Download as pdf or txt
Download as pdf or txt
You are on page 1of 24

Aditya

ADITYA ENTERPRISES
(AN ISO 9001:2008/CE CERTIFIED CO.)

STATIC RELAYS
AUTO MAINS FAILURE (AMF) RELAYS
MOTOR CONTROL RELAYS
ALARM / ANNUNCIATION SYSTEM
TRANSFORMERS
BATTERY CHARGERS

CREATING NEW HORIZONS IN POWER PROTECTION AND CONTROL


Aditya Enterprises
About Us :

Aditya Enterprises was established in 2008 with a vision to provide high quality products & services to the customers.
It has also the ambi on to provide healthy atmosphere to work & grow its employees with its own growth. Company
has team of about 40 people & total working space is more than 3000 sq. .

Our Team :

In Aditya we have a high qualified ( B. Tech & Diploma ) team of Engineers with more than 15 years of experience in
industry in designing high quality & sophis cated products. Our produc on team has technicians with more than 10
years of experience in assembling & tes ng electronic equipments.

Our Quality Policy :

Aditya Enterprises is commi ed to provide best quality products & services to its customers as per agreed terms &
condi ons. In order to achieve this , we are con nually improving processes, products and services mee ng &
exceeding customer sa sfac on at all mes. To achieve our quality policy commitment we have appointed two quality
engineers to check the products technically & visually. Products are tested under different atmospheric condi ons like
high temp, under heavy vibra ng base etc. Aditya Enterprises possess the ISO 9000:2015 and CE cer ficates.

Our Produc on Team :

Director

Purchase Accounts Production Q.A. Sales Service


Team Team Team Team Team Team

Products & Services :

Aditya Enterprises is involved in manufacturing high quality products widely used in Automa on,
Power Protec on and Control. Some of them are men oned below :
1.Voltage Monitoring Relays.
2.Current Monitoring Relays.
3.Reverse Power Protec on Relays.
4.Phase Sequence Correc on Relays.
5.Single Phasing & Reverse Phasing Protec on Relays.
6.Annuncia on Systems.
7.Ba ery Chargers.
8.Power Packs and many more.
Alarm Annunciators Aditya
ADITYA ENTERPRISES
(AN ISO 9001:2008/CE CERTIFIED CO.)

Panel Cutout: 69x139 mm Panel Cutout: 69x139 mm Panel Cutout: 69x139 mm Panel Cutout: 139x139 mm
Overall Size 72x144x140 mm Overall Size 72x144x140 mm Overall Size 72x144x140 mm Overall Size 144x144x140 mm

Aditya Microprocessor Based Alarm Annunciators are


designed to keep an alert & watchful eye on your plant &
processes. The entire range has been designed with an
insight into the modern day manufacturing plant & its
future requirements. Aditya Alarm Annunciators are
AE: 906 M AE: 902 M AE: 904 M AE: 936 M
equipped with micr oprocessor-based design, super
bright LED windows, Panel Cutout: 139x139 mm Panel Cutout: 139x139 mm Panel Cutout: 139x139 mm Panel Cutout: 92X189 mm
Overall Size 144x144x140 mm Overall Size 144x144x140 mm Overall Size 144x144x140 mm Overall Size 96X192X140 mm
Dynamic, Aler t & Responsive…These unique ADITYA
ADITYA

advantages have helped the Aditya Annunciators an


icon in the power T & D industry & engineering
establishments in India. The world class Aditya
Annunciators has made its pr esence felt in Overseas AE: 93
8M

markets. AE: 932 M AE: 930 M AE: 938 M AE: 934

Panel Cutout: 189x92 mm Panel Cutout: 189x92 mm Panel Cutout: 189x92 mm Panel Cutout: 92X92 mm Panel Cutout: 92X92 mm
Overall Size 192X96X140 mm Overall Size 192X96X140 mm Overall Size 192X96X140 mm Overall Size 96X96X144 mm Overall Size 96X96X144 mm
Features :
• Powerful Microprocessor Based circuit.
• Special SMPS power supply.
• Sleek, modern, aesthetic design AE: 930

