se
hac ee ae ees ae ieee
ENGINEERING CO., LID. Email: assamastip@dohwa.co.kr, Mobile: #91-700276754
TUASRIP/CONTIRI- 5/2022/70 Date 21.07.2022
To
Authorized Signatory,
‘SGCCL-ANPL (JV)
4" Floor, Amaze Tower, A.T Road, Beat No-14,
Paltan Bazar, Guwahati-781001
Project: Construction Supervision Consultancy Services for Improvement and Up gradation
of Roads under ASRIP (Moran Naharkatia road (Moran to Deesang Kinar Bangali) under
ASRIP/A/RI- 5)
‘Sub: Review of BBS of RCC Box Culvert
Ref.: your letter No. ANPLIAM/MNRD/2022-23/26 dated 06-07-2022
Dear Sir,
Reference is made to your letter regarding review of BBS (Bar bending Schedule) for RCC
Box culvert and Retaining wall from km 0+000 to 14#000 for the above said project.
In this regard, the comments of Resident Engineer, Moran is attached herewith for your
compliance
With Regards
~— See
V.R. Ramanathan !*°2
‘Team Leader cum Senior Highway Engineer
Dohwa MaRS (JV)
CSC, ASRIP
Guwahati, Assam
Copy to: -
4. The Chief Engin
information please.
2. The Resident Engineer, Moran — for necessary action
r, (EAP) PWRD Assam, Fatasil Ambari, Guwahati- 25 — for kind
Ge
Corporate office
Dohwa ingia Branch Office
‘4.101, i-Thum Tower, Sector 62,Noid, Uttar Pradesh — 201301
Email :abhilash@dohwa co keINTER OFFICE CORRESPONDENCE
[inter/RE/Moran/2022/01 | Date: 08.07.2022
TO From
"Team Leader, Guwahati | Resident Engineer, Moran
‘Sub: Submission of Bar Bending Schedule of RCC Box Culverts & RCC
Retaining Wall
Ref. Contractor Letter No: SGCCL-ANPL/AMIMNRD/2022-23/26
Dated 06.07.2022
Dear Sir,
Copy of Bar Bending Schedule of RCC Box Culverts & RCC Retaining Wall submitted by
the Contractor Vide above referred letter to this office has been reviewed and observed the
follows:-
a) Drawing shall be submitted on A-3 size paper with colour print, BBS of A-4 size
paper.
b) Without Prior approval of P&P i.e. Goods for Construction Drawing BBS Detail may
not be finalized exactly. Because FRL of structure to be finalized accordingly.
c) General arrangement of Drawing is not submitted as per DPR Drawing.
d) Details of dimension (i.e. length, width and height is not shown in plan.
e) Section of Box culvert, Return wall, curtain wall and crash barrier is not shown in
Drawing.
f) Details of level i.e. founding level, Invert level, U/s and Dis for not been shown in
GAD. In addition to Tabular Column, FRL, Founding level, Invert level to be also
shown in GAD.
g) Details of curtain wall and Shear key plan of bottom slab is not shown in drawing,
h) Chainage of particular drawing shall be mentioned at the bottom in column at each
drawing, As mentioned in attached DPR drawing.
In view of above, Contractor is requested for resubmission this drawing with the above
mentioned details and as per DPR Drawing enclosed her with.
With Regards
ye
‘Sunil Kumar Singh oe
Resident Engineer ee
For Dohwa MaRS (JV) got Y or
Moran SP ie ca 1 Sa
- ot ‘| ot 2 es
e ee
ae