DO NOT SCALE THIS DRAWING.

KEY PLAN

NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS
OTHERWISE SPECIFIED.
2. CONCRETE SHALL BE AS PER SPECIFICATIONS UNLESS
OTHERWISE NOTED..
TYPE 1 : 3. MANHOLE FRAME AND COVER SHALL BE DUCTILE IRON
HEAVY DUTY (TEST LOAD 400 kN) AS SPECIFIED.
ONE CATCH BASIN
HAND BAR 4. PRE CAST MANHOLE SECTION SHALL CONFORM TO
ASTM C478.
2 NO. PRECAST RING CONCRETE 5. DEFORMED REINFORCEMENT WITH MINIMUM YEILD
FINISHED SURFACE LEVEL
PIPE Ø300 TO Ø700 STRENGTH OF 460 N/mm² TO BE USED.

300 FINISHED SURFACE LEVEL 6. DESIGN OF THE MANHOLE COVER SHALL BE AS


300
ROCKER PIPE APPROVED BY THE CLIENT.

25
250 MIN.
150mm 7. TOP OF MANHOLE COVER SHALL BE MATCHED WITH
CONCRETE FINISHED SURFACE
ENCASEMENT
8. ALL STORM WATER PIPES TO RUN SOFFIT TO SOFFIT
THROUGH CHAMBER.

250
HAUNCHING CONCRETE
9. ALL STRUCTURAL EXCAVATION AND BACK FILL SHALL BE
PERFORATED IN ACCORDANCE WITH SPECIFICATION. SITE ORIENTATION DATUM
665
CATCH BASIN GRATING AND SCREEN BUCKET
700 MIN. 570 10. AFTER EXCAVATION, BOTTOM SOIL SHALL BE CHECKED
FRAMES WITH REMOVABLE HEAVY DUTY GRATING, 4- Ø12 (INSTRUCTED BY
FLOW

FOR STRUCTURAL STABILITY OTHERWISE SOIL SHALL BE GEODETIC DATUM: WGS-84


SAND EXCLUDING PLATES NET OPENING AREA NOT BE ENGINEER) PROJECT SYSTEM: UTM

300
LESS THAN 975 cm2 REPLACED WITH STRUCTURAL FILL. ZONE: 38N
FOR EACH COVER. STEPS N
4- Ø20 11. ALL CONCRETE COVER OVER REINFORCEMENT SHALL BE cca
Me
ACCORDING TO SPECIFICATIONS AND NOT LESS THAN
Ø12 @ 200 Ø12 @ 200 50mm UNLESS OTHERWISE NOTED.
250

12. NEOPRENE MEMBRANE SHALL BE PROVIDED BETWEEN Disclaimer:By the Consultant's review status indicated herein, the Contractor shall not be relieved of
655x655 responsibility for any deviation from the requirements of the Contract Documents, unless the Contractor
Ø12 @ 200 Ø12 @ 200 CONTACT SURFACE OF CONCRETE AND PIPE.
E

665
has specifically informed the Consultant of such deviation in writing at the time of the submission. The

570
Contractor shall not be relieved from responsibility for errors, omissions or uncoordinated information in
13. CONCRETE SURROUND FOR PIPE PROTECTION SHALL BE

120
the submission or non-compliance with the Contract Documents and Applicable Laws. The recipient is
PROVIDED WHERE PIPE COVER IS LESS THAN 1.0m. responsible to ensure the contents of this disclaimer are understood by personnel in their organization.
CLEAR OPENING

GENERAL NOTES
PIPE Ø300 TO Ø700 570x570 14. ALL PIPES BUILT INTO STRUCTURES SHALL HAVE A
150 MIN. FLEXIBLE JOINT AS DETAILED IN THE STANDARD DRAWINGS.
D 665x665
1000

570

15. CONCRETE CRADLE OR ENCASEMENT SHALL BE USED


WHERE SPECIFIED OR INDICATED ON THE DRAWINGS AND
CONSTRUCTION JOINT AS DIRECTED BY THE ENGINEER IN ACCORDANCE WITH

300
(TYPICAL) PIPE DEPTH & PREVAILING SOIL CONDITION WHERE THE
Ø12 @ 200 WATER STOP PIPE IS TO BE LAID.
(TYPICAL)
PLAN SECTION