AE: 931 A AE: 931 AE: 932 AE: 930 AE: 933

PARAMETERS
Ordering Information Supply Voltage 12 / 24 / 48 / 110 / 220 V DC 110 / 240 V AC +10% –15% 24 V AC, 90 - 270 V AC / DC
•Model Name Windows 4 / 6 / 8 / 12 / 16
•No. of windows Display Device Super bright high efficiency low power consuming LED's
•Aux. Supply Window/LED Colour Standard colour available RED,
•Operation Sequence Flash Rate Fast - 60 flashes
•Optional Features Required Response Time 25 msec. ± 10 msec.
Output Contacts 2C/O, 1 NO for hooter
Contact Rating 5 Amps 240 V AC (Resistive)

Operational Temp. 0-60 degrees C


Power Consumption 0.5 Watts per Window
Optional Grouping / AC-DC fail Annunciation / Repeat Relay contacts

Annunciation windows (12 Windows)


Principal of operation :
Aditya Annunciators are designed designed to work in robust condition like during
system vibrations, high ambient temperatures, dusty atomsphere. During
operation if any of the fault occurs the corresponding window starts
ashing, internal buzzer starts sounding, external hooter C-NO gets
closed & Trip contacts get energised i.e C-NOs get closed & C-NC get open.
On pressing Ack, the light stops ashing & become steady, internal hooter
switches OFF. After removing fault if RESET is pressed then the system gets
reset condition i.e normal condition.

Technical Specifications :
1. Supply Voltage : 24 Vdc+/-4V
2. No. of input Faults : 12 (Faults should be potential free)
3. Output Contact rating : 5A@230Vac.
4. Flashing Duty cycle : 1-1.2 sec.
5. Power consuption on stand by : 3VA max.
6. Power consuption on faults : 12VA max.
7. Insulation between output contacts & internal circuit :> 1 Mohm.
8. Size cutout : 139mm * 139mm
9. Physical size of the unit : 144mm(H)* 144mm(V)* 160mm(D)
General wiring diagram for Annunciator 12 Windows
Aditya
ADITYA ENTERPRISES
(AN ISO 9001:2008/CE CERTIFIED CO.)

STATIC RELAYS
AUTO MAINS FAILURE (AMF) RELAYS
MOTOR CONTROL RELAYS
ALARM / ANNUNCIATION SYSTEM
TRANSFORMERS
BATTERY CHARGERS

CREATING NEW HORIZONS IN POWER PROTECTION AND CONTROL


Aditya
ADITYA ENTERPRISES
(AN ISO 9001:2008/CE CERTIFIED CO.)

VOLTAGE MONITOR RELAY UNDER+OVER VOLTAGE ENGINE STARTING RELAY TIMERS AC - DC


ALTERNATOR VOLTAGE RELAY
OVER VOLTAGE RELAY AC 230V AE 100
Single phase AE 230 DC 12V /24V AE 150 DC 12 or 24VDC
Single phase UOVR UV 160 -220V
VMR 160 -260V AE 200 OV 230 -300V ON delay Ini ally off, a er
AVR 160 -260V AE 202 AE 100 set me mer on -
OVR 220 -300V AE 201 Three Phase AE 240 contacts change
UOVR UV 300 -400V
Three Phase OV 420 -500V Off delay Ini ally on, a er
VMR 300 -400V AE 210 AE 130 set me mer
AVR 300 -400V AE 212 turns off-
OVR 400 -500V AE 211 Aditya Voltage relays are used in Aditya Engine star ng relays are used contacts change.
protec on of gensets motors, pump, for automa c star ng of Diesel / Stop mer Ini ally on, a er
transformers, shunt caps etc from petrol engines or Gensets and fire AE 130 set me off. For
Aditya Voltage relays are used in
damage due to transient blackouts, engines. Relay is a three a empt pulling stop
protec on of gensets, motors,
brownouts 7 for auto start stop of cranking relay for engine star ng solenoid of engine
pumps, transformers, shunt caps etc
AMF panels A low or high in all or any with auto cut a er 3 a empts. On for 5-30sec.
from damage due to transient
phase generates a changeover signal. me and off me dura on’s are Signal of Same as Off delay
blackouts, brownouts & for auto start
Two poten al free c/o contacts are se able from 0-30 seconds. Two Delay except mer starts
stop of AMF panels. A low or high in
given for breaker tripping - Relay is changeover contacts are given - for AE 132 only when
all or any phase generates a
auto reset Both under & over & cranking the engine and for lockout external signal
changeover signal. Two poten al
voltage are se able. Time is fixed at in case the engine fails to start in given
free c/o contacts are given for
breaker tripping - Relay is auto reset. 3-5 sec Hysteresis of 5-15V for three a empts. The relay locks out
transient Protec on is transient a er 3 a empts. Time delay is as per order which are
Both me & voltage are se able
Hysteresis of 5-15V for transient Protec on is provided
Size : 70 x 60 x 110 mm * 1-10 sec* 10 - 100 sec
Protec on is provided
* 6-60 sec* 0.3-3 min
Size : 70 x 60 x 110 mm * 1-10 min
Size : 70 x 60 x 110 mm
All contacts are 5A poten al
free. Any of these mer can be
specified at order.

