Service Information

Document Title: Function Group: Information Type: Date:


Defroster actuator, 874 Service Information 1/24/2022
replacing
Profile:
CEX, EW60C [GB]

Defroster actuator, replacing


Op nbr 874-021

Total procedure time (hr): 5.00

1. Park the machine in the service position A, see: Service positions

2. Turn OFF the battery disconnect switch.

3. Remove the cab. See: Cab, removing

4. Remove the seat. See: Operator's seat, removal.

5. Remove screws (2) and the right-hand duct cover (1).

Figure 1

6. Remove the screws and the seat support plate (1).


Figure 2

7. Disconnect connector (1) for defroster actuator and remove screws (2) and defroster actuator.

Figure 3

8. Install the new defroster actuator. The installation procedure is the reverse order of removal.

9. Install the seat. See: Seat, replacing.

10. Install the cab, See: Operator's seat, installation.

11. Check the defroster actuator operation.