Fan coil units shall include the following:
Solar Cells
Solar Arrays
Centrifugal fan, direct drive.
Inverters
Change Controller
Motor, three speed permanent split capacitor type with oil cups and overload protection.
Water coil, copper tubes/aluminium fins, three rows minimum. Use two coils or double circuit type for 4 pipe system. Include
Wind Turbines drain and vent connections integral with coil.
T bi
Turbines
Hybrid Systems Include primary and auxiliary insulated drain pans. Drain pans shall be coated on the inside to prevent leakage and corrosion.
Grid Systems Unit casing shall be insulated with 15mm heavy density glass fibre, 18 gauge steel bonded and baked enamel finish (where
Water Pumping finished cabinet is used).
Using Wind Energy
Enviromental Aspects Units shall be UL listed.
Buyer's Guide
Unit sound pressure levels shall not exceed an NC 35 curve in all octave bands at medium speed.
Save Energy Thermostats shall control modulating valves and not fan motor.
Solar Water Heating
Solar Electric Systems Self contained terminal air conditioning units or heat pumps shall include:
Wind Turbines
Passive Solar Heating Centrifugal evaporator and condenser fans, direct connected.
Passive Solar Cooling
Building Material Motor, three speed permanent split capacitor type with oilers.
Water Conservation
Ground Source Heat- Condenser and evaporator coils, electric heating element or hot water coil.
Pumps
Green Hotels Hermetic compressor.
Glass &Windows
Selection Unit casing shall be 18 gauge steel top and sides, 16 gauge steel base zinc coated phosphatised and finished in enamel.
Aluminium outdoor air louvre with adjustable damper. Aluminium shall be clear anodised, 1 hour in accordance with Alcoa Spec.
215R1.
Sizing: Base peak cooling loads for selection of guestroom fan coil units on peak exterior loading with sheers closed, two people
per room and 250 watts per room electric load. Select capacity of fan coil unit to maintain room thermostat setting at medium fan
speed. • Supply Air: Quantity equals 102 m3/hr (60 cfm) per
guestroom.
Back to Hotels
Back to Hvac Expert Main Page
HVAC Technician Training Learn refrigeration and air conditioning technology at home. www.PennFoster.edu
FlatPlate Heat Exchangers Compact, High Performance, Heating, Refrigeration & Process Made in USA www.FlatPlate.com
Honeywell Distributor Allied Has the Honeywell Parts You Need. Order Today! AlliedElec.com/Honeywell
Search
Web www.iklim.com
http://www.iklimnet.com