Download as pdf
Download as pdf
You are on page 1of 9
W DAIKIN DAIKIN FLOOR STANDING Space saving with style and functionality SSS SS ———- SSS SSS SS SSS Se SS SS SS ——_—— FVRN125/160BXV1(42,000-55,000Btu/h) (cw - (Left side) (Front) (Right side) Wired controller: Wireless oA prear air flow BRC51A62 BRC52A62 ie ‘GRO “Tye Daikin Floor Standing is able to achieve alr flow * optional supplied with unit ~ noite 288 Gistance as far as 25m (size 160) which is about the size of a basketball court, = 2 7 & z 3 = E 5 5 alz 3 et 2|8 5 I 2 2 g | 23/8 g Z| ¢/2|&.| 2 | 2 Pele celle cele aia ailaele z/2)]2 Ble | 3 5 | & | § /ss|28| 32 | 3 —|3s| 5 5 3 Ss | 2) 28/52] 83 2/28/s/2 |2/] $ & =) 22/23] 83 —|3 7 3 £ 3 /ée/— | 22 gs = £ 2/5 |< é & 3\4 efelfe[afelfa ° elfelelelel| 2 “1 Applicable when wired controller is used. *2 The condenser comes with bare/blue fin. Gold fin condenser are optional Auto-swing mode ‘This unit uses its automatic horizontal swing louver to ‘spread Comfortable air flow to cool every corner of the room. Its vertical louvers are adjusted mannually to match different interior spaces and partition as well as to avoid direct airflow orn re] cep User-friendly controls ‘The Unit comes with a stylish black control panel with white LED light for clear. it comes with a keylock function to, prevent setting change from unauthorised Personnel Off stato On stato ‘Addtionaly, This units incorporated with infrared sensor for usage with wireless contrller ‘whichis supplied wih the unit. Tus, itcan be controlled using wireless controler for greater flex Two selectable temperature sensors Both indoor unit and wired remote controller (option) contain temperature-sensors. Temperature sensing can be set atthe unit or, to further improve comfort level, closer to the target area atthe wired remote control. This feature must be set during commissioning by the technicians. * Temperature-sensor on indoor unit must be used when the ar conditioner is controle from anathar room. “+ Wireless remote controller doesnot have a temperature-sensor Switchable fan speed High/Medium/Low High setting provides maximum reach while low setting minimizes drafts. HON? (Co x White spay ight up to ind v ‘modes and temperature stings when switched on| oe Keylock ion displayed when activated _._Keylock funtion: Activation / eatvation of keylock by pressing “SWING and "TURBO" together Timer selector Operation starts when the preset time of the ‘on’ timer lapses and stops when the preset time of the ‘off timer lapses. Powerful operation New powerful operation boosts airflow to maximum volume fora 20-minute period with highest fan speed. After this, the unit automatically returns to its previous settings. Indoor unit on/off switch ‘The unit can be conveniently started manually in the event the wireless remote controller is misplaced or the wireless remote controller batteries are not changed COME UCU Safety clip The safety clip feature allows users to remove the washable saranet filter with ease during maintenance. At the same time, italso acts as a sefety feature to prevent the users from Teaching into the electrical and mechanical components. ph Space for water drain pump There is a space in the unit below the fan that allows users to install an external condensate water pump. "Tho condensato water draln pump is separately purchased and field installea fer Outdoor unit CHOY OM Me) CeO Equipped with scroll compressor for quiet operation ‘Smooth running, minimal vibration, low operating sound (for RRIO0DAXV1/V1 and RR125-160DAXY1), Sine) RRI250 60 RR1600 6 Fitted with wide inlet fan Fully shaped aerodynamic propellers are designed to push air with a large wing surface, providing both high blow volume and quiet operation with turbulence. Bey ROWE RR125/160DAXY1 Pre-charged for up to 7.5 metres i Max. ath, m Max. ping o RRI250 50 30 R60 35/45" 18/25" * Only applicable for FVRN16OBXV1 Durability + The unit is covered with corrosion-proof galvanized steel to enhance its durability. + Heat exchange fins are provided with anti-corrosion treatment. Wireless controller BRC52A62 (D "Glow-in-the-dark' on/off ©) Vertical auto-swing ‘switch ® Selectable mode: @ Fan speed selection: Cool, Dry, Fan Low, Medium, High, Auto @) Turbo function @ Temperature setting: ® Quiet function Up & down 10 On timer setting @ Sleep mode function |f9 Real time clock & Off timer