Handpiece D-ACTOR
Publisher:
STORZ MEDICAL AG
Lohstampfestr. 8
CH-8274 Tägerwilen
Switzerland
24887
Table of Contents
1 System description 6
1.1 Handpiece 6
1.2 Transmitters 7
2 Installation Instructions 8
2.1 Unpacking 8
2.4 Compatibility 9
3 Operation 10
3.1 Start-up 10
3.7 Treatment 21
Table of Contents
19 920 02 0614
4 Cleaning, Maintenance, Overhaul 23
4.1 Cleaning 23
4.1.1 Changing the transmitters . . . . . . . . . . . . . . . . 24
4.1.2 Cleaning the handpiece . . . . . . . . . . . . . . . . . 25
4.1.3 Cleaning the transmitters . . . . . . . . . . . . . . . . 27
4.2 Overhaul 28
4.2.1 Contents of the D-ACTOR overhaul kit . . . . . . . . . . . . 28
4.2.2 Overhauling the handpiece . . . . . . . . . . . . . . . . 29
4.3 Maintenance 33
4.4 Disposal 33
4.5 Repair 33
8.2 Service 37
Table of Contents
19 920 02 0614
Preface
Warning notes
DANGER!
WARNING refers to a situation of potential danger which, if not avoided, could lead
to serious injury.
WARNING!
4
CAUTION indicates that incorrect operation could lead to minor injuries.
CAUTION!
ATTENTION indicates that incorrect operation could lead to damage to the device.
ATTENTION!
19 920 02 0614
Other instructions
NOTE
WARNING !
For all regulations and instructions for the protection of the person to be treated and
for the use of the control device and the handpiece please read the general Safety
inStrunctiOnS of the operating manual of your control device.
Preface
19 920 02 0614
1 System description
1.1 Handpiece
Radial, low-energy pulses (D-ACTOR) are administered into the body by means of
a freely movable handpiece, and encompass the entire pain zone. Radial pulses are
often also referred to as radial pressure waves – which is indeed physically correct. The
handpiece is placed on the pain zone that has been established by diagnosis.
1 2 3 4
1 Transmitter
2 Transmitter screw
cap
3 Shaft cushion
6 4 Display
5 Handpiece handle
5
6 Handpiece shaft
The D-ACTOR handpiece contains all the control and display elements required for
operating the device as a standalone unit (see chapter 3 OperatiOn).
6
The D-ACTOR handpiece is also updated immediately after it is connected when there
has been a software update of the system.
NOTE
19 920 02 0614
1.2 Transmitters
The handpiece is used with different transmitters.
Each of these transmitters generates its own characteristic effect (see user
information).
1 C15, Ø 15 mm
2 DI15, Ø 15 mm
3 F15, Ø 15 mm
4 D20-S, Ø 20 mm
5 D35-S, Ø 35 mm
1 2 6 D20-T, Ø 20 mm
3 4
5 6
System description
19 920 02 0614
2 Installation Instructions
2.1 Unpacking
Remove the instrument and accessories from the packaging container. Proceed
with extreme caution.
Check that all items are included in the packaging container and that they are not
damaged.
Contact your supplier or the manufacturer immediately if any items are missing or
damaged.
1
1
2
Installation instructions
1 red dots
1 connector for the D-ACTOR handpiece 2 outside of the plug body
19 920 02 0614
Insert the plug of the handpiece into the handpiece connector on the control
device.
While inserting, make sure that the red dots on the plug and connector are lined
up above one another.
Gently pushing the plug into the connector will immediately lock the connection
and will prevent the connector from disengaging automatically when the cable is
pulled.
locking function, allowing the plug to be pulled out of the handpiece connector.
2.4 Compatibility
The STORZ MEDICAL D-ACTOR handpiece is allowed to be operated on the following
control devices:
– STORZ MEDICAL D-ACTOR 50
– STORZ MEDICAL D-ACTOR 100
– STORZ MEDICAL D-ACTOR 200
– STORZ MEDICAL CELLACTOR SC1 BT
– STORZ MEDICAL D-100
Installation instructions
19 920 02 0614
3 Operation
The handpiece operates using the embedded display. The settings can be adjusted
manually or pre-programmed settings can be adopted.
WARNING !
3.1 Start-up
NOTE
To start up the control device, please refer to the separate operating manual for
your control device.
