NEXT

Alarm Setpoint: 0 Alarm Trip Time: 30s


EDIT PREV NEXT EDIT PREV NEXT

Alarm Trip Time: 60s Restarts: 3


EDIT PREV NEXT EDIT PREV NEXT

Restarts: 3 Restart Delay: 30min


EDIT PREV NEXT EDIT PREV NEXT

Restart Delay: 30min Start Bypass: 0.0s


EDIT PREV NEXT EDIT PREV NEXT

Start Bypass: 0.0s


EDIT PREV NEXT

Pump Flow Rate: 0.0m3/d


FLOW_LO FLOW_HI PREV NEXT

Bottom Hole Temperature: 100.0C


BHT PREV NEXT

Motor Winding Temperature: 87.0C


TM PREV NEXT

Discharge Temperature: 87.0C


Td_HI PREV NEXT

Starpoint Voltage: 0.5V


Vs_LO Vs_HI PREV NEXT

Pump/Ax Vibration: 0.025g


VIB PREV NEXT

Vibration Ay: 0.050g


Ay_HI PREV NEXT

© Copyright Statement: This document remains the property of Schlumberger. It is Confidential and Trade Secret
and not to be disclosed, used, or reproduced without written approval from Schlumberger.
Page 7 of 7

Vibration Az: 0.030g


Az_HI PREV NEXT

Vib Ax Remote 1: 0.012g


Ax1_HI PREV NEXT

Vib Ay Remote 1: 0.050g


Ay1_HI PREV NEXT

Vib Az Remote 1: 0.030g


Az1_HI PREV NEXT

Press Remote 2: 125.3psi


Pr2_LO Pr2_HI PREV NEXT

Temp Remote 2: 75.5 C


Tr2_HI PREV NEXT

Vib Ax Remote 2: 0.012g


Ax2_HI PREV NEXT

Vib Ay Remote 2: 0.050g


Ay2_HI PREV NEXT

Vib Az Remote 2: 0.030g


Az2_HI PREV NEXT

Schlumberger Private
DC Current Leakage Passive: 0.005mA
LkP_HI PREV NEXT

DC Current Leakage Active: 0.004mA


DH_CALIB LkA_HI PREV NEXT

PIC Status: Tool Open


PREV NEXT

Tool Type Live: Select Lite


EDIT PREV NEXT

PIC Software Version: 2.00


PREV NEXT

© Copyright Statement: This document remains the property of Schlumberger. It is Confidential and Trade Secret
and not to be disclosed, used, or reproduced without written approval from Schlumberger.