EPCON_C6_Plus_+_Typ._Threaded_Rod_Grade_8.8_M16-02_07_2024

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Ref : 7/2/2024 - 10:47:02 AM / Version 2023.11.

22
Date : 7/2/2024
Page : 1/4

CALCULATION SHEET FOR RAMSET ANCHORS


Company : Phone number :
Carried out by : Mail address :
Company : Project name :
Contact name : Location :
Phone number : Fastening point :
Mail address :

Comment :

Recommended anchors Product Code: NA


EPCON C6 Plus + Typ. Threaded Rod Grade 8.8 M16 / hef = 190 mm Effective embedment : 190 mm
ETA-18/0675 issued 2021/06/06
For self Cleaning: Use Ramset Dustless Drilling System
methodAdhesive Part Number: REO502J or REO502JEF
Base material
Concrete resistance : C20/25 - fck,cyl = 20 N/mm²
Cracking of concrete : Cracked concrete
Thickness of concrete : 300 mm
Reinforcement type : Wide concrete reinforcement
Edge reinforcement : No edge reinforcement

Conditions
Installation conditions : Dry concrete
Short term temperature : 40 °C
Long term temperature : 24 °C

Anchor plate
Thickness of part to be fixed : 8 mm
Recommended plate thickness : The base plate thickness has not been checked

Clearance diameter : 18 mm
Profile :
Profile position : Ex = 0 mm ; Ey = 0 mm
Stand-off : None

Design method : European/NZS 3101 for seismic loading


Design Actions :

Action [kN] / [kNm] Action type

Combination 1 seismic 26.2 14.1 0 0 0 0

Specifications :
Seismic category : C1
Structural Elements
Working life : 50 years
Building importance class: II
Seismicity level (AS 5216:2021 - Table F.3.1): ag.S ≤ 0,05.g
No filled holes
Design options:: For Capacity Design, input the seismic actions corresponding to the yield or the maximum force that can be
Ref : 7/2/2024 - 10:47:02 AM / Version 2023.11.22
Date : 7/2/2024
Page : 2/4

Geometry :

Calculation Hypothesis :
- The anchoring plate is assumed to be sufficient to resist deformation imposed by the load actions.
- Connection between profile and base plate has not been checked

- RAMSET can only be held responsible if the calculation examples exactly reflect the application and if the installation is carried
out according to the instruction given in the RAMSET specifications. The calculation is correct for RAMSET anchors only. The
contractor or specifier should make sure that the base material is able to support the loads especially in the case of a group of
anchors. RAMSET cannot be held responsible if this software package is modified without its written approval.
Ref : 7/2/2024 - 10:47:02 AM / Version 2023.11.22
Date : 7/2/2024
Page : 3/4

Resulting anchors forces

Loads on anchors

Anchor Tensile Shear[x] Shear[y]


1 13.1 kN 7.05 kN 0 kN
2 13.1 kN 7.05 kN 0 kN

26.2 13.1 0 0

14.1 7.05

Utilization

Tension load Tension force [kN] Strength [kN]


Combined pullout-concrete cone failure 26.2 52.88 49.5
Concrete cone failure 26.2 38.03 68.9
Splitting failure 26.2 40.13 65.3
Steel failure 13.1 84 15.6

Shear load Shear force [kN] Strength [kN]


Concrete Edge failure / / /
Pryout failure 14.1 45.57 30.94
Steel failure 7.05 13.94 50.57

Combined tension and shear loads

THE APPLICATION IS SAFE


Ref : 7/2/2024 - 10:47:02 AM / Version 2023.11.22
Date : 7/2/2024
Page : 4/4

INSTALLATION DATA

EPCON C6 Plus + Typ. Threaded Rod Grade 8.8 M16 / hef = 190 mm Product Code: NA
Effective embedment : 190 mm
ETA-18/0675 issued 2021/06/06

Minimum stud length: 214.5 mm


Effective embedment : 190 mm
Minimum thickness of base material : 226 mm
Hole diameter in the base material : 18 mm
Hole depth in the base material : 190 mm
Installation torque : 95.00 Nm
Base plate thickness : 8 mm
Profile family (section type) :
Clearance diameter : 18 mm

INSTALLATION Method