Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Simplified Liquid Mode

Standards:
• ASTM D 5453
• ASTM D 6667
• ASTM D 7183
• ISO 20 846
TOTAL LICENSE

ERALY & ASSOCIÉS – 4 Rue Georges Besse – Bâtiment i – 78330 FONTENAY-LE-FLEURY, France - Mail : contact@eraly.com
TOTAL SULFUR ANALYSIS:

SULF UV SL is a Total Sulfur analyzer by UV Fluorescence. It is mainly used for petroleum products,
solvents, oils, synthetic products, etc..... This equipment offers unrivaled advantages due to its
robustness, reliability and precision. This equipment provides tranquility and avoids high and
recurring maintenance costs.

THE ULTRA PERFORMANT DETECTOR:

Equipped with a soft adjustment and a high-


performance optical module, it is the only
device capable of dosing with excellent
sensitivity and signal stability, the very low
contents up to 20 ppb of Sulfur and at the
same time the high contents up to 10% of
Sulfur.
With its Liquid Crystal Display (LCD), it allows
the operator to display in real time:

→ Real-time synoptic flow diagram display ; Intensity of the UV Lamp signal,


→ Intensity of the PM signal; The pressure of the measurement chamber
→ The inner and outer temperature, The state of the measurement chamber,
→ Alarms regarding all possible problems.

PRINCIPLE OF OPERATION:

After introducing the sample into the combustion tube, it undergoes a pyrolysis followed by an
oxidation of sulfur to SO2. SO2 molecules absorb a UV radiation and go from a fundamental
(normal) state to an electronic excited state. When returning to their fundamental (normal) state,
they emit fluorescence radiation which will be measured by a photomultiplier tube (PM).

CALIBRATION:

• A single point of calibration is


enough because the detector
has a linear response (1% of the
point)

• A multipoint calibration can be


done if needed.

• The most stable detector on the


market. It allows to keep a
calibration for several months
Operation diagram (without furnace)

ERALY & ASSOCIÉS – 4 Rue Georges Besse – Bâtiment i – 78330 FONTENAY-LE-FLEURY, France - Mail : contact@eraly.com
THE COMBUSTION SYSTEM:

As a manufacturer of tubular furnaces for industry and for


scientific research, we pay a particular attention to the Do not forget it!!! The
reliability of the results of
design of the combustion systems of our analyzers. Our
your measurements also
combustion systems offer the possibility of pyrolysis before depends on the
oxidation. This ensures complete combustion and a dosage combustion efficiency of
your samples.
of all the sulfur contained in your samples.

Do not waste your time anymore:


- replace your catalyst more easily and quickly,
- take advantage of the hourly / daily programmer to put it to standby or to automatically start the
apparatus, oven, gas ....

ELIMINATION OF INTERFERENCES:

The SULF UV SL allows measuring the very low levels of sulfur contents even in the presence of
high concentrations of nitrogen. The aromatic hydrocarbon filter ensures the total elimination of
interferents. Integrated in a measuring chamber, it is compact. No more clutter with additional
modules.

DESIGN THAT ADAPTS TO YOUR SPACE:

With its two modes of configuration, Vertical


furnace and Horizontal Furnace, the SULF UV SL is
adaptable to your environment.

Principle Combustion – UV Fluorescence

Detection Limit 10 ppb to 10%


Quantification 20 ppb to 10%.

Accuracy At 0,1 ppm At 1 ppm At 100 ppm


RSD 0.61 % 0.48 % 1.04 %.

Injections 20 to 80 µl liquids 1 to 25 ml gas 10µL LPG

Supply: gas Oxygen Argon


99.998% - 3 bar 99.995 % - 3 bar.

Electric 110 V / 230 V


60Hz – 50 Hz
1200 W

Temperature Furnace F2 25 to1050°C.

DIMENSIONS Length Height Depth


VERTICAL CONFIGURATION 46 cm 65 cm 56 cm
HORIZONTAL CONFIGURATION 84 cm 48 cm 55 cm

ERALY & ASSOCIÉS – 4 Rue Georges Besse – Bâtiment i – 78330 FONTENAY-LE-FLEURY, France - Mail : contact@eraly.com
ACCESSORIES

GAS AND LPG AUTO SAMPLER:

➢ Composed of a 6 ways 2 positions valve with


sampling loop, for Gas / the same for LPG.
➢ LPG expansion volume, 15 ml.
➢ Temperature of LPG expansion volume adjustable
between 50 and 150°C (nominal 80°C).
➢ Compatible with standard: ASTM D6667.
➢ Handle by our Software MIPO5.
➢ Standard ASTM D6667

Used for sampling and injecting gases and LPG.

AUTOMATIC LIQUID SAMPLER:

➢ Tray of 25 to 50 positions for vials between 2 to 8 ml.


➢ 3 axes system for sampling / injecting / rinsing.
➢ Sampling volume adjustable between 10 µl and 100 µl.
➢ Sampling speed adjustable.
➢ Handle by our Software MIPO5.
➢ Tray and number of positons customizable according your need.

Used for sampling and injecting Liquids

MINI AUTOMATIC LIQUID SAMPLER:

➢ Equipped of a tray with 5 to 7 positions, plus trash


and rinsing vials.
➢ System with a multiway valve for sampling / injecting
and rinsing.
➢ Sampling volume adjustable between 10 µl and 80
µl.
➢ Sampling speed adjustable.
➢ Handle by our Software MIPO5
➢ Ideal for a small number of samples.

Used for sampling and injecting Liquids

ERALY & ASSOCIÉS – 4 Rue Georges Besse – Bâtiment i – 78330 FONTENAY-LE-FLEURY, France - Mail : contact@eraly.com

You might also like