EIE INSTRUMENTS PVT.

LTD
Feature list of
Digital Microcontroller Based Bomb CalorimeterWith Inbuilt
Thermal Printer

1. State of art technology microcontroller based which makes the unit


accurate and highly stable for measurement of temperature to calculate
the calorific value experiments in bomb calorimeter.
2. JUMBO size 16 x 2 characters LCD display with backlight.
3. Timer control through RTC(Real Time Clock) which makes it highly accurate.
4. Thermal printer for printing the final result.

5. Thermal printer Printout Report Format for SAMPLE TEST


a. COMPANY NAME and LOGO
b. TYPE OF TEST :- SAMPLE TEST
c. MAX.TEMPERATURE RISE
d. MASS OF TABLET
e. WATER EQUIVALENT
f. FINAL CALCULATED CALORIFIC VALUE
g. DATE & TIME OF TEST

6. Thermal printer Printout Report Format for Water Equivalent Test


a. COMPANY NAME
b. TYPE OF TEST :- WATER EQUIVALENT TEST
c. MAX.TEMPERATURE RISE
d. MASS OF TABLET
e. BENZOIC ACID CALORIFIC VALUE
f. FINAL CALCULATED WATER EQUIVALENT
g. DATE & TIME OF TEST

7. 16 soft-touch Keypad for Menu driven settings of different parameters.


8. Automatic detection of temperature rise& fall.
EIE INSTRUMENTS PVT. LTD
9. Automatic measurement and mathematical calculation of the calorific
value/Water Equivalent; which eliminates the requirement of operator to
be continuously present to note the maximum temperature rise &to do the
calculations manually.
10.Weight of tablet settable through keypad by user.
11.Water equivalent settable through keypad by user.
12.Automatic calculation for Sample Test or Water Equivalent Test from
maximum temperature rise value.
13.Full test report printout with date and time& company name.
14.Temperature scanning resolution of 0.01 degree Celsius.
15.Automatic alarm on Firing as well as after the test completes.
16.Sensor open detection.
17.Fuse wire open detection through message on LCD.
18.No paper or printer door open detection.
19.User friendly system handling messages on LCD
20.Type of test selectable
21.Memory storage for data.
22.Fuse Wire & Cotton error adjustable.

Menu Operations.
The user friendly keypad control allows user to operate the menu easily. The
following menu items help user to feed the data easily for calculation of Calorific
value .

 Press MENUKEY to enter the menu settings.


 First item of menu “ TYPE OF TEST “ gets displayed on the screen .Press
UPKEY /DOWNKEY to choose either of the 2 type of tests “SAMPLE TEST “
or “WATER EQUIVALENT TEST”.

TYPE OF TEST
Use UP/DOWN KEY
EIE INSTRUMENTS
Sample Test PVT. LTD

Press Up/Down Key

Water Equi.Test

 To select any of these tests press ENTER KEY.

Press Enter Key


Test Selected

 If test selected is “WATER EQUIVALENT TEST”then enter the value of water


equivalent “W =” through keys 0-9 on the keypad.

Press 0-9 keys


Water Equivalent
W = 3456
 If test selected is “SAMPLE TEST”then enter the value of Benzoic Acid
Calorific valve “ H=” through keys 0-9 on the keypad.

Press 0-9 keys


Benzoic Acid C.V
H = 2897
EIE INSTRUMENTS PVT. LTD
 Press MENU KEY to come back to main menu.

Press Menu Key

TYPE OF TEST

 Press UP KEY to switch next item in menu “MASS OF TABLET”. If the type of
test selected is SAMPLE TEST the screen displays “MASS OF TABLET” in the
upper line and “M =” on lower line. Using the 0-9 keys on keypad the user
will set the value of the required parameter. Else if the type of test selected
is WATER EQUIVALENT TEST the screen displays “BENZOIC ACID MASS” in
the upper line and “M =” on lower line. Using the 0-9 keys on keypad the
user will set the value of the required parameter.

