PIC Addendum for Firmware 1.200r4_3953183
PIC Addendum for Firmware 1.200r4_3953183
Introduction
This document should be used in conjunction with UniConn Operation Manual Rev D (InTouch
Content Number 3953183), to supplement Section 7.2 – Phoenix Interface Card. This document will
explain how to view and set parameters for Differential Pressure – with emphasis on changes
Schlumberger Private
and addition to both the UniConn’s and StarView’s (formerly WellView) menu structure.
Hardware Requirement
• UniConn
• PIC (Phoenix interface card)
DIFFERENTIAL PRESSURE
Differential Pressure measurements have been added to the Phoenix Interface Card (PIC) menu
in the MOTOR/VSD section of the UniConn.
• For XT, Select Type 1, Select Standard and CTS Double Pressure tools, Differential
pressure is calculated using [Discharge Pressure – Intake Pressure].
© Copyright Statement This document remains the property of Schlumberger and is Confidential and Trade Secret.
Do not disclose, use, or reproduce without written approval from Schlumberger
Page 2 of 7
• For the Select Advance tool, Differential Pressure is calculated using [Discharge Pressure
– Remote 2 Pressure].
• Differential Pressure measurements are not available for Select Lite, CTS single pressure
and Ultra Lite tools.
• A set of parameters are included for low differential pressure alarming (DIFFP_LO)
• A set of parameters are included for high differential pressure alarming (DIFFP_HI)
To view Differential Pressure measurement in the UniConn, navigate to the MOTOR/VSD menu,
“Differential Pressure” is next after “Pump Discharge Pressure”.
Schlumberger Private
Figure 1.0 – Viewing Differential Pressure in UniConn
In StarView, Differential Pressure (PDif) measurement is located below Discharge Pressure (Pd)
in the PHOENIX DHT area.
© Copyright Statement: This document remains the property of Schlumberger. It is Confidential and Trade Secret
and not to be disclosed, used, or reproduced without written approval from Schlumberger.
Page 3 of 7
Schlumberger Private
Alarm setpoints for Differential Pressure can be accessed in the UniConn by selecting DIFFP_LO
or DIFFP_HI in the Differential Pressure menu.
© Copyright Statement: This document remains the property of Schlumberger. It is Confidential and Trade Secret
and not to be disclosed, used, or reproduced without written approval from Schlumberger.
Page 4 of 7
Action Action
Alarm Setpoint Alarm Setpoint
Alarm Trip Time Alarm Trip Time
Restarts Restarts
Restart Delay Restart Delay
Start Bypass Start Bypass
Schlumberger Private
© Copyright Statement: This document remains the property of Schlumberger. It is Confidential and Trade Secret
and not to be disclosed, used, or reproduced without written approval from Schlumberger.
Page 5 of 7
UniConn now logs PIC Faults. “Tool Ok” will be logged once no faults are present, “Tool Open”,
“Tool Short”, “CL Not Set” will show up in the log once they occur. All other faults will show up
as ‘PIC Fault ##’. ## represents the fault code which is listed below:
Schlumberger Private
Panel Over Volts 19
Excessive Leakage 20
Power Latch Failed 21
ADC Failed 22
Examples
© Copyright Statement: This document remains the property of Schlumberger. It is Confidential and Trade Secret
and not to be disclosed, used, or reproduced without written approval from Schlumberger.
Page 6 of 7
Note:
• Where there’s no change in menu structure compared to previous firmware revision, only top
level menus are displayed.
• Alarm set-point parameters for every set-point are as can be seen in UniConn Operation
Manual Rev C/D Appendix A.
Schlumberger Private
Action: BYPASS Alarm Setpoint: 4500
EDIT PREV NEXT EDIT PREV NEXT
© Copyright Statement: This document remains the property of Schlumberger. It is Confidential and Trade Secret
and not to be disclosed, used, or reproduced without written approval from Schlumberger.
Page 7 of 7
Schlumberger Private
DC Current Leakage Passive: 0.005mA
LkP_HI PREV NEXT
© Copyright Statement: This document remains the property of Schlumberger. It is Confidential and Trade Secret