Size : 70 x 60 x 110 mm

Size : 13 x 6.75 x 9.5 Inch Size : 12 x5.5 x 8 Inch Size : 9.25 x 3.5 x 5.5 Inch Size : 9.25 x 3 x 5.5 Inch

Ba ery Chargers
Aditya Ba ery chargers are designed to bear voltage varia ons, fluctua ons & have low voltage
regula on.

Opera on : When the ba ery is connected & then provide input voltage 230Vac. It starts
charging the ba ery.
Aditya Transformers
While Charging : Aditya transformers are guaranteed for its best quality
Supply Indica on : ON, Charging Indica on : ON Whenever the ba ery gets fully charged along
core and original & pure copper winding.
with supply indica on & charging indica on ba ery full indica on also glows. Again when the
ba ery voltage goes below its rated voltage the ba ery full indicator switches off and ba ery
starts changing. Specs : as per customer requirement.

Ba ery Chargers : 12Vdc/6A, 12Vdc/10A


24Vdc/8A, 24Vdc/10A, 24Vdc/16A, 24Vdc/20A, 24Vdc/25A
Aditya
ADITYA ENTERPRISES
(AN ISO 9001:2008/CE CERTIFIED CO.)

OVER CURRENT RELAY 3 Element over current AE530 REVERSE POWER RELAY FREQUENCY RELAY AE700
EARTH FAULT RELAY 3 Element 2OC / 1EF AE531 AE 800 SPEED RELAY AE
EARTH LEAKAGE RELAY
Earth Fault 0.2 - 2A Over Frequency 50 - 55 Hz
Over Current 0.5-5A AE 510 Over Current 0.5-5A SENSING Over Speed 1500 - 1650 rpm
Earth Fault 0.2-2A AE 520 Reverse Power - 6 - 10%
Earth Leakage 50-500mA AE 560 AE 530 series or Over current relays AE 700 series frequency relays
are ideal for sensing over current are used for protec on of
Aditya Current Single element Over faults in any or all phases for sensi ve equipment due to
current/ Earth Fault / Earth leakage protec on of AC machines, AE 800 series RPR relay monitors the
under or ment is being supplied
relays are ideal for sensing current Transformers, Generators etc. power flowing in the phases. The
faults in any one phase or earth for direc on of the power is checked. from a source whose frequency
The relay monitors the current
protec on of AC machines, passing in any feeder secondary. The The relay monitors current flowing in may be erra c. Can be used for
Transformers, Generators etc. The resultant current is digitally the B phase. This Current is squared tripping in case frequency goes
resultant current measured is compared. Each phase has its with the voltage in RY phase and above limit. A lower or higher
digitally compared to a se able independent se ng. Timer starts on motoring condi on detected. Power than limit condi on if persis ng
refernce. In case of trip condi on trip trip condi on and is common for all sensed is compared to a reference for more than 1 or 2 sec a contact
contacts changeover a er a se able three phases - a changeover occurs. and a mer is triggered above limit. changeover occurs and an led on
me of 1 - 10 sec. This can be used to Time must be set a according. Two Timer can be set 0-10 sec. Contacts
facia glows to indicate a trip
trip the breaker. Time must be set sets of changeover contacts are changeover occurs on meout and
according to system requirement. an led indica on signals closure. condi on. This can be used to
available - common for all.
Two changeover contacts are trip the breaker / supply. Two
available. sets of changeover contacts are
available. The relay is auto reset
type.