Connect the D-ACTOR handpiece to the control device (see chapter 2.3 cOnnecting
10
handpiece).
NOTE
If the control unit is changed to which the handpiece is connected, so an adap-
tion process starts. This process takes about 2 minutes and will be visible on the
display of the handpiece.
Operation
19 920 02 0614
Operation
11
CD = control device
Info 7 - Software version - CD
HP handpiece
19 920 02 0614
Info 8 - Hardware number - HP
Info 9 - Hardware number - CD
Info 10 - Boot load number - HP
3.2 Info 11 - Boot load number - CD
3.3 Standard display
After switching on the display shows the last set values.
– Now you can set the energy level and the frequency, reset the treatment puls
counter, change to the main menu and release puls waves.
1 2 1 Reduce pressure
2 Increase pressure
6
3 Reduce frequency
4 Increase frequency
7 5 Trigger button
10 11
8 6 Display pressure
7 Nominal pulse
9 counter
3 8 pulse counter
4
9 Display frequency
10 Key combination with
12 double function
(see text)
11 Key combination
5
(change to the menu)
By pressing the particular button once the pressure will be increased or reduced in
single steps.
By pressing and holding the particular button after the second step the pressure will
be regulated faster.
Operation
19 920 02 0614
3.3.2 Setting the frequency
The pulse frequency can be selected in steps from 1,0 Hz to 21 Hz.
By pressing the particular button once the frequency will be increased or reduced in
single steps.
By pressing and holding the particular button after the second step the frequency will
be regulated faster.
= 11
19 920 02 0614
3.4 Main menu
From the main menu the operator can change into the following options:
– Program selection
– nominal value of pulses
– Informations
Press button 3 to change from menu to the corresponding option in the main
menu.
1 2 1 2 1 2
14
4 4 4
3 3 3
Operation
19 920 02 0614
3.4.2 Menu program selection
With the menu program selection a reference number can be selected, which is
related to an indication.
parameters for the pressure, frequency, nominal value of the pulses and the applicator
to be used for this application in your application brochure.
Press button 1 to show the previous reference number.
Press button 3 to change from menu to the option program selection in the main
menu.
3 4
15
pulses as well as the proposed applicator are shown. You can adopt them or change
them.
19 920 02 0614
Selecting treatment step
You can choose between two treatment steps.
Press button 1 to show the previous treatment step.
Press button 3 to change from indication mode to the option program selection in
the main menu.
Display parameters
After the nominal value of pulses from treatment step 1 is reached treatment stops
automatically. The display returns to the level treatment steps however to treatment
step 2.
16
After the nominal value of pulses from treatment step 2 is reached treatment stops
automatically. The display automatically returns to the standard display (see chapter
3.3 Standard diSplay).
Operation
19 920 02 0614
Program selection
1 2 1 2
10 11 10 11
3 4 3 4
3 back to program
selection
17
1 2 1 2
1 Reduce pressure
10 11 10 11
2 Increase pressure
3 3 Reduce frequency
3 4 4
4 In crease frequency
5 Trigger button
5 (more functions
see. text)
19 920 02 0614
-
quency, nominal value of pulses and the applicator to be used for this application
which are recommended by users.
In the menu parameter selection the display changes between the selected reference
number with treatment step and the value of the pulse counter every 2 sec.
to the option nominal value of pulses in the main menu. (see Fig. 3 - 7).
Press button 4 to cancel the selection and return to the menu nominal value of
pulses (see Fig. 3 - 7).
3 4
Operation
19 920 02 0614
3.4.4 Menu Information
Press button 1 to show the previous info menu point.
In the menu information the following information can be read out and the pulse
counter can be resetted
1 Reset pulse counter (see chapter 3.3.3 reSetting the pulSe cOunter)
2 Total pulse counter of the handpiece
3 Operating hours of the handpiece
19
4 Total pulse counter of the device
5 Operating hours of the device
6 Software version - handpiece
7 Software version - device
8 Hardware number - handpiece
9 Hardware number - device
10 Boot software number - handpiece
11 Boot software number - device
Under info point number in the menu information the pulse counter is displayed.
The display shows the pulse number.
Press button 4 and afterwords simultaneously the buttons 1 and 3 to reset the
revision pulse counter.
Operation
19 920 02 0614
3.4.5 Changing to standard display
Check that the triggered pulses are correctly counted on the treatment pulse counter.
