ENGINEERING CO., LTD Email: assamasrip®@dohwra.co.kr, Mobile: +91-700276754
To
Authorized Signatory,
SHIVAM-BHARTIA (JV)
Mis Shivam Bracge JV, Zoo-Narengi Road,
Geetanagar, Guwahati -21,Assam
Project: Construction Supervision Consultancy Services for Improvement and Upgradation
of Roads under ASRIP Sarthebari Pathsala road under Package no: ASRIP/A/RI-4
‘Subject: Regarding Source Approval of Ramco cements limited.
Ref: SB (JV/ASRIP/Cement-01/2022-23/58(A) dated 07.06.2022
Dear Sir,
With respect to the above subject, there is no objection in using 43 grade ordinary Portland
Ramco Cements Ltd brand cement, provided it is tested in accordance with the methods
given in 1s:4032:1985 and found complying with the criteria , and also comply with the
chemical and physical requirement as per 1S:6112:1989.
In your letter itis not clear that which grade are you going to use in the project, and you have
submitted the credential of IS-269, with the BIS certificate valid up to 20-02-2021, which is
not accepted by us.
‘As per para-1 of IS-269, the cement covers the physical and chemical requirements of 33
grade ordinary Portland cement
The para- 8.1 states, that the manufacturer shall satisfy himself that the cement conforms to
the requirements of this standard and, if requested, shall furnish a test certificate to this
‘effect to the purchaser or his representative, within ten days of testing of the cement (except
for 28 days compressive strength test results, which shall be furnished after completion of
the test). The type and percentage addition of performance improver(s) shall also be
indicated in the certificate.
{As stated in para-10.3 BIS Certification marking the cement may also be marked with the
‘Standard Mark and as per para-10.3.1 the use of the Standard Mark is governed by the
provisions of the Bureau of Indian Standards Act.
In view of above, it is informed that as per your submissions, the BIS certificate is up to 20-
02-2021 and not meeting the project requirements as per clause 901.10 of MORTH
specifications as the essential tests are to be carried out at the manufacturer's plant, Hence
the undersigned is not in a position to give consent to “The Ramco cements Ltd” for using in
our Project road.
ET
Corporate Office ee et panes
DBohwa incla Branch Office =
‘A101, Thum Tower, Sector 62,Noids, Uttar Pradesh — 201301 CVR. GAM ANATHRY >
mall abhilash@dohwa,co.kr_
a eee aera
DOHWA [QQSSES) taecna ore sencsmnerate cmt apr
Thanking You,
For Dohwa MaRS (JV)
oe ee
V. R. Ramanathan
Team leader cum Senior Highway Engineer
CSC, ASRIP
Guwahati
Copy To:
4. The Chief Ebgineer (EAP) Fatasil Amabri Guwahati 25 - For kind informati Please
2. Resident Engineer for Pathsala — For necessary action and follow up.
3. SQME for Necessary action and follow up.