Press Up Key

Mass of Tablet
M= 0.000gms

Press 0-9 keys


Mass of Tablet
M= 1.000gms

If test selected is Water equivalent then screen displays

Benzoic Acid Mass


M= 1.000gms
EIE INSTRUMENTS PVT. LTD

 Press ENTER KEY to come back to the same menu item. To scroll to next item
in menu press UP KEY.
 Pressing UP KEY moves to next item in menui.e“ OFFSET :- ”.Press
UP/DOWN KEY to change the value of offset.

Offset:-
Use Up/Down Key
 Press ENTER KEY to come back to menu item from settings and press UP KEY
to move to next item “CLOCK “ .

Clock
29/05/12 12:47
 The display shows clock settings in format “ DD/MM/YY HH:mm ”.The arrow
pointing shows the parameter to be set using UP/DOWN KEY. Press MENU
KEY to move arrow to next parameter and follow the same procedure to set
every other parameter.
 Press ENTER KEY to move out to main menu.
 Press UP KEY to move to next item in menu “EXIT”. Press ENTER KEY the
screen comes out of menu and displays the main screen contents.

EXIT……
EIE INSTRUMENTS PVT. LTD
Procedure to operate the machine.
 Upon switching the unit the LCD display shows the name of the
company and name of the machine “ DIGITAL BOMB COLORIMETER”.

EIE INSTRUMENTS
WORKS

DIGITAL BOMB
CALORIMETER

 The thermal printer prints the company name and address along with
the machine name and company logo.
 Immerse sensor in the water the screen displays the Ambient
Temperature and Clock on the LCD.

Amb. Temp:25.05⁰C
29/05/12 17:45

 If fuse wire is open the message is displayed on the screen and if not
the screen displays the message “ FUSE WIRE OK “.

FUSE WIRE OK

 Press Fire button given on the keypad for firing the unit .

FIRING >>>>>>>>>>>
EIE INSTRUMENTS PVT. LTD

 As the temperature starts rising the LCD updates the temperature in


0.01 degree C resolution.
 The digital unit calculates the maximum rise of temperature
automatically and the LCD displays “ MAX.TEMP = “ on the upper
line and “RISE. TEMP = “ on the lower line.

Max.Temp: 1.34 ⁰C
Rise. Temp: 1.32⁰C

 The parameters set in the menu helps the micro processor based
digital unit to automatically do the mathematical calculations and
display the calculated CALORIFIC VALUE of the substance and give
the thermal print out report simultaneously to the user.

Cal.Val= 473.23
Max.Temp:2.05⁰C

Water Eq.= 2345


Max.Temp:4.65⁰C

 Thermal Print out Report format for Sample Test:


1. "SAMPLE TEST"
2. "MAX.TEMPERATURE= XX.XX ⁰C"
3. "WATEREQUIVALENT= XXXX"
4. "MASS OF TABLET=X.XXX GMS"
5. "CV= XXX.XX"
EIE INSTRUMENTS PVT. LTD
 Thermal Print out Report format for WATER EQUIVALENT:
6. "WATER EQUIVALENT TEST"
7. "BENZOIC ACID CV= XXXX"
8. "MASS OF TABLET= X.XXX GMS"
9. "WATER EQUIVALENT= XXXX"

Any suggestions for improvement are always welcomed.

WRITE TO :
EIE INSTRUMENTS PVT. LTD.
(AN ISO : 9001 – 2000 CERTIFIED COMPANY)

B-14, ZAVERI INDU. ESTATE,


OPP. SHYAM VILLA, SINGARWA KATHWADA ROAD,
KATHWADA, AHMEDABAD-382430
PhNo : (O) 22901462, (FAX) : 22165580

To adjust Fuse Wire & Cotton Error.

Keep EXIT key pressed & then switch on the power of the firing unit after the
name of the machine has been displayed, release the EXIT Key & now the unit
will ask for Error. Feed the new error & exit.

IMPORTANT: while the process is running, the unit will automatically detect the
fall of rising temperature which may take some time. If the user feels to exit the
test process at the peak temperature, the user can press the EXIT key. The unit
will calculate the results with the max. temperature on the display & will show
& print the result.