Professional Documents
Culture Documents
Proposed Flats 40' x 52' Tariq Road
Proposed Flats 40' x 52' Tariq Road
A A A A A A
40'-0" 40'-0"
BATH BATH
5'-9" x 7' 5'-9" x 7'
BED ROOM BED ROOM
13'-0" x 11'-0" 13'-0" x 11'-0"
DUCT DUCT
5'-9" x 3'-6" 5'-9" x 3'-6"
KITCHENETTE
KITCHENETTE
LOUNGE LOUNGE
19'-3" x 9'-0" 19'-3" x 9'-0"
52'-0"
52'-0"
10'-6"
10'-6"
12'-6"
5'-6" x 3'-6"
5'-6" x 3'-6"
7'-9" 7'-9"
DUCT
DUCT
BATH BATH
7'-0" x 5'-6" 7'-0" x 5'-6"
LIFT LIFT
7'-6" x 5'-6" BED ROOM 7'-6" x 5'-6" BED ROOM
11'-0" x 12'-6" 11'-0" x 12'-6"
LOBBY
8'-0" x 16'-6"
LEV. +7'-0"
UP
UP
4- IN D
KIT.
-0 AW SE
20 G
24
22 R I
D EV
DRAWING & DINING DRAWING & DINING
SERVANT
U.G.W TANK 15'-3" x 11'-6" 15'-3" x 11'-6"
R
ROOM
7'-8" x 11'-2"
9'-6" x 11'-6"
BATH LEV. +7'-0" LEV. +7'-0"
5' x 7'
Sewerage Sump
2' x 2' x 3'
G ON
UP
IN I
W CT
5'-0"
R RU
ST
A
N
O
D
BASEMENT PLAN Lev. -5'-0" GROUND FLOOR PLAN Lev. +5'-0", +7'-0"
C
Client Job ESS- I -AAR TITLE:
GROUND & FIRST
DATE:
22-04-2024
COM. LOCATION. SHEET REF.
PLAN
MR. ALI
ARCH.
PROPOSED FLATS PLANNING , ENGINEERING & SERVICES CONSULTANTS SUITENO. 314,
3-RD.FLOOR MASHRIQ CENTRE SIR SHAH SULAIMAN ROAD ,
GULSHAN- E-IQBAL BLOCK NO.14,KARACHI,P.O.BOX NO.7608
Ref. Rev. SCALE: DRAWN: CHKD. BY JOB NO.
PHONE NO.34890770 FAX NO.(92-21)4941059 E-mail: e_i_a@hotmail.com AS SHOWN M. FAYSAL A=01
A B C
A A A
40'-0"
BATH BATH
5'-9" x 7' 5'-9" x 7'
BED ROOM BED ROOM
13'-0" x 11'-0" 13'-0" x 11'-0"
DUCT DUCT
5'-9" x 3'-6" 5'-9" x 3'-6"
KITCHENETTE
KITCHENETTE
LOUNGE LOUNGE
19'-3" x 9'-0" 19'-3" x 9'-0"
52'-0"
5'-6" x 3'-6"
5'-6" x 3'-6"
7'-9" 7'-9"
DUCT
DUCT
BATH BATH
7'-0" x 5'-6" 7'-0" x 5'-6"
LIFT
BED ROOM 7'-6" x 5'-6" BED ROOM
11'-0" x 12'-6" 11'-0" x 12'-6"
LOBBY
8'-0" x 16'-6"
UP DN
4- IN D
-0 AW SE
20 G
24
22 R I
D EV
11'-6"
11'-6"
R
15'-3" x 14'-6" 15'-3" x 14'-6"
G ON
IN I
W TC
5'-0"
R U
POWDER Glass Glass POWDER
D R
5' x 4'-6" Balcony Balcony 5' x 4'-6"
ST
A
N
O
TYPICAL FLOOR PLAN Lev. +17'-0", 27'-0", 37'-0", 47'-0"
C
Client Job ESS- I -AAR TITLE:
TYPICAL FLOOR
DATE:
22-04-2024
COM. LOCATION. SHEET REF.
PLAN
MR. ALI
ARCH.
PROPOSED FLATS PLANNING , ENGINEERING & SERVICES CONSULTANTS SUITENO. 314,
3-RD.FLOOR MASHRIQ CENTRE SIR SHAH SULAIMAN ROAD ,
GULSHAN- E-IQBAL BLOCK NO.14,KARACHI,P.O.BOX NO.7608
Ref. Rev. SCALE: DRAWN: CHKD. BY JOB NO.
PHONE NO.34890770 FAX NO.(92-21)4941059 E-mail: e_i_a@hotmail.com AS SHOWN M. FAYSAL A=02
Stair tower Stair tower
Lev.+60'-6" Lev.+60'-6"
8'-0"
Machine Room
13'-0"
Lev.+52'-6"
5'-0"
3'-0"
Lev.+47'-6" ROOF ROOF Lev.+47'-6"
10'-0"
10'-0"
10'-0"
Roof Roof
Lev.+37'-6" BATH LOUNGE BATH BED ROOM DRAWING ROOM BATH Lev.+37'-6"
10'-0"
10'-0"
10'-0"
2nd Floor 2nd Floor
Lev.+27'-6" BATH LOUNGE BATH BED ROOM DRAWING ROOM BATH Lev.+27'-6"
10'-0"
10'-0"
10'-0"
1st Floor 1st Floor
Lev.+17'-6" BATH LOUNGE BATH BED ROOM DRAWING ROOM BATH Lev.+17'-6"
10'-0"
10'-0"
10'-0"
10'-9"
4- IN D
-0 AW SE
20 G
24
22 R I
D EV
Lev.+7'-6" BATH LOUNGE BATH BED ROOM DRAWING ROOM Lev.+7'-6"
R
7'-6"
7'-6"
6'-3"
8'-914"
12'-6"
G ON
6"
R.L ± 0'-0" R.L ± 0'-0"
IN I
W CT
5'-9"
5'-0"
5'-0"
R RU
Lev.-5'-0" Lev.-5'-0"
ST
A
N
O
D
C
SECTION A-A
MR. ALI
ARCH.
