FLUID LNG
FLOW RATE ( ㎥/sec. ) Q 4000(㎥/h) = 4000/3600 = 1.11m³/sec
NOMINAL SIZE D 16B (400A)
0.024×[(0.57×470×9.792)/(0.38×2×9.8)]
f₁[(L․ρ․V²)/(D₁․2․g)] ΔP₁
BODY PIPE = 82㎏/㎡ = 0.082mAq
PRESSURE LOSS
FACTOR f₁ 0.024
g 9.8m/sec²
2 2
0.2×(1/0.189-1) × 3.7 ×470/(2×9.8)
ELEMENT f₂×(1/A0 -1)²× V0²×ρ/(2․g) ΔP₂
= 1208kg/㎡ =1.208mAq
PRESSURE DROP
FACTOR f₂ 0.2
INITIAL
( ΔP₁+ΔP₂) ΔP (0.082+1.208) = 1.29mAq = 0.13bar
PRESSURE DROP
RATIO OF
A₂/A₁ TIMES 0.3/0.11335 = 2.6
OPEN AREA
(1) Tensile Strength against Impact of 700mm Strainer
2UE
δ =
V ․ η
here,
δ : Tensile Strength[N/m²=0.1kgf/m²]
U : Movement Energy ( ½mv²)
E : Young's modulus [N/m²]
V : Volume [m³]
η : Volume Efficiency
Gas Condition at
Weight : 1kgf, Speed(υ)=10m/sec,
E = 205000 N/mm²
= 20.5 × 1010 N/m²
π
V = × H (R² + R ․ r + r²)
3
π
= × 0.7 × (0.1852+ 0.185 × 0.1225 +0.12252)
3
= 0.053m³ at perforated plate
1
U = mv²
2
1 1 2
= × × 10
2 9.8
= 5.102 kg․m²/sec²
P-∅ 24-20
η = = = 0.17
P 24
2UE
∴δ =
V ․ η
-3-
(2) Strength Calculation for Element(Perforated Plate)
Type K-620
Size 16B
Mat'l SUS 316L
Perforat'n 3t × Ø20 × 24p × 60°
Design Temp. -196℃
= 4.09 (N/mm²) α = 0
-4-
(3) Strength Calculation for Bottom Plate
C = 3.2
δ = 15.24 N/mm²
d = 90
tr = 2.4
α = 0
※ tr: t․ tr = (t - tr) (p - Ø)
6․tr = (6-tr) (16-12)
tr = 2.4
100 ․ C ․ δ ․ (tr-α)2
Pb =
d2