NOTE
Set the nominal value counter to the required value. The '-' symbol appears if zero
NOTE
The pulse frequency beginning with 1 Hz and also the energy level beginning with
1.0 bar can be increased in steps up to maximum value depending on the control
device.
Operation
19 920 02 0614
3.7 Treatment
Before using the device, the user must make sure it is functioning safely and in proper
condition.
Each time after the device has been transported, make sure that all functional
checks have been performed on the device before you start treatment. Read about
this in chapter 3.5 functiOnal checkS.
CAUTION !
chapter general Safety infOrMatiOn in the operating manual of your control device
is not permitted!
21
CAUTION !
CAUTION!
19 920 02 0614
3.7.2 Setting parameters
Treatment should always start at a low energy level. This also applies to resuming
treatment after an interruption. The pulse energy should be increased gradually
during treatment. The low levels are used less for therapy and more for familiarising
the person to be treated.
Select a low energy level and frequency
OR
Load an indication and administer the treatment according to the
recommendations of the treatment parameters stored in the system)
NOTE
The selection of energy levels is based on the opinion of the operator adminis-
tering treatment. The maximum energy level used during treatment must not
cause the person to be treated undue pain under any circumstances.
Avoid excessive pressure of the transmitter to the patient‘s skin. Excessive pressure
is not needed for the success of the treatment.
22
V-ACTOR
Make sure that the pulse counter is at zero and a low energy level has been set.
19 920 02 0614
4 Cleaning, Maintenance, Overhaul
4.1 Cleaning
Regular cleaning ensures perfect hygiene and operation of the D-ACTOR handpiece.
The handpiece, in particular the transmitter, must be thoroughly cleaned and disin-
fected after each therapy session.
CAUTION !
Disconnect the handpiece from the control unit before starting any
cleaning or maintenance work.
ATTENTION !
its tubing.
Clean the coupling gel off the handpiece using a cleaning agent that is suitable for
surface cleaning.
23
Disinfect the handpiece with an alcohol-based disinfectant that is suitable for
surface cleaning (follow the manufacturer’s instructions).
19 920 02 0614
4.1.1 Changing the transmitters
NOTE
The handpiece is equipped with a projectile safety catch device in order to prevent the
projectile from being ejected in case a pulse is released while the transmitter and the
transmitter screw cap are removed.
The safety catch is also activated if the transmitter screw cap is not screwed on tightly, if the
sealing ring between the cap and the transmitter is missing or if two sealing rings (old and
new) come together at the rear of the transmitter.
CAUTION !
Disconnect the handpiece from the control unit before starting any
cleaning or maintenance work.
24
19 920 02 0614
6 After replacing the transmitter, make
sure that the handpiece cap and the
NOTE
Make sure that the two cap parts of the D20 and the D35 transmitters are
shaft.
Check the screw connection of the transmitter screw cap and cap parts during
prolonged treatment phases
components.
25
Disconnect the handpiece from the control
1 device.
3
Clean the coupling gel off the handpiece Cleaning, Maintenance, Overhaul
using a cleaning agent that is suitable for
surface cleaning.
Disinfect the handpiece with an alcohol-
based disinfectant that is suitable for
surface cleaning (follow the manufacturer’s
instructions).
19 920 02 0614
4 Unscrew the shaft from the handpiece and
pull it out of the handpiece handle (5).
Use the supplied open-end spanner (4) for
this purpose.
26
Cleaning, Maintenance, Overhaul
19 920 02 0614
4.1.3 Cleaning the transmitters
Unscrew the transmitter screw cap and remove the transmitter insert from the
transmitter screw cap.
NOTE
The transmitter insert with the D20-S, D20-T and D35-S can only be dismantled
and the sealing rings can only be removed using special tools. You should avoid
doing this because it could result in damage to the transmitter. It is not necessary
for cleaning purposes.
27
Clean and disinfect not only the transmitter insert but also the transmitter screw
cap with the usual alcohol-based cleaning agents and disinfectants.
Dry the transmitter and transmitter screw cap before screwing them together.
19 920 02 0614
Push the insert into the front cap and screw the two cap parts together until
NOTE
Make sure that the two cap parts of the D20 and the D35 transmitters are
shaft.