setting (@) Real time clock and day ® Turbo function ® display ® Cool, Dry, Fan mode La (2) Temperature operate in ® : ® Delay timer (1 or 2 hours) 8 Penida 3 CoN 3 rye perenne nr Pepa Nien Gis ia oo Gre ; fan speed ‘unction © Onvoff switch Wired controller BRC51A62 can directly be connected to the unit's main board to start operating without extra setting or modification. It also hase a built-in temperature sensor that enables temperature sensing closer to target area improved comfort (no settings required to activate the handset temperature sensor). EE Signal sent from 65 wireless handset Network Controls Control by external command using BMS Access Gateway (BAG) BAG interfaces the air conditioner unit to BMS system via input contacts, resistance inputs and dry contacts outputs which allows the monitoring and controls of the air conditioner. The BAG enables: ‘+ Controls ofthe air conditioner unit's on/off status, operating mode, fan ‘speed setting, room temperature setting as well as forcing off the unit in the event of fire. ‘+ Indication to warn the control room in the event of air conditioner failure. + Maximum point-to-point distance of 1100m (please refer to the installation manual) Input Input Contos Applications = Forceotun-ctanged | Smoke arm system Dae Ua contacts on Long stance unt one cool Resistance | Temperate setng Long distance unt trpwrature The BAG controls consist of: inputs (is°c-30°C) sattng control + Mainboard Sonne Pe ens nee] om ee con + BAG controller Relay Oniott status ‘Long distance unit operation status: + Communication bus outputs Unit faultyinormal ‘monitoring Individual air conditioners can be turned on fr Note: Communication bus: ‘A 2-way twisted pair cable is used as the communication bus. Recommended cable for communication bus is a pair of screened and shielded, twisted single core wire with core diameter of 0.5mm to 1.0mm. Floor standing Met Indoor unt URN290xV1 FVRNo8xv1 Cutdor unt RSOAKY! AARIGODAXY! Nominal cooling capacity Buh 2.000 55,000 w 12310 16,120 ‘Nominal total input power Ww 4,100 5,490 Nominal running current A 658 95 ER wow 300 298 ‘Power supply: ‘WIPhIHZ. '380-415/3/50 (power from outdoor) Indoor Airflow (H/M/L) etm 1035/945/845 1170/1085/985, a ‘Sound pressure level (H/M/L) aB(A) 49/47/44 54/53/51 Dimensions (HxWxD) mm 185046004250 ‘Machine weight 45 ot ‘outdoor | Sound prosure iv wy 5 nt Dimensions (HxWxD) mile opto 1852x1030x400 owen Machine weight Ka 95 105 Piping connections Liquid Fare) | mm ase as (Far) mm 1528 1905 ‘Max. interunit piping length m 50, 45 ‘Max. intlation lv ference m 0 25 Rated cooling capacities ae baad onthe folowing conditions: Indoor temp. 27°CDB, 18°CW; outdoor temp. 36°CDB: piping length: 75m SEMEN 01-00/20 PA Warning ‘+ Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm ‘with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or ‘modify the application of any local legislation, ‘Use only those parts and accessories supplied or specified by Daikin. ‘+ Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and ‘warnings. Be sure to follow these instructions and warnings. I you have any enquiries, please contact your local importer, distributor and/or retailer. PW DAIKIN + Speteaton, ces ae har content sopra ochre canta of Feary 2020 bu sett change mht ae. ‘oni rears VP DAIKIN Floor Standing Type = FVRN Series R-410A 42,000- 55,000 BTU/hr nie, | aRogease Specifications teint) “opana Siena ery Gel ore ral Coving Capacty AW 1201 16:12 (owenshnoudu) Bum 42,000 5,000 oriral total input power GosmsBuasnuhsivtsh) bad sais ae Norminal running eurent Gasmnstinszeludy) A 658 938 EER (iusanémansstwoutu) ww 3.00 294 Power supply (wéstui) ViPhikie 300-415 V/3 Phase / 50 Hz FVRNTZSEXVt en Dimension HeWxD) VR wna gundixén) pon 1,850 x 600 x 350 ‘iow een HM. roi FO35 / 945 / BAS 4,470 1,085 / 985 Gosimsnyuseubome) sea ‘Sound Pressure (6803) wn | 4B) 49/47 144 5463/51 Weight (hin) cg 45 51 Eiranad fone (ore endo) ' mm (852 x 1030 x 400 ‘Sound Pressure (suse) HAN. 8A) 60 6 ‘Weight (Grin) ig % 105 Piping Connection Liquid Fare) | _mm 95 ae) Gas (Flare) | _mm 15.9 194 ‘Max nteruit Piping Length mn a iz (r2wsomsduriogugo) ax installation level dference ee) m 30 2B ‘awmunsciumstnnawdurimucsomama:dhay 4x8 eoasndommmeia : 27 008, 19°Cwe / meuontio; : 95°COB / nawenasaurioghen : 7.5 m (wu2sw) sursnbeullregga 25 uns (Gu FvERHO)

You might also like