1
Organization’s ISO 9001:2008 Certificate
2
Forward
We just want to take a moment out to thank you for your keen interest in our company products. We
greatly appreciate your business and the opportunity you provided us to assist you. You have joined a
selected group of customers who have switched to the technologically superior and quality enhanced
laboratory testing product.
Time has changed, so do the technology. Your purchase lists you on the cutting edge of 21st century
technology. The attached test report is an excellent way of expressing and maintaining your trust in
EIE’s - superior quality testing products. Our continued efforts and commitment is to provide you
efficient sales after services, prompt attention and highest level of customer satisfaction. If for any
reasons, you have questions or comments, we are delighted to hear from you. Call us on 0091-79-
66040601 or send us email at info@eieinstruments.com/kunal@eieinstrumentsc.com. You can expect
us to respond to your email within 24-48 working hours.
Once again, thank you for your trust and kind patronage. We look forward to serve you better in
future.
Yours sincerely,
EIE Instruments
3
Table of contents
Forward ................................................................................................................................... 3
8. Troubleshooting ......................................................................................................... 10
4
1. Definitions of Cloud & Pour Points
Pour point
The pour point of a liquid is the lowest temperature at which it becomes semi solid and loses its flow
characteristics. The Pour point describes a procedure for testing the fluidity of a petroleum product at a
specified temperature.
Cloud Point
The Cloud point is defined as the temperature of a liquid specimen when the smallest observable cluster
of wax crystals first appears upon cooling under prescribed conditions. The cloud point of a fluid is the
temperature at which dissolved solids are no longer completely soluble, precipitating as a second phase
giving the fluid a cloudy appearance.
This term is relevant to several applications with different consequences. In the petroleum industry,
cloud point refers to the temperature below which wax in diesel or bio wax in biodiesels form a cloudy
appearance. The presence of solidified waxes thickens the oil and clogs fuel filters and injectors in
engines. The wax also accumulates on cold surfaces (e.g. pipeline or heat exchanger fouling) and forms
an emulsion with water. Therefore, cloud point indicates the tendency of the oil to plug filters or small
orifices at cold operating temperatures.
In this test method, Cloud point and pour point are indicators of the lowest temperature of utility for
petroleum products. The sample is periodically examined while it is being cooled in the cloud and pour
point apparatus. The highest temperature at which haziness is observed (cloud point), or the lowest
temperature at which movement of the oil is observed (pour point), is reported as the test result.
The test can be performed in the laboratory on the prepared samples or in-situ on location.
5
3. Required apparatus and material to carry out this test
1) Test Jars
A cylindrical test jar of clear glass, flat bottom, 30 to 33.5 mm in inside diameter, and 115 to 125
mm in height. To indicate sample height, the jar should be marked with a line 54 ± 3 mm (2 1/8 ±
1/8 in) above the inside bottom.
2) Thermometer
Thermometers, having ranges as shown below and conforming to the requirements as prescribed
in ASTM Specification E 1 for ASTM Thermometers or in the Specifications for IP Standard.
Thermometers
Thermometer Number
Thermometer Temperature Range
ASTM IP
Cloud and -38 to + 50 °C 5C IC
Pour -36 to + 120 °F 5F IF
Low Cloud -80 to 20 °C 6C 2C
and Pour -112 to +70 °F 6F 2F
3) Cork
A cork to fit the test jar bored centrally to take the test thermometer.
4) Copper Jacket
A copper jacket is watertight, cylindrical jacket of glass or metal, flat bottom, about 115 mm in
depth. With inside diameter 9.5 to 12.5 mm greater than the outside diameter of the test jar.
5) Disk
A disk of cork or felt, 6 mm in thickness and of the same diameter as the inside of the jacket is
provided.
6) Gasket
A ring gasket of about 5 mm in thickness to fit snugly around the outside of the test jar and Loosely
inside the jacket is incorporated. This gasket may be made of cork, felt, or other suitable material
which is elastic enough to cling to the test jar and hard enough to hold its shape. The purpose of
the ring gasket is to prevent the test jar from touching the jacket.
7) Cooling Bath
6
4. Technical specifications of EIE Cloud & Pour Point Apparatus
Technical Specifications
7
5. Delivery and Uncrating the instrument
a) Inspect equipment and shipping crate immediately upon receipt. If any damage is apparent,
immediately discuss it with the delivery person and contact the transportation company
immediately. Make notes of any damages on the bill of landing.
b) Retain all shipping material for later inspection.
c) Check packing slip carefully and ensure all materials have been received as indicated in the packing
slip.
d) Instrument is supplied in enclosed wooden case. Unpack the wooden case, locate and count the
number of accessories and main working unit. Remove packing strip from surroundings of the
instrument and all its accessories. Please inspect and note whether any part of the instrument is
damaged or any accessory is missing according to packing slip? If it is so, then immediately make
note of it and report to the manufacturer.
e) Due to the vibration incurred during shipping and handling, it is possible that mechanical connection
could become loose. Inspect all connection to ensure that they are secure.
f) After visual inspection, if everything is found to be okay, transit the instrument to suitable safe place
where it is intended to install. Caution : Heavy weight, protect yourself first. Handle with care.
g) Recycle the packing material and wooden box. Do not throw it away for environment protection.
6. Installation Instructions
1) Place the equipment on a plain, even and sturdy surface leaving 5-6” space away from the wall.
2) Allow enough space around the chamber to permit serviceability and the removal of the service
access panels, which are located on each side and the rear of the unit.
3) Do not install unit in a corrosive environment. A corrosive environment may lead to poor
performance and deterioration of exterior appearance.
4) Check the electrical specifications label located on the equipment. Make sure the power
specifications must confirm to your local standard.
5) Read this instruction manual carefully and abide to its requisites.
6) The ambient temperature should not be more than 30 °C.
7) Provide 1Ø / 230V / 50Hz stabilized power source with proper earthing.
8) Plug the power cord into a properly grounded outlet.
8
7. Test procedure
9
8. Troubleshooting
10
10. Warranty Certificate
Your EIE product is guaranteed to be free from defects in materials and workmanship for one ( 1 ) year
under normal use from the date of purchase. This WARRNATY does not apply to any product damaged
by accident, misuse, mishandling, abuse, negligence, transit, improper line voltage, drop, fire, flood or if
the products were altered or repaired by anyone other than the qualified service personnel.
The liability of EIE Instruments is limited to repair or replacement and under no circumstances shall EIE
be liable for any collateral consequential damages or loss. This guarantee specifically excludes the
expendables and consumables. All warranty claims must be directed to your corresponding purchase
organization that is responsible for the sale of this equipment. The users are responsible for shipping
expense. The warranty cards which are not signed and stamped by the actual user will be treated as
void. The warranty card should accompany the defective products sent for repair, without which no
claims would be entertained. Please detach the below warranty card from following cut-line.
…………………………………………………………………………………………………………………………
This card should be detached, filled in properly and posted within 15 days from the date of purchase
otherwise the warranty becomes invalid.
11
EIE Instruments (Factory Address) Email : sales@eieinstruments.com
B-14, 15, 16, Zaveri Industrial Estate, Phone : 0091-79-66040613
Opp. Shyam Villa Society, Near Sarswati Vidhyalaya, Fax : 0091-79-66040600
Kathawada GIDC Road, Off National Highway,
Kathawada, Ahmedabad 382430
12