PROPOSED FLATS PLANNING , ENGINEERING & SERVICES CONSULTANTS SUITENO. 314,
3-RD.FLOOR MASHRIQ CENTRE SIR SHAH SULAIMAN ROAD ,
GULSHAN- E-IQBAL BLOCK NO.14,KARACHI,P.O.BOX NO.7608
Ref. Rev. SCALE: DRAWN: CHKD. BY JOB NO.
PHONE NO.34890770 FAX NO.(92-21)4941059 E-mail: e_i_a@hotmail.com AS SHOWN M. FAYSAL A=03
Stair tower Stair tower
Lev.+60'-6" Lev.+60'-6"
8'-0"
8'-0"
Machine Room
13'-0"
MACHINE
Lev.+52'-6" ROOM
18'-0"
5'-0"
5'-0"
Stair Roof
3'-0"
Lev.+47'-6" ROOF
5'-0"
Stair Roof
Lev.+42'-6"
10'-0"
10'-0"
10'-0"
5'-0"
Roof
Lev.+37'-6"
10'-0"
BED ROOM LOUNGE LOBBY
5'-0"
Roof
Lev.+32'-6"
10'-0"
10'-0"
10'-0"
5'-0"
2nd Floor
Lev.+27'-6"
10'-0"
BED ROOM LOUNGE LOBBY
5'-0"
2nd Floor
Lev.+22'-6"
10'-0"
10'-0"
10'-0"
5'-0"
1st Floor
Lev.+17'-6"
10'-0"
BED ROOM LOUNGE LOBBY
5'-0"
1st Floor
Lev.+12'-6"
10'-0"
10'-0"
10'-0"
4- IN D
-0 AW SE
20 G
5'-0"
24
22 R I
D EV
Lev.+7'-6" BED ROOM LOUNGE LOBBY Lev.+7'-6"
12'-6"
R
4'-6"
4'-6"
7'-6"
LOBBY Lev.+3'-0"
12'-6"
3'-0"
G ON
R.L ± 0'-0" R.L ± 0'-0"
IN I
8'-0"
W CT
5'-0"
5'-0"
R RU
Lev.-5'-0" U.G.W TANK Lev.-5'-0"
ST
A
N
O
D
5'-0"
C
SECTION B-B LIFT PIT Lev.-10'-0"
MR. ALI
ARCH.
PROPOSED FLATS PLANNING , ENGINEERING & SERVICES CONSULTANTS SUITENO. 314,
3-RD.FLOOR MASHRIQ CENTRE SIR SHAH SULAIMAN ROAD ,
GULSHAN- E-IQBAL BLOCK NO.14,KARACHI,P.O.BOX NO.7608
Ref. Rev. SCALE: DRAWN: CHKD. BY JOB NO.
PHONE NO.34890770 FAX NO.(92-21)4941059 E-mail: e_i_a@hotmail.com AS SHOWN M. FAYSAL A=04
Stair Roof Stair Roof
3'-0"
Lev.+47'-6" Lev.+47'-6"
10'-0"
10'-0"
10'-0"
Roof Roof
Lev.+37'-6" BED ROOM LOUNGE BED ROOM DRAWING ROOM Lev.+37'-6"
10'-0"
10'-0"
10'-0"
2nd Floor 2nd Floor
Lev.+27'-6" BED ROOM LOUNGE BED ROOM DRAWING ROOM Lev.+27'-6"
10'-0"
10'-0"
10'-0"
1st Floor 1st Floor
Lev.+17'-6" BED ROOM LOUNGE BED ROOM DRAWING ROOM Lev.+17'-6"
10'-0"
10'-0"
10'-0"
4- IN D
-0 AW SE
20 G
24
22 R I
D EV
Lev.+7'-6" BED ROOM LOUNGE BED ROOM DRAWING ROOM Lev.+7'-6"
R
7'-6"
7'-6"
12'-6"
G ON
R.L ± 0'-0" R.L ± 0'-0"
IN I
W CT
5'-0"
5'-0"
R RU
Lev.-5'-0" SERVANT ROOM Lev.-5'-0"
ST
A
3'-0"
N
O
D
Lev.-8'-0"
C
Sewerage
Sump
SECTION C-C
MR. ALI
ARCH.
PROPOSED FLATS PLANNING , ENGINEERING & SERVICES CONSULTANTS SUITENO. 314,
3-RD.FLOOR MASHRIQ CENTRE SIR SHAH SULAIMAN ROAD ,
GULSHAN- E-IQBAL BLOCK NO.14,KARACHI,P.O.BOX NO.7608
Ref. Rev. SCALE: DRAWN: CHKD. BY JOB NO.
PHONE NO.34890770 FAX NO.(92-21)4941059 E-mail: e_i_a@hotmail.com AS SHOWN M. FAYSAL A=05