Check the screw connection of the transmitter screw cap and cap parts during
prolonged treatment phases
4.2 Overhaul
Pulses are generated mechanically. Due to the effects of friction, the handpiece com-
ponents are continuously exposed to mechanical stress, which will cause minor wear.
NOTE
The D-ACTOR handpiece should be overhauled about every 1,000,000 pulses.
This can be done quickly and easily by the user of the device. All that is required is
the overhaul kit, which includes all required wear parts.
The overhaul kit can be ordered from your dealer quoting part number 17212.
Cleaning, Maintenance, Overhaul
NOTE
The sealing rings, the projectile and the guide tube must always be replaced each
time the handpiece is overhauled. Observe the O-ring Guide when selecting the
sealing rings to be used. It is contained in the overhaul kit.
19 920 02 0614
4.2.2 Overhauling the handpiece
CAUTION !
Disconnect the handpiece from the control unit before starting any
cleaning or maintenance work.
ATTENTION !
An open-end spanner has to be used to release or to assemble handpiece
shaft when overhauling the handpiece.
29
19 920 02 0614
5 the shaft. If necessary, use a thin metal
rod or the supplied hexagonal spanner as
a pulling tool by inserting it through the
openings in the guide tube.
30
8
F15
C15
Cleaning, Maintenance, Overhaul
DI15
Dispose of the detachable sealing rings of the C15, DI15, F15 transmitters and the
sealing ring on the shaft.
19 920 02 0614
Clean the shaft, the transmitter (including
9
transmitter screw cap using a disinfectant
containing alcohol. These are reused after
cleaning.
NOTE
D20-S
The transmitter insert of the D20-S, D20-T
and D35-S can only be dismantled and
D20-T the sealing rings can be removed only
with special tools. You should avoid doing
this because it could result in damage
to the transmitter. It is not necessary for
D35-S cleaning purposes.
31
DI15
19 920 02 0614
Take out the new guide tube and the new
10
projectile from the overhaul kit.
12 guide tube.
32
Screw the shaft into the handpiece until
13
Carry out a functional check of the handpiece (see chapter 3.5 functiOnal checkS).
19 920 02 0614
NOTE
Pictures of handpiece and transmitters are examples. Individual components may
differ from those shown in the illustration.
Reset the overhaul pulse counter (see chapter 3.3.3 reSetting the pulSe cOunter).
4.3 Maintenance
Preventive maintenance is not necessarily required.
4.4 Disposal
the service life of the handpiece, please return the instrument to STORZ MEDICAL AG.
4.5 Repair
33
Repair work on defective instruments must only be carried out by personnel suitably
authorised by STORZ MEDICAL. Only original STORZ MEDICAL parts may be used for
this purpose. The personnel suitably authorised can be from STORZ MEDICAL or be
representatives of STORZ MEDICAL agencies and dealers.
19 920 02 0614
5 Error messages and trouble-shooting
No power output Leaks in handpiece cable Check the cable and tube
or cable not properly connections and replace
connected them, if necessary
34
pictographic
Cause Corrective actions
error messages
19 920 02 0614
6 Accessories and Spare Parts
Handpiece D-ACTOR
Handpiece D-ACTOR 21700.0001
Handpiece D-ACTOR LT 23213.0001
D-ACTOR overhaul kit 17212
Red sealing sleeve 19475
Transmitters
Other accessories
19 920 02 0614
7
Handpiece D-ACTOR
Compressed air input 1.0 - 5.0 bar
Ambient temperature
10 – 40 °C
during operation
Ambient temperature
0 – 60 °C
during storage and transport
Ambient air pressure
800 - 1,060 hPa
during operation
Ambient air pressure
500 - 1,060 hPa
during storage and transport
Air humidity
5 – 95%, non-condensing
Storage and transport
Air humidity
5 – 95%, non-condensing
operation
Weight 480 g
NOTE
36
When the product is distributed to third parties, the following must be
observed:
This device complies with the applicable standards EN 60601-1, CAN CSA-C22.2 No.
601.1, UL Std. No 60601-1.
For information about conformity with directives, please refer to the separate operat-
ing manual for your control device.
19 920 02 0614
8 Warranty and Service
ATTENTION !
M
37
8.2 Service
Should you have any further questions or require additional information, please feel
free to contact your dealer.
19 920 02 0614
Warranty ans Service
38
19 920 02 0614