Size : 70 x 60 x 110 mm Size : 70 x 60 x 110 mm


Size : 70 x 60 x 110 mm Size : 70 x 100 x 110 mm

Size : 96 x 96 mm

Size : 144 x 72 mm
Cutout Size 138 x 68 mm

ANNUNCIATOR 4F AE 930 ANNUNCIATOR 8F AE931


ANNUNCIATOR 10F Ae932
Aditya Annunciator 4 fault annunciators are digital units with front end it
by led’s. Applica ons are in monitoring fault condi ons in any process, Aditya Annunciator 8 / 10 fault annunciators are digital units with front
equipments etc A poten al free fault condi on triggers a buzzer, trip end lit by led’s. Applica ons are in monitoring fault condi ons in any
contact and a contact for hooter if external hooter is desired. Also the process, equipments etc A poten al free fault condi on triggers a buzzer,
corresponding window flashes, two changeover contacts trip to signal trip contact and a contact for hooter if external hooter is desired. Also the
fault condi on. When the acknowledge pushbu on is pressed the flashing corresponding window flashes, two changeover contacts trip to signal trip
becomes steady, the buzzer stops and the hooter contact is released. Test indica on and an internal buzzer beeps to signal fault condi on. When the
checks all the windows. acknowledge pushbu on is pressed the flashing becomes steady the
buzzer stops and the hooter contact is released. Test checks all the
windows.
Size : 96 x 96 x 140 mm
Cutout Size 92 x 92 mm Size : 144 x 144 mm
Cutout Size 138 x 138 mm
Aditya
ADITYA ENTERPRISES
(AN ISO 9001:2008/CE CERTIFIED CO.)

CYCLIC TIMERS AC AE 140 PUMP CONTROLLER PHASE SEQUENCE SINGLE PHASE PREVETOR
STAR DELTA TIMER AE 136 CORRECTOR RELAY AE 1100
Single Tank AE 1010 AE 400
Cyclic Timer Double tank AE 1020
ON 0.2 - 2 hrs
OFF Time 0.2 - 2 hrs Single tank pump controller is used to Used for protec on of motors,
Time can be provided as per monitor the overflow and / or pumps, transformers, etc from
Requirement prevent overflow as well as switch on damage due to missing phases or Single phase preventor is used for
pump when tank empty. Useful for nega ve phase sequences. A wrong protec on and burnouts of pumps
STAR DELTA single tank opera on of sequences is corrected and two and motors against phase
Star me 6 - 60 sec underground or overhead tank. output contacts are provided which unbalance, missing and nega ve
Double tank pump controller is used can be used to switch on the power phase sequence. All the phases are
Cyclic mers are used in cyclic to switch on pump when overhead contactors . Only the correct con nuously checked. A fault trip
opera on of two motors where tank is empty and shut of pump when sequence contactor signal will be on condi on trips the relay -
alternate pumping is required. Time overhead tank is full. Dry rum at a me. However contactors must changeover contacts are energized.
can be ordered as per requirement. protec on against underground tank be interlocked during power wiring. The relay resets automa cally and
Standard mes are 0.2 - 2 hrs is also provided. The relay resets automa cally and remains off when voltage is low
Separate changeover contacts for ON remains off when voltage is low, zero zero, unbalanced or nega ve phase
and OFF mes - Star Delta mers are unbalanced or nega ve phase sequence. Manual reset can be
used for star ng star delta motors. At sequence. Manual reset can be provided.
power on star connec on is made for provided.
selecable me a er which delta
connec on is made.

