Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

12,600

A 2,900
B 1,900 C 3,400
D 4,200
E

1,500
A 2,900 B 1,900 C 3,400 D 4,200 E
1,600 A B C 12,600 D E 1,000
1 1 1 1
1 1

Balcony
KITCHENETT

GENTS

4,010

4,010
4,010
8,000

4,750

DINING AREA
Tt Tt LIVING ROOM
BEDROOM 1 BEDROOM 2
B/RM
PHARMACY
1,600
1a 1a
1a 1a

941

941
B/RM 1a 1a
Tt Tt

941
2 2
2 2

DOWN
2 2

DOWN

2,000

2,000
DOWN

20
19
18
17
16
15
14
13
12

10
11
SHADE

20
19
18
17
16
15
14
13
12

10
11

1
2
3
4
5
6
7
8
9
20
19
18
17
16
15
14
13
12

10
11
LADIES

2,000
175.0 R x20

1
2
3
4
5
6
7
8
9

UP
Balcony
250.0 G x19
175.0 R x20

1
2
3
4
5
6
7
8
9
UP
3 3
250.0 G x19
175.0 R x20

UP
250.0 G x19
3 3
3 3
3,950
BEDROOM
WHOLE SALE

Balcony
SHOP

4,850

4,850
LIVING ROOM

4,650
SHADE

4,650

4,850
8,100 1,600

KITCHENETT

23,700

23,900
1,600
4 4
23,900

4 4 DINING AREA

4 4
HARDWARE
30,500

DINING AREA
SHOP

KITCHENETT
SHADE

4,850

4,850
8,100

4,650

4,850
7,051

BEDROOM
PARKING AREA

Balcony
LIVING ROOM
5 5
5 5

DOWN
DOWN

2,200

2,200
20
19
18
17
16
15
14
13
12

10
11
20
19
18
17
16
15
14
13
12

10
11

5 5

1
2
3
4
5
6
7
8
9
175.0 R x20
1
2
3
4
5
6
7
8
9

UP
250.0 G x19

DOWN
200

175.0 R x20
UP

6 6
250.0 G x19

2,200
20
19
18
17
16
15
14
13
12

10
11
6 6

1
2
3
4
5
6
7
8
9
175.0 R x20

UP
250.0 G x19
SHADE

HARDWARE 6 6
3,450

3,450

SHOP

4,848

4,848
BEDROOM

Balcony
1,200 8,100
LIVING ROOM

4,848
4,650
200

SHADE 7 7
KITCHENETT
7 7

200
1,198

A B C D E
DINING AREA
2,900 1,900 3,400 4,200
7 7

A B C D E A B C D E
PARKING AREA
5,100

TYPICAL FIRST TO FIFTH FLOOR PLAN 13,000

FOUNDATION LAYOUT
DETAILS
GROUND FLOOR PLAN -1.8X1.8M Bases
-Columns 300mx300mm with 8T16 bars
ACCESS ROAD -Depth minmum 1.8m
- Ground Beam of 300x200

PROJECT NAME & ADDRESS CLIENT Drawn By Supervised By Revision to be encased in 150mm thick concrete sorround
Drafted & designed by
General Notes
ARCHITECT
-All work to be strictly in accordance to the standard
-All sanitary works to the approved standards of
M.Shafik M.Shafik -Unless otherwise stated the dimensions are in mm. specifications and notes.

Proposed Commercial SCALE DATE


-The contractor should not scale off the drawing, -This drawing is to be read in conjuction with specification
Public Health Department

rather, should use writen dimensions. -All roads,storm water,drainage and foul sewage to civil
BEAM TEC ENGINEERS LTD
Building, To Be Built on Plot....., Mr. NYANZI BENJA -This drawing is a copyright (c)
and all other relavant drawings
engineers drawings.
Design, Build,Remodal
AS SHOWN JUNE 2024 -Depth of foundation to be determined on site
Location; Kawempe Tula,P.o.Box,106903,k'la Block......,Kiwuwo, Mityaana -All levels and dimensions to be checked on site
-Permanent Vents to be included above all doors and
Tel; +256759348918, +256704051494 before building work commences. -A single layer of 3- ply bituminous felt to be provided.
windows
info@beamtecengineers.com
Website; www.beamtecengineers.com
District. PROJECT NO. -Any discrepancies to be reported to the office of the
-Drain pipes passing under tarmac, drive ways, and building with mosquito gauze.This does not apply to toilet doors
consultant,
GSPublisherVersion 0.0.100.100