250150
16. PIPE TRENCHES MAY BE EXCAVATED WIDER THAN
E
250

WATERPROOFING MEMBRANE TRENCH WIDTH ABOVE THE LINE OF NARROW


(APPROVED BY ENGINEER) TRENCH LIMIT.
570 17. BELOW THE "LINE OF NARROW TRENCH LIMIT" THE
CLEAR OPENING POLYETHYLENE SHEET DETAIL OF CATCH BASIN COVER
50
TRENCH SHOULD NOT BE EXCAVATED BEYOND THE
250 1000 250 Ø12 @ 200 TRENCH WIDTH.
(SINGLE GRATE)
100 250 1000 250 100 18. NARROW TRENCH WIDTH AS PER SPECIFIED IN STANDARD
PIPE TRENCH DETAILS SD-004 SERIES.
150mm THICK CRUSHED
PLAN ROCK BEDDING
75 mm BLINDING CONCRETE 19. ALL CATCHBASIN LEADS PIPE SHALL BE 300mm (MIN.)
SECTION D DIAMETER HAVING A MINIMUM SLOPE OF 0.002 m/m.
20. CATCHBASIN PIPE SHALL BE BEDDED EVENLY ON GRADE
3D/20 CONCRETE 150 mm THICK.
21. ALL CATCHBASIN PIPE SHALL BE BACKFILLED WITH
COMPACTED GRANULAR MATERIAL AS SPECIFIED.
22. MAXIMUM DEPTH OF CATCH BASIN SHOULD NOT EXCEED
HAND BAR 2 m UNLESS OTHERWISE AGREED WITH THE ENGINEER.

2 NO. PRECAST RING CONCRETE 23. ALL EMBEDDED STEEL ITEMS IN CONCRETE SHALL BE
TYPE 2 : C
L OF PIPE
KERB
GALVANIZED.
SIDEWALK 24. IF THE LOCATION OF CATCH BASIN IS IN SAG POINT, THE
ONE CATCH BASIN 300 570 200
DIRECTION OF OPENING CAN BE EITHER IN THE SAME
FINISHED SURFACE LEVEL DIRECTION OR PERPENDICULAR TO THE FLOW. ON THE

25
250 (MIN.)
HIGHER LEVEL THE DIRECTION OF OPENING SHALL BE IN
DIRECTION OF FLOW.
A ISSUED FOR 100% DETAILED DESIGN AA HS 15/09/2023
25. ALL CONCRETE STRUCTURES BELOW GROUND LEVEL TO REV DESCRIPTION APRV CHK'D DATE
BE PROTECTED WITH WATER PROOFING SYSTEM AS PER
KERB

250
HAUNCHING CONCRETE SPECIFICATIONS UNLESS OTHERWISE NOTED. DRAWING REVISIONS
SIDEWALK / FOOTPATH

STEPS 26.THIS DRAWINGS AS PER K.S.A STANDARD.


Ø12 @ 200 4- Ø12 4- Ø20
150mm 27.RRFER TO : S0487-RPT-PM-06REV0-THE STANDARD CLIENT
EACH FACE
250

TECHNICAL SPECIFICATIONS FOR SEWEAGE NETWORKS-


CONCRETE
700 MIN. Ø12 @ 200

300
NATIONAL WATER COMPANY(NWC)

DGCL
ENCASEMENT
ROCKER PIPE EACH FACE
ROCKER PIPE
CLEAR OPENING

700 MIN. Ø12 @ 200


FLOW (TYPICAL) EACH FACE 8500 PRINCE SATTAM IBN ABDULAZIZ ST,
1000

570

600

AL SODHA DIST, AD DIR’IYAH,


Ø12 @ 200 RIYADH 12572 - 4000,
KINGDOM OF SAUDI ARABIA
EACH FACE WWW.DGDA.GOV.SA

PMC
FLOW MIRAGE LEISURE & DEVELOPMENT
150 MIN.
250

150 mm CONCRETE ENCASEMENT


MULTIDISCIPLINARY DESIGN CONSULTANT
300

PO BOX 333256 OFFICE NO.A201-203


DIRECTION OF FLOW

BUILDING 6 , DUBAI DESIGN DISTRICT

450
HEAVY DUTY WATER STOP(TYPICAL) DUBAI
Ø12 @ 200 UNITED ARAB EMIRATES
700 MIN.

APPROVED GRATING .ss ic.c m


250150

SUB CONSULTANT
BURJ AL SALAM TOWER,
150 mm CONCRETE ENCASEMENT WATERPROOFING MEMBRANE 44TH FLOOR, TRADE CENTRE 1,
(APPROVED BY ENGINEER) DUBAI, PO BOX 118254, UNITED ARAB EMIRATES
TELEPHONE +971 45905 600
CONSTRUCTION WWW.CALLISONRTKL.COM
JOINT (TYPICAL) Ø12 @ 200 POLYETHYLENE SHEET
PROJECT TITLE
100 250 1000 250 100 612 LXR HILTON HOTEL
150mm THICK CRUSHED PROJECT ADDRESS: WADI HANIFAH , RIYADH
ROCK BEDDING 75 mm BLINDING CONCRETE
ROCKER PIPE DRAWING TITLE

STANDARD DETAILS
CL OF PIPE
SECTION F
FOR CATCH BASIN
SHEET 1 OF 2
PURPOSE OF ISSUE SEAL DATE
F
100% DETAILED DESIGN 15/09/2023

DESIGNED DRAWN CHECKED APPROVED

HA AG HS AA

MODEL FILE REF SCALE A1 (594x841) REVISION NO

MODEL FILE REF NTS

DRAWING NUMBER
A
WH-WHG-612-0000-SFC-DWG-IF-600-0000622