Size : 70 x 45 x 110 mm
Size : 70 x 100 x 110 mm
Size : 70 x 60 x 110 mm
Size : 70 x 60 x 110 mm

AMF RELAYS STATIC RELAYS MCC PANEL RELAYS


MOTOR PROTECTION RELAYS
Ÿ TIMERS Ÿ TIMERS
Ÿ ENGINE START RELAYS Ÿ VOLTAGE RELAYS Ÿ TIMERS
Ÿ VOLTAGE RELAYS Ÿ INSTANTANEOUS OVERCURRENT Ÿ STAR DELTA TIMER
Ÿ 1 PH CURRENT RELAYS Ÿ 1 PH CURRENT RELAYS Ÿ CYCLIC TIMER
Ÿ 3 PH CURRENT RELAYS Ÿ 3 PH CURRENT RELAYS Ÿ PHASE SEQUENCE CORRECTOR
Ÿ FREQUENCY RELAYS Ÿ FREQUENCY RELAYS Ÿ SINGLE PHASE PREVENTOR
Ÿ SPEED RELAYS Ÿ EARTH FAULT RELAYS Ÿ PUMP / WATER LEVEL
Ÿ ANNUNCIATION UNITS Ÿ CUSTOMISED RELAYS CONTROLLERS
Ÿ CUSTOMISED RELAYS

Applica ons : Applica ons : Applica ons :


Auto start, stop and protec on of Protec on of sensi ve equipment’s Motor control protec on, Pump
amf panels and genera ng sets both on the source side and load protec on.
during power failure. Annuncia on side. These relays are extremely
units can provide visual indica on for sensi ve and very accurately
generator faults and healthy calibrated.
condi ons. We can also make custom We can also make customized
relays and custom design for amf relays.
panels.

Authorised Dealer

ADITYA ENTERPRISES (AN ISO 9001:2008/CE CERTIFIED CO.)

New Delhi - 110 019. INDIA


Scanned by CamScanner
Our Major Customers :

1. Trisquare Switchgears Pvt. Ltd. ( Sonipat, Haryana)


2. Milestones Switchgears Pvt. Ltd. ( Gurgaon, Haryana)
3. Geetu Electricals Pvt. Ltd. ( NOIDA,UP)
4. Indo Econ Systems ( Lucknow, UP)
5. Anupam Engineers ( Lucknow, UP)
6. Asiatic Electrical & Switchgear Pvt. Ltd. ( Bhiwadi, Rajasthan)
7. MR Enterprises ( Faridabad, Haryana)
8. Indra Electrical Control (Jhandewalan, Delhi)
9. OM Traders ( Baagirath Place, Delhi)
10.Suneja Electrical( Baagirath place, Delhi)
11. Sri Sai Trading Co.( Baagirath Place, Delhi)
12. Kamal Industrial Electrical ( Govind Puri, New Delhi)
13. Servo Star India Pvt. Ltd. ( Delhi)
14. AR Electricals ( NOIDA, UP)
15. SVAM Power Pvt. Ltd. ( Auth. Service Provider Cummins
Engines/ Gurgaon, Haryana)
16. ASES Security Pvt. Ltd. ( Sahibabad, UP)
17. V-Tech Automation ( Gurgaon,Haryana)
18. Varun Technologies ( Gurgaon, Haryana)
19. Akshay Patra Equipments (P) Ltd. ( Gurgaon, Haryana)
20. Precision Systems Control (P) Ltd. (Govt. Contractor/ NOIDA, UP)
21. Ahluwalia Constructions ( NOIDA, UP)
22. Laxmi Electro mech Control ( Delhi)
23. Perfect Generators Technology Pvt. Ltd. (Mahindra DG OE/ Ghaziabad)
24. Nova Power System ( Delhi)
25. Jankoch Corporation ( Exporter/ Kolkata, WB)
26. Shine Metal Udyog Pvt. Ltd. ( Eicher Engines OE/ Faridabad, Haryana)
27. MAAS Generators Pvt. Ltd. ( Eicher Engines OE/ Gurgaon, Haryana)
28. Govind Electrical ( Delhi)
29. Trading Engineers International Ltd. ( Roorkee, UK)
30. Electro Equipments ( Roorkee, UK)
31. Digital Control ( Govt. Contractor/ Faridabad, Haryana)
32. JVV Electrotech Pvt. Ltd.
33. Sterling Generatrors Pvt. Ltd.
Plot No. 98, B - Block, Gali No. 5
Vinay Nagar Faridabad
Haryana, 121003 (Iindia)
E-mail : adityaenterprises343@gmail.com
vinodkumar549984@gmail.com
Website : www.adityaindia.co.in
Mob. : +91- 9873549984

You might also like