DESCRIPTION

MAIN DIMENSIONS (SI-SYSTEM)


FLoFREEZE® MX 02 freezer
2000 505
1800

912
3000
L
1500*
Front view

3700
4700
740-1235

1230
850

Rear view
1400

Model L
MX 32 3800
MX 42 5000
MX 52 6200
MX62 7400
MX72 8600
MX 82 9800
MX 92 11000
MX 102 12200
All sizes available in right or left hand model.
Shown: right hand model

* 500 mm without control panel on this side.


For more detailed information and connections, see layout draw-
ing for each model.

MANUAL 0242 - 01 - 01 - 02 - 13 1/2


DESCRIPTION
TECHNICAL DATA - (SI-SYSTEM)
Model MX 32 MX 42 MX 52 MX 62 MX 72 MX 82 MX 92 MX 102
1)
Capacity kg/h 1800 2400 3000 3600 4200 4800 5400 6000
Infeed temperature °C + 15
Outfeed temperature °C - 18
Refrigeration
Standard design 2) R717 (Ammonia). Pump circulation ratio: 4-6 times evaporation.

Evaporation temperature °C - 40 °C at coil


B a se l o a d kW 56 69 83 97 110 123 137 152
B a se l o a d Kcal/h 48200 59400 71400 83400 94600 105800 117800 130700
3)
Required capacity kW 232 303 376 449 520 592 665 738
Kcal/h 199500 260500 323300 386100 447100 509000 571800 634600
Coil volume (litre) litre 310 440 570 620 750 880 1010 1140
Electrical data
Voltage 3 x 400 V, 3 x 415 V; 50 Hz or 3 x 440 V; 60 Hz
Normal power consumption kW 42 55 69 82 95 108 122 136
4)
Max. power requirement kVa 67 84 100 116 133 149 166 182
Motors of more than 1 kW rating at - 3x13.2 4x13.2 5x13.2 6x13.2 7x13.2- 8x13.2 9x13.2 10x13.2
30 °C(installed power) +2x4.0 +2x4.0 +2x4.0 +2x4.0 + 2x4.0 +2x4.0 +2x4.0 +2x4.0
Defrosting
Water consumption during lit/min 360 465 595 360 360 465 465 595
defrost 5) +360 +465 +465 +595 +595
6)
Track rinser lit/min 3 x 52
Required air volumes
ADF - air defroster 7) lit/sec 22 22 33 33 33 33 45 45
TDF - track defroster 8) lit/sec 22 22 22 22 22 22 22 22
Required air capacity (lit/sec) lit/sec 44 44 55 55 55 55 67 67
Noise emissions According to Machinery Directive 89/392/EEC, 1.7.4 (f)
Along freezer walls Maximum 90 dB(A)
During TDF-shot, In front of in- and Maximum 102 dB(A)
outfeed openings
During ADF-shot, along evaporator wall Maximum 98 dB(A)
1) Based on green peas. For other products see manualsheet "Product capacity".
2) As there are orifice plates in the coil circuits, there must be a filter in front of the connection (not del. by FSE).
See Manual shee t"Freezer connections" (Only before installation).
3) To compensate for fluctuations in processing line production capacity, a 10 % margin has to be added. For more
detailed information please contact Frigoscandia.
4) Value for dimensioning of power supply cables/fuses. Valid for 50 Hz system.
5) 150 kPa (1,5 bar) at connection point and at rated flow. Spraying time ~ 15 min. Water temperature +50 °C, gives
two hours turn around time, colder water temperature gives longer turn around time. For more information please
contact Frigoscandia Application Group.
6) 150 kPa (1,5 bar) at connection point and at rated flow.
7) Temperature max 30 °C and 700 kPa (7 bar).
8) 400 kPa (4 bar), free of oil and water, 5 sec